A Verification of Flux Sensitivity Estimates Using the MCNP Tally Perturbation Tool

Nuclear data is commonly used in applications such as nuclear nonproliferation, safeguards, and criticality safety. More specifically, nuclear data is used in predictive simulation codes like the Monte-Carlo N-Particle (MCNP ® ) transport code, Serpent, and similar radiation transport codes. The improvement of nuclear data enables more precise and accurate simulations, which result in higher fidelity designs and reduced operational/procedural costs. Therefore, the improvement of nuclear data is of paramount importance across the nuclear community. Nuclear data is improved and validated through integral benchmark experiments. The design of benchmark experiments is an extensive process; therefore, these experiments are often optimized on multiple characteristics, including sensitivity to the nuclear data, during the design process. Sensitivity is a measure of how much a quantity changes due to changes in independent variables such as experimental configuration. An experimental design that has a larger sensitivity to the nuclear data of interest will have a larger impact on the accuracy and precision of the validated data. Past integral benchmark experiments have primarily used the effective multiplication factor ($k_{eff}$) as the predominant measured quantity; however, experiments designed with other quantities in mind would be able to optimize on validating different areas of the nuclear data. A primary goal of the EUCLID project is to design, constrain, and reduce compensating errors in experiments focused on quantities other than $k_{eff}$ to better validate nuclear data across the board. Currently, there is a capability in MCNP to easily calculate the sensitivity of $k_{eff}$ to specific nuclear data of numerous reactions types and isotopes (KSEN card); however, the sensitivity of other quantities must be estimated in more strenuous manners. For example, the perturbation feature (PERT card) of MCNP can be used to estimate first-order sensitivities of some response in fixed source simulations. A recent announcement revealed that the first- and second-order perturbation features in previous releases of MCNP contained a bug. It was identified that particles were being scored into the wrong energy bin. The bug is in the most recent public release (MCNP6.2); however, a patch has been added to the most up to date version (MCNP6.2.2) that has not been released publicly. A direct comparison of the PERT card results for an F4 (neutron flux averaged over a cell) tally before and after the patch are shown in figure 1. All simulations used in the sensitivity estimates in this report were performed with MCNP6.2.2. This work verifies the patched MCNP perturbation tool by comparing first order sensitivities made using the PERT card to estimates made using manual perturbation of the compact ENDF (ACE) files.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi-modal tomographic imaging system for poolside characterization of nuclear test fuels: Design considerations and studies

Testing and qualification of advanced nuclear fuels involves an iterative process of prototyping, in-pile irradiation testing, and in-situ or ex-situ examination. Fuel restructuring and fission product migration during burnup are among the most important aspects of fuel evolution that affect several important performance characteristics such as heat removal, accident tolerance, and fission product retention. Pool-side non-destructive characterization techniques provide fuel developers with tools to understand fuel evolution at different points of burnup. A design for a compact, submersible, and multi-modal gamma-ray tomography system for imaging irradiated nuclear fuel is presented here. Detector selection, collimator geometry and fabrication, mechanical design, imaging protocol and acquisition speed are discussed. Modeling calculations show that sub-millimeter resolution can be achieved in both transmission computed tomography images as well as in emission computed tomography images in a matter of hours. Several design compromises and fabrication challenges are discussed which should be taken into consideration for future submersible gamma-ray tomography instruments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison of active interrogation methods for source location in a scattering and absorbing medium, consisting of PGNAA, and an AmBe quasi-forward biased directional source

Source location of Special Nuclear Material (SNM) encompassing 95% 235 U and 239 Pu is identified by utilizing a directional source from Patent No: US20190013109A1 using Prompt Gamma Neutron Activation Analysis (PGNAA) and neutron spectroscopy simulated with Monte-Carlo N-Particle transport 6.2 (MCNP). BC-408, HPGe, LaBr 3 detector arrays were used to identify the location of the SNM using total counts incident on each detector, and PGNAA photopeaks from HPGe and LaBr 3 detector arrays in a polyethylene shield. The conducted simulations varied the volume and location of the SNM in the MCNP input files to observe how the source location method behaved. PGNAA photopeaks used for source identification include 61 keV from fission, 2.223 MeV prompt gamma from hydrogen, 511 keV annihilation, and a single and double escape peaks from the prompt gamma interaction from hydrogen. The capabilities of each detector systems to acquire well resolved photopeaks with a 1% relative error or less, and total relative error for F4 and F8 tallies were less than 0.015% relative error. Source predictions of the SNM with uneven amounts of polyethylene shielding between the source and detectors was observed to overpredict and give invalid source location predictions. Source locations of the SNM with even amounts of polyethylene material between the source and each detector were found to be valid. With a 1 Ci 241 Am source activity, it was determined that 1630 s were needed to obtain the results for each detector system with the quasi-forward directional AmBe source. Coupling source and material identification together would increase acquisition time but would only require one system to determine.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-purity germanium semiconductor modeling in the detector response function toolkit

