Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

CO2 Flux Estimation Errors Associated with Moist Atmospheric Processes

Vertical transport by moist sub-grid scale processes such as deep convection is a well-known source of uncertainty in CO2 source/sink inversion. However, a dynamical link between vertical transport, satellite based retrievals of column mole fractions of CO2, and source/sink inversion has not yet been established. By using the same offline transport model with meteorological fields from slightly different data assimilation systems, we examine sensitivity of frontal CO2 transport and retrieved fluxes to different parameterizations of sub-grid vertical transport. We find that frontal transport feeds off background vertical CO2 gradients, which are modulated by sub-grid vertical transport. The implication for source/sink estimation is two-fold. First, CO2 variations contained in moist poleward moving air masses are systematically different from variations in dry equatorward moving air. Moist poleward transport is hidden from orbital sensors on satellites, causing a sampling bias, which leads directly to small but systematic flux retrieval errors in northern mid-latitudes. Second, differences in the representation of moist sub-grid vertical transport in GEOS-4 and GEOS-5 meteorological fields cause differences in vertical gradients of CO2, which leads to systematic differences in moist poleward and dry equatorward CO2 transport and therefore the fraction of CO2 variations hidden in moist air from satellites. As a result, sampling biases are amplified and regional scale flux errors enhanced, most notably in Europe (0.43+/-0.35 PgC /yr). These results, cast from the perspective of moist frontal transport processes, support previous arguments that the vertical gradient of CO2 is a major source of uncertainty in source/sink inversion.

moist atmospheric processes↗

Effect of fluroine content, atmosphere, and burnishing technique on the lubricating properties of graphite fluoride

Eight different graphite fluoride compounds with fluorine to carbon ratios varying from x = 0.25 to 1.1 were evaluated as burnished films in order to determine the effect of fluorine content on the solid lubricant properties of graphite fluoride. For comparison, similar experiments were conducted on graphite burnished films. It was found that even a small amount of fluorine in graphite fluoride (CF0.25)n improved the lubricating properties of graphite. However, such factors as burnishing atmosphere, burnishing technique, test atmosphere, and specimen temperature affected the results as much as varying the fluorine to carbon ratio of the compound. Best life was found for films that were machined burnished in moist air and tested in moist air.

Fusaro, R. L.↗

Graphite fluoride lubrication: The effect of fluorine content, atmosphere, and burnishing technique

Eight different graphite fluoride compounds with fluorine to carbon ratios varying from x = 0.25 to 1.1 were evaluated as burnished films in order to determine the effect of fluorine content on the solid lubricant properties of graphite fluoride. For comparison, similar experiments were conducted on graphite burnished films. It was found that even a small amount of fluorine in graphite fluoride (CF sub 0.25) sub n improved the lubricating properties of graphite. Such factors as burnishing atmosphere, burnishing technique, test atmosphere, and specimen temperature affected the results as much as varying the fluorine to carbon ratio of the compound. Best life was found for films that were machine-burnished in moist air and tested in moist air.

Fusaro, R. L.↗

Graphite fluoride lubrication - The effect of fluorine content, atmosphere, and burnishing technique

Eight different graphite fluoride compounds with fluorine to carbon ratios varying from 0.25 to 1.1 were evaluated as burnished films in order to determine the effect of fluorine content on the solid lubricant properties of graphite fluoride. For comparison, similar experiments were conducted on graphite burnished films. It was found that even a small amount of fluorine in graphite fluoride with fluorine to carbon ratio of 0.25 improved the lubricating properties of graphite. However, such factors as burnishing atmosphere, burnishing technique, test atmosphere, and specimen temperature affected the results as much as varying the fluorine to carbon ratio of the compound. Best life was found for films that were machine-burnished in moist air and tested in moist air.

Fusaro, R. L.↗

Aerosol distributions and an arctic aerosol front during AGASP - Norwegian Arctic

Vertical profiles of aerosol characteristics obtained near Svalbard, Norway, during the Arctic Gas and Aerosol Sampling Program indicate that high aerosol concentrations and strong visible haze were distributed throughout the troposphere. Layers of Arctic haze were observed in both dry air and moist air. A research flight on March 31, 1983, crossed a previously undocumented Arctic aerosol front structure. Condensation nucleus concentrations of 450/cu cm within the polluted continental air mass south of the front decreased to 80/cu cm within the clean Arctic air north of the front. Aerosols above the Aitken size range decreased one order of magnitude in both number and mass across this same air mass boundary.

