Search NASA⌕ Search

SEARCH · Search NASA

Results for “N95 masks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Charging Experiments and Filtration Testing on Facemask Materials: Towards Goals of Full Performance Restoration of Used N95 Masks and Enhancement of Common-Fabric Facemasks

Different techniques have been developed for sanitizing N95 masks while retaining whatever charge remains on them. However, these sanitizing methods do not address the fact that the electrical charge, filtration efficacy, and breathability of such masks may be expected to degrade during long-term use based on mechanisms known in the literature. In this study, approaches to electrically (re)charging facemask filter materials were explored in response to the COVID-19 induced shortage of N95 masks. The effort consisted of charging experiments followed by filtration testing conducted at the coupon level during a month-long period (May 2020). The main focus of the work was to develop a recharging technique which could eventually be adapted and used as part of a broader full-performance restoration process for used N95 masks, e.g., which might employ simple washing by alcohol or soapy water as a preceding step for sanitization and declogging. Most tested coupons were therefore nonwoven meltblown fibrous polypropylene (PP) filter media extracted from decades old N95 masks. Keeping in mind commonly used cloth facemasks, limited trials were also performed with some commercially available fabrics. Charging was done at elevated temperature and was followed by cooling to freeze in the applied charges produced from corona discharges using different electrode configurations and parameter combinations, or from triboelectric rubbing. Charging was also focused on using potentially scalable equipment, e.g., Van de Graaff generators or consumer ionic hair products. Some degree of success was achieved with one of the fabrics and the PP filter media which was first purposefully discharged to have typical filtration efficiency (FE) of ~35%. Numerous attempts at corona charging discharged media resulted in filtration efficiency (FE) ≥ 80 – 85%. Some measure of charge robustness was also established via stable performance during loading testing. However, results where FE ≥ 90% were not reliably repeatable and no results met the FE ≥ 95% goal due to shortcomings of the charging process. The best three trials for PP media statistically met the FE ≥ 90% criteria, amounted to a small percentage of the trials relying on an ionic hair dryer, and are attributed to good embedding of charges via aerodynamic force. Triboelectric charging significantly enhanced the viability of one of the polyester fabrics –measured FE increased from 19% up to 46% while maintaining a reasonably low pressure drop.

N95↗

Supercritical CO2 sterilization of N95 Masks

A preliminary investigation of the use of supercritical carbon dioxide for treating of 3M 1860 N95 masks was undertaken to evaluate a potential route to low-cost, scalable, sterilization of personal protective equipment for multiple reuse in hospital settings. Upon entering the supercritical regime, the normally distinct liquid and gaseous phases of CO 2 merge into a single homogeneous phase that has density, short-range order, and solvation capacity of a liquid, but the volume-filling and permeation properties that of a gas. This enables supercritical CO2 to function as a vehicle for delivery of biocidal agents such peracetic acid into microporous structures. The potentially adverse effect of a liquid-to-gas phase transition on mask filter media is avoided by conducting cleaning operations above 31 C, the critical temperature for carbon dioxide. A sample of fifteen 3M 1860 N95 masks was subjected to ten consecutive cycles of supercritical CO 2 cleaning to determine its effect on mask performance. These 15 masks, along with 5 control samples then underwent a battery of standardized tests at the CDC NIOSH NPPTL research facility in Pittsburgh, PA. The data from these tests strongly suggest (but do not prove) that supercritical carbon dioxide do not damage 3M 1860 N95 masks. Additional tests conducted during this project confirmed the compatibility of supercritical CO 2 with ventilator tubing that, like N95 masks, has been in short supply during portions of the COVID-19 pandemic and cannot be sterilized by conventional means. Finally, a control experiment was also conducted to examine the effect of supercritical CO 2 on a BSL-2 surrogate virus, vesicular stomatitis virus (VSV), Indiana serotype strain. In the absence of biocidal additives, supercritical CO 2 exhibited no measurable lethality against VSV. This surrogate virus experiment suggests that a biocidal additive such as peracetic acid will be necessary to achieve required sterilization metrics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Durability of Disposable N95 Mask Material When Exposed to Improvised Ozone Gas Disinfection

