Search NASA⌕ Search

SEARCH · Search NASA

Results for “Modeling and Performance Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Graphical User Interface for Simulink Integrated Performance Analysis Model

The J-2X Engine (built by Pratt & Whitney Rocketdyne,) in the Upper Stage of the Ares I Crew Launch Vehicle, will only start within a certain range of temperature and pressure for Liquid Hydrogen and Liquid Oxygen propellants. The purpose of the Simulink Integrated Performance Analysis Model is to verify that in all reasonable conditions the temperature and pressure of the propellants are within the required J-2X engine start boxes. In order to run the simulation, test variables must be entered at all reasonable values of parameters such as heat leak and mass flow rate. To make this testing process as efficient as possible in order to save the maximum amount of time and money, and to show that the J-2X engine will start when it is required to do so, a graphical user interface (GUI) was created to allow the input of values to be used as parameters in the Simulink Model, without opening or altering the contents of the model. The GUI must allow for test data to come from Microsoft Excel files, allow those values to be edited before testing, place those values into the Simulink Model, and get the output from the Simulink Model. The GUI was built using MATLAB, and will run the Simulink simulation when the Simulate option is activated. After running the simulation, the GUI will construct a new Microsoft Excel file, as well as a MATLAB matrix file, using the output values for each test of the simulation so that they may graphed and compared to other values.

Durham, R. Caitlyn↗

Models of weather effects on noise temperature and attenuation for Ka- and X-band telemetry performance analysis

Models that show the effects of weather on noise temperature and attenuation of deep space telemetry signals received by the Deep Space Network (DSN) at Ka- and X-band (32 and 8.5 GHz) are developed. These models were used to compare the performance of telemetry links at these two frequencies. The models build on an earlier 1982 model that used three months of water vapor radiometer measurements (31.4 GHz) at Goldstone, augmented with one year of radiosonde measurements made at Edwards Air Force Base. This 1986 model accounts for annual variations of rainfall and extends to a model for Canberra, Australia, and Madrid, Spain. The results show, for example, that at Ka-band, 30 degrees elevation angle, Goldstone weather adds less than 23 + or - 2 K to the system temperature 80% of the time, while Canberra or Madrid weather adds less than 32 + or - 5 K 80% of the time. At X-band, the comparable numbers are 5.1 + or - 0.2 K and 5.7 + or - 0.4 K. A simple analysis shows a substantial telemetry system signal-to-noise ratio advantage when operating at Ka-band compared to X-band.

Slobin, S. D.↗

Uncertainty Quantification of Bifacial Performance Modeling

Analysis on uncertainty in the annual energy of PV systems that can be attributed to parameters of particular importance to bifacial PV modules is presented. Monte Carlo simulations are used to evaluate the effect of uncertain module bifaciality factors, module transmission fractions, albedo values, and ground clearance. The analyses cover a wide spectrum of potential PV array archetypes through variation of installation parameters. The results of the Monte Carlo analysis reveal that the uncertainty is largely dependent on albedo uncertainty, but more simulations are needed to identify trends across system archetypes. The simulations are aimed at attributing an annual energy uncertainty factor for bifacial considerations that can be applied in post-processing of project probability of exceedance analysis.

energy modeling↗

Uncertainty Quantification of Bifacial Performance Modeling

Analysis on uncertainty in the annual energy of PV systems that can be attributed to parameters of particular importance to bifacial PV modules is presented. Monte Carlo simulations are used to evaluate the effect of uncertain module bifaciality factors, module transmission fractions, albedo values, and ground clearance. The analyses cover a wide spectrum of potential PV array archetypes through variation of installation parameters. The results of the Monte Carlo analysis reveal that the uncertainty is largely dependent on albedo uncertainty, but more simulations are needed to identify trends across system archetypes. The simulations are aimed at attributing an annual energy uncertainty factor for bifacial considerations that can be applied in post-processing of project probability of exceedance analysis.

bifacial↗

Representations and strategies for transferable machine learning improve model performance in chemical discovery

