Search NASA⌕ Search

SEARCH · Search NASA

Results for “Modeling Miniaturizing Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Modeling a Miniaturized Scanning Electron Microscope Focusing Column - Lessons Learned in Electron Optics Simulation

This presentation discusses work done to assess the design of a focusing column in a miniaturized Scanning Electron Microscope (SEM) developed at the NASA Marshall Space Flight Center (MSFC) for use in-situ on the Moon-in particular for mineralogical analysis. The MSFC beam column design uses purely electrostatic fields for focusing, because of the severe constraints on mass and electrical power consumption imposed by the goals of lunar exploration and of spaceflight in general. The resolution of an SEM ultimately depends on the size of the focused spot of the scanning beam probe, for which the stated goal here is a diameter of 10 nanometers. Optical aberrations are the main challenge to this performance goal, because they blur the ideal geometrical optical image of the electron source, effectively widening the ideal spot size of the beam probe. In the present work the optical aberrations of the mini SEM focusing column were assessed using direct tracing of non-paraxial rays, as opposed to mathematical estimates of aberrations based on paraxial ray-traces. The geometrical ray-tracing employed here is completely analogous to ray-tracing as conventionally understood in the realm of photon optics, with the major difference being that in electron optics the lens is simply a smoothly varying electric field in vacuum, formed by precisely machined electrodes. Ray-tracing in this context, therefore, relies upon a model of the electrostatic field inside the focusing column to provide the mathematical description of the "lens" being traced. This work relied fundamentally on the boundary element method (BEM) for this electric field model. In carrying out this research the authors discovered that higher accuracy in the field model was essential if aberrations were to be reliably assessed using direct ray-tracing. This led to some work in testing alternative techniques for modeling the electrostatic field. Ultimately, the necessary accuracy was attained using a BEM/Fourier series hybrid approach. The presentation will give background remarks about the MSFC mini Lunar SEM concept and electron optics modeling, followed by a description of the alternate field modeling techniques that were tried, along with their incorporation into a ray-trace simulation. Next, the validation of this simulation against commercially available software will be discussed using an example lens as a test case. Then, the efficacy of aberration assessment using direct ray-tracing will be demonstrated, using this same validation case. The discussion will include practical error checks of the field solution. Finally, the ray-trace assessment of the MSFC mini Lunar SEM concept will be shown and discussed. The authors believe this presentation will be of general interest to practitioners of modeling and simulation, as well as those with a general optics background. Because electron optics and photon optics share many basic concepts (e.g., lenses, images, aberrations, etc.), the appeal of this presentation need not be restricted to just those interested in charged particle optics.