The principle finding of this report is that both commercial and a novel material used for N95 mask filters can endure many cycles of disinfection by ozone gas (20 ppm for 30 minutes) without detectable degradation or loss of filtration efficiency. N95 masks and surgical masks (hereafter referred to as masks) typically use a filtration material fabricated from meltblown polypropylene. To achieve maximum filtration efficiency while maintaining a reasonable pressure drop, these nonwoven fabrics are also electrostatically charged (corona discharge is the most common method used), to maximize attraction and capture of aerosols and solid particulates. Under normal circumstances, the reuse of masks is generally discouraged, but in times of crisis has become a necessity, making disinfection after each use a necessity. To be acceptable, any disinfection procedure must cause minimal degradation to the performance of the filter material. Possible performance degradation mechanisms include mechanical damage, loss of electrostatic charge, or both. One of the most practical and direct ways to measure combined mechanical and electrostatic integrity, and the subsequent ability to reuse mask filter material, is by the direct measurement of filtration efficiency. In this paper, we report that small numbers of disinfection cycles at reasonable virucidal doses of ozone do not significantly degrade the filtration efficiency of meltblown polypropylene filter material. By comparison, laundering quickly results in a significant loss of filtration efficiency and requires subsequent recharging to restore the electrostatic charge and filtration efficiency. A common assumption among biomedical scientists that ozone is far too destructive for this application. However, these direct measurements show that mask materials, specifically the filtration material, can withstand dozens of ozone disinfection cycles without any measurable degradation of filtration efficiency, nor any visible discoloration or loss of fiber integrity. The data are clear: when subjected to a virucidal dose of ozone for a much longer duration than is required for viral inactivation, there was no degradation of N95 filtration efficiency. The specific dosages of ozone needed for ~99% viral inactivation are thought to be at least 10 ppm for up to 30 minutes based upon an extensive literature review, but to standardize our testing, we consider a dose of 20 ppm for 30 minutes to be a reasonable and conservatively high ozone disinfection cycle. Finally, the material tested in this study withstood dosages of up to 200 ppm for 90 minutes, or alternatively 20 ppm for up to 36 hours, without detectable degradation, and further testing suggests that up to 30 or more disinfection cycles (at 20 ppm for 30 minutes) would result in less than a 5% loss of filtration efficiency. This report does not address the effect of ozone cycling on other mask components, such as elastics.

60 APPLIED LIFE SCIENCES↗

Effective antiviral coatings for deactivating SARS-CoV-2 virus on N95 respirator masks or filters

The application of antiviral coatings to masks and respirators is a potential mitigating step toward reducing viral transmission during the SARS-CoV-2 (severe acute respiratory syndrome coronavirus 2) pandemic. The use of appropriate masks, social distancing, and vaccines is the immediate solution for limiting the viral spread and protecting people from this virus. N95 respirator masks are effective in filtering the virus particles, but they cannot kill or deactivate the virus. We report a possible approach to deactivating SARS-CoV-2 by applying an antimicrobial coating (Goldshield 75) to masks and respirators, rendering them suitable for repeated use. Masks coated with Goldshield 75 demonstrated continuous inactivation of the Alpha and Beta variants of the SARS-CoV-2 over a 3-day period and no loss of inactivation when stored at temperatures at 50 °C.

36 MATERIALS SCIENCE↗

Dry heat sterilization as a method to recycle N95 respirator masks: The importance of fit

