Search NASA⌕ Search

SEARCH · Search NASA

Results for “Models, Cardiovascular”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Simulation of a G-tolerance curve using the pulsatile cardiovascular model

A computer simulation study, performed to assess the ability of the cardiovascular model to reproduce the G tolerance curve (G level versus tolerance time) is reported. A composite strength duration curve derived from experimental data obtained in human centrifugation studies was used for comparison. The effects of abolishing automomic control and of blood volume loss on G tolerance were also simulated. The results provide additional validation of the model. The need for the presence of autonomic reflexes even at low levels of G is pointed out. The low margin of safety with a loss of blood volume indicated by the simulation results underscores the necessity for protective measures during Shuttle reentry.

Solomon, M.↗

User's instructions for the GE cardiovascular model to simulate LBNP and tilt experiments, with graphic capabilities

The present form of this cardiovascular model simulates both 1-g and zero-g LBNP (lower body negative pressure) experiments and tilt experiments. In addition, the model simulates LBNP experiments at any body angle. The model is currently accessible on the Univac 1110 Time-Shared System in an interactive operational mode. Model output may be in tabular form and/or graphic form. The graphic capabilities are programmed for the Tektronix 4010 graphics terminal and the Univac 1110.

Source record↗

Cardiovascular model for the simulation of exercise, lower body negative pressure, and tilt experiments

A mathematical model and digital computer simulation of the human cardiovascular system and its controls have been developed to simulate pulsatile dynamic responses to the cardiovascular experiments of the Skylab missions and to selected physiological stresses of manned space flight. Specific model simulations of the bicycle ergometry, lower body negative pressure, and tilt experiments have been developed and verified for 1-g response by comparison with available experimental data. The zero-g simulations of two Skylab experiments are discussed.

Croston, R. C.↗

A generalized multi-resolution expansion for uncertainty propagation with application to cardiovascular modeling

Computational models are used in a variety of fields to improve our understanding of complex physical phenomena. Recently, the realism of model predictions has been greatly enhanced by transitioning from deterministic to stochastic frameworks, where the effects of the intrinsic variability in parameters, loads, constitutive properties, model geometry and other quantities can be more naturally included. A general stochastic system may be characterized by a large number of arbitrarily distributed and correlated random inputs, and a limited support response with sharp gradients or event discontinuities. This motivates continued research into novel adaptive algorithms for uncertainty propagation, particularly those handling high dimensional, arbitrarily distributed random inputs and non-smooth stochastic responses. Here, we generalize a previously proposed multi-resolution approach to uncertainty propagation to develop a method that improves computational efficiency, can handle arbitrarily distributed random inputs and non-smooth stochastic responses, and naturally facilitates adaptivity, i.e., the expansion coefficients encode information on solution refinement. Our approach relies on partitioning the stochastic space into elements that are subdivided along a single dimension, or, in other words, progressive refinements exhibiting a binary tree representation. We also show how these binary refinements are particularly effective in avoiding the exponential increase in the multi-resolution basis cardinality and significantly reduce the regression complexity for moderate to high dimensional random inputs. The performance of the approach is demonstrated through previously proposed uncertainty propagation benchmarks and stochastic multi-scale finite element simulations in cardiovascular flow.

59 BASIC BIOLOGICAL SCIENCES↗

Machine learning in cardiovascular flows modeling: Predicting arterial blood pressure from non-invasive 4D flow MRI data using physics-informed neural networks

Advances in computational science offer a principled pipeline for predictive modeling of cardiovascular flows and aspire to provide a valuable tool for monitoring, diagnostics and surgical planning. Such models can be nowadays deployed on large patient-specific topologies of systemic arterial networks and return detailed predictions on flow patterns, wall shear stresses, and pulse wave propagation. However, their success heavily relies on tedious pre-processing and calibration procedures that typically induce a significant computational cost, thus hampering their clinical applicability. Here, we put forth a machine learning framework that enables the seamless synthesis of non-invasive in-vivo measurement techniques and computational flow dynamics models derived from first physical principles. We illustrate this new paradigm by showing how one-dimensional models of pulsatile flow can be used to constrain the output of deep neural networks such that their predictions satisfy the conservation of mass and momentum principles. Once trained on noisy and scattered clinical data of flow and wall displacement, these networks can return physically consistent predictions for velocity, pressure and wall displacement pulse wave propagation, all without the need to employ conventional simulators. A simple post-processing of these outputs can also provide a relatively cheap and effective way for estimating Windkessel model parameters that are required for the calibration of traditional computational models. Finally, the effectiveness of the proposed techniques is demonstrated through a series of prototype benchmarks, as well as a realistic clinical case involving in-vivo measurements near the aorta/carotid bifurcation of a healthy human subject.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Model-based parameter estimation using cardiovascular response to orthostatic stress

This paper presents a cardiovascular model that is capable of simulating the short-term (< or approximately equal to 3 min) transient hemodynamic response to gravitational stress and a gradient-based optimization method that allows for the automated estimation of model parameters from simulated or experimental data. We perform a sensitivity analysis of the transient heart rate response to determine which parameters of the model impact the heart rate dynamics significantly. We subsequently include only those parameters in the estimation routine that impact the transient heart rate dynamics substantially. We apply the estimation algorithm to both simulated and real data and showed that restriction to the 20 most important parameters does not impair our ability to match the data.