Modeling Miniaturizing Scanning↗

NASA Tech Briefs, May 2009

Topics covered include: Valve-"Health"-Monitoring System; Microstrip Antenna for Remote Sensing of Soil Moisture and Sea Surface Salinity; Biomedical Wireless Ambulatory Crew Monitor; Wireless Avionics Packet to Support Fault Tolerance for Flight Applications; Aerobot Autonomy Architecture; Submillimeter Confocal Imaging Active Module; Traveling-Wave Maser for 32 GHz; System Synchronizes Recordings from Separated Video Cameras; Piecewise-Planar Parabolic Reflectarray Antenna; Reducing Interference in ATC Voice Communication; EOS MLS Level 1B Data Processing, Version 2.2; Auto-Generated Semantic Processing Services; Geospatial Authentication; Maneuver Automation Software; Event Driven Messaging with Role-Based Subscriptions; Estimating Relative Positions of Outer-Space Structures; Fabricating PFPE Membranes for Capillary Electrophoresis; Linear Actuator Has Long Stroke and High Resolution; Installing a Test Tap on a Metal Battery Case; Fabricating PFPE Membranes for Microfluidic Valves and Pumps; Room-Temperature-Cured Copolymers for Lithium Battery Gel Electrolytes; Catalysts for Efficient Production of Carbon Nanotubes; Amorphous Silk Fibroin Membranes for Separation of CO2; "Zero-Mass" Noninvasive Pressure Transducers; Radial-Electric-Field Piezoelectric Diaphragm Pumps; Ejector-Enhanced, Pulsed, Pressure-Gain Combustor; Suppressing Ghost Diffraction in E-Beam-Written Gratings; Target-Tracking Camera for a Metrology System; Polarimetric Imaging using Two Photoelastic Modulators; Miniature Wide-Angle Lens for Small-Pixel Electronic Camera; Modal Filters for Infrared Interferometry; Mo(3)Sb(7-x)Te(x) for Thermoelectric Power Generation; Two-Dimensional Quantum Model of a Nanotransistor; Scanning Miniature Microscopes without Lenses; Manipulating Neutral Atoms in Chip-Based Magnetic Traps; Expansion Compression Contacts for Thermoelectric Legs; Processing Electromyographic Signals to Recognize Words; Physical Principle for Generation of Randomness; DSN Beowulf Cluster-Based VLBI Correlator; Hybrid NN/SVM Computational System for Optimizing Designs; Criteria for Modeling in LES of Multicomponent Fuel Flow; Computerized Machine for Cutting Space Shuttle Thermal Tiles; Orbiting Depot and Reusable Lander for Lunar Transportation; FPGA-Based Networked Phasemeter for a Heterodyne Interferometer; Aquarius Digital Processing Unit; Three-Dimensional Optical Coherence Tomography; Benchtop Antigen Detection Technique using Nanofiltration and Fluorescent Dyes; Isolation of Precursor Cells from Waste Solid Fat Tissue; Identification of Bacteria and Determination of Biological Indicators; Further Development of Scaffolds for Regeneration of Nerves; Chemically Assisted Photocatalytic Oxidation System; Use of Atomic Oxygen for Increased Water Contact Angles of Various Polymers for Biomedical Applications; Crashworthy Seats Would Afford Superior Protection; Open-Access, Low-Magnetic-Field MRI System for Lung Research; Microfluidic Mixing Technology for a Universal Health Sensor; Microfluidic Extraction of Biomarkers using Water as Solvent; Microwell Arrays for Studying Many Individual Cells; Droplet-Based Production of Liposomes; and Identifying and Inactivating Bacterial Spores

Source record↗

Hollow Cathode and Keeper-region Plasma Measurements Using Ultra-fast Miniature Scanning Probes

In order to support the development of comprehensive performance and life models for future deep space missions that will utilize ion thrusters, we have undertaken a study of the plasma structure in hollow cathodes using an new pneumatic scanning probe diagnostic. This device is designed to insert a miniature probe directly into the hollow cathode orifice from either the upstream insert region in the interior of the hollow cathode, or from the downstream keeper-plasma region at the exit of the hollow cathode, to provide complete axial profiles of the discharge plasma parameters. Previous attempts to diagnose this region with probes was Limited by the melting of small probes in the intense discharge near the orifice, or caused significant perturbation of the plasma by probes large enough to survive. Our new probe is extremely compact, and when configured as a single Langmuir probe, the ceramic tube insulator is only 0.5mm in diameter and the current collecting conductor has a total area of 0.002 cm2. A series of current-voltage characteristics are obtained by applying a rapid sawtooth voltage waveform to the probe as it is scanned by the pneumatic actuator into and out of the plasma region, The bellow-sealed pneumatic drive scans the probe 4 cm in the cathode insert region and 10 cm in the anode/keeper plasmas region at average speeds of about 1 mm/msec, and the residence time at the end of the insertion stroke in the densest part of the plasma near the orifice is measured to be only 10 msec. Since the voltage sweep time is fast compared to the motion of the probe, axial profiles of the plasma density, temperature and potential with reasonable spatial resolution are obtained. Measurements of the internal cathode pressures and the axial plasma-parameter profiles for a hollow cathode operating at discharge currents of up to 35 A in xenon will be presented.

plasma generation↗

Ultrasonic scanning system for in-place inspection of brazed tube joints

A miniaturized ultrasonic scanning system for nondestructive in-place, non-immersion testing of brazed joints in stainless-steel tubing is described. The system is capable of scanning brazed tube joints, with limited clearance access, in 1/4 through 5/8 inch union, tee, elbow and cross configurations. The system has the capability to detect defective conditions now associated with material density changes in addition to those which are depended upon density variations. The system includes a miniaturized scanning head assembly that fits around a tube joint and rotates the transducer around and down the joint in a continuous spiral motion. The C-scan recorder is similar in principle to conventional models except that it was specially designed to track the continuous spiral scan of the tube joint. The scanner and recorder can be operated with most commercially available ultrasonic flaw detectors.

