Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo Methods, Neutrons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

An Investigation of the Performance of the Unified Monte Carlo Method of Neutron Cross Section Data Evaluation

The Unified Monte Carlo method (UMC) has been suggested to avoid certain limitations and approximations inherent to the well-known Generalized Least Squares (GLS) method of nuclear data evaluation. This contribution reports on an investigation of the performance of the UMC method in comparison with the GLS method. This is accomplished by applying both methods to simple examples with few input values that were selected to explore various features of the evaluation process that impact upon the quality of an evaluation. Among the issues explored are: i) convergence of UMC results with the number of Monte Carlo histories and the ranges of sampled values; ii) a comparison of Monte Carlo sampling using the Metropolis scheme and a brute force approach; iii) the effects of large data discrepancies; iv) the effects of large data uncertainties; v) the effects of strong or weak model or experimental data correlations; and vi) the impact of ratio data and integral data. Comparisons are also made of the evaluated results for these examples when the input values are first transformed to comparable logarithmic values prior to performing the evaluation. Some general conclusions that are applicable to more realistic evaluation exercises are offered.

99 GENERAL AND MISCELLANEOUS↗

Predicting deviations in ex-core detector response in Krsko NPP during an earthquake with Monte-Carlo neutron transport methods

To study the response of ex-core detectors during an earthquake, an approach using Monte Carlo code MCNP was developed. As a first step to predict the response of the ex-core detectors a detailed MCNP model of the Krsko reactor core was created. A detailed MCNP core model was used to calculate 3D power distributions inside the core. Calculated power distributions were verified by comparison to the CORD-2 calculations, which is currently used for core design calculation verification of the Krsko nuclear power plant. Due to the outside the core position of the neutron detectors, the hybrid code ADVANTG is used to generate weight windows to speed up neutron transport outside the reactor core. To be able to use ADVANTG, fixed neutron source had to be reconstructed from the criticality core calculation. It was found that the power range ex-core detector movement has a negligible effect on the value of the thermal neutron flux at the active part of the detector. However, the 5 cm radial movement of the intermediate-range detector leads to 7 % - 8 % change in thermal neutron flux within the active intermediate-range detector region. The analysis continued with the evaluation of the effect of core barrel movement on the ex-core detector response. It was determined that the 2 mm core barrel radial oscillation can lead to ∼ 4% change in thermal neutron flux within the active detector region. It was evaluated that reactor core movement inside the baffle can lead up to ∼ 1.9% and ∼ 1.3% deviation in power-range and intermediate-range detector signal respectively. Analysis showed that the mechanical movement of ex-core neutron detectors could not explain the fluctuations in the ex-core detector signal. However, combined core barrel and reactor core inside baffle oscillations could be a probable reason for the observed fluctuations in the ex-core detector signal during an earthquake. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Metropolis–Hastings Monte Carlo Method for Neutron Emissivity Tomographic Inversion in Tokamak Plasma

The article presents a new approach to plasma neutron emissivity reconstruction based on the Metropolis–Hastings Monte Carlo algorithm. The algorithm is based on a biased random walk. A dedicated computer code generates pseudo-random samples within the domain that contains the solution. The properly chosen objective function ensures convergence to the desired solution. The method allows to overcome the problem of trapping in local minima by accepting, with some finite probability, changes in the direction opposite to that indicated by the objective function. The developed method was tested using a synthetic data set. The results show that the method provides reliable reconstructions and thus can be used as an alternative or complementary method to the commonly applied ones. The method capabilities were also tested against noise present in the line-integrated projections.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron Spectra and H*(10) in a 15 MV Linac

Neutron spectra and the ambient dose equivalent were calculated inside the bunker of a 15 MV Varian linac model CLINAC iX. Calculations were carried out using Monte Carlo methods. Neutron spectra in the vicinity of isocentre show the presence of evaporation and knock-on neutrons produced by the source term, while epithermal and thermal neutron remain constant regardless the distance respect to isocentre, due to room return. Along the maze neutron spectra becomes softer as the detector moves along the maze. The ambient dose equivalent is decreased but do not follow the 1/r{sup 2} rule due to changes in the neutron spectra.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Calculation of Prompt Fission Neutron Lifetimes by the Monte Carlo Method

An algorithm for calculation of prompt fission neutron lifetimes in a nuclear reactor by the Monte Carlo method is described. Evaluation of the importance function is carried out with solution of the neutron transport equation without solving the adjoint equation. The results of the prompt neutron lifetime calculations performed within some critical experiments are presented and compared with the experimental results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uncertainty Analysis for a Criticality Benchmark [Slides]

