Search NASA⌕ Search

SEARCH · Search NASA

Results for “Music”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Atomic tunes: The intersection of Lab science and popular music from 1945-1962 How American music was influenced by nuclear science

The American public realized the magnitude at which the atom’s power could be harnessed following the detonation of Little Boy and Fat Man in August 1945. World War II ended weeks later, but the Atomic Age had just begun. Society contextualized nuclear science into pop culture as a way of processing the era’s immense technological progress. Music, among other media, became a speculative arena for expressing the awe and angst evoked by splitting the atom.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimality of Gradient-MUSIC for Spectral Estimation

We introduce the Gradient-MUSIC algorithm for estimating the unknown frequencies and amplitudes of a nonharmonic signal from noisy time samples. While the classical MUSIC algorithm performs a computationally expensive search over a fine grid, Gradient-MUSIC is significantly more efficient and eliminates the need for discretization over a fine grid by using optimization techniques. It coarsely scans the 1D landscape to find initialization simultaneously for all frequencies followed by parallelizable local refinement via gradient descent. We also analyze its performance when the noise level is sufficiently small and the signal frequencies are separated by at least 8π/m, where π/m is the standard resolution of this problem. Even though the 1D landscape is nonconvex, we prove a global convergence result for Gradient-MUSIC: coarse scanning provably finds suitable initialization and gradient descent converges at a linear rate. In addition to convergence results, we also upper bound the error between the true signal frequencies and amplitudes with those found by Gradient-MUSIC. For example, if the noise has $\ell^\infty$ norm at most ϵ, then the frequencies and amplitudes are recovered up to error at most Cϵ/m and Cϵ respectively, which are minimax optimal in m and ϵ. Our theory can also handle stochastic noise with performance guarantees under nonstationary independent Gaussian noise. Our main approach is a comprehensive geometric analysis of the landscape, a perspective that has not been explored before.

97 MATHEMATICS AND COMPUTING↗

The MUSIC Critical Benchmark and Nuclear Data

The Measurement of Uranium Subcritical and Critical (MUSIC) experiment was a series of measurements of critical and subcritical configurations of bare highly enriched uranium. The goal was to compare measurement methods, analysis techniques, and simulation methods across regimes of criticality and to provide high-quality validation of 235 U nuclear data. A benchmark evaluation of the two critical configurations of the MUSIC experiments will soon be published in the release of the International Criticality Safety Benchmark Evaluation Project Handbook. The recent execution of the experiment aids in proper quantification of model simplifications and all uncertainties associated with the experiment. Historical benchmark evaluations are heavily relied on for uranium nuclear data validation despite the fact that the same level of documentation and comparable uncertainty analysis may not be present. The MUSIC evaluation is less likely to include “unknown unknowns” that could impede accurately modeling the system. Presented are both highly detailed and very simplified models, which represent the experimental configurations accurately, aiding the users of the benchmark for nuclear data or transport code validation. The sensitivities of k eff to nuclear data and nuclear data–related uncertainties are very similar between this experiment and previous bare uranium sphere experiments. In addition, the nuclear data uncertainties to any nuclides other than 235 U are small. For all these reasons, the recently evaluated MUSIC benchmark critical configurations could prove very useful for 235 U nuclear data validation. Currently, major libraries have good agreement with the experimental results, within 200 pcm for all nuclear data libraries, and within one standard deviation of the experimental result for most. Suggested nuclear data adjustments based on MUSIC and Lady Godiva are also presented, with posterior improvements to both the agreement in k eff and the uncertainty associated with the nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improving the characterization of fusion in a MuSIC detector by spatial localization

Multi-Sampling Ionization Chambers (MuSIC) provide an efficient means of measuring nuclear reactions with low beam rates (< 10 6 pps). However, in comparison to thin-target measurements, prior measurements using MuSIC detectors all manifest fusion excitation functions with wide error bars in the energy dimension. This uncertainty limits the applicability of these devices in measuring near and sub-barrier fusion cross-sections. Key to overcoming this limitation is spatial localization of the fusion in the detector. By comparing the measured ionization in the MuSIC detector with accurate energy loss calculations the position of the fusion in the detector is determined. The analysis not only provides the desired improvement in energy resolution, but it also allows extraction of the atomic number of the evaporation residues following fusion. Furthermore, the effectiveness of this approach is demonstrated for 18 O+ 12 C measured with MuSIC@Indiana.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New physics at the Muon (Synchrotron) Ion Collider: MuSIC for several scales