Haynes, J. L.↗

Pressure and force measurements on models set in hypersonic flows: A review

A review of measurement techniques used to obtain aerodynamic forces and moments and surface/flow field pressures for models tested in impulse hypersonic-hypervelocity facilities and in conventional-type hypersonic wind tunnels is presented. Although force and moment measurement techniques presently used in hypersonic wind tunnels are relatively unchanged from the 1960's and 1970's, significant advances have recently been made for impulse facilities. For both hypersonic wind tunnels and impulse facilities, the state-of-the-art has advanced via refinements, improved test techniques, and advances in semiconductor technology, data acquisition systems, and computers. The introduction of electronically scanned pressure systems over a decade ago 'revolutionized' pressure measurements in hypersonic wind tunnels and a second 'revolution' is impending with the development and application of optical, two-dimensional, global pressure measurement techniques. The development and continued refinement of miniature piezoresistive transducers has provided the capability to perform detailed surface pressure measurements on relatively small, complex models in impulse facilities; these transducers also provided the capability for intrusive flow field pressure measurements with miniature survey rakes.

Miller, Charles G.↗

Potential Fluctuations and Energetic Ion Production in Hollow Cathode Discharges

Ions with energies significantly in excess of the applied discharge voltage have been reported for many years in hollow cathode discharges. Models of dc potential hills downstream of the cathode and instabilities in postulated double layers in the cathode orifice have been proposed to explain this, but have not been substantiated. Measurements of the dc and rf plasma density and potential profiles near the exit of hollow cathodes by miniature fast-scanning probes suggests that turbulent ion acoustic fluctuations and ionization instabilities in the cathode plume significantly increase the energy of the ions that flow from this region. Increases in the discharge current and/or decreases in the cathode gas flow enhance the amplitude of the fluctuations and increase the number and energy of the energetic ions, which increases the erosion rate of the cathode electrodes. The transition from the quiescent 'spot mode' to the noisy 'plume mode' characteristic of these discharges is found to be a gradual transition of increasing fluctuation amplitudes.

keeper↗

Cloud condensation nuclei activity of internally mixed particle populations at a remote marine free troposphere site in the North Atlantic Ocean

Here, this study reports results from research conducted at the Observatory of Mount Pico (OMP), 2225 m above mean sea level on Pico Island in the Azores archipelago in June and July 2017. We investigated the chemical composition, mixing state, and cloud condensation nuclei (CCN) activities of long-range transported free tropospheric (FT) particles. FLEXible PARTicle Lagrangian particle dispersion model (FLEXPART) simulations reveal that most air masses that arrived at the OMP during the sampling period originated in North America and were highly aged (average plume age > 10 days). We probed size-resolved chemical composition, mixing state, and hygroscopicity parameter ($\mathcal{κ}$) of individual particles using computer-controlled scanning electron microscopy with an energy-dispersive X-ray spectrometer (CCSEM-EDX). Based on the estimated individual particle mass from elemental composition, we calculated the mixing state index, $χ$. During our study, FT particle populations were internally mixed ($χ$ of samples are between 53% and 87%), owing to the long atmospheric aging time. We used data from a miniature Cloud Condensation Nucleus Counter (miniCCNC) to derive the hygroscopicity parameter, $\mathcal{κ}$ CCNC . Combining $\mathcal{κ}$ CCNC and FLEXPART, we found that air masses recirculated above the North Atlantic Ocean with lower mean altitude had higher $\mathcal{κ}$ CCNC due to the higher contribution of sea salt particles. We used CCSEM-EDX and phase state measurements to predict single-particle $\mathcal{κ}$ ($\mathcal{κ}$ CCSEM-EDX ) values, which overlap with the lower range of $\mathcal{κ}$ CCNC measured below 0.15 % SS. Therefore, CCSEM-EDX measurements can be useful in predicting the lower bound of $\mathcal{κ}$, which can be used in climate models to predict CCN activities, especially in remote locations where online CCN measurements are unavailable.