In times of crisis, including the current COVID-19 pandemic, the supply chain of filtering facepiece respirators, such as N95 respirators, are disrupted. To combat shortages of N95 respirators, many institutions were forced to decontaminate and reuse respirators. While several reports have evaluated the impact on filtration as a measurement of preservation of respirator function after decontamination, the equally important fact of maintaining proper fit to the users’ face has been understudied. In the current study, we demonstrate the complete inactivation of SARS-CoV-2 and preservation of fit test performance of N95 respirators following treatment with dry heat. We apply scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM/EDS), X-ray diffraction (XRD) measurements, Raman spectroscopy, and contact angle measurements to analyze filter material changes as a consequence of different decontamination treatments. We further compared the integrity of the respirator after autoclaving versus dry heat treatment via quantitative fit testing and found that autoclaving, but not dry heat, causes the fit of the respirator onto the users face to fail, thereby rendering the decontaminated respirator unusable. Our findings highlight the importance to account for both efficacy of disinfection and mask fit when reprocessing respirators to for clinical redeployment.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ozone Gas: Scientific Justification and Practical Guidelines for Improvised Disinfection using Consumer-Grade Ozone Generators and Plastic Storage Boxes

Here, we describe direct measurements of ozone concentration achievable in small enclosed containers (plastic storage boxes) for use as improvised decontamination systems for small articles such as disposable PPE (N95 masks, nitrile gloves, etc.), clothing, mail and small packages, food, and other miscellaneous articles. The emphasis is on the reliable and sustained generation of ozone gas concentrations of sufficient concentration and duration to create an effective virucidal environment to achieve more than 95% to 99% viral inactivation, based upon the data already published in the peer-review literature on this topic. The suggestion that ozone be used to inactivate virus is certainly not a new idea. Our objective in this report is to make clear that the necessary levels of ozone can be improvised using simple, easy-to-use, inexpensive, and widely available supplies, and that there is every theoretical and experimental reason to believe that this approach is as highly effective in viral inactivation by ozone as are the far more expensive, complex, cumbersome, and less available equivalent ozone (and other) disinfectant systems that have themselves become unavailable during times of pandemic crisis. Using multiple types of readily available commercial ozone generators, concentration in the tested improvised enclosure is tracked over time to assess ozone charging and decay rates, and the ozone quenching effects of items placed in the box. Generator performance is compared against published ozone dosage values for virucidal and antimicrobial activity. Bubbler and box-fan-type ozone generators were found to be effective at achieving and maintaining target concentrations of 10ppm ozone or higher, whereas automotive cigarette lighter and universal serial bus type plug in “air freshener” ozone generators could not achieve the target concentrations in these experiments. Calculations and practical guidelines for assembly and effective use of an ozone box for improvised decontamination are offered. The majority of this report is directed toward the scientific justification and rationale for this approach. The end of the document summarizes the findings and offers simplified designs for the construction and use of ozone boxes as an improvised method of disinfection.

60 APPLIED LIFE SCIENCES↗

Polymer, Additives, and Processing Effects on N95 Filter Performance

The current severe acute respiratory syndrome coronavirus 2 (SARS-COV-2) pandemic has highlighted the need for personal protective equipment, specifically filtering facepiece respirators like N95 masks. While it is common knowledge that polypropylene (PP) is the industry standard material for filtration media, trial and error is often required to identify suitable commercial precursors for filtration media production. This work aims to identify differences between several commercial grades of PP and demonstrate the development of N95 filtration media with the intent that the industry partners can pivot and help address N95 shortages. Three commercial grades of high melt flow index PP were melt blown at Oak Ridge National Laboratory and broadly characterized by several methods including differential scanning calorimetry (DSC), X-ray diffraction (XRD), and neutron scattering. Despite the apparent similarities (high melt flow and isotacticity) between PP feedstocks, the application of corona charging and charge enhancing additives improve each material to widely varying degrees. From the analysis performed here, the most differentiating factor appears to be related to crystallization of the polymer and the resulting electret formation. Materials with higher crystallization onset temperatures, slower crystallization rates, and larger number of crystallites form a stronger electret and are more effective at filtration.