A Muon (Synchrotron) Ion Collider (MuSIC) can be the successor to the Electron-Ion Collider at Brookhaven National Laboratory, as well as the ideal demonstrator facility for a future multi-TeV Muon Collider. Besides its rich nuclear physics and Standard Model particle physics programs, in this work we show that the MuSIC with a TeV-scale muon beam offers also a unique opportunity to probe New Physics. In particular, the relevant searches have the potential to surpass current experimental limits and explore new regimes of the parameter space for a variety of Beyond the Standard Model scenarios including: lepton-flavor violating leptoquarks, muonphilic vector boson interactions, axion-like particles coupling to photons, and heavy sterile neutrinos. Depending on the particular case, the sensitivity of the searches in the MuSIC may span a wide range of energy scales, namely from sub-GeV particles to the few TeV New Physics mediators. Our analysis demonstrates that the MuSIC can strike a powerful chord in the search for New Physics, thanks to unique combination of features that amplify its capabilities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Classification of events from α -induced reactions in the MUSIC detector via statistical and ML methods

The Multi-Sampling Ionization Chamber (MUSIC) detector is typically used to measure nuclear reaction cross sections relevant for nuclear astrophysics, fusion studies, and other applications. From the MUSIC data produced in one experiment scientists carefully extract an order of 10 3 events of interest from about 10 9 total events, where each event can be represented by an 18-dimensional vector. However, the standard data classification process is based on expert driven, manually intensive data analysis techniques that require several months to identify patterns and classify the relevant events from the collected data. Here, to address this issue, we present a method for the classification of events originating from specific α-induced reactions by combining statistical and machine learning methods that require significantly less input from the domain scientist, relative to the standard technique. Here, we applied the new method to two experimental data sets and compared our results with those obtained using traditional methods. With few exceptions, the number of events classified by our method agrees within ±20% with the results obtained using traditional methods. With the present method, which is the first of its kind for the MUSIC data, we have established the foundation for the automated extraction of physical events of interest from experiments using the MUSIC detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-phase accurate multiplexed structured image capture (2pAc-MUSIC)

Multiplexed Structural Image Capture (MUSIC) technique uses modulation of light from a scene prior to imaging to encode the temporal evolution of target into spatial frequency shifts, with each shift corresponding to a unique time and resulting in individual distinct snapshots. Computational-processing of the multiplexed single-shot image can recover the nanosecond-resolution scene evolution. One of the limitations is the loss of spatial resolution of the recovered image due to limitations of the low-pass spatial frequency filtering depth. Here we demonstrated that two images with complementary spatial phases can be used to enhance the spatial resolutions. For this application, 2 Phase Accurate (2pAc)-MUSIC is implemented that a scene is encoded with two complementary phases. The increased spatial information captured reduces the lower frequency noise in the Fourier domain found in single-phase MUSIC. A recovery algorithm combines the 180-degree spatial frequency shifted images into a single scene and applies a spatial filter in the Fourier domain that has a larger depth than previously possible to achieve a scene with increased spatial resolution. The 2pAc-MUSIC can effectively enhance the spatial resolution by removing the overlapping zero-order spatial frequencies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MuSIC@Indiana: An effective tool for accurate measurement of fusion with low-intensity radioactive beams

The design, construction, and characterization of the Multi-Sampling Ionization Chamber, MuSIC@Indiana, are described. This detector provides efficient and accurate measurement of the fusion cross-section at near-barrier energies. The response of the detector to low-intensity beams of 17,18 O, 19 F, 23 Na, 24,26 Mg, 27 Al, and 28 Si at E lab 50–60MeV was examined. MuSIC@Indiana was commissioned by measuring the 18 O+ 12 C fusion excitation function for 11 < E cm < 20 MeV using CH 4 gas. Here, a simple, effective analysis cleanly distinguishes proton capture and two-body scattering events from fusion on carbon. With MuSIC@Indiana, measurement of 15 points on the excitation function for a single incident beam energy is achieved. The resulting excitation function is shown to be in good agreement with literature data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Prospective Randomized Trial of the Influence of Music on Anxiety in Patients Starting Radiation Therapy for Cancer

