Search NASA⌕ Search

SEARCH · Search NASA

Results for “Muscle Fatigue”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Muscle Deoxygenation Causes Muscle Fatigue

Muscle fatigue is a common musculoskeletal disorder in the work place, and may be a harbinger for more disabling cumulative trauma disorders. Although the cause of fatigue is multifactorial, reduced blood flow and muscle oxygenation may be the primary factor in causing muscle fatigue during low intensity muscle exertion. Muscle fatigue is defined as a reduction in muscle force production, and also occurs among astronauts who are subjected to postural constraints while performing lengthy, repetitive tasks. The objectives of this research are to: 1) develop an objective tool to study the role of decreased muscle oxygenation on muscle force production, and 2) to evaluate muscle fatigue during prolonged glovebox work.

Murthy, G.↗

Development and Applications of a Self-Contained, Non-Invasive EVA Joint Angle and Muscle Fatigue Sensor System

The University of Maryland Space Systems Laboratory, as a participant in NASA's INSTEP program, is developing a non-invasive, self-contained sensor system which can provide quantitative measurements of joint angles and muscle fatigue in the hand and forearm. The goal of this project is to develop a system with which hand/forearm motion and fatigue metrics can be determined in various terrestrial and zero-G work environments. A preliminary study of the prototype sensor systems and data reduction techniques for the fatigue measurement system are presented. The sensor systems evaluated include fiberoptics, used to measure joint angle, surface electrodes, which measure the electrical signals created in muscle as it contracts; microphones, which measure the noise made by contracting muscle; and accelerometers, which measure the lateral muscle acceleration during contraction. The prototype sensor systems were used to monitor joint motion of the metacarpophalangeal joint and muscle fatigue in flexor digitorum superficialis and flexor carpi ulnaris in subjects performing gripping tasks. Subjects were asked to sustain a 60-second constant-contraction (isometric) exercise and subsequently to perform a repetitive handgripping task to failure. Comparison of the electrical and mechanical signals of the muscles during the different tasks will be used to evaluate the applicability of muscle signal measurement techniques developed for isometric contraction tasks to fatigue prediction in quasi-dynamic exercises. Potential data reduction schemes are presented.

Ranniger, C. U.↗

Ischemia causes muscle fatigue

The purpose of this investigation was to determine whether ischemia, which reduces oxygenation in the extensor carpi radialis (ECR) muscle, causes a reduction in muscle force production. In eight subjects, muscle oxygenation (TO2) of the right ECR was measured noninvasively and continuously using near infrared spectroscopy (NIRS) while muscle twitch force was elicited by transcutaneous electrical stimulation (1 Hz, 0.1 ms). Baseline measurements of blood volume, muscle oxygenation and twitch force were recorded continuously, then a tourniquet on the upper arm was inflated to one of five different pressure levels: 20, 40, 60 mm Hg (randomized order) and diastolic (69 +/- 9.8 mm Hg) and systolic (106 +/- 12.8 mm Hg) blood pressures. Each pressure level was maintained for 3-5 min, and was followed by a recovery period sufficient to allow measurements to return to baseline. For each respective tourniquet pressure level, mean TO2 decreased from resting baseline (100% TO2) to 99 +/- 1.2% (SEM), 96 +/- 1.9%, 93 +/- 2.8%, 90 +/- 2.5%, and 86 +/- 2.7%, and mean twitch force decreased from resting baseline (100% force) to 99 +/- 0.7% (SEM), 96 +/- 2.7%, 93 +/- 3.1%, 88 +/- 3.2%, and 86 +/- 2.6%. Muscle oxygenation and twitch force at 60 mm Hg tourniquet compression and above were significantly lower (P < 0.05) than baseline value. Reduced twitch force was correlated in a dose-dependent manner with reduced muscle oxygenation (r = 0.78, P < 0.001). Although the correlation does not prove causation, the results indicate that ischemia leading to a 7% or greater reduction in muscle oxygenation causes decreased muscle force production in the forearm extensor muscle. Thus, ischemia associated with a modest decline in TO2 causes muscle fatigue.