Non-NASA Center↗

A cardiovascular system model for lower-body negative pressure response

Mathematical models used to study complex physiological control systems are discussed. Efforts were made to modify a model of the cardiovascular system for use in studying lower body negative pressure. A computer program was written which allows orderly, straightforward expansion to include exercise, metabolism (thermal stress), respiration, and other body functions.

Mitchell, B. A., Jr.↗

Relationship between systolic and diastolic function with improvements in forward stroke volume following reduction in mitral regurgitation

Efforts to improve mitral regurgitation (MR) are often performed in conjunction with coronary revascularization. However, the independent effects of a reduced MR area (MRa) are difficult to quantify. Using a previously developed cardiovascular model, ventricular contractility (elastance 1-8 mmHg/ml) and relaxation (tau: 40-150 msec) were independently adjusted for four grades of MR orifice areas (0.0 to 0.8 cm2). Improvements in forward stroke volume (fSV) were determined for the permutations of reduced MRa. For all conditions, LV end-diastolic pressure and volumes ranged from 7.3-24.2 mmHg and 64.8-174.3 ml, respectively. Overall, fSV ranged from 36.0-89.4 (mean: 64.2 +/- 12.8) ml, improved between 6.4 and 35.3% (mean: 15.6 +/- 8.1%), and was best predicted by (r=0.97, p<0.01) %delta(fSV)[correction of fVS]=34[MRa initial] - 46[MRa final] -0.5[elastance]. Reduced MRa, independent of relaxation and minimally influence by contractility, yield improved fSVs.

NASA Discipline Cardiopulmonary↗

Respiratory sinus arrhythmia: time domain characterization using autoregressive moving average analysis

Fourier-based techniques are mathematically noncausal and are therefore limited in their application to feedback-containing systems, such as the cardiovascular system. In this study, a mathematically causal time domain technique, autoregressive moving average (ARMA) analysis, was used to parameterize the relations of respiration and arterial blood pressure to heart rate in eight humans before and during total cardiac autonomic blockade. Impulse-response curves thus generated showed the relation of respiration to heart rate to be characterized by an immediate increase in heart rate of 9.1 +/- 1.8 beats.min-1.l-1, followed by a transient mild decrease in heart rate to -1.2 +/- 0.5 beats.min-1.l-1 below baseline. The relation of blood pressure to heart rate was characterized by a slower decrease in heart rate of -0.5 +/- 0.1 beats.min-1.mmHg-1, followed by a gradual return to baseline. Both of these relations nearly disappeared after autonomic blockade, indicating autonomic mediation. Maximum values obtained from the respiration to heart rate impulse responses were also well correlated with frequency domain measures of high-frequency "vagal" heart rate control (r = 0.88). ARMA analysis may be useful as a time domain representation of autonomic heart rate control for cardiovascular modeling.

NASA Discipline Regulatory Physiology↗

Computational modeling of cardiovascular response to orthostatic stress

The objective of this study is to develop a model of the cardiovascular system capable of simulating the short-term (< or = 5 min) transient and steady-state hemodynamic responses to head-up tilt and lower body negative pressure. The model consists of a closed-loop lumped-parameter representation of the circulation connected to set-point models of the arterial and cardiopulmonary baroreflexes. Model parameters are largely based on literature values. Model verification was performed by comparing the simulation output under baseline conditions and at different levels of orthostatic stress to sets of population-averaged hemodynamic data reported in the literature. On the basis of experimental evidence, we adjusted some model parameters to simulate experimental data. Orthostatic stress simulations are not statistically different from experimental data (two-sided test of significance with Bonferroni adjustment for multiple comparisons). Transient response characteristics of heart rate to tilt also compare well with reported data. A case study is presented on how the model is intended to be used in the future to investigate the effects of post-spaceflight orthostatic intolerance.

Flight Experiment↗

User's instructions for the cardiovascular Walters model

The model is a combined, steady-state cardiovascular and thermal model. It was originally developed for interactive use, but was converted to batch mode simulation for the Sigma 3 computer. The model has the purpose to compute steady-state circulatory and thermal variables in response to exercise work loads and environmental factors. During a computer simulation run, several selected variables are printed at each time step. End conditions are also printed at the completion of the run.