One of the most downloaded articles in 2017 from the International Journal of Radiation Oncology, Biology, and Physics was a study suggesting that music therapy during radiation therapy (RT) simulation substantially reduces anxiety. To further evaluate the potential of music's clinical efficacy in the context of radiation therapy, we conducted a randomized trial evaluating the influence of genre-based music chosen by the study participant on anxiety during the first RT treatment session with a method that is applicable to routine clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prediction of alkaline earth metal ion adsorption on goethite for various background electrolytes with the CD-MUSIC model

As water scarcity drives the use of more saline water sources, contaminant fate and transport models must capture the impact of high concentrations of alkaline earth metal ions (AEMs) and background electrolytes in these more complex waters. By utilizing macroscopic adsorption data from various electrolyte systems, a Charge Distribution – Multisite Complexation (CD-MUSIC) model, capable of incorporating electrolyte adsorption, was able to accurately simulate the adsorption behavior of alkaline earth metal ions onto goethite. The modeling effort was guided by previous spectroscopic and surface complexation modeling of alkaline earth metal adsorption and built on previous CD-MUSIC modeling that accounted for changes in crystal face contributions to the surface site density as a function of specific surface area. Further, the model was constrained to consider only two dominant surface complex species for each metal ion adsorption reaction. These two species were selected from 44 possible species through objective curve fitting of single-solute macroscopic adsorption data. While most of the alkaline earth metal surface complexes formed outer-sphere complexes at the goethite surface, an inner-sphere species was utilized for Mg 2+ . With the surface complex species and equilibrium constants obtained from this study, the calibrated model successfully predicted alkaline earth metal ion adsorption over a wide range of solution and surface conditions; the model predictions encompassed a wide range of pH (5–11), solute/solid ratio (1.37 × 10 -5 – 8.33 × 10 -4 mol -solute /g -solid ), ionic strengths (0.01 M – 0.7 M), and background electrolytes (Na + , Cs + , Rb + , Cl - , and NO 3 - ) using the same crystal face contribution methodology for site density, capacitance values, and surface acidity constants adopted for proton and cadmium adsorption in previous work (Han and Katz, 2019). Model simulations for a range of background water chemistries demonstrated the potential for Mg 2+ to reduce Cd 2+ adsorption to goethite in model seawater and oil- and gas-produced waters.

42 ENGINEERING↗

MUSiC: Critical Experiment with Bare Highly Enriched Uranium Shells Benchmark

The measurements of the Uranium Subcritical and Critical (MUSiC) experiment were performed from December 2020 through April 2021. The purpose of the experiment was to test a variety of multiplicity detection systems for a large range of multiplication values and to see how well they perform as the k eff of the MUSiC series of experiments approached the delayed critical window. Out of the ten configurations that were studied, two of them were super critical and were recently approved as benchmarks and they will be included in the International Criticality Safety Benchmark Evaluation Project (ICBESP) handbook. For each of the two experiments, uncertainties were evaluated six categories: (1) critical measurement, (2) mass, (3) composition, (4) positioning, (5) dimensions, and (6) temperature. The largest contribution to the overall uncertainty in each of the cases was due to the uncertainties in the dimensions of the HEU Rocky Flats shells. Simplified detailed models were created with an average bias of -130.5 pcm due to the removal various components surrounding the experiment. For MCNP6.2 models using ENDF-VIII.0 neutron cross section data, the average difference between the calculated and benchmark k effs was -54 pcm for the detailed model and -102 pcm for the simplified model.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MUSiC: a model-unspecific search for new physics in proton–proton collisions at $\sqrt{s} = 13\,\text {TeV} $

