Search NASA⌕ Search

SEARCH · Search NASA

Results for “NASA Program Environmental Health”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Gramicidin S production by Bacillus brevis in simulated microgravity

In a continuing study of microbial secondary metabolism in simulated microgravity, we have examined gramicidin S (GS) production by Bacillus brevis strain Nagano in NASA High Aspect Rotating Vessels (HARVs), which are designed to simulate some aspects of microgravity. Growth and GS production were found to occur under simulated microgravity. When performance under simulated microgravity was compared with that under normal gravity conditions in the bioreactors, GS production was found to be unaffected by simulated microgravity. The repressive effect of glycerol in flask fermentations was not observed in the HARV. Thus the negative effect of glycerol on specific GS formation is dependent on shear and/or vessel geometry, not gravity.

NASA Discipline Number 04-10↗

Secondary metabolism in simulated microgravity: beta-lactam production by Streptomyces clavuligerus

Rotating bioreactors designed at NASA's Johnson Space Center were used to simulate a microgravity environment in which to study secondary metabolism. The system examined was beta-lactam antibiotic production by Streptomyces clavuligerus. Both growth and beta-lactam production occurred in simulated microgravity. Stimulatory effects of phosphate and L-lysine, previously detected in normal gravity, also occurred in simulated microgravity. The degree of beta-lactam antibiotic production was markedly inhibited by simulated microgravity.

NASA Discipline Environmental Health↗

Environmental health program in NASA

The NASA policy on environmental health uses medical and environmental concepts to: (1) Determine the health status of employees; (2) prevent illness and promote good health among employees; and (3) identify and control factors that affect the health of personnel and quality of environment. Evaluation and control of physical, chemical, radiological and biological factors surrounding personnel and which represent physiological and psychological stresses and impairment are considered.

Marrazzo, R. M.↗

Alveolar ventilation to perfusion heterogeneity and diffusion impairment in a mathematical model of gas exchange

This study describes a two-compartment model of pulmonary gas exchange in which alveolar ventilation to perfusion (VA/Q) heterogeneity and impairment of pulmonary diffusing capacity (D) are simultaneously taken into account. The mathematical model uses as input data measurements usually obtained in the lung function laboratory. It consists of two compartments and an anatomical shunt. Each compartment receives fractions of alveolar ventilation and blood flow. Mass balance equations and integration of Fick's law of diffusion are used to compute alveolar and blood O2 and CO2 values compatible with input O2 uptake and CO2 elimination. Two applications are presented. The first is a method to partition O2 and CO2 alveolar-arterial gradients into VA/Q and D components. The technique is evaluated in data of patients with chronic obstructive pulmonary disease (COPD). The second is a theoretical analysis of the effects of blood flow variation in alveolar and blood O2 partial pressures. The results show the importance of simultaneous consideration of D to estimate VA/Q heterogeneity in patients with diffusion impairment. This factor plays an increasing role in gas alveolar-arterial gradients as severity of COPD increases. Association of VA/Q heterogeneity and D may produce an increase of O2 arterial pressure with decreasing QT which would not be observed if only D were considered. We conclude that the presented computer model is a useful tool for description and interpretation of data from COPD patients and for performing theoretical analysis of variables involved in the gas exchange process.

NASA Discipline Environmental Health↗

Human performance and physiological function during a 24-hr exposure to 1% bromotrifluoromethane (Halon 1301)

Performance and physiological measurements were obtained from four pairs of men exposed for 24 hr to 1% (10,000 ppm) Halon 1301 (bromotrifluoromethane, CBrF3) and to air with order counterbalanced using a double-blind protocol. Cognitive and motor performance was assessed before, during, and after the exposures using seven scales of the Automated Portable Testing System, which produced 13 measures of performance. Halon inhalation induced decrements in 2 of the 13 measures, but actual and estimated magnitudes of the decrements were no greater than 5% of baseline values. Physiological data were obtained before, during, and after the exposures from clinical chemistry analyses of blood and urine samples, pulmonary function tests, and monitoring of vital signs. Significant change during Halon inhalation was observed for 6 of the 52 variables assessed; however, all physiological values remained within clinically acceptable limits. No cardiovascular effects were noted. This study demonstrated that exposure to 1% Halon 1301 for 24 hr can produce minor disturbance of central nervous system function as assessed by cognitive tasks.

Randomized Controlled Trial↗

Incorporating biologically based models into assessments of risk from chemical contaminants

The general approach to assessment of risk from chemical contaminants in drinking water involves three steps: hazard identification, exposure assessment, and dose-response assessment. Traditionally, the risks to humans associated with different levels of a chemical have been derived from the toxic responses observed in animals. It is becoming increasingly clear, however, that further information is needed if risks to humans are to be assessed accurately. Biologically based models help clarify the dose-response relationship and reduce uncertainty.