36 MATERIALS SCIENCE↗

Domestic Supply Chain of Medical Consumables Needed During COVID-19 Pandemic

This report is an assessment of the availability, demand, and production capability of medical consumables needed to combat the COVID-19 pandemic. We focus here on the ability of the supply chain to increase production to meet demand during peak pandemic conditions. In addition, we report on domestic production efforts and supply chain issues, as well as the propensity of other countries to limit export of needed medical supplies to the United States. In brief, the domestic supply chain and production capability vary greatly depending on the consumable. Some consumables, such as N95 masks or face shields, can likely be nearly fully supplied by domestic production, while other consumables, such as gloves or surgical masks, have little domestic production and thus will depend on imports to meet demand. The assessment pulls primarily from published news sources and company press releases. As such, the demand and production numbers are not precisely known, and some degree of uncertainty exists in them. The total production capability is also often difficult to ascertain from these reports especially as other industries have begun to supplement existing supply chains. In addition, local conditions (including company financial decisions, local public health issues, and political aspects) can vary throughout the pandemic which will affect future production. The report also pulls from estimates of demand and domestic production of some consumables compiled by the White House COVID-19 Supply Chain Taskforce (SCTF) presented by Rear Admiral John Polowczyk before a June 9, 2020 hearing of the Senate Homeland Security and Governmental Affairs Committee. These numbers, where applicable, are likely to be more accurate than those found in public news sources since they are more directly tied to private companies’ actual orders and actual production estimates, as opposed to publicly released estimates. Finally, we note that other issues with the supply chain, including the production of raw materials, increase demand due to industries that have not previously used PPE now using it, and increased domestic production from non-traditional suppliers, make complete picture of a rapidly changing supply chain difficult to obtain. This report attempts to produce an accurate image of the supply and estimated demand, as understood by the authors who are not experts in the medical supply chain.

42 ENGINEERING↗

Self-Disinfecting Polymeric Coatings

A novel derivative of a previously-published polymeric material has been synthesized and developed into an easily-sprayable coating. Surface characterization of coatings confirm correct elemental presence, and viral assays reveal quantitative elimination of MS2 bacteriophage and Phi6 bacteriophage, surrogates used for SARS-CoV-2, in as little as 5 minutes upon contact. Furthermore, an N95 mask was dip-coated in the polymer solution and analyzed through microscopy and filtration efficacy testing. Though coating was successful, electrostatic interactions between mask layers and polymer reduced filtration efficacy significantly. As such, we expect the current results of this work to be applicable on non-respiratory PPE and on solid substrates of commonly-touched surfaces for rapid self-decontamination.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation and optimization for the decontamination/sterilization of personal protective equipment using a novel ozone chamber (CRADA Final Report)

Personal protective equipment slows the spread of the SARS-Cov-2 virus and protects first responders and the general population. However, there is a significant and well-publicized shortage of personal protective equipment for healthcare workers. Treatment with ozone may be a compelling, affordable, and scalable method to rapidly decontaminate personal protective equipment but more work is needed to verify these claims. Together with colleagues at the University of Nevada Reno and FATHHOME we helped design the experiments that evaluated the virucidal efficacy of FATHHOME’s device on N95 face masks and face shields. The results of our study were published in the journal Pathogens.

60 APPLIED LIFE SCIENCES↗

Alternative Materials for Mask Construction by the Public

N95 respirators became scarce to the general public in mid-to-late March of 2020 due to the SARS-CoV-2 epidemic. By mid-April of 2020, most states in the United States were requiring face coverings to be worn while in public enclosed places and in busy outdoor areas where groups of people were in close proximity. Many resorted to cloth masks, homemade masks, procedure masks obtained through online purchases, and other ad-hoc means. Thus, there was and still is a need to determine the aerosol filtration efficacy of commonly available materials that can be used for homemade mask construction. This study focused on non- woven polymeric fabrics that are readily available for homemade mask construction. The conclusion of this study is that non-woven materials that carry a high electric charge or those that can easily acquire charge had the highest aerosol filtration efficiency per unit of pressure drop. Future work should examine a wider variety of these materials and determine the maximum pressure drop that a nominal homemade mask can withstand before a significant portion of airflow is diverted around the mask. More broadly, a better understanding of the charge state on non-woven materials and impact of that charge state on filtration efficiency is needed.

36 MATERIALS SCIENCE↗

Can disposable masks be worn more than once?