Results of the Model Unspecific Search in CMS (MUSiC), using proton–proton collision data recorded at the LHC at a centre-of-mass energy of 13TeV, corresponding to an integrated luminosity of 35.9 fb -1 , are presented. The MUSiC analysis searches for anomalies that could be signatures of physics beyond the standard model. The analysis is based on the comparison of observed data with the standard model prediction, as determined from simulation, in several hundred final states and multiple kinematic distributions. Events containing at least one electron or muon are classified based on their final state topology, and an automated search algorithm surveys the observed data for deviations from the prediction. The sensitivity of the search is validated using multiple methods. No significant deviations from the predictions have been observed. For a wide range of final state topologies, agreement is found between the data and the standard model simulation. This analysis complements dedicated search analyses by significantly expanding the range of final states covered using a model independent approach with the largest data set to date to probe phase space regions beyond the reach of previous general searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Progress Update on the MUSIC Critical Benchmark

The Measurement of Uranium Subcritical and Critical (MUSiC) experiment was carried out from December 2020 through April 2021 at the National Criticality Experiments Research Center (NCERC). This measurement campaign featured bare configurations of the Rocky Flats highly-enriched uranium (HEU) shells, with each configuration having different numbers of these shells. The goal of the experiment was to test multiple neutron multiplicity detectors and measurement methods for a large range of neutron multiplication values. The large range of multiplications allows researchers to see when the combination of detectors and methods break down as the configurations reach the delayed supercritical window. The critical configurations were the extreme end of the multiplication range in MUSIC configurations. A critical benchmark in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook is planned to help further validate nuclear data. Even though there are many benchmarks focusing on the fast spectrum for highly-enriched uranium, an additional benchmark that is well documented and up to the modern standard of the handbook would be a welcome addition. Given that there are no other materials such as moderators or significant reflectors, and its similarity to Lady Godiva, it is possible that this could be very useful for validation of 235 U nuclear data in the future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Future of the MUSiC Experiment Data

The Measurements of Uranium Subcritical and Critical (MUSiC) experiment was a highly enriched uranium (HEU) experiment performed at the National Criticality Experiments Research Center (NCERC) executed between December 2020 and April 2021. The experiment intended to measure criticality and reactor kinetics parameters in a bare HEU system. The experiment concurrently measured radiation signatures from the system while utilizing different neutron source types. This was an attempt to benchmark both detectors and analysis techniques against one another for identical measurements. The experiment consisted of the Rocky Flats HEU hemi-shells constructed into ten configurations spanning between deeply subcritical (about 14 kgs) to supercritical (about 60 kgs). Two of the ten configurations were supercritical and the other eight were subcritical. The two supercritical configurations, often referred to as the critical configurations, were documented into an International Criticality Safety Benchmark Evaluation Project (ICSBEP) benchmark evaluation and submitted to the technical review group (TRG). The subcritical configurations of the MUSiC experiment were examined using three different detection systems. The systems include: the NoMAD He-3 neutron detector which consists of 15 He-3 tubes surrounded by a polyethylene matrix, a liquid scintillator system called the Rossi-α Measurement Rapid Organic Discriminating Detector (RAM-RODD), and a trans-stilbene organic scintillator array (OSCAR) provided by the University of Michigan. The NoMAD and RAM-RODD data are planned to be evaluated in two separate ICSBEP evaluations utilizing neutron noise methods such as Feynman Variance-to-Mean, Rossi-α and the pulsed neutron source method. Each of the subcritical configurations were examined using three different source types including: a Cf-252 source in the center, with only the intrinsic neutron source in the HEU, and with an external D-T neutron generator.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preliminary RAM-RODD results for the MUSiC subcritical configurations

The Measurement of Uranium Subcritical and Critical (MUSiC) was performed at the DOE’s National Criticality Experiments Research Center (NCERC) located in the Nevada National Security Site (NNSS). The measurement utilized the Rocky Flats shells to perform benchmark measurements of similar highly enriched uranium (HEU) systems that span a wide range of reactivities. The Rocky Flats (RF) shells are 93.16% U-235 enriched metal hemishells that can be stacked concentrically. Ten configurations were measured with effective multiplication factors spanning between deeply subcritical (~ 0.64) through delayed critical. Details of the measured configurations are listed in Table 1. This unique set of measurements with its large span of reactivies is being used to determine the range over which neutron noise techniques such as Feynman variance-to-mean, Rossi-alpha, and pulsed neutron source techniques can be accurately employed for a bare HEU system. The results of the measurements will be published as a benchmark in The International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The results will support the growing amount of subcritical benchmark data, such as the SCRaP measurements, that is available to the community. The measurements were performed using several different detector systems for the purposes of cross-validation and obtaining detector independent results. Four detector systems were deployed, three by the NCERC team and one from the University of Michigan. The detector systems included a Neutron Multiplicity Array Detector (NoMAD) system (similar to the MC-15), four small volume 0.635 cm (Ø) × 7.59 cm 3 He detectors (ideal for measuring prompt neutron decay constants due to their fast recovery speed), the Rossi Alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAM-RODD), and the Organic Scintillator Array (OSCAR). RAM-RODD is an array of eight 5.08 cm (Ø) × 5.08 cm EJ-309 organic scintillator detectors. OSCAR is a University of Michigan system and is an array of twelve 5.08 cm (Ø) × 5.08 cm stilbene detectors. Details of measurements performed with OSCAR will be discussed in a separate talk. The focus of this work is preliminary results obtained by RAM-RODD for the 8 subcritical configurations. Additional details on the measurements and on the setup and deployment of RAM-RODD will be discussed. Preliminary neutron noise analysis results including Rossi-alpha and Feynman-alpha will also be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary NoMAD Results of the MUSIC Experiment

The Measurement of Uranium Subcritical and Critical (MUSiC) experiment was carried out from December 2020 through April 2021 at the National Criticality Experiments Research Center (NCERC). This measurement campaign featured bare configurations of the Rocky Flats highly-enriched uranium (HEU) shells, with each configuration having different numbers of these shells. The goal of the experiment was to test multiple neutron multiplicity detectors and measurement methods for a large range of neutron multiplication values, to see when the combination of detectors and methods break down as the configurations reach the delayed supercritical window. Adding subcritical integral benchmarks gives additional validation to nuclear data. These benchmarks provide additional parameters against which to validate the data. While critical benchmarks have just a single value, $K_{eff}$ , subcritical benchmarks can be used to infer multiple parameters. As an example, recent subcritical benchmarks utilizing the Hage-Cifarelli formalism have three quantities of interest ($R_{1}$, $R_{2}$, and $M_{L}$). This gives nuclear data evaluators additional data to use when performing their evaluations, and allows for these benchmarks to be useful for additional types of nuclear data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Super-resolution demodulation for fiber sensor arrays based on the MUSIC algorithm

This paper studies the use of MUltiple SIgnal Classification (MUSIC) as a super-resolution algorithm to improve demodulation results for intrinsic Fabry–Perot interferometer (IFPI) sensor arrays. Through distinction between noise and signal subspaces in an observation matrix, this paper shows that a 38-fold improvement in the full width at half maximum (FWHM) estimation of IFPI optical path differences (OPD) can be achieved using this algorithm. Based on this improved method, this paper demonstrates that a tunable laser with a 1.3-nm tuning range can achieve the same sensor demodulation performance as a tunable laser with a 50-nm tuning range if a conventional Fourier transform-based algorithm is used. This paper presents a new approach to analyzing optical signals produced by multiple multiplexed interferometers with similar OPDs with potential applications for both single-mode and multiple-mode devices.

Li, Yuqi (ORCID:0000000291643663)↗

IER 488: MUSiC Accomplishments and Goals [Slides]

IER-488: Measurement of Uranium Subcritical and Critical (MUSiC) consists of measurements of bare, HEU systems covering a large range of reactivities. Multiple detector systems and analysis methods are being used to obtain detector-independent results. Massive amounts of data and information available. Substantial analysis has been completed for both critical and subcritical configurations. Work in progress is largely novel research and will result in several conference proceedings, journal publications, and a subcritical benchmark. There is still a large amount of data that has not been analyzed and much more to come from the analysis of the Measurements of Uranium Subcritical and Critical.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