54 ENVIRONMENTAL SCIENCES↗

Autonomous System for Monitoring the Integrity of Composite Fan Housings

A low-cost and reliable system assesses the integrity of composite fan-containment structures. The system utilizes a network of miniature sensors integrated with the structure to scan the entire structural area for any impact events and resulting structural damage, and to monitor degradation due to usage. This system can be used to monitor all types of composite structures on aircraft and spacecraft, as well as automatically monitor in real time the location and extent of damage in the containment structures. This diagnostic information is passed to prognostic modeling that is being developed to utilize the information and provide input on the residual strength of the structure, and maintain a history of structural degradation during usage. The structural health-monitoring system would consist of three major components: (1) sensors and a sensor network, which is permanently bonded onto the structure being monitored; (2) integrated hardware; and (3) software to monitor in-situ the health condition of in-service structures.

Qing, Xinlin P.↗

Continued Development of Meandering Winding Magnetometer (MWM (Register Trademark)) Eddy Current Sensors for the Health Monitoring, Modeling and Damage Detection of Composite Overwrapped Pressure Vessels

Composite Overwrapped Pressure Vessels (COPVs) are used in essentially all NASA spacecraft, launch. vehicles and payloads to contain high-pressure fluids for propulsion, life support systems and science experiments. Failure of any COPV either in flight or during ground processing would result in catastrophic damage to the spacecraft or payload, and could lead to loss of life. Therefore, NASA continues to investigate new methods to non-destructively inspect (NDE) COPVs for structural anomalies and to provide a means for in-situ structural health monitoring (SHM) during operational service. Partnering with JENTEK Sensors, engineers at NASA, Kennedy Space Center have successfully conducted a proof-of-concept study to develop Meandering Winding Magnetometer (MWM) eddy current sensors designed to make direct measurements of the stresses of the internal layers of a carbon fiber composite wrapped COPV. During this study three different MWM sensors were tested at three orientations to demonstrate the ability of the technology to measure stresses at various fiber orientations and depths. These results showed good correlation with actual surface strain gage measurements. MWM-Array technology for scanning COPVs can reliably be used to image and detect mechanical damage. To validate this conclusion, several COPVs were scanned to obtain a baseline, and then each COPV was impacted at varying energy levels and then rescanned. The baseline subtracted images were used to demonstrate damage detection. These scans were performed with two different MWM-Arrays. with different geometries for near-surface and deeper penetration imaging at multiple frequencies and in multiple orientations of the linear MWM drive. This presentation will include a review of micromechanical models that relate measured sensor responses to composite material constituent properties, validated by the proof of concept study, as the basis for SHM and NDE data analysis as well as potential improvements including design changes to miniaturize and make the sensors durable in the vacuum of space

Russell, Richard↗

The Next Generation of Spaceborne Radars for Cloud and Precipitation Measurements

NASA’s Earth Science Technology Office (ESTO) is currently developing advanced instrument concepts and technologies for the next generation of spaceborne atmospheric radars for clouds and precipitation measurements. Two representative examples are the Radar in a CubeSat (RainCube) – a miniaturized Ka-band precipitation intensity profiling radar for operation on a 6U CubeSat bus; and the Multi-Application Smallsat Tri-band Radar (MASTR) – a Ku/Ka/W band, electronic scanning, and Doppler atmospheric radar. These radar concepts will be capable of providing information on both the state and the process of the atmospheric water (as opposed to just the state information provided by existing spaceborne radars) to fill the current observational gaps in the advancement of weather and climate models.

Im, Eastwood↗

Multimodality Instrument for Tissue Characterization

A system with multimodality instrument for tissue identification includes a computer-controlled motor driven heuristic probe with a multisensory tip is discussed. For neurosurgical applications, the instrument is mounted on a stereotactic frame for the probe to penetrate the brain in a precisely controlled fashion. The resistance of the brain tissue being penetrated is continually monitored by a miniaturized strain gauge attached to the probe tip. Other modality sensors may be mounted near the probe tip to provide real-time tissue characterizations and the ability to detect the proximity of blood vessels, thus eliminating errors normally associated with registration of pre-operative scans, tissue swelling, elastic tissue deformation, human judgement, etc., and rendering surgical procedures safer, more accurate, and efficient. A neural network, program adaptively learns the information on resistance and other characteristic features of normal brain tissue during the surgery and provides near real-time modeling. A fuzzy logic interface to the neural network program incorporates expert medical knowledge in the learning process. Identification of abnormal brain tissue is determined by the detection of change and comparison with previously learned models of abnormal brain tissues. The operation of the instrument is controlled through a user friendly graphical interface. Patient data is presented in a 3D stereographics display. Acoustic feedback of selected information may optionally be provided. Upon detection of the close proximity to blood vessels or abnormal brain tissue, the computer-controlled motor immediately stops probe penetration.