Croston, R. C.↗

Computer model of cardiovascular control system responses to exercise

Approaches of systems analysis and mathematical modeling together with computer simulation techniques are applied to the cardiovascular system in order to simulate dynamic responses of the system to a range of exercise work loads. A block diagram of the circulatory model is presented, taking into account arterial segments, venous segments, arterio-venous circulation branches, and the heart. A cardiovascular control system model is also discussed together with model test results.

Croston, R. C.↗

Integration of the Cardiovascular Risk Model Astro-CHARM in the NASA Radiation Risk Model

Space radiation poses an increased risk for cardiovascular diseases (CVD) during and after spaceflight, that should be quantified to plan future space missions such as the flight to Mars. The radiation-induced CVD risk is evaluated using a linear no-threshold dose response excess relative risk (ERR) model, so that the risk is function of the radiation dose and of the background (i.e., non-exposed) incidence rate. The background CVD risk can be evaluated using clinical prediction models (CPMs). The first CPMs developed in the 1960’s have identified CVD risk factors such as blood pressure, diabetes, cholesterol, and smoking. In this work, the steps used to integrate the CVD risk provided by a CPM into the NASA Radiation Risk Model are described. Simulation results calculated using available data for relevant mission scenarios are also shown, and the challenges in CVD risk predictions are discussed.

Space radiation↗

Multilevel and multifidelity uncertainty quantification for cardiovascular hemodynamics

Standard approaches for uncertainty quantification in cardiovascular modeling pose challenges due to the large number of uncertain inputs and the significant computational cost of realistic three-dimensional simulations. Here, we propose an efficient uncertainty quantification framework utilizing a multilevel multifidelity Monte Carlo (MLMF) estimator to improve the accuracy of hemodynamic quantities of interest while maintaining reasonable computational cost. This is achieved by leveraging three cardiovascular model fidelities, each with varying spatial resolution to rigorously quantify the variability in hemodynamic outputs. We employ two low-fidelity models (zero- and one-dimensional) to construct several different estimators. Our goal is to investigate and compare the efficiency of estimators built from combinations of these two low-fidelity model alternatives and our high-fidelity three-dimensional models. We demonstrate this framework on healthy and diseased models of aortic and coronary anatomy, including uncertainties in material property and boundary condition parameters. Our goal is to demonstrate that for this application it is possible to accelerate the convergence of the estimators by utilizing a MLMF paradigm. Therefore, we compare our approach to single fidelity Monte Carlo estimators and to a multilevel Monte Carlo approach based only on three-dimensional simulations, but leveraging multiple spatial resolutions. We demonstrate significant, on the order of 10 to 100 times, reduction in total computational cost with the MLMF estimators. We also examine the differing properties of the MLMF estimators in healthy versus diseased models, as well as global versus local quantities of interest. As expected, global quantities such as outlet pressure and flow show larger reductions than local quantities, such as those relating to wall shear stress, as the latter rely more heavily on the highest fidelity model evaluations. Similarly, healthy models show larger reductions than diseased models. In all cases, our workflow coupling Dakota’s MLMF estimators with the SimVascular cardiovascular modeling framework makes uncertainty quantification feasible for constrained computational budgets.

59 BASIC BIOLOGICAL SCIENCES↗

Clinical models of cardiovascular regulation after weightlessness

After several days in microgravity, return to earth is attended by alterations in cardiovascular function. The mechanisms underlying these effects are inadequately understood. Three clinical disorders of autonomic function represent possible models of this abnormal cardiovascular function after spaceflight. They are pure autonomic failure, baroreflex failure, and orthostatic intolerance. In pure autonomic failure, virtually complete loss of sympathetic and parasympathetic function occurs along with profound and immediate orthostatic hypotension. In baroreflex failure, various degrees of debuffering of blood pressure occur. In acute and complete baroreflex failure, there is usually severe hypertension and tachycardia, while with less complete and more chronic baroreflex impairment, orthostatic abnormalities may be more apparent. In orthostatic intolerance, blood pressure fall is minor, but orthostatic symptoms are prominent and tachycardia frequently occurs. Only careful autonomic studies of human subjects in the microgravity environment will permit us to determine which of these models most closely reflects the pathophysiology brought on by a period of time in the microgravity environment.

Review, Tutorial↗

User's instructions for the high speed version of the cardiovascular exercise model

A mathematical model and digital computer simulation of the human cardiovascular system and its controls were developed to simulate transient responses to bicycle ergometer exercise. The purpose of the model was to provide a method to analyze cardiovascular control hypotheses which cannot be easily tested in an animal or human or in a spaceflight environment.

Croston, R. C.↗