In this study, we have extended the detector response function toolkit (DRiFT) to provide modeling capabilities of semiconductor sensors. DRiFT provides realistic nuclear instrumentation response by post-processing Monte-Carlo N-particle (MCNP®) radiation transport outputs. MCNP® is capable of modeling radiation transport in complex environments, but has limited detector physics and readout electronics modeling capabilities. Semiconductor detector response can be calculated with a high-fidelity for a flexible range of environments by utilizing MCNP® to simulate radiation interactions inside of detector volumes, and then using DRiFT to model charge transport and signal formation in the semiconductor, as well as the readout electronics. DRiFT models charge transport in the semiconductor, the preamplifier, shaping amplifier, pulse pile-up, and electronic noise to generate detector response. The semiconductor application in DRiFT can model a range of semiconductor materials, shapes, and sizes; and is demonstrated here for a large volume coaxial high-purity germanium (HPGe) detector. Here, we compare detector response functions of a coaxial HPGe detector with measurement of 60 Co, 133 Ba, and 137 Cs at varying count rates, and we conduct a parameter study to demonstrate the effect of changing parameters in the DRiFT simulation. The HPGe detector response function shows excellent agreement with measurements of difference sources with varying dead times and count rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Niowave Neutron Source Converter: Lead-Bismuth-Eutectic (LBE) Windowless Target Design and Evaluation

Los Alamos National Laboratory (LANL) is working with Niowave on the design and evaluation of their lead-bismuth-eutectic (LBE) windowless target (i.e., neutron source converter). Niowave plans to use 200 kW electron beam at 40 MeV beam energy to produce neutrons by photonuclear reaction with LBE. Then, the neutrons undergo fission at the surrounding uranium target assembly (UTA) to produce Molybdenum 99 (Mo-99) as a fission product, which eventually decays to Technetium-99 (Tc-99m). Tc-99m is one of important radioisotopes that is used for medical diagnostics. LANL conducted 3D multiphysics analysis for the Niowave neutron converter design and provided design assessment in thermohydraulic aspects. LANL conducted radiation transport calculations using Monte-Carlo N-Particle (MCNP) code with unstructured meshing scheme. The 3D volumetric heating profiles in the LBE and Stainless-Steel (SS) housing were imported into multiphase computational fluid dynamics (CFD) to obtain 3D temperature profiles of LBE and SS through conjugate heat transfer (CHT) analysis. The key findings are: LBE film thickness at the center of the beam is approximately 1.6 cm with a maximum LBE velocity of approximately 1.8 m/s, which is below a 2 m/s limit to avoid erosion issues on supporting structures; Heat deposition in the LBE peaks at ~1 cm depth from the LBE free-surface because of the forward interactions of electron, photon, and neutron with LBE; LBE maximum temperature is ~360 °C, which is below LBE evaporation initiative temperature, ~450 °C; LBE-SS interface temperature is ~350 °C, which is below the safety thermal limit to prevent severe corrosion on SS. The results indicate that Niowave’s neutron converter design satisfies both hydraulic and thermal criteria for safe operation. By virtue of such computational analysis, Niowave can move toward establishing an experimental setup to experimentally test their LBE neutron converter. The following sections describe the detailed work done by LANL.

43 PARTICLE ACCELERATORS↗

Development of MCNP Training Modules for Safeguards Practitioners [Abstract]

The Monte-Carlo N-Particle (MCNP) software developed at LANL is the most widely used neutron transport code in the world. It is an essential tool for a variety of applications including detector development and design, nuclear fuel burnup simulation, criticality safety, and nondestructive assay system optimization. For this reason, it is indispensable within the safeguards and materials control & accountability (MC&A) communities. Multiple MCNP training courses have been created and taught over the last several decades by the MCNP development team at LANL, however there are no existing courses that cover specialized topics considered fundamental to NDA and safeguards models. To fill this gap, the MCNP team and Safeguards Science and Technology group at LANL have co-created a set of training modules customized to meet the specialized needs of the safeguards and MC&A communities. The basic modules cover concepts such as NDA system optimization, He-specific and other capture tallies, and tools for improved theoretical understanding. An advanced module was also created to cover topics including variance reduction for active interrogation simulations, use of the LANL MCNPTools post-processor, PTRAC (particle tracking) and list-mode data simulations, and fuel burnup simulations. The training modules teach to the latest and most state-of-the-art MCNP features and tools released by the development team at LANL and are intended to be taught jointly by the developers and safeguards experts. Ultimately, we hope that creation of these modules will serve to capture and convey the safeguards modeling and MCNP expertise at LANL, and that we will be able to share the modules more broadly with the MC&A and safeguards communities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Forward Modeling of Gamma Reaction History Signatures From Anticipated Deuterium-Tritium Filled MagLIF Implosions on Sandia’s Z-Machine

Nuclear reaction history measurements provide a bang time and burn width of Inertial Confinement Fusion (ICF) implosions and are essential for understanding implosion performance to constrain ICF capsule design. When fusion fuel contains Deuterium (D) and Tritium (T) gas, reaction history is informed by measuring the 16.75 MeV gamma rays generated from the D(T,γ) 5 He reaction. Such DT based reaction history measurements have not been made on the Magnetized Laser Inertial Fusion (MagLIF) platform on Sandia’s Z-Machine due to the lack of Tritium being used. The recent development of ICF implosions with tritiated fuel will open the possibility of measuring the gamma reaction history on the Z-Machine. A forward model of the Gamma Reaction History diagnostic on Z (GRH-Z) has been developed using the MCNP6.3 (Monte-Carlo N-Particle) radiation transport code. The model included the Z-Machine geometry of interest to characterize the impact of neutron induced gamma rays on the DT reaction history measurements. In addition, the impulse response functions of the GRH-Z diagnostic to understand the temporal response of the detector, and the minimum yields required to make a reaction history measurement were calculated. This approach also predicted that with T 2 gas doping of MagLIF implosions a reaction history may be made for high performance shots >8e12-2.4e13 depending on the chosen threshold for the detector, with a maximum signal to background ratio of 25%. It was found that for long duration ICF implosions that additional collimation will be needed to prevent the neutron induced gamma rays from modifying the shape of the measured DT reaction history curve.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