Mah, Robert W.↗

Multimodality instrument for tissue characterization

A system with multimodality instrument for tissue identification includes a computer-controlled motor driven heuristic probe with a multisensory tip. For neurosurgical applications, the instrument is mounted on a stereotactic frame for the probe to penetrate the brain in a precisely controlled fashion. The resistance of the brain tissue being penetrated is continually monitored by a miniaturized strain gauge attached to the probe tip. Other modality sensors may be mounted near the probe tip to provide real-time tissue characterizations and the ability to detect the proximity of blood vessels, thus eliminating errors normally associated with registration of pre-operative scans, tissue swelling, elastic tissue deformation, human judgement, etc., and rendering surgical procedures safer, more accurate, and efficient. A neural network program adaptively learns the information on resistance and other characteristic features of normal brain tissue during the surgery and provides near real-time modeling. A fuzzy logic interface to the neural network program incorporates expert medical knowledge in the learning process. Identification of abnormal brain tissue is determined by the detection of change and comparison with previously learned models of abnormal brain tissues. The operation of the instrument is controlled through a user friendly graphical interface. Patient data is presented in a 3D stereographics display. Acoustic feedback of selected information may optionally be provided. Upon detection of the close proximity to blood vessels or abnormal brain tissue, the computer-controlled motor immediately stops probe penetration. The use of this system will make surgical procedures safer, more accurate, and more efficient. Other applications of this system include the detection, prognosis and treatment of breast cancer, prostate cancer, spinal diseases, and use in general exploratory surgery.

Mah, Robert W.↗

Enzymatic carbon–fluorine bond cleavage by human gut microbes

Fluorinated compounds are used for agrochemical, pharmaceutical, and numerous industrial applications, resulting in global contamination. In many molecules, fluorine is incorporated to enhance the half-life and improve bioavailability. Fluorinated compounds enter the human body through food, water, and xenobiotics including pharmaceuticals, exposing gut microbes to these substances. The human gut microbiota is known for its xenobiotic biotransformation capabilities, but it was not previously known whether gut microbial enzymes could break carbon-fluorine bonds, potentially altering the toxicity of these compounds. Here, through the development of a rapid, miniaturized fluoride detection assay for whole-cell screening, we identified active gut microbial defluorinases. We biochemically characterized enzymes from diverse human gut microbial classes including Clostridia, Bacilli, and Coriobacteriia, with the capacity to hydrolyze (di)fluorinated organic acids and a fluorinated amino acid. Whole-protein alanine scanning, molecular dynamics simulations, and chimeric protein design enabled the identification of a disordered C-terminal protein segment involved in defluorination activity. Domain swapping exclusively of the C-terminus conferred defluorination activity to a nondefluorinating dehalogenase. To advance our understanding of the structural and sequence differences between defluorinating and nondefluorinating dehalogenases, we trained machine learning models which identified protein termini as important features. Models trained on 41-amino acid segments from protein C termini alone predicted defluorination activity with 83% accuracy (compared to 95% accuracy based on full-length protein features). This work is relevant for therapeutic interventions and environmental and human health by uncovering specificity-determining signatures of fluorine biochemistry from the gut microbiome.

Probst, Silke I↗

Studying Corrosion Using Miniaturized Particle Attached Working Electrodes and the Nafion Membrane

