Search NASA⌕ Search

SEARCH · Search NASA

Results for “Morgana”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

The Effect of Heating on the Degradation of Ground Laboratory and Space Irradiated Teflon(r) FEP

The outer most layer of the multilayer insulation (MLI) blankets on the Hubble Space Telescope (HST) is back surface aluminized Teflon(R) FEP (fluorinated ethylene propylene). As seen by data collected after each of the three servicing missions and as observed during the second servicing mission (SM2), the FEP has become embrittled in the space environment, leading to degradation of the mechanical properties and severe on-orbit cracking of the FEP. During SM2, a sample of aluminized-FEP was retrieved from HST that had cracked and curled, exposing its aluminum backside to space. Because of the difference in optical properties between FEP and aluminum, this insulation piece reached 200 C on-orbit, which is significantly higher than the nominal MLI temperature extreme of 50 C. This piece was more brittle than other retrieved material from the first and third servicing missions (SM1 and SM3A, respectively). Due to this observation and the fact that Teflon thermal shields on the solar array bi-stems were heated on-orbit to 130 C, experiments have been conducted to determine the effect of heating on the degradation of FEP that has been irradiated in a ground laboratory facility or in space on HST. Teflon FEP samples were X-ray irradiated in a high vacuum facility in order to simulate the damage caused by radiation in the space environment. Samples of pristine FEP, X-ray irradiated FEP and FEP retrieved from the HST during SM3A were heat treated from 50 to 200 C at 25 intervals in a high vacuum facility and then tensile tested. In addition, samples were tested in a density gradient column to determine the effect of the radiation and heating on the density of FEP. Results indicate that although heating does not degrade the tensile properties of non-irradiated Teflon, there is a significant dependence of the percent elongation at failure of irradiated Teflon as a function of heating temperature. Irradiated Teflon was found to undergo increasing degradation in the elongation at failure as temperature was increased from room temperature to 200 C. Rate of degradation changes, which were consistent with the glass I transition temperatures for FEP, appeared to be present in both tensile and density data. The results indicate the significance of the on-orbit temperature of Teflon FEP with respect to its degradation in the low Earth orbital space environment.

deGroh, Kim K.↗

Thermal Contributions to the Degradation of Ground Laboratory and Space Irradiated Teflon

The aluminized Teflon fluorinated ethylene propylene outer most layer of the multilayer insulation blankets on the Hubble Space Telescope has become embrittled resulting in severe on-orbit cracking. During the second servicing mission, a piece of aluminized fluorinated ethylene propylene was retrieved that had curled, exposing the back-surface aluminum to space. This extremely embrittled piece reached 200 C on-orbit, 150 C higher than the nominal temperature extreme. Therefore, experiments have been conducted to determine the effect of heating on the degradation of fluorinated ethylene propylene that has been irradiated in a ground laboratory facility or in space on Hubble Space Telescope. Samples of pristine, x-ray irradiated and Hubble Space Telescope retrieved fluorinated ethylene propylene were heat treated from 50 to 200 C at 25 C intervals in a high vacuum facility and tensile tested. Density measurements were also obtained. Results indicate that heating does not embrittle non-irradiated Teflon. However, there is a significant dependence of the embrittlement of irradiated Teflon on heating temperature, with near complete loss of elongation at 100 C and higher. Rate of degradation changes, which were consistent with the glass transition temperature for fluorinated ethylene propylene, were present in the data. The results support chain scission as the primary mechanism of degradation of fluorinated ethylene propylene on Hubble Space Telescope, and indicate the significance of the on-orbit temperature of fluorinated ethylene propylene with respect to its degradation in the space environment.

deGroh, Kim K.↗

Thermal Contributions to the Degradation of Ground-Laboratory- and Space-Irradiated Teflon Investigated

The Hubble Space Telescope (HST) is covered with two primary types of thermal control materials, radiators and multilayer insulation blankets, which passively control temperatures during orbit. Both of these thermal control materials utilize back-surface metalized Teflon FEP (DuPont, fluorinated ethylene propylene) as the exterior (spacefacing) layer because of its excellent optical properties (low solar absorptance and high thermal emittance). The aluminized-FEP (Al-FEP) outermost layer of the multilayer insulation blankets on the HST has become embrittled while in space, resulting in severe on-orbit cracking (see the photographs). During the second servicing mission, an extremely embrittled piece of Al-FEP was retrieved that had curled, exposing the backsurface aluminum to space (see the photograph on the right). Because the aluminum surface has a lower thermal emittance than the FEP, this curled piece reached 200 C during orbit, 150 C higher than the nominal temperature extreme. To better understand the effect of temperature on the rate of degradation, and on the mechanism of degradation, of this insulation material in the low-Earth-orbit environment, researchers at the NASA Glenn Research Center conducted experiments to determine the effect of heating on the degradation of FEP that has been irradiated in a ground laboratory facility or in space on the HST. For this study, Teflon FEP retrieved from the HST during the third servicing mission after 9.7 years of space exposure was provided to Glenn by the NASA Goddard Space Flight Center.

deGroh, Kim K.↗

The Effect of Heating on the Degradation of Ground Laboratory and Space Irradiated Teflon® FEP

The outer most layer of the multilayer insulation (MLI) blankets on the Hubble Space Telescope (HST) is back surface aluminized Teflon® FEP (fluorinated ethylene propylene). As seen by data collected after each of the three servicing missions and as observed during the second servicing mission (SM2), the FEP has become embrittled in the space environment, leading to degradation of the mechanical properties and severe on-orbit cracking of the FEP. During SM2, a sample of aluminized-FEP was retrieved from HST that had cracked and curled, exposing its aluminum backside to space. Because of the difference in optical properties between FEP and aluminum, this insulation piece reached 200 C on-orbit, which is significantly higher than the nominal MLI temperature extreme of 50 C. This piece was more brittle than other retrieved material from the first and third servicing missions (SM1 and SM3A, respectively). Due to this observation and the fact that Teflon thermal shields on the solar array bi-stems were heated on-orbit to 130 C, experiments have been conducted to determine the effect of heating on the degradation of FEP that has been irradiated in a ground laboratory facility or in space on HST. Teflon FEP samples were x-ray irradiated in a high vacuum facility in order to simulate the damage caused by radiation in the space environment. Samples of pristine FEP, x-ray irradiated FEP and FEP retrieved from the HST during SM3A were heat treated from 50 to 200 C at 25intervals in a high vacuum facility and then tensile tested. In addition, samples were tested in a density gradient column to determine the effect of the radiation and heating on the density of FEP. Results indicate that although heating does not degrade the tensile properties of non-irradiated Teflon, there is a significant dependence of the percent elongation at failure of irradiated Teflon as a function of heating temperature. Irradiated Teflon was found to undergo increasing degradation in the elongation at failure as temperature was increased from room temperature to 200 C. Rate of degradation changes, which were consistent with the glass I transition temperatures for FEP, appeared to be present in both tensile and density data. The results indicate the significance of the on-orbit temperature of Teflon FEP with respect to its degradation in the low Earth orbital space environment.

Hubble Space Telescope↗

Microwave Sintering for Lunar Base Construction

Presentation to the Materials Science and Technology Conference 2023 on microwave sintering for the construction of a lunar base. Content includes an overview of NASA's goals, lunar materials, lunar construction, development and testing of the microwave sintered materials, and a summary of the work to date.

Microwave sintering↗