This presentation discusses how KRUSTY was analyzed with LANL’s MCNP neutron transport code, Monte Carlo N-Particle. In the Monte Carlo method, neutrons are born in fission events and fly around the geometry having events (e.g., scatter, capture, fission, escape) according to the natural probabilities. “Natural probabilities” are given as neutron cross sections , which are measured and evaluated nuclear data. One of the goals of the benchmark project is to improve the nuclear cross sections (and the codes that use them). In this work, the response of interest is called k eff , which describes the neutron multiplication in a near critical system. Like most quantities, k eff is not measured directly; it is only inferred. In summation, MCNP results for k eff matched the measurements extremely well. The evaluated uncertainties are asymmetric and smaller than 0.00100 (e.g., + 0.00080 / – 0.00062). The largest uncertainties are due to alignment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uncertainty Analysis for a Criticality Benchmark [Slides]

This presentation discusses how KRUSTY was analyzed with LANL’s MCNP neutron transport code, Monte Carlo N-Particle. In the Monte Carlo method, neutrons are born in fission events and fly around the geometry having events (e.g., scatter, capture, fission, escape) according to the natural probabilities. “Natural probabilities” are given as neutron cross sections , which are measured and evaluated nuclear data. One of the goals of the benchmark project is to improve the nuclear cross sections (and the codes that use them). In this work, the response of interest is called k eff , which describes the neutron multiplication in a near critical system. Like most quantities, k eff is not measured directly; it is only inferred. In summation, MCNP results for k eff matched the measurements extremely well. The evaluated uncertainties are asymmetric and smaller than 0.00100 (e.g., + 0.00080 / – 0.00062). The largest uncertainties are due to alignment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measuring and monitoring KIPT Neutron Source Facility Reactivity

Argonne National Laboratory (ANL) of USA and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have been collaborating on developing and constructing a neutron source facility at Kharkov, Ukraine. The facility consists of an accelerator-driven subcritical system. The accelerator has a 100 kW electron beam using 100 MeV electrons. The subcritical assembly has k eff less than 0.98. To ensure the safe operation of this neutron source facility, the reactivity of the subcritical core has to be accurately determined and continuously monitored. A technique which combines the area-ratio method and the flux-to-current ratio method is purposed to determine the reactivity of the KIPT subcritical assembly at various conditions. In particular, the area-ratio method can determine the absolute reactivity of the subcritical assembly in units of dollars by performing pulsed-neutron experiments. It provides reference reactivities for the flux-to-current ratio method to track and monitor the reactivity deviations from the reference state while the facility is at other operation modes. Monte Carlo simulations are performed to simulate both methods using the numerical model of the KIPT subcritical assembly. It is found that the reactivities obtained from both the area-ratio method and the flux-to-current ratio method are spatially dependent on the neutron detector locations and types. Numerical simulations also suggest optimal neutron detector locations to minimize the spatial effects in the flux-to-current ratio method. The spatial correction factors are calculated using Monte Carlo methods for both measuring methods at the selected neutron detector locations. Monte Carlo simulations are also performed to verify the accuracy of the flux-to-current ratio method in monitoring the reactivity swing during a fuel burnup cycle.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measurement of DT and DD components in neutron spectrum with a double-crystal time-of-flight spectrometer

To investigate the deuteron and triton density ratio in core plasmas, a new methodology with measurement of tritium (DT) and deuterium (DD) neutron count rate ratio using a double-crystal time-of-flight (TOF) spectrometer is proposed. Multi-discriminator electronic circuits for the first and second detectors are used in addition to the TOF technique. The optimum arrangement of the detectors and discrimination window were examined considering the relations between the geometrical arrangement and deposited energy using a Monte Carlo Code, PHITS (Particle and Heavy Ion Transport Code System). An experiment to verify the calculations was performed using DD neutrons from an accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of new prompt fission neutron spectrum evaluations and the associated cross-correlations on critical assemblies using MCNP6 - 14385

Two recent re-evaluations of the neutron-induced prompt fission neutron spectrum (PFNS) of uranium and plutonium actinides have included some cross-correlated uncertainties that have not been released in a new nuclear data library. The first re-evaluation included cross-isotope correlations of the PFNS within each of the uranium and plutonium suites of actinides below the second-chance fission threshold. The second, more recent re-evaluation includes incident energy-dependent correlations of the {sup 239}Pu(n,f) PFNS. Both of these new evaluations and their cross-correlations, given the importance of these actinide quantities and because the impact of the incident energy-dependent correlations has never been studied previously, could have an impact on a variety of criticality safety applications. For example, the ke uncertainty due to the uranium PFNS uncertainties in the Big Ten critical assembly is underpredicted by ∼10% when the cross-isotope correlations in the uranium PFNS are ignored. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sensitivity studies to Support TEX critical experiments design