Review, Tutorial↗

Iodine susceptibility of pseudomonads grown attached to stainless steel surfaces

Pseudomonads were adapted to grow in phosphate-buffered water and on stainless steel surfaces to study the iodine sensitivity of attached and planktonic cells. Cultures adapted to low nutrient growth were incubated at room temperature in a circulating reactor system with stainless steel coupons to allow biofilm formation on the metal surfaces. In some experiments, the reactor was partially emptied and refilled with buffer at each sampling time to simulate a "fill-and-draw" water system. Biofilms of attached bacteria, resuspended biofilm bacteria, and reactor suspension, were exposed to 1 mg l-1 iodine for 2 min. Attached bacterial populations which established on coupons within 3 to 5 days displayed a significant increase in resistance to iodine. Increased resistance was also observed for resuspended cells from the biofilm and planktonic bacteria in the system suspension. Generally, intact biofilms and resuspended biofilm cells were most resistant, followed by planktonic bacteria and phosphate buffer cultures. Thus, biofilm formation on stainless steel surfaces within water systems can result in significantly increased disinfection resistance of commonly-occurring water-borne bacteria that may enhance their ability to colonise water treatment and distribution systems.

NASA Program Environmental Health↗

Colonization by Cladosporium spp. of painted metal surfaces associated with heating and air conditioning systems

Cladosporium cladosporioides and C. hebarum colonized painted metal surfaces of covering panels and register vents of heating, air conditioning and ventilation systems. Hyphae penetrated the paint film and developed characteristic conidiophores and conidia. The colonies were tightly appressed to the metal surface and conidia were not readily detectable via standard air sampling procedures.

NASA Program Environmental Health↗

Evaluation of the Biolog automated microbial identification system

Biolog's identification system was used to identify 39 American Type Culture Collection reference taxa and 45 gram-negative isolates from water samples. Of the reference strains, 98% were identified to genus level and 76% to species level within 4 to 24 h. Identification of some authentic strains of Enterobacter, Klebsiella, and Serratia was unreliable. A total of 93% of the water isolates were identified.

NASA Program Environmental Health↗

Evaluation of the Biolog MicroStation system for yeast identification

One hundred and fifty-nine isolates representing 16 genera and 53 species of yeasts were processed with the Biolog MicroStation System for yeast identification. Thirteen genera and 38 species were included in the Biolog database. For these 129 isolates, correct identifications to the species level were 13.2, 39.5 and 48.8% after 24, 48 and 72 hours incubation at 30 degrees C, respectively. Three genera and 15 species which were not included in the Biolog database were also tested. Of the 30 isolates studied, 16.7, 53.3 and 56.7% of the isolates were given incorrect names from the system's database after 24,48 and 72 h incubation at 30 degrees C, respectively. The remaining isolates of this group were not identified.

NASA Program Environmental Health↗

Fungal colonization of fiberglass insulation in the air distribution system of a multi-story office building: VOC production and possible relationship to a sick building syndrome

Complaints characteristic of those for sick building syndrome prompted mycological investigations of a modern multi-story office building on the Gulf coast in the Southeastern United States (Houston-Galveston area). The air handling units and fiberglass duct liner of the heating, ventilating and air conditioning system of the building, without a history of catastrophic or chronic water damage, demonstrated extensive colonization with Penicillium spp and Cladosporium herbarum. Although dense fungal growth was observed on surfaces within the heating-cooling system, most air samples yielded fewer than 200 CFU m-3. Several volatile compounds found in the building air were released also from colonized fiberglass. Removal of colonized insulation from the floor receiving the majority of complaints of mouldy air and continuous operation of the units supplying this floor resulted in a reduction in the number of complaints.

NASA Program Environmental Health↗

Effects of substrates and phosphate on INT (2-(4-iodophenyl)-3-(4-nitrophenyl)-5-phenyl tetrazolium chloride) and CTC (5-cyano-2,3-ditolyl tetrazolium chloride) reduction in Escherichia coli

The effects of substrates of primary aerobic dehydrogenases, and inorganic phosphate on aerobic INT and CTC reduction in Escherichia coli were examined. In general, INT produced less formazan than CTC, but INT (+) cell counts remained near values of CTC (+) cells. INT and CTC (+) cell numbers were higher than plate counts on R2A medium using succinate, formate, lactate, casamino acids, glucose, glycerol (INT only) and no substrate. Formate resulted in the greatest amount of INT and CTC formazan. Reduction of both INT and CTC was inhibited above 10 mmol l-1 phosphate, and this appeared to be related to decreased rates of O2 consumption. Formation of fluorescent CTC (+), but not INT (+) cells was also inhibited in a concentration dependent manner by phosphate above 10 mmol l-1. From light microscopic observations it appeared CTC formed increasing amounts of poorly or non-fluorescent formazan with increasing phosphate. Therefore, use of phosphate buffer in excess of 10 mmol l-1 may not be appropriate in CTC and INT reduction assays.

