Search NASA⌕ Search

SEARCH · Search NASA

Results for “Motor Starter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

EMP Testing of NAE Magnetic Motor Starters

Sandia National Laboratories (SNL) performed a high-altitude nuclear electromagnetic pulse (HEMP) critical generation station component vulnerability test campaign with a focus on high-frequency, conducted early-time (E1) HEMP for the Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER). This report provides vulnerability test results to investigate component response and/or damage thresholds to reasonable HEMP threat levels that will help to inform site vulnerability assessments, mitigation planning, and modeling calibrations. This work details testing of North American Electric (NAE) magnetic motor starters to determine the effects of conducted HEMP environments. Motor starters are the control elements that provide power to motors throughout a generating plant; a starter going offline would cause loss of power to critical pumps and compressors, which could lead to component damage or unplanned plant outages. Additionally, failed starters would be unable to support plant startup. Six industrial motor starters were tested: two 2 horsepower (HP) starters with breaker disconnects and typical protection equipment, two 20 HP starters with breaker disconnects, and two 20 HP starters with fused disconnects. Each starter was placed in a circuit with a generator and inductive motor matching the starter rating. The conducted EMP insult was injected on the power cables passing through the motor starter, with separate tests for the generator and motor sides of the starter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stop and Restart Effects on Modern Vehicle Starting System Components

Many drivers of personal and commercial vehicles believe that turning the vehicle off and on frequently instead of idling will cause premature wear of the starter system (starter motor and starter battery). As a result, they are concerned that the replacement cost of the starter motor and/or battery due to increased manual engine cycling would be more than the cumulative cost of the fuel saved by not idling unnecessarily. A number of variables play a role in addressing this complex concern, including the number of starting cycles per day, the time between starting cycles, the intended design life of the starting system, the amount of fuel used to restart an engine, and the cumulative cost of the saved fuel. Qualitative and quantitative information from a variety of sources was used to develop a life-cycle economic model to evaluate the cost and quantify the realistic factors that are related to the permissible frequency of starter motor cycles for the average vehicle to economically minimize engine idle time. Annual cost savings can be calculated depending on shutdown duration and the number of shutdown cycles per day. Analysis shows that cost savings are realized by eliminating idling exceeding one minute by shutting down the engine and restarting it. For a typical motorist, the damage to starting system components resulting from additional daily start cycles will be negligible. Overall, it was found that starter life is mostly dependent on the total number of start cycles, while battery life is more dependent on ensuring a full charge between start events.

42 ENGINEERING↗

Modernization of PLC-Based Control Systems at SNS

When the SNS site was built around 20 years ago, the Conventional Facilities (CF) control systems were de-signed using 2 communication protocols to allow pro-grammable logic controllers (PLCs) to interface with motors, variable frequency drives (VFDs), and remote input and output (I/O) devices. The protocol chosen to control motors and VFDs is DeviceNet, a CANbus-based protocol developed by Allen-Bradley, a subsidiary of Rockwell Automation. The protocol chosen to communi-cate with remote I/O is ControlNet, another protocol developed by Allen-Bradley. Both of these protocols are obsolete and present reliability and maintainability is-sues, particularly DeviceNet. As the Control Systems Section at SNS is working to modernize control systems throughout the machine, a major goal for PLC-based systems is to remove the obsolete communication proto-cols in favor of standard, ubiquitous Ethernet. To this end, any new VFDs installed use Ethernet communica-tion. Many VFDs are currently being replaced in the Central Utilities Building (CUB) and the Central Exhaust Facility (CEF) and are being removed from DeviceNet in favor of Ethernet communication. Planning is underway to retrofit Eaton Intelligent Technology motor control centers (MCCs) in the Target Building to remove particu-larly troublesome DeviceNet adaptors and replace them with Ethernet adaptors for each motor starter. The Con-trolNet network in the CUB has been demolished, with I/O drops integrated into a local Ethernet network, im-proving sustainability and maintainability.

Beaushaw, Isaiah [ORNL]↗

Motor Control Center Design

This poster contains information dealing with the design of a Motor Control Center that drives an exhaust, heating and lighting system inside a deep well house.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wireless Sensor Network for Advanced Energy Management Solutions

Eaton has developed an advanced energy management solution that has been deployed to several Industries of the Future (IoF) sites. This demonstrated energy savings and reduced unscheduled downtime through an improved means for performing predictive diagnostics and energy efficiency estimation. Eaton has developed a suite of online, continuous, and inferential algorithms that utilize motor current signature analysis (MCSA) and motor power signature analysis (MPSA) techniques to detect and predict the health condition and energy usage condition of motors and their connect loads. Eaton has also developed a hardware and software platform that provided a means to develop and test these advanced algorithms in the field. Results from lab validation and field trials have demonstrated that the developed advanced algorithms are able to detect motor and load inefficiency and performance degradation. Eaton investigated the performance of Wireless Sensor Networks (WSN) within various industrial facilities to understand concerns about topology and environmental conditions that have precluded broad adoption by the industry to date. A Wireless Link Assessment System (WLAS), was used to validate wireless performance under a variety of conditions. Results demonstrated that wireless networks can provide adequate performance in most facilities when properly specified and deployed. Customers from various IoF expressed interest in applying wireless more broadly for selected applications, but continue to prefer utilizing existing, wired field bus networks for most sensor based applications that will tie into their existing Computerized Motor Maintenance Systems (CMMS). As a result, wireless technology was de-emphasized within the project, and a greater focus placed on energy efficiency/predictive diagnostics. Commercially available wireless networks were only utilized in field test sites to facilitate collection of motor wellness information, and no wireless sensor network products were developed under this project. As an outgrowth of this program, Eaton developed a patented energy-optimizing drive control technology that is complementary to a traditional variable frequency drives (VFD) to enable significant energy savings for motors with variable torque applications, such as fans, pumps, and compressors. This technology provides an estimated energy saving of 2%-10% depending on the loading condition, in addition to the savings obtained from a traditional VFD. The combination of a VFD with the enhanced energy-optimizing controls will provide significant energy savings (10% to 70% depending on the load and duty cycle) for motors that are presently connected with across the line starters. It will also provide a more favorable return on investment (ROI), thus encouraging industries to adopt VFDs for more motors within their facilities. The patented technology is based on nonintrusive algorithms that estimate the instantaneous operating efficiency and motor speed and provide active energy-optimizing control of a motor, using only existing voltage and current sensors. This technology is currently being commercialized by Eaton’s Industrial Controls Division in their next generation motor control products. Due to the common nonintrusive and inferential nature of various algorithms, this same product can also include motor and equipment condition monitoring features, providing the facility owner additional information to improve process uptime and the associated energy savings. Calculations estimated potential energy savings of 261,397GWh/Yr ($15.7B/yr), through retrofitting energy-optimizing VFDs into existing facilities, and incorporating the solution into building equipment sold by original equipment manufacturers (OEMs) and installed by mechanical and electrical contractors. Utilizing MCSA and MPSA for predictive maintenance (PM) of motors and connected equipment reduces process downtime cost and the cost of wasted energy associated with shutting down and restarting the processes. Estimated savings vary depending on the industry segment and equipment criticality per facility/process. Average downtime for an industrial facility is 4-12 hours with a cost/hr of $7500/hr, with large, critical processes reaching $50-100k/hr. Specific downtime costs are not included in this report because of customer confidentiality, but projected savings across the Industries of the Future (IoF) are still expected to be comparable to the original program estimates. Two generations of customer field deployments and evaluation have been completed during the course of this project. Results from these customer sites have been used for identifying the scope and improving the developed energy and wellness algorithms. The field deployments have confirmed that the hardware for sensing and sampling motor currents and voltages are reliable and able to provide an adequate signal-to-noise ratio from the electrical noise present on the motor signals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

INL POSTER 2025- KRYSTAL FOSTER

The Advanced Test Reactor (ATR) employs the N-16 system to measure reactor power by detecting beta particles emitted from nitrogen-16 isotopes. During startup, the N-16 pumps cause rapid oscillations in the discharge piping due to pressure transients, which cease when the valve supplying N-16 flow to the reactor is opened. To address this, a soft-starter is proposed to gradually increase the motor voltage, reducing mechanical stress and preventing pressure surges. This solution enhances system stability, lowers maintenance costs, extends equipment lifespan, and is more cost-effective than Variable Frequency Drives (VFDs), making it ideal for the infrequently activated N-16 pumps.

42 - ENGINEERING↗

Quantum tunneling switch in a planar four-well system

We investigate the tunneling dynamics of a single atom in a planar four-well potential driven by a high-frequency ac field. The quasienergy spectrum exhibits anticrossing and crossing, which are related to selective coherent destruction of tunneling (CDT) with several selectable directions. By using the CDTs of different directions, the switchlike effect is shown for the six tunneling pathways among the four wells. Applying the present results, we suggest a scheme for designing a single-atom quantum motor with the driving field as a quantum starter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design of Power Hardware-in-the-Loop Simulations for Integrated Starter–Generator Systems

The integrated starter-generator system (ISGS) is a combination of starter and generator for independent power systems in transportation. It replaces both a conventional starter and generator with a single set of highly integrated devices. A power hardware in the loop simulation that is flexible and can include the hardware under test is used to test the ISGS under representative field conditions. This paper utilizes the special structure of the ISGS and proposes an ISGS emulator (ISGSE) to develop and test the converter. The proposed ISGSE can be used to test a variety of motor drives or rectifiers including dynamic capabilities without necessitating a connection to a large motor load. To emulate the ISGS, the structure and operation principle in different modes are introduced in detail. Also, the issue of stability and accuracy is discussed in this paper. Furthermore, detailed simulation and experimental comparisons are carried out between the ISGS and the ISGSE, which validates the proposed ISGSE as an effective tool for designing and testing new motor drives.

42 ENGINEERING↗

Safer Vehicles for People and the Planet: Letter to the Editor

Letter to the Editors from Leonard Evans, Bloomfield Hills, MI: Single-vehicle crashes, which account for half of occupant fatalities, are not mentioned in 'Safer Vehicles for People and the Planet', by Thomas P. Wenzel and Marc Ross (March-April). Simple physics shows that in such crashes risk declines as vehicle mass increases. The authors write 'driving imported luxury cars carries extremely low risk, for reasons that are not obvious'. The reasons are obvious--the cars are purchased by low-risk drivers. If they swapped vehicles with drivers of sports cars (which have high risk), the risks would stick with the drivers, not the vehicles. The article reflects the American belief that death on our roads can be substantially reduced by making vehicles in which it is safer to crash. From 1979 through 2002, Great Britain, Canada and Australia reduced fatalities by an average of 49 percent, compared with 16 percent in the U.S. Accumulating the differences over this time shows that by merely matching the safety performance of these other countries, about 200,000 fewer Americans would have died. These trends continue. In 2006 the U.S. recorded 42,642 traffic deaths, a modest 22 percent decline from our all-time high. Sweden recorded 445, a reduction of 66 percent from their all-time high. The obsessive focus on vehicles rather than on countermeasures that scientific research shows substantially reduce risk is at the core of our dramatic safety failure. The only way to substantially reduce deaths is to reduce the risk of crashing, not to make it safer to crash. The response from Drs. Wenzel and Ross: Of course Dr. Evans is correct in stating that driver behavior influences crash risk. In our article we made clear that our estimates of risk include how well a vehicle/driver combination avoids a crash, as well as how crash-worthy a vehicle (and robust a driver) is once a crash occurs. We also analyzed two variables that can account for driver behavior: the fraction of all driver fatalities that are young men, and a 'bad driver' rating that combines information about the current crash (drug or alcohol involvement, driving without a license, or reckless driving) as well as the operator's driving record for the previous three years. For example, the high risks of sports cars, and the low risks of minivans, are clearly influenced by who drives these types of vehicles (36 percent young males and 0.77 bad driver rating for sports cars, vs. 4 percent and 0.21 for minivans; the average values for all types of cars are 20 percent and 0.50). On the other hand, we were surprised to find that the imported luxury cars, with the lowest risks, have only average drivers (21 percent young males, 0.57 bad driver rating). That is the basis for our conclusion that the design of imported luxury vehicles, or at least specific safety features on them, overcome risky behavior taken by their drivers. The safety of vehicles has greatly improved over the years. In our studies we have found several examples of models that greatly reduced their risks over time; for example, the Ford Focus has a much better risk to its drivers (118) than the Ford Escort it replaced (148). Our data indicate that more young males drive the Focus (21 percent) than the Escort (15 percent), and that Focus drivers are perhaps slightly more risky (0.50 vs. 0.44 bad driver rating). Clearly vehicle design does not play as small a role in vehicle safety as Dr. Evans suggests. Dr. Evans asserts that we ignore single-vehicle crashes and that simple physics dictates that vehicle mass provides safety in single-vehicle crashes. By itself, additional vehicle mass does provide some protection from rapid deceleration in crashes with a movable object, particularly for an unbelted occupant. However, when it comes to vehicle safety, our research by vehicle model indicates that there is essentially no relationship between car mass and risk, even in frontal crashes. In his own papers, Dr. Evans appears to admit that it is not clear whether mass, or size (specifically crush space) is inherent to vehicle safety. Additional research indicates that it is not size per se that protects in two-vehicle crashes, but how well the stiff structures on the vehicles are aligned. The auto manufacturing industry has voluntarily made design changes to their pickup trucks to increase the likelihood that truck and car bumpers will interact in a frontal crash, reducing the aggressivity of pickup trucks in recent years. Regarding the differences in experiences between the U.S. and other countries, it is important to keep in mind that the U.S. vehicle fleet is fairly unique; about half of U.S. vehicles are light duty trucks (pickups, SUVs and minivans), which many studies have shown are dangerous to other road users.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