SEARCH · Search NASA
Results for “NATURAL CONVECTION”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Effect of nonuniform isoflux heating on natural convection heat transfer in a prismatic modular reactor
Not provided.
Effect of helium pressure on natural convection heat transfer in a prismatic dual-channel circulation loop
Not Available
Benchmark Simulation of the Natural Convection Shutdown Heat Removal Test Facility Using SAM
Natural convection systems are a promising method to passively remove heat from reactor cavities during loss of forced flow accident scenarios. In this work at Argonne National Laboratory (ANL), a highly instrumented Natural Convection Shutdown Heat Removal Test Facility (NSTF) was used to demonstrate the effectiveness of air-cooled natural convection systems. In previous work, RELAP5-3D simulations were performed on this facility with favorable comparisons to experiment for mass flow rate, pressure drop, air temperature increase, and air velocity. Both experimental and simulation efforts with this facility present a useful opportunity to perform a benchmark study with the System Analysis Module (SAM). SAM is an advanced thermal-hydraulic system code currently in development at ANL for advanced non-light water reactor safety analysis.
Oscillatory and nonoscillatory behavior of a simple model for cool flames, Sal'nikov's reaction, P{yields}A {yields}B, occurring in a spherical batch reactor with varying intensities of natural convection
When cool flames, or indeed any exothermic chemical reaction, occur in a fluid inside an unstirred vessel, the heