Search NASA⌕ Search

SEARCH · Search NASA

Results for “Muscular Atrophy/etiology/prevention & control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Urinary excretion of cortisol from rhesus monkeys (Macaca mulatta) habituated to restraint

Use of monkeys in research has often required that they be restrained in a chair. However, chair restraint can elicit an initial neuroendocrine stress response. Also, inactivity associated with restraint can induce muscular atrophy. We proposed that prior habituation of monkeys to chair restraint would attenuate these neuroendocrine responses without causing substantial muscle wasting. Four rhesus monkeys (Macaca mulatta) were trained and habituated to a restraint chair specifically designed for spaceflight. During the study, monkeys were placed in metabolic cages for 7 days (prerestraint, Phase I), placed in a chair restraint for 18 days (Phase II), and then returned to their metabolic cages for 5 days (postrestraint, Phase III). Urine was collected between 0700-1100 daily, and measurements of cortisol, creatinine, and electrolyte concentrations were adjusted for hourly excretion rates. Body weights of the monkeys did not change between start of the prerestraint and postrestraint phases (10.3 +/- 0.8 vs. 10.3 +/- 0.9 kg, respectively). During the 3 phases, mean excretion rate of cortisol did not change (24.1 +/- 10.3, 26.7 +/- 7.7, and 19.3 +/- 5.8 microg/h, respectively). Mean excretion rate of creatinine (37.3 +/- 7.5, 37.5 +/- 12.2, and 36.9 +/- 17.1 mg/h, respectively), Na+ (3.3 +/- 1.2, 3.2 +/- 1.2, 2.2 +/- 1.8 mmol/h, respectively), and K+ (5.3 +/- 1.8, 5.4 +/- 1.6, and 4.3 +/- 2.8 mmol/h, respectively) were also not altered. Lack of an increase in excreted urinary cortisol suggested that prior habituation to chair restraint attenuated neuroendocrine responses reported previously. Also, the chair restraint method used appeared to allow adequate activity, because the monkeys did not have indices of muscle wasting.

NASA Center ARC↗

Locomotion in simulated microgravity: gravity replacement loads

BACKGROUND: When an astronaut walks or runs on a treadmill in microgravity, a subject load device (SLD) is used to return him or her back to the treadmill belt. The gravity replacement load (GRL) in the SLD is transferred, via a harness, to the pelvis and/or the shoulders. This research compared comfort and ground reaction forces during treadmill running in a microgravity locomotion simulator at GRLs of 60%, 80%, and 100% of body weight (BW). Two harness designs (shoulder springs only (SSO) and waist and shoulder springs (WSS)) were used. HYPOTHESES: 1) The 100% BW gravity replacement load conditions would be comfortably tolerated and would result in larger ground reaction forces and loading rates than the lower load conditions, and 2) the WSS harness would be more comfortable than the SSO harness. METHODS: Using the Penn State Zero Gravity Locomotion Simulator (ZLS), 8 subjects ran at 2.0 m x s(-1) (4.5 mph) for 3 min at each GRL setting in each harness. Subjective ratings of harness comfort, ground reaction forces, and GRL data were collected during the final minute of exercise. RESULTS: The 100% BW loading conditions were comfortably tolerated (2.3 on a scale of 0-10), although discomfort increased as the GRL increased. There were no overall differences in perceived comfort between the two harnesses. The loading rates (27.1, 33.8, 39.1 BW x s(-1)) and the magnitudes of the first (1.0, 1.4, 1.6 BW) and second (1.3, 1.7, 1.9 BW) peaks of the ground reaction force increased with increasing levels (60, 80, 100% BW respectively) of GRL. CONCLUSIONS: Subjects were able to tolerate a GRL of 100% BW well. The magnitude of the ground reaction force peaks and the loading rate is directly related to the magnitude of the GRL.

NASA Discipline Musculoskeletal↗

The use of in-flight foot pressure as a countermeasure to neuromuscular degradation

The purpose of this study was to determine whether applying foot pressure to unrestrained subjects during space flight could enhance the neuromuscular activation associated with rapid arm movements. Four men performed unilateral arm raises while wearing--or not wearing--specially designed boots during a 81- or 115-day space flight. Arm acceleration and surface EMG were obtained from selected lower limb and trunk muscles. Pearson r coefficients were used to evaluate similarity in phasic patterns between the two in-flight conditions. In-flight data also were magnitude normalized to the mean voltage value of the muscle activation waveforms obtained during the no-foot-pressure condition to facilitate comparison of activation amplitude between the two in-flight conditions. Foot pressure enhanced neuromuscular activation and somewhat modified the phasic features of the neuromuscular activation during the arm raises.

Mir Project↗