Non-NASA Center↗

Muscle fatigue in frog semitendinosus: role of intracellular pH

The purpose of this study was to utilize glass microelectrodes to characterize the intracellular pH (pHi) before and during recovery from fatigue in the frog semitendinosus (ST) muscle. A second objective was to evaluate the relationship between pHi and contractile function. The frog ST muscle (22 degrees C) was fatigued by direct electrical stimulation with 100-ms 150-Hz trains at 1/s for 5 min. Peak tetanic force (Po) was reduced to 8.5% of initial force and recovered in a biphasic manner, returning to the resting value by 40 min. Resting pHi was 7.00 +/- 0.02 (n = 37) and declined with fatigue to an average value of 6.42 at 3 min of recovery. During recovery pHi significantly increased and by 25 min had returned to the prefatigue value. The pHi recovery was highly correlated to the slow phase of Po recovery (r = 0.98, P less than 0.001). The mean resting membrane potential was -78 +/- 1.0 mV (n = 42) and at 3 min of recovery was depolarized to -67 +/- 4 mV. Both the peak rate of twitch force development (+dP/dt) (r = 0.99, P less than 0.001) and decline (-dP/dt) (r = 0.94, P less than 0.014) were highly correlated to pHi during the slow phase of recovery. Contraction time (CT) and one-half relaxation time (1/2RT) increased significantly and recovered exponentially. The recovery of CT and 1/2RT were both significantly correlated to pHi (r = -0.93, P less than 0.001 and r = -0.86, P less than 0.001 for CT and 1/2RT, respectively).(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Discipline Musculoskeletal↗

Evaluation of localized muscle fatigue using power spectral density analysis of the electromyogram

Surface electromyograms (EMGs) taken from three upper torso muscles during a push-pull task were analyzed by a power spectral density technique to determine the operational feasibility of the technique for identifying changes in the EMGs resulting from muscular fatigue. The EMGs were taken from four subjects under two conditions (1) in shirtsleeves and (2) in a pressurized space suit. This study confirmed that frequency analysis of dynamic muscle activity is capable of providing reliable data for many industrial applications where fatigue may be of practical interest. The results showed significant effects of the pressurized space suit on the pattern of shirtsleeve fatigue responses of the muscles. The data also revealed (1) reliable differences between muscles in fatigue-induced responses to various locations in the reach envelope at which the subjects were required to perform the push-pull exercise and (2) the differential sensitivity of muscles to the various reach positions in terms of fatigue-related shifts in EMG power.

Lafevers, E. V.↗

Muscle fatigue in frog semitendinosus: alterations in contractile function

The purpose of this study was to characterize the contractile properties of the frog semitendinosus (ST) muscle before and during recovery from fatigue, to relate the observed functional changes to alterations in specific steps in the crossbridge model of muscle contraction, and to determine how fatigue affects the force-frequency relationship. The frog ST (22 degrees C) was fatigued by direct electrical stimulation with 100-ms 150-Hz trains at 1/s for 5 min. The fatigue protocol reduced peak twitch (Pt) and tetanic (Po) force to 32 and 8.5% of initial force, respectively. The decline in Pt was less than Po, in part due to a prolongation in the isometric contraction time (CT), which increased to 300% of the initial value. The isometric twitch duration was greatly prolonged as reflected by the lengthened CT and the 800% increase in the one-half relaxation time (1/2RT). Both Pt and Po showed a biphasic recovery, a rapid initial phase (2 min) followed by a slower (40 min) return to the prefatigue force. CT and 1/2RT also recovered in two phases, returning to 160 and 265% of control in the first 5 min. CT returned to the prefatigue value between 35 and 40 min, whereas even at 60 min 1/2RT was 133% of control. The maximal velocity of shortening, determined by the slack test, was significantly reduced [from 6.7 +/- 0.5 to 2.5 +/- 0.4 optimal muscle length/s] at fatigue. The force-frequency relationship was shifted to the left, so that optimal frequency for generating Po was reduced.(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Discipline Musculoskeletal↗

Operator performance and localized muscle fatigue in a simulated space vehicle control task

Fourier transforms in a special purpose computer were utilized to obtain power spectral density functions from electromyograms of the biceps brachii, triceps brachii, brachioradialis, flexor carpi ulnaris, brachialis, and pronator teres in eight subjects performing isometric tracking tasks in two directions utilizing a prototype spacecraft rotational hand controller. Analysis of these spectra in general purpose computers aided in defining muscles involved in performing the task, and yielded a derived measure potentially useful in predicting task termination. The triceps was the only muscle to show significant differences in all possible tests for simple effects in both tasks and, overall, was the most consistently involved of the six muscles. The total power monitored for triceps, biceps, and brachialis dropped to minimal levels across all subjects earlier than for other muscles. However, smaller variances existed for the biceps, brachioradialis, brachialis, and flexor carpi ulnaris muscles and could provide longer predictive times due to smaller standard deviations for a greater population range.

Lewis, J. L., Jr.↗

Fatigue mechanisms in patients with cancer: effects of tumor necrosis factor and exercise on skeletal muscle

Fatigue is a common adverse effect of cancer and its therapy. However, the specific mechanisms underlying cancer fatigue are unclear. One physiologic mechanism may involve changes in skeletal muscle protein stores or metabolite concentration. A reduction in skeletal muscle protein stores may result from endogenous tumor necrosis factor (TNF) or from TNF administered as antineoplastic therapy. This muscle wasting would require patients to exert an unusually high amount of effort to generate adequate contractile force during exercise performance or during extended periods of sitting or standing. This additional effort could result in the onset of fatigue. Additionally, cancer fatigue may develop or become exacerbated during exercise as a consequence of changes in the concentration of skeletal muscle metabolites. These biochemical alterations may interfere with force that is produced by the muscle contractile proteins. These physiologic changes may play a role in the decision to include exercise in the rehabilitation plans of patients with cancer. They also may affect ideas about fatigue.

Review, Tutorial↗

In Vivo Noninvasive Analysis of Human Forearm Muscle Function and Fatigue: Applications to EVA Operations and Training Maneuvers

Forearm muscle fatigue is one of the major limiting factors affecting endurance during performance of deep-space extravehicular activity (EVA) by crew members. Magnetic resonance (MR) provides in vivo noninvasive analysis of tissue level metabolism and fluid exchange dynamics in exercised forearm muscles through the monitoring of proton magnetic resonance imaging (MRI) and phosphorus magnetic resonance spectroscopy (P-31-MRS) parameter variations. Using a space glove box and EVA simulation protocols, we conducted a preliminary MRS/MRI study in a small group of human test subjects during submaximal exercise and recovery and following exhaustive exercise. In assessing simulated EVA-related muscle fatigue and function, this pilot study revealed substantial changes in the MR image longitudinal relaxation times (T2) as an indicator of specific muscle activation and proton flux as well as changes in spectral phosphocreatine-to-phosphate (PCr/Pi) levels as a function of tissue bioenergetic potential.

Fotedar, L. K.↗

An overview of the issues: physiological effects of bed rest and restricted physical activity

Reduction of exercise capacity with confinement to bed rest is well recognized. Underlying physiological mechanisms include dramatic reductions in maximal stroke volume, cardiac output, and oxygen uptake. However, bed rest by itself does not appear to contribute to cardiac dysfunction. Increased muscle fatigue is associated with reduced muscle blood flow, red cell volume, capillarization and oxidative enzymes. Loss of muscle mass and bone density may be reflected by reduced muscle strength and higher risk for injury to bones and joints. The resultant deconditioning caused by bed rest can be independent of the primary disease and physically debilitating in patients who attempt to reambulate to normal active living and working. A challenge to clinicians and health care specialists has been the identification of appropriate and effective methods to restore physical capacity of patients during or after restricted physical activity associated with prolonged bed rest. The examination of physiological responses to bed rest deconditioning and exercise training in healthy subjects has provided significant information to develop effective rehabilitation treatments. The successful application of acute exercise to enhance orthostatic stability, daily endurance exercise to maintain aerobic capacity, or specific resistance exercises to maintain musculoskeletal integrity rather than the use of surgical, pharmacological, and other medical treatments for clinical conditions has been enhanced by investigation and understanding of underlying mechanisms that distinguish physical deconditioning from the disease. This symposium presents an overview of cardiovascular and musculoskeletal deconditioning associated with reduced physical work capacity following prolonged bed rest and exercise training regimens that have proven successful in ameliorating or reversing these adverse effects.

NASA Program Space Physiology and Countermeasures↗

Coexistence of twitch potentiation and tetanic force decline in rat hindlimb muscle

The effect of whole-muscle fatigue on the isometric twitch was investigated in various hindlimb muscles of anesthetized rats, using an experimental protocol designed to assess the levels of fatigability in motor units. The results of EMG and force measurements revealed the existence of a linear relationship between fatigability and the magnitude of the twitch force following the fatigue test in both soleus and extensor digitorum longus muscles.

Rankin, Lucinda L.↗

EMGAN: A computer program for time and frequency domain reduction of electromyographic data

An experiment in electromyography utilizing surface electrode techniques was developed for the Apollo-Soyuz test project. This report describes the computer program, EMGAN, which was written to provide first order data reduction for the experiment. EMG signals are produced by the membrane depolarization of muscle fibers during a muscle contraction. Surface electrodes detect a spatially summated signal from a large number of muscle fibers commonly called an interference pattern. An interference pattern is usually so complex that analysis through signal morphology is extremely difficult if not impossible. It has become common to process EMG interference patterns in the frequency domain. Muscle fatigue and certain myopathic conditions are recognized through changes in muscle frequency spectra.

Hursta, W. N.↗

Forearm muscle oxygenation decreases with low levels of voluntary contraction

The purpose of our investigation was to determine if the near infrared spectroscopy technique was sensitive to changes in tissue oxygenation at low levels of isometric contraction in the extensor carpi radialis brevis muscle. Nine subjects were seated with the right arm abducted to 45 degrees, elbow flexed to 85 degrees, forearm pronated 45 degrees, and wrist and forearm supported on an armrest throughout the protocol. Altered tissue oxygenation was measured noninvasively with near infrared spectroscopy. The near infrared spectroscopy probe was placed over the extensor carpi radialis brevis of the subject's right forearm and secured with an elastic wrap. After 1 minute of baseline measurements taken with the muscle relaxed, four different loads were applied just proximal to the metacarpophalangeal joint such that the subjects isometrically contracted the extensor carpi radialis brevis at 5, 10, 15, and 50% of the maximum voluntary contraction for 1 minute each. A 3-minute recovery period followed each level of contraction. At the end of the protocol, with the probe still in place, a value for ischemic tissue oxygenation was obtained for each subject. This value was considered the physiological zero and hence 0% tissue oxygenation. Mean tissue oxygenation (+/-SE) decreased from resting baseline (100% tissue oxygenation) to 89 +/- 4, 81 +/- 8, 78 +/- 8, and 47 +/- 8% at 5, 10, 15, and 50% of the maximum voluntary contraction, respectively. Tissue oxygenation levels at 10, 15, and 50% of the maximum voluntary contraction were significantly lower (p < 0.05) than the baseline value. Our results indicate that tissue oxygenation significantly decreases during brief, low levels of static muscle contraction and that near infrared spectroscopy is a sensitive technique for detecting deoxygenation noninvasively at low levels of forearm muscle contraction. Our findings have important implications in occupational medicine because oxygen depletion induced by low levels of muscle contraction may be directly linked to muscle fatigue.

NASA Center ARC↗

Alterations in Skeletal Muscle With Disuse Atrophy: The Effects of Countermeasures

The specific aims of this project concerned three general areas: (1) studies on the contractile function of single skinned fibers designed to determine the time course and cellular basis of the Hindlimb Suspension (HS) induced increase in fiber Vo (maximal shortening velocity), and the decrease in peak tension (Po); (2) studies designed to understand the effect of HS on single fiber substrate utilization during contractile activity, and how if at all such changes contribute to the increased muscle fatigue associated with HS; and (3) studies evaluating the effectiveness of standing and ladder climbing as countermeasures to the deleterious effects of HS. We have constructed all of the necessary equipment, and are currently conducting preliminary studies on T-tubular charge movement. A list of publications from this contract is included at the end of this report. The three objectives are (1) Functional Studies on the Single Skinned Fiber; (2) Fiber Substrate Utilization and Muscle Fatugue with Contracting Activity and (3) Exercise Countermeasures.

Fitts, Robert H.↗

Oxygen uptake kinetics of constant-load work - Upright vs. supine exercise

Supine and upright positions were used in a comparitive study of the effects of constant load exercise on oxygen uptake (VO2), O2 deficit, steady-state VO2 and VO2 following recovery from constant load work. Ten male subjects (36-40 yr.) performed one submaximal exercise test in the supine and one test in the upright position consisting of 5 min rest and 5 min cycle ergometer exercise at 700 kg/min followed by ten minutes of recovery. It is found that the significant difference in VO2 kinetics during exercise in the upright compared to supine position resulted from changes in oxygen transport and utilization mechanisms rather than changes in mechanical efficiency. To the extent that data measured in the supine position can be used to estimate physiological responses to zero gravity, it is suggested that limitation of systemic O2 consumption may be the result of slow rates of oxygen uptake during transient periods of muscular work. Significant reductions in the rate of steady-state VO2 attainment at submaximal work intensities may produce an onset of muscle fatigue and exhaustion.

Convertino, V. A.↗

Ergonomic Chairs

Findings published in the NASA Anthropometric Source Book by Johnson Space Center helped BodyBilt, Inc. to fashion controlled comfort chairs that lessen the harmful effects of gravity on seated workers. Crew members living aboard NASA's Skylab noted that in space the human posture differs from the normal posture caused by the tug of one gravity. There has been an alarming increase in back pain and muscle fatigue in workers, along with a dramatic escalation in repetitive stress injuries. BodyBilt's ergonomically-correct line of office chairs are targeted for the average worker that sits for prolonged periods, be it in the classroom or boardroom. Their roster of national clients lists such organizations as IBM, Microsoft, Texas Instruments, Hewlett-Packard, Eastman-Kodak, Boeing, Motorola, and Walt Disney Studios.

Source record↗

The Potential of Wearable Sensor Technology for EVA Glove Ergonomic Evaluation

Injuries to the hands are common among astronauts who train for extravehicular activity (EVA). Many of these injuries refer to the gloves worn during EVA as the root cause. While pressurized, the bladder and outer material of these gloves restrict movement and create pressure points while performing tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally a more severe injury, onycholysis (fingernail delamination). The most common injury causes are glove contact (pressure point/rubbing), ill-fitting gloves, and/or performing EVA tasks in pressurized gloves. A brief review of the Lifetime Surveillance of Astronaut Health's injury database reveals over 57% of the total injuries to the upper extremities during EVA training occurred either to the metacarpophalangeal (MCP) joint, fingernail, or the fingertip. Twenty-five of these injuries resulted in a diagnosis of onycholysis.

Reid, Christopher R.↗

The Potential of Wearable Sensor Technology for EVA Glove Ergonomic Evaluation

Injuries to the hands are common among astronauts who train for extravehicular activity (EVA). Many of these injuries refer to the gloves worn during EVA as the root cause. While pressurized, the bladder and outer material of these gloves restrict movement and create pressure points while performing tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally a more severe injury, onycholysis (fingernail delamination). The most common injury causes are glove contact (pressure point/rubbing), ill-fitting gloves, and/or performing EVA tasks in pressurized gloves. A brief review of the Lifetime Surveillance of Astronaut Health's injury database reveals over 57% of the total injuries to the upper extremities during EVA training occurred either to the metacarpophalangeal (MCP) joint, fingernail, or the fingertip. Twenty-five of these injuries resulted in a diagnosis of onycholysis

Reid, Christopher R.↗