NASA Program Environmental Health↗

Breathing 100% oxygen compared with 50% oxygen: 50% nitrogen reduces altitude-induced venous gas emboli

The risk of venous gas emboli (VGE) and decompression sickness (DCS) must be determined before selection of the lowest pressure for an extravehicular activity (EVA) pressure suit which eliminates the requirement for prebreathing. In earlier studies, use of a 50% oxygen:50% nitrogen breathing mixture (50:50 mix) during 139 zero-prebreathe decompressions of male subjects to 8.3-7.8 psia resulted in 51 instances of severe VGE and one case of DCS. Our current study investigated effects of 40 zero-prebreathe decompressions of male subjects to 8.3-6.8 psia for 6 h while breathing 100% oxygen and performing moderate exercise. No DCS symptoms were observed. Severe VGE were not detected at 8.3 psia, but were present during 10%, 20%, and 40% of the exposures at 7.8, 7.3, and 6.8 psia, respectively. Zero-prebreathe decompression while breathing 100% oxygen results in significantly lower VGE and DCS risk levels than while breathing a 50:50 mix. Our results show that 7.3 psia EVA pressure suits with 100% oxygen should be safer than 8.3 psia suits with a 50:50 mix.

NASA Program Environmental Health↗

Effect of body repositioning after venous air embolism. An echocardiographic study

BACKGROUND: Current therapy for massive venous air embolism (VAE) may include the use of the left lateral recumbent (LLR) position, although its effectiveness has been questioned. This study used transesophageal echocardiography to evaluate the effect of body repositioning on intracardiac air and acute cardiac dimension changes. METHODS: Eighteen anesthetized dogs in the supine position received a venous air injection of 2.5 ml/kg at a rate of 5 ml/ s. After 1 min the dogs were repositioned into either the LLR, LLR 10 degrees head down (LLR-10 degrees), right lateral recumbence, or remained in the supine position. RESULTS: Repositioning after VAE resulted in relocation of intracardiac air to nondependent areas of the right heart. Peak right ventricular (RV) diameter increase and mean arterial pressure decrease were greater in the repositioned animals compared with those in the supine position (P < 0.05). Right ventricular diameter and mean arterial pressure showed an inverse correlation (r = 0.81). Peak left atrial diameter decrease was greater in the LLR and LLR-10 degrees positions compared with the supine position (P < 0.05). Repositioning did not influence peak pulmonary artery pressure increase, and no correlation was found between RV diameter and pulmonary artery pressure. All animals showed electrocardiogram and echocardiographic changes reconcilable with myocardial ischemia. CONCLUSIONS: In dogs, body repositioning after VAE provided no benefit in hemodynamic performance or cardiac dimension changes, although relocation of intracardiac air was demonstrated. Right ventricular air did not appear to result in significant RV outflow obstruction, as pulmonary artery pressure increased uniformly in all groups and was not influenced by the relocation of intracardiac air. The combination of increased RV afterload and arterial hypotension, possibly with subsequent RV ischemia rather than RV outflow obstruction by an airlock appeared to be the primary mechanism for cardiac dysfunction after VAE.

NASA Discipline Environmental Health↗

Modeling the effects of exercise during 100% oxygen prebreathe on the risk of hypobaric decompression sickness

BACKGROUND: Several previous studies indicated that exercise during prebreathe with 100% O2 decreased the incidence of hypobaric decompression sickness (DCS). We report a meta-analysis of these investigations combined with a new study in our laboratory to develop a statistical model as a predictive tool for DCS. HYPOTHESIS: Exercise during prebreathe increases N2 elimination in a theoretical 360-min half-time compartment decreasing the incidence of DCS. METHODS: A dose-response probability tissue ratio (TR) model with 95% confidence limits was created for two groups, prebreathe with exercise (n = 113) and resting prebreathe (n = 113), using nonlinear regression analysis with maximum likelihood optimization. RESULTS: The model predicted that prebreathe exercise would reduce the residual N2 in a 360-min half-time compartment to a level analogous to that in a 180-min compartment. This finding supported the hypothesis. The incidence of DCS for the exercise prebreathe group was significantly decreased (Chi-Square = 17.1, p < 0.0001) from the resting prebreathe group. CONCLUSIONS: The results suggested that exercise during prebreathe increases tissue perfusion and N2 elimination approximately 2-fold and markedly lowers the risk of DCS. Based on the model, the prebreathe duration may be reduced from 240 min to a predicted 91 min for the protocol in our study, but this remains to be verified. The model provides a useful planning tool to develop and test appropriate prebreathe exercise protocols and to predict DCS risks for astronauts.

NASA Program Environmental Health↗