Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monitoring, Physiologic/instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

MIMIC II: a massive temporal ICU patient database to support research in intelligent patient monitoring

Development and evaluation of Intensive Care Unit (ICU) decision-support systems would be greatly facilitated by the availability of a large-scale ICU patient database. Following our previous efforts with the MIMIC (Multi-parameter Intelligent Monitoring for Intensive Care) Database, we have leveraged advances in networking and storage technologies to develop a far more massive temporal database, MIMIC II. MIMIC II is an ongoing effort: data is continuously and prospectively archived from all ICU patients in our hospital. MIMIC II now consists of over 800 ICU patient records including over 120 gigabytes of data and is growing. A customized archiving system was used to store continuously up to four waveforms and 30 different parameters from ICU patient monitors. An integrated user-friendly relational database was developed for browsing of patients' clinical information (lab results, fluid balance, medications, nurses' progress notes). Based upon its unprecedented size and scope, MIMIC II will prove to be an important resource for intelligent patient monitoring research, and will support efforts in medical data mining and knowledge-discovery.

NASA Discipline Cardiopulmonary↗

Effects of Command and Control Vehicle (C2V) operational environment on soldier health and performance

The purpose of this project was to use NASA technology to assist the US Army in the assessment of motion sickness incidences and effects on soldier performance and mood states within the Command and Control Vehicle (C2V). Specific objectives were (1) to determine if there was a significant difference between three internal configurations of the C2V and/or between seats within these vehicles; (2) to determine if there was a significant difference between the park, move, or short-halt field conditions; and (3) to validate a method of converging indicators developed by NASA to assess environmental impact of long duration spaceflight on crewmembers, using a large sample of subjects under ground-based operational conditions.

NASA Center ARC↗

An objective determination of +Gz acceleration tolerance

Until recently, human +Gz acceleration tolerance has relied solely on subjective criteria relating to loss of vision. By use of newly developed noninvasive instrumentation using a transcutaneous Doppler flow system, objective end point criteria have been developed based on measured blood flow to the head. The system consists of miniature 8 MHz Doppler sensors (2 x 1 x 0.5 cm) placed on the forehead over both frontal branches of the temporal arteries to detect blood flow velocity from back scattered ultrasound. Its use has allowed for correlation of altered, decreased and actual reversal of eye level blood flow with subsequent central light loss. Over 100 subjects have now been studied during more than 2,000 centrifuge runs. Objective changes in temporal artery flow velocity consistently preceded visual degradation for each subject during all acceleration profiles. No subject has gone unconscious without first exhibiting a minimum 6 sec of total flow cessation. Retrograde flow followed by complete flow cessation always preceded central light loss. Results indicate that this method can be successfully used with a wide variety of tasks during exposure to +Gz acceleration. It is recommended for use during evaluation of protective maneuvers or devices on the centrifuge or during actual flight in high performance aircraft. It may also serve as a potential safety monitor during space Shuttle re-entry if there is doubt about a passenger's cardiovascular status.

Unconsciousness/prevention & control↗

Basic principles for measurement of intramuscular pressure

We review historical and methodological approaches to measurements of intramuscular pressure (IMP) in humans. These techniques provide valuable measures of muscle tone and activity as well as diagnostic criteria for evaluation of exertional compartment syndrome. Although the wick and catheter techniques provide accurate measurements of IMP at rest, their value for exercise studies and diagnosis of exertional compartment syndrome is limited because of low frequency response and hydrostatic (static and inertial) pressure artifacts. Presently, most information on diagnosis of exertional compartment syndromes during dynamic exercise is available using the Myopress catheter. However, future research and clinical diagnosis using IMP can be optimized by the use of a miniature transducer-tipped catheter such as the Millar Mikro-tip.

NASA Center ARC↗

Noninvasive measurement of pulsatile intracranial pressure using ultrasound

The present study was designed to validate our noninvasive ultrasonic technique (pulse phase locked loop: PPLL) for measuring intracranial pressure (ICP) waveforms. The technique is based upon detecting skull movements which are known to occur in conjunction with altered intracranial pressure. In bench model studies, PPLL output was highly correlated with changes in the distance between a transducer and a reflecting target (R2 = 0.977). In cadaver studies, transcranial distance was measured while pulsations of ICP (amplitudes of zero to 10 mmHg) were generated by rhythmic injections of saline. Frequency analyses (fast Fourier transformation) clearly demonstrate the correspondence between the PPLL output and ICP pulse cycles. Although theoretically there is a slight possibility that changes in the PPLL output are caused by changes in the ultrasonic velocity of brain tissue, the decreased amplitudes of the PPLL output as the external compression of the head was increased indicates that the PPLL output represents substantial skull movement associated with altered ICP. In conclusion, the ultrasound device has sufficient sensitivity to detect transcranial pulsations which occur in association with the cardiac cycle. Our technique makes it possible to analyze ICP waveforms noninvasively and will be helpful for understanding intracranial compliance and cerebrovascular circulation.

NASA Center ARC↗

Spectral indices of cardiovascular adaptations to short-term simulated microgravity exposure

We investigated the effects of exposure to microgravity on the baseline autonomic balance in cardiovascular regulation using spectral analysis of cardiovascular variables measured during supine rest. Heart rate, arterial pressure, radial flow, thoracic fluid impedance and central venous pressure were recorded from nine volunteers before and after simulated microgravity, produced by 20 hours of 6 degrees head down bedrest plus furosemide. Spectral powers increased after simulated microgravity in the low frequency region (centered at about 0.03 Hz) in arterial pressure, heart rate and radial flow, and decreased in the respiratory frequency region (centered at about 0.25 Hz) in heart rate. Reduced heart rate power in the respiratory frequency region indicates reduced parasympathetic influence on the heart. A concurrent increase in the low frequency power in arterial pressure, heart rate, and radial flow indicates increased sympathetic influence. These results suggest that the baseline autonomic balance in cardiovascular regulation is shifted towards increased sympathetic and decreased parasympathetic influence after exposure to short-term simulated microgravity.

NASA Discipline Cardiopulmonary↗

Applied superconductivity and superfluidity for the exploration of the Moon and Mars

We discuss how superconductivity and superfluidity can be applied to solve the challenges in the exploration of the Moon and Mars. High sensitivity instruments using phenomena of superconductivity and superfluidity can potentially make significant contributions to the fields of navigation, automation, habitation, and resource location. Using the quantum nature of superconductivity, lightweight and very sensitive diagnostic tools can be made to monitor the health of astronauts. Moreover, the Moon and Mars offer a unique environment for scientific exploration. We also discuss how powerful superconducting instruments may enable scientists to seek answers to several profound questions about nature. These answers will not only deepen our appreciation of the universe, they may also open the door to paradigm-shifting technologies. c2005 COSPAR. Published by Elsevier Ltd. All rights reserved.

NASA Center JPL↗