Ratz, W. E.↗

Elevated temperature cracking of RSP aluminum alloy 8009 - Characterization of the environmental influence

Degradation of the material properties of the Al alloy is examined to determine the effects of moist air and predissolved hydrogen on elevated-temperature fatigue and fracture resistance. Experiments are conducted at 175 C in both moist air and high vacuum with as-processed specimens and specimens that are vacuum-heat-treated. Fracture mechanics characterizations are made for initiation and propagation fracture toughnesses during rising load, fatigue-crack propagation kinetics, and sustained-load crack-growth rates. Time-dependent embrittlement at intermediate temperatures is identified in both plate and extrusion samples of the Al-Fe-Si-V alloy 8009. Intermediate temperature cracking is found to be the same for each case in both vacuum and moist air, and the vacuum heat treatment does not significantly affect the results.

Porr, William C., Jr.↗

Northern hemisphere mid-stratosphere vortex processes diagnosed from H2O, N2O and potential vorticity

Microwave Limb Sounder (MLS) H2O Cryogenic Limb Array Etalon Spectrometer (CLAES) N2O and potential vorticity calculated from UK Meteorological Office data are used to study mid-stratospheric vortex processes in the northern hemisphere winter of 1991-1992. Areas of moist air (at approx. 20 hPa) and N2O-poor air (at approx. 10hPa) are well-correlated with high values of potential vorticity and there is little or no large scale mixing across the vortex edge. We find evidence for the descent of relatively dry mesospheric air to the 840 K (approx. 10 hPa) level, as well as descent of moist air from the upper stratosphere to the 655 K (approx. 20 hPa) level. A reduction in the areas of the vortex and both the moist and H2O-poor regions is observed and there is evidence of moist and N2O-poor air parcels being extruded from the vortex.

Lahoz, W. A.↗

Empirical relationships among atmospheric variables from rawinsonde and field data as surrogates for AVIRIS measurements: Estimation of regional land surface evapotranspiration

Empirical relationships between variables are ways of securing estimates of quantities difficult to measure by remote sensing methods. The use of empirical functions was explored between: (1) atmospheric column moisture abundance W (gm H2O/cm(sup 2) and surface absolute water vapor density rho(q-bar) (gm H2O/cm(sup 3), with rho density of moist air (gm/cm(sup 3), q-bar specific humidity (gm H2O/gm moist air), and (2) column abundance and surface moisture flux E (gm H2O/(cm(sup 2)sec)) to infer regional evapotranspiration from Airborne Visible/Infrared Imaging Spectrometers (AVIRIS) water vapor mapping data. AVIRIS provides, via analysis of atmospheric water absorption features, estimates of column moisture abundance at very high mapping rate (at approximately 100 km(sup 2)/40 sec) over large areas at 20 m ground resolution.

Conel, James E.↗

Springtime stratospheric water vapour in the Southern Hemisphere as measured by MLS

The effects of the break-up of the Antarctic vortex on the water vapor distribution are studied using MLS measurements of water vapor made during September 1991 and November 1991. In early November at 22 hPa a moist area is found within the polar vortex, consistent with an observed descent of order 10 km and strong radiative cooling. As the vortex erodes (beginning of November 1991), parcels of moist air become detached from the edge of the vortex and mix rapidly (within 2-3 days) with drier mid-latitude air. When the vortex breaks up (mid-November), larger parcels of moist air from both the edge and the inner vortex migrate to mid-latitudes. These parcels have a longer lifetime than those produced by vortex erosion, probably because they are correlated with higher potential vorticity gradients. The break-up of the vortex is accompanied by a mean adiabatic equatorward transport resulting in a significant increase in midstratospheric water vapor values at mid-latitudes in late spring.

Harwood, R. S.↗

Friction behavior of glass and metals in contact with glass in various environments

Sliding friction experiments have been conducted for heat-resistant glass and metals in contact with glass. These experiments were conducted in various environments including vacuum, moist air, dry air, octane, and stearic acid in hexadecane. Glass exhibited a higher friction force in moist air than it did in vacuum when in sliding contact with itself. The metals, aluminum, iron, and gold, all exhibited the same friction coefficient when sliding on glass in vacuum as glass sliding on glass. Gold-to-glass contacts were extremely sensitive to the environment despite the relative chemical inertness of gold.

Buckley, D. H.↗

Water vapor weathering of Taurus-Littrow orange soil - A pore-structure analysis

A pore-volume analysis was performed on water vapor adsorption data previously obtained on a fresh sample of Taurus-Littrow orange soil, and the analysis was repeated on the same sample after its exposure to moist air for a period of approximately six months. The results indicate that exposure of an outgassed sample to high relative pressures of water vapor can result in the formation of substantial micropore structure, the precise amount being dependent on the sample pretreatment, particularly the outgassing temperature. Micropore formation is explained in terms of water penetration into surface defects. In contrast, long-term exposure to moist air at low relative pressures appears to reverse the process with the elimination of micropores and enlargement of mesopores possibly through surface diffusion of metastable adsorbent material. The results are considered with reference to the storage of lunar samples.

Cadenhead, D. A.↗

Acoustic Humidity Sensor

Industrial humidity sensor measures volume fraction of water in air via its effect on speed of sound. Only portion of sensor exposed to sensed atmosphere is pair of stainless-steel tubes, one containing dry air and other containing moist air. Counters measure intervals between reflected pulses. Sensor rugged enough for use in harsh environments like those used to control drying of paper in paper mills, where most humidity sensors do not survive.

Shakkottai, Parthasarathy↗

Moist convection on Neptune

A study of methane moist convection on Neptune examines the stability conditions which initiate moist convection of methane clouds. Temperature lapse rates that are unstable to moist convection are subadiabatic by a factor of two or more, while adiabatic and superadiabatic lapse rates are stable. In the observed Neptune temperature structure, vertical velocities greater than 40 m/s are required to lift moist air above the stable region and initiate moist convection. Alternatively, moist convection could be initiated by air that is slightly drier than its surroundings. Moist convective clouds achieve altitudes up to 100 mb, thereby exceeding the temperature minimum and depositing methane in the Neptune stratosphere. At least 2000 such clouds penetrate the Neptune stratosphere/hour.

Stoker, Carol R.↗

Portable breathing system

A semiclosed-loop rebreathing system is discussed for use in a hostile environment. A packed bed regenerative heat exchanger providing two distinct temperature humidity zones of breathing gas with one zone providing cool, relatively dry air and the second zone providing hot, moist air is described.

Lovell, J. S.↗

Boundary lubrication of formulated C-ethers in air to 300 C

Friction and wear measurements were made in dry and moist air on CVM M-50 steel lubricated with six C-ether formulations containing phosphorus ester and organic acid additives. Results were compared to those obtained with a formulated Type 2 ester and the C-ether base fluid. A ball-on-disk sliding friction apparatus was used. Experimental conditions were a 1-kilogram load, 17 meter-per-minute (100 rpm) surface speed, and a 25 to 300 C disk temperature range. The C-ether base fluid and the C-ether formulations yielded lower wear than the ester under most test conditions. The C-ether formulations exhibited higher friction coefficients than the ester from 150 to 300 C and similar or lower values from 25 to 150 C.

Jones, W. R., Jr.↗

A GCM Study of Responses of the Atmospheric Water Cycle of West Africa and the Atlantic to Saharan Dust Radiative Forcing