Strategies for machine-learning (ML)-accelerated discovery that are general across material composition spaces are essential, but demonstrations of ML have been primarily limited to narrow composition variations. By addressing the scarcity of data in promising regions of chemical space for challenging targets such as open-shell transition-metal complexes, general representations and transferable ML models that leverage known relationships in existing data will accelerate discovery. Over a large set (~1000) of isovalent transition-metal complexes, we quantify evident relationships for different properties (i.e., spin-splitting and ligand dissociation) between rows of the Periodic Table (i.e., 3d/4d metals and 2p/3p ligands). We demonstrate an extension to the graph-based revised autocorrelation (RAC) representation (i.e., eRAC) that incorporates the group number alongside the nuclear charge heuristic that otherwise overestimates dissimilarity of isovalent complexes. To address the common challenge of discovery in a new space where data are limited, we introduce a transfer learning approach in which we seed models trained on a large amount of data from one row of the Periodic Table with a small number of data points from the additional row. We demonstrate the synergistic value of the eRACs alongside this transfer learning strategy to consistently improve model performance. Analysis of these models highlights how the approach succeeds by reordering the distances between complexes to be more consistent with the Periodic Table, a property we expect to be broadly useful for other material domains.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preparation of satellite soundings for insertion in a variational objective analysis model

The performance of a variational analysis model being developed at the Illinois State Water Survey, which allows blending of satellite and conventional soundings in a way which preserves the information content of both data sources, requires preparation of the input data before insertion into the model. Using operationally retrieved Tiros-N TOVS soundings and rawinsonde data, four procedures to prepare satellite soundings for model insertion are demonstrated: (1) determination and removal of biases, (2) determination of standard errors of the satellite temperatures to assist in the assignment of weights in the model, (3) conversion of layer mean temperatures to level temperatures, and (4) determination of the action necessary for correcting for the nonsynoptic nature of the satellite data.

Kidder, Stanley Q.↗

Numerical modeling and performance analysis of a membrane-based air dehumidifier using ionic liquid desiccant

Membrane-based Liquid Desiccant Air Dehumidifier (MLDAD) has the potential to overcome the shortcomings of the conventional open-tower liquid desiccant air dehumidifier. The MLDAD uses membranes with high water vapor permeability to separate air stream from the liquid desiccant and thus eliminates carry-over and the resulting corrosion issues. Recently, the ionic liquid desiccant becomes a promising alternative to conventional liquid desiccant. The ionic liquid desiccant has a large potential of dehumidification, which is also non-corrosive to metals and non-crystallizable. A two-dimensional numerical heat and mass transfer model of the MLDAD using a recently identified ionic liquid desiccant, [EMIM]OAc, is presented here. This model can simulate the performance of the MLDAD with various designs, including different selections of liquid desiccant and membrane materials, dimensions of the MLDAD, and flow patterns. For porous membranes, this model accounts for several micro-scale mass transfer mechanisms of vapor transportation across the membrane. It can also model the mass transfer performance of dehumidifiers using non-porous membranes based on the experimentally measured membrane permeance. The numerical model was validated against the performance data available from literature and experimental tests. The maximum discrepancy of the latent effectiveness between the measured and the model-predicted results was about 6% when porous membranes were used. A parametric study was conducted with the numerical model. Finally, the results indicated that the membrane permeability, air path height, and solution to air mass ratio were the most critical parameters, determining the dehumidification performance of the MLDAD.

42 ENGINEERING↗

Numerical modeling and performance analysis of a membrane-based air dehumidifier using ionic liquid desiccant

Membrane-based Liquid Desiccant Air Dehumidifier (MLDAD) has the potential to overcome the shortcomings of the conventional open-tower liquid desiccant air dehumidifier. The MLDAD uses membranes with high water vapor permeability to separate air stream from the liquid desiccant and thus eliminates carry-over and the resulting corrosion issues. Recently, the ionic liquid desiccant becomes a promising alternative to conventional liquid desiccant. The ionic liquid desiccant has a large potential of dehumidification, which is also non-corrosive to metals and non-crystallizable. A two-dimensional numerical heat and mass transfer model of the MLDAD using a recently identified ionic liquid desiccant, [EMIM]OAc, is presented in this paper. We report this model can simulate the performance of the MLDAD with various designs, including different selections of liquid desiccant and membrane materials, dimensions of the MLDAD, and flow patterns. For porous membranes, this model accounts for several micro-scale mass transfer mechanisms of vapor transportation across the membrane. It can also model the mass transfer performance of dehumidifiers using non-porous membranes based on the experimentally measured membrane permeance. The numerical model was validated against the performance data available from literature and experimental tests. The maximum discrepancy of the latent effectiveness between the measured and the model-predicted results was about 6% when porous membranes were used. A parametric study was conducted with the numerical model. The results indicated that the membrane permeability, air path height, and solution to air mass ratio were the most critical parameters, determining the dehumidification performance of the MLDAD.