Disposable facemasks are a primary tool to prevent the transmission of SARS-COV-2 during the COVID-19 pandemic. However, plastic waste generated from their disposal represents a significant environmental problem that can be reduced by maximizing the service life of disposable masks. We evaluated the effect of repeated wearing on the fitted filtration efficiency (FFE) of N95, KF94, KN95, and procedure/surgical masks. The FFEs of masks were compared following extended wearing with and without washing. Results reveal that most disposable facemasks can retain a high level of their baseline FFE after extended wearing, even after 40 h of wearing. Laundering disposable masks degraded FFE in some instances. We conclude that the durability of disposable facemask performance is considerably longer than their intended single use indication, suggesting that reusing disposable masks is a safe means of reducing plastic waste in the environment.

54 ENVIRONMENTAL SCIENCES↗

Characterization of Materials Used as Face Coverings for Respiratory Protection

Use of masks is a primary tool to prevent the spread of the novel COVID-19 virus resulting from unintentional close contact with infected individuals. However, detailed characterization of the chemical properties and physical structure of common mask materials is lacking in the current literature. In this study, a series of commercial masks and potential mask materials, including 3M Particulate Respirator 8210 N95, a material provided by Oak Ridge National Laboratory Carbon Fiber Technology Facility (ORNL/CFTF), and a Filti Face Mask Material, were characterized by a suite of techniques, including scanning electron microscopy, X-ray diffraction, Raman spectroscopy, and X-ray photoelectron spectroscopy. Wetting properties of the mask materials were quantified by measurements of contact angle with a saliva substitute. Mask pass-through experiments were performed using a dispersed metal oxide nanoparticle suspension to model the SARS-CoV-2 virus, with quantification via spatially resolved X-ray fluorescence mapping. Notably, all mask materials tested provided a strong barrier against respiratory droplet breakthrough. The comparisons and characterizations provided in this study provide useful information when evaluating mask materials for respiratory protection.

36 MATERIALS SCIENCE↗

Evaluation of an Additively Manufactured Respirator for Personnel Protection from Particulates

Additively manufactured respirators (AMRs) made using rigid plastic can be fitted with repurposed filter media to yield a wearable mask capable of passing a quantitative fit test with criteria set for commercial, N95 health care particulate respirators. This has been verified through an evaluation study assessing AMR masks fabricated using open-source design files and a commercial fused-filament fabrication machine, using N95 filter cloth and a P100 respirator cartridge. A few examples of filter media not designed for human respiratory protection were also evaluated in an AMR mask but did not demonstrate filtering sufficient to pass the N95 test criteria. All attributes of an AMR mask system must be considered during design and when testing performance, including the mask frame, gasket, and the cord used to secure the mask to the face. AMR masks are not the same as commercially available respiratory masks. If AMR masks are used as personal protective equipment (PPE) during a crisis when there is a shortage of regular PPE it is important that wearers are fully informed of the differences, tradeoffs, and risks associated with their use. Quantitative fit testing and proper training on how to don and doff the AMR mask are important to help achieve the best possible outcome when they are used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A scalable method of applying heat and humidity for decontamination of N95 respirators during the COVID-19 crisis

A lack of N95 Filtering Facepiece Respirators (FFRs) during the COVID-19 crisis has placed healthcare workers at risk. It is important for any N95 reuse strategy to determine the effects that proposed protocols would have on the physical functioning of the mask, as well as the practical aspects of implementation. Here we propose and implement a method of heating N95 respirators with moisture (85°C, 60-85% humidity). We test both mask filtration efficiency and fit to validate this process. Our tests focus on the 3M 1860, 3M 1870, and 3M 8210 Plus N95 models. After five cycles of the heating procedure, all three respirators pass both quantitative fit testing (score of >100) and show no degradation of mask filtration efficiency. We also test the Chen Heng V9501 KN95 and HKYQ N95 finding no degradation of mask filtration efficiency, however even for unheated masks these scored <50 for every fit test. The heating method presented here is scalable from individual masks to over a thousand a day with a single industrial convection oven, making this method practical for local application inside health-care facilities.

59 BASIC BIOLOGICAL SCIENCES↗