The responses of the atmospheric water cycle and climate of West Africa and the Atlantic to radiative forcing of Saharan dust are studied using the NASA finite volume general circulation model (fvGCM), coupled to a mixed layer ocean. We find evidence of an "elevated heat pump" (EHP) mechanism that underlines the responses of the atmospheric water cycle to dust forcing as follow. During the boreal summerr, as a result of large-scale atmospheric feedback triggered by absorbing dust aerosols, rainfall and cloudiness are ehanIed over the West Africa/Eastern Atlantic ITCZ, and suppressed over the West Atlantic and Caribbean region. Shortwave radiation absorption by dust warms the atmosphere and cools the surface, while longwave has the opposite response. The elevated dust layer warms the air over West Africa and the eastern Atlantic. As the warm air rises, it spawns a large-scale onshore flow carrying the moist air from the eastern Atlantic and the Gulf of Guinea. The onshore flow in turn enhances the deep convection over West Africa land, and the eastern Atlantic. The condensation heating associated with the ensuing deep convection drives and maintains an anomalous large-scale east-west overturning circulation with rising motion over West Africa/eastern Atlantic, and sinking motion over the Caribbean region. The response also includes a strengthening of the West African monsoon, manifested in a northward shift of the West Africa precipitation over land, increased low-level westerlies flow over West Africa at the southern edge of the dust layer, and a near surface westerly jet underneath the dust layer overr the Sahara. The dust radiative forcing also leads to significant changes in surface energy fluxes, resulting in cooling of the West African land and the eastern Atlantic, and warming in the West Atlantic and Caribbean. The EHP effect is most effective for moderate to highly absorbing dusts, and becomes minimized for reflecting dust with single scattering albedo at0.95 or higher.

Lau, K. M.↗

Asian Summer Monsoon Anomalies Induced by Aerosol Direct Forcing: The Role of the Tibetan Plateau

In this paper we present results of a numerical study using the NASA finite-volume GCM to elucidate a plausible mechanism for aerosol impact on the Asian summer monsoon involving interaction with physical processes over the Tibetan Plateau (TP). During the premonsoon season of March April, dusts from the deserts of western China, Afghanistan/Pakistan, and the Middle East are transported into and stacked up against the northern and southern slopes of the TP. The absorption of solar radiation by dust heats up the elevated surface air over the slopes. On the southern slopes, the atmospheric heating is reinforced by black carbon from local emission. The heated air rises via dry convection, creating a positive temperature anomaly in the mid-to-upper troposphere over the TP relative to the region to the south. In May through early June in a manner akin to an elevated heat pump , the rising hot air forced by the increasing heating in the upper troposphere, draws in warm and moist air over the Indian subcontinent, setting the stage for the onset of the South Asia summer monsoon. Our results suggest that increased dust loading coupled with black carbon emission from local sources in northern India during late spring may lead to an advance of the rainy periods and subsequently an intensification of the Indian summer monsoon. The enhanced rainfall over India is associated with the development of an aerosol-induced large-scale sea level pressure anomaly pattern, which causes the East Asia (Mei-yu) rain belt to shift northwestward, suppressing rainfall over East Asia and the adjacent oceanic regions.

Lau, K. M.↗

Convective Impact on the Global Lower Stratospheric Water Vapor Budget

Water vapor in the stratosphere is primarily controlled by temperatures in the tropical upper troposphere and lower stratosphere. However, the direct impact of deep convection on the global lower stratospheric water vapor budget is still an actively debated issue. Two complementary modeling approaches are used to investigate the convective impact in boreal winter and summer. Convective influence is diagnosed by tracing trajectories through convective cloud top altitude fields derived from global rainfall and brightness temperature data. Backward trajectory model simulations coupled with a detailed treatment of cloud microphysical processes indicate that convection moistens the global lower stratosphere by approximately 0.3 ppmv in boreal winter and summer 2010. The diurnal peak in convection is responsible for about half of the total convective moistening during winter and nearly all of the convective moistening during summer. Deep convective clouds overshooting the tropopause have relatively minor effect on global lower stratospheric water vapor. A forward trajectory model coupled with a simplified cloud module is used to estimate the relative magnitude of the interannual variability of the convective impact. Combining the results from the two models, we find that the convective impact on the global lower stratospheric water vapor during 2006-2016 is approximately 0.3 ppmv with year-to-year variations of up to 0.1 ppmv. An important mechanism of convective hydration of the lower stratosphere is via the detrainment of saturated air and ice into the tropical uppermost troposphere and the subsequent upward transport of some of these moist air parcels across relatively warm and subsaturated tropopause.