42 ENGINEERING↗

Modelling and performance analysis of four and eight element TCAS

This semi-annual report describes the work performed during the period September 1989 through March 1990. The first section presents a description of the effect of the engines of the Boeing 737-200 on the performance of a bottom mounted eight-element traffic alert and collision avoidance system (TCAS). The second section deals exclusively with a four element TCAS antenna. The model obtained to simulate the four element TCAS and new algorithms developed for studying its performance are described. The effect of location on its performance when mounted on top of a Boeing 737-200 operating at 1060 MHz is discussed. It was found that the four element TCAS generally does not perform as well as the eight element TCAS III.

Sampath, K. S.↗

Nonlinear modeling and performance analysis of cracked beam microgyroscopes

Cracks constitute a common structural defect in microelectromechanical systems that may arise during manufacturing, mechanical fatigue, or shock loading. Areas weakened by cracks increase the flexibility of the microstructure. Furthermore, depending on the crack severity, the increased flexibility can cause dramatic changes in the static and dynamic behaviors of electrically actuated MEMS. In this study, a numerical investigation of the depth and location of multiple edge cracks on the performance of beam microgyroscopes is conducted. Applying the Griffith strain energy release theorem for an edge crack, the vibrational characteristics of microgyroscopes with multiple cracks including the static deflection, natural frequencies, and mode shapes are studied analytically. Then, the differential quadrature method is employed to model the nonlinear dynamic behaviors of the cracked gyroscope system. Cracks initiated along the driving or sensing directions of the microgyroscope are found to have differing effects on its nonlinear dynamic response. This numerical study reveals that the onset of severe single cracks or a series of multiple cracks can significantly affect the sensitivity of the microgyroscope to base rotations and therefore leads to a degradation in the performance of the damaged MEMS sensor. This study also shows that a potential design approach for broadband microgyroscope systems manufactured with cracks can be proposed.

42 ENGINEERING↗

Modeling and Performance Analysis of the LUVOIR Coronagraph Instrument

Future space missions such as the Large UV/Optical/Infrared Surveyor (LUVOIR) and the Habitable Exoplanet Observatory, when equipped with coronagraphs with active wavefront control to suppress starlight, will allow the discovery and characterization of habitable exoplanets. The Extreme Coronagraph for Living Planetary Systems (ECLIPS) is the coronagraph instrument on the LUVOIR Surveyor mission concept, an 8- to 15-m segmented telescope. ECLIPS is split into three channels, namely, UV (200 to 400 nm), optical (400 to 850 nm), and near IR (850 nm to 2 μm), with each channel equipped with two deformable mirrors for wavefront control, a suite of coronagraph masks, a low-order/out-of-band wavefront sensor, and separate science imagers and spectrographs. The apodized pupil Lyot coronagraph and the vector vortex coronagraph are the baselined mask technologies for ECLIPS to enable the required 10−10 contrast for observations in the habitable zones of nearby stars for LUVOIR-A (15-m telescope) and LUVOIR-B (8-m telescope), respectively. Their performance depends on active wavefront sensing and control, as well as metrology subsystems to compensate for aberrations induced by segment errors (e.g., piston and tip/tilt), secondary mirror misalignment, and global low-order wavefront errors. Here, we present the latest results of the simulation of these effects for the LUVOIR coronagraph instrument and discuss the achieved contrast for exoplanet detection and characterization after closed-loop wavefront estimation and control algorithms have been applied. Finally, we show simulated observations using high-fidelity spatial and spectral input models of complete planetary systems generated with the Haystacks code framework.

Roser Juanola-Parramon↗