In the frame of the ongoing Thermal/Epithermal experiments program, supported by the DOE-NCSP, we are characterizing expected data with analysis of sensitivity coefficients to nuclear data. The computations were performed for detailed and simplified models of the experimental configurations in order to demonstrate their invariance with respect to small geometry variations. The sensitivity coefficients were computed with recently developed precise methodologies using Monte Carlo tools (MCNP-6.1, SCALE 6.1 and MORET 5.C.1) with the following nuclear data libraries: ENDF/B-VII.0, ENDF/B-VII.1, and JEFF3.1. Since the considered experiments are devoted to tantalum data validation, their neutronic characteristics are compared with the relevant integral experiment data collected in the OECD/NEA ICSBEP Handbook. Although analysis of sensitivity coefficients taken alone is insufficient for an entire assessment, we can conclude that TEX experimental results can fill gaps in the available benchmarks to facilitate quantification of uncertainty for plutonium containing systems with epithermal neutron spectra (e.g. wet plutonium-based powders). However, analysis of sensitivity profiles demonstrates that an advanced statistical methodology will be needed to fit tantalum nuclear data or to evaluate the associated uncertainties. (authors)

42 ENGINEERING↗

Neutronics Calculation Advances at Los Alamos: Manhattan Project to Monte Carlo

The history and advances of neutronics calculations at Los Alamos during the Manhattan Project through the present are reviewed. Substantial improvements to neutron diffusion methods and the invention of both the Monte Carlo neutron transport methods in 1947 and deterministic discrete ordinates Sn in 1953 were all made at Los Alamos just after the Manhattan Project. We briefly summarize early simpler and more approximate neutronics methods and then describe the need to better predict neutronics behavior through consideration of theoretical equations, models and algorithms, experimental measurements, and available computing capabilities and their limitations. This paper briefly covers key advances in deterministic methods during the Manhattan Project. These capabilities, coupled with increasing postwar defense needs and the invention of electronic computing with the Electronic Numeric Integrator and Computer, known as ENIAC, and the Mathematical Analyzer Numerical Integrator and Automatic Computer Model, known as MANIAC, led to the creation of Monte Carlo and deterministic discrete ordinates neutronics transport methods. We note the important role that the scientific comradery between the Los Alamos scientists played in the process. This paper briefly covers the early methods, algorithms, computers, and electronic and women pioneers that enabled Monte Carlo to spread to all areas of science. We focus heavily on these early developments and the subsequent creation of the MCNP® code, advances in its associated nuclear data, and its applications to problems of national defense at Los Alamos.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Explicit temperature treatment in Monte Carlo neutron tracking routines - First results

This article discusses the preliminary implementation of the new explicit temperature treatment method to the development version Monte Carlo reactor physics code Serpent 2 and presents the first practical results calculated using the method. The explicit temperature treatment method, as introduced in [1], is a stochastic method for taking the effect of thermal motion into account on-the-fly in a Monte Carlo neutron transport calculation. The method is based on explicit treatment of the motion of target nuclei at collision sites and requires cross sections at 0 K temperature only, regardless of the number of temperatures in the problem geometry. The method includes a novel capability of modelling continuous temperature distributions. Test calculations are performed for two test cases, a PWR pin-cell and a HTGR system. The resulting k{sub eff} and flux spectra are compared to a reference solution calculated using Serpent 1.1.16 with Doppler-broadening rejection correction [2]. The results are in very good agreement with the reference and also the increase in calculation time due to the new method is on acceptable level although not fully insignificant. On the basis of the current study, the explicit treatment method can be considered feasible for practical calculations. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

New capabilities of the MORET 6 Monte Carlo neutron transport code

The MORET code is a simulation tool that solves the transport equation for neutrons using the Monte Carlo method. It allows users to model complex three-dimensional geometrical configurations in a user-friendly way. New features have been introduced to extend the application field of MORET beyond the usual criticality calculations for which it has been initially designed. The most important change is the addition of an analog fixed source mode which allows studies of systems of any reactivity combined with very flexible outputs. Other useful improvements have been added concerning the geometric part, the fission matrix, the multigroup sensitivity coefficients and the outputs. This paper presents an overview of these new features. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Low-density neutron matter

The properties of low-density neutron matter are important for the understanding of neutron star crusts and the exterior of large neutron-rich nuclei. We examine various properties of dilute neutron matter using quantum Monte Carlo methods, with s- and p-wave terms in the interaction. Our results provide a smooth evolution of the equation of state and pairing gap from extremely small densities, where analytic expressions are available, up to the strongly interacting regime probed experimentally and described theoretically in cold atomic systems, where k{sub F}approx =0.5 fm{sup -1} and the pairing gap becomes of the order of magnitude of the Fermi energy. We also present results for the momentum distribution and pair distributions, displaying the same evolution from weak to strong coupling. Combined with previous quantum Monte Carlo and other calculations at moderate densities, these results provide strong constraints on the neutron matter equation of state up to saturation densities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