We developed a new approach to attach particles onto a conductive layer as a working electrode (WE) in a microfluidic electrochemical cell with three electrodes. Nafion, an efficient proton transfer molecule, is used to form a thin protection layer to secure particle electrodes. Spin coating is used to develop a thin and even layer of Nafion membrane. The effects of Nafion (5 wt% 20 wt%) and spinning rates were evaluated using multiple sets of replicates. The electrochemical performance of various devices was demonstrated. Additionally, the electrochemical performance of the devices is used to select and optimize fabrication conditions. The results show that a higher spinning rate and a lower Nafion concentration (5 wt%) induce a better performance, using cerium oxide (CeO2) particles as a testing model. The WE surfaces were characterized using atomic force microscopy (AFM), scanning electron microscopy-focused ion beam (SEM-FIB), time-of-flight secondary ion mass spectrometry (ToF-SIMS), and X-ray photoelectron spectroscopy (XPS). The comparison between the pristine and corroded WE surfaces shows that Nafion is redistributed after potential is applied. Our results verify that Nafion membrane offers a reliable means to secure particles onto electrodes. Furthermore, the electrochemical performance is reliable and reproducible. Thus, this approach provides a new way to study more complex and challenging particles, such as uranium oxide, in the future.

42 ENGINEERING↗

A miniature 48-channel pressure sensor module capable of in situ calibration

A new high data rate pressure sensor module with in situ calibration capability has been developed by the Langley Research Center to help reduce energy consumption in wind-tunnel facilities without loss of measurement accuracy. The sensor module allows for nearly a two order of magnitude increase in data rates over conventional electromechanically scanned pressure sampling techniques. This module consists of 16 solid state pressure sensor chips and signal multiplexing electronics integrally mounted to a four position pressure selector switch. One of the four positions of the pressure selector switch allows the in situ calibration of the 16 pressure sensors; the three other positions allow 48 channels (three sets of 16) pressure inputs to be measured by sensors. The small size of the sensor module will allow mounting within many wind-tunnel models, thus eliminating long tube lengths and their corresponding slow pressure response.

Gross, C.↗

Data-Driven Optimization of the Processing Window for 316H Components Fabricated Using Laser Powder Bed Fusion

The Advanced Materials and Manufacturing Technologies Program is focused on accelerating the development and deployment of advanced materials and components fabricated via additive manufacturing with a specific focus on laser powder bed fusion (LPBF). As an initial case study, the program has selected 316H stainless steel (SS) as an initial material around which to develop a code case development strategy. This strategy involves two parallel approaches: (1) an equivalency approach whereby round-robin testing across multiple collaborating laboratories demonstrates repeatability in processing and direct comparisons with conventional wrought 316H material and (2) a revolutionary approach to code qualification combining in situ data collection and high-fidelity modeling to capture, predict, and bound the performance of LPBF 316HSS components. As part of this campaign, this work package has initiated an extensive process optimization campaign across three laboratories, each printing variations of LPBF 316HSS using three different LPBF units (Concept Laser, EOS, and Renishaw). In FY23, ORNL has focused on unique experimental designs spanning wide ranges in energy inputs and turning knobs such as scan speed, laser power, hatch spacing, layer thickness, spot size, scan rotation, and more. On the Concept Laser M2, 72 different combinations of processing variables were investigated with duplicate samples and different powder compositions. In total, 252 samples were printed with combined in situ sensing data. A parallel design of experiments was conducted on the Renishaw AM400 with an additional 390 printed specimens for analysis. All 642 miniature specimens, each with unique features included in each print to capture geometry-related heterogeneity, were subjected to high-throughput x-ray computed tomography (XCT) analysis to enable the downselection of specific processing parameters of interest. Then, using electrical discharge machining (EDM), miniature tensile specimens were extracted for mechanical testing and microscopy investigations. From the analysis performed in FY23, it was found that powder composition drastically affects the resulting microstructure and mechanical performance of 316SS. Specifically, changing from 316L to 316HSS powder results in a wide range of grain sizes with varying degrees of preferred grain orientation, which increases as a function of energy density. It was also found that due to stored heat in thin fin–type features, large microstructural differences can be seen within one part printed with one set of processing parameters. These variations in microstructure features, including grain size, the nanoscale dislocation structure, and grain texture, will all affect the irradiation performance and high-temperature mechanical performance of LPBF 316HSS parts. Two sets of concept laser processing parameters, spanning both refined and columnar grain structures, were scaled to print larger 316H builds for campaign testing (high-temperature creep and irradiation). In addition, at least two optimized processing parameter sets were identified for the Renishaw AM400 for round-robin testing in FY24 with Argonne National Laboratory. Future work includes printing samples using identical parameters identified by partner institutions, providing material for corrosion and high-temperature mechanical testing, and continuing evaluations of heterogeneity in larger printed parts.

36 MATERIALS SCIENCE↗

Data-Driven Optimization of the Processing Window for 316H Components Fabricated Using Laser Powder Bed Fusion

The Advanced Materials and Manufacturing Technologies Program is focused on accelerating the development and deployment of advanced materials and components fabricated via additive manufacturing with a specific focus on laser powder bed fusion (LPBF). As an initial case study, the program has selected 316H stainless steel (SS) as an initial material around which to develop a code case development strategy. This strategy involves two parallel approaches: (1) an equivalency approach whereby round-robin testing across multiple collaborating laboratories demonstrates repeatability in processing and direct comparisons with conventional wrought 316H material and (2) a revolutionary approach to code qualification combining in situ data collection and high-fidelity modeling to capture, predict, and bound the performance of LPBF 316HSS components. As part of this campaign, this work package has initiated an extensive process optimization campaign across three laboratories, each printing variations of LPBF 316HSS using three different LPBF units (Concept Laser, EOS, and Renishaw). In FY23, ORNL has focused on unique experimental designs spanning wide ranges in energy inputs and turning knobs such as scan speed, laser power, hatch spacing, layer thickness, spot size, scan rotation, and more. On the Concept Laser M2, 72 different combinations of processing variables were investigated with duplicate samples and different powder compositions. In total, 252 samples were printed with combined in situ sensing data. A parallel design of experiments was conducted on the Renishaw AM400 with an additional 390 printed specimens for analysis. All 642 miniature specimens, each with unique features included in each print to capture geometry-related heterogeneity, were subjected to high-throughput x-ray computed tomography (XCT) analysis to enable the downselection of specific processing parameters of interest. Then, using electrical discharge machining (EDM), miniature tensile specimens were extracted for mechanical testing and microscopy investigations. From the analysis performed in FY23, it was found that powder composition drastically affects the resulting microstructure and mechanical performance of 316SS. Specifically, changing from 316L to 316HSS powder results in a wide range of grain sizes with varying degrees of preferred grain orientation, which increases as a function of energy density. It was also found that due to stored heat in thin fin–type features, large microstructural differences can be seen within one part printed with one set of processing parameters. These variations in microstructure features, including grain size, the nanoscale dislocation structure, and grain texture, will all affect the irradiation performance and high-temperature mechanical performance of LPBF 316HSS parts. Two sets of concept laser processing parameters, spanning both refined and columnar grain structures, were scaled to print larger 316H builds for campaign testing (high-temperature creep and irradiation). In addition, at least two optimized processing parameter sets were identified for the Renishaw AM400 for round-robin testing in FY24 with Argonne National Laboratory. Future work includes printing samples using identical parameters identified by partner institutions, providing material for corrosion and high-temperature mechanical testing, and continuing evaluations of heterogeneity in larger printed parts.

36 MATERIALS SCIENCE↗

Miniature, Low-Power, Waveguide Based Infrared Fourier Transform Spectrometer for Spacecraft Remote Sensing

Fourier transform spectrometers have a venerable heritage as flight instruments. However, obtaining an accurate spectrum exacts a penalty in instrument mass and power requirements. Recent advances in a broad class of non-scanning Fourier transform spectrometer (FTS) devices, generally called spatial heterodyne spectrometers, offer distinct advantages as flight optimized systems. We are developing a miniaturized system that employs photonics lightwave circuit principles and functions as an FTS operating in the 7-14 micrometer spectral region. The inteferogram is constructed from an ensemble of Mach-Zehnder interferometers with path length differences calibrated to mimic scan mirror sample positions of a classic Michelson type FTS. One potential long-term application of this technology in low cost planetary missions is the concept of a self-contained sensor system. We are developing a systems architecture concept for wide area in situ and remote monitoring of characteristic properties that are of scientific interest. The system will be based on wavelength- and resolution-independent spectroscopic sensors for studying atmospheric and surface chemistry, physics, and mineralogy. The self-contained sensor network is based on our concept of an Addressable Photonics Cube (APC) which has real-time flexibility and broad science applications. It is envisaged that a spatially distributed autonomous sensor web concept that integrates multiple APCs will be reactive and dynamically driven. The network is designed to respond in an event- or model-driven manner or reconfigured as needed.

Hewagama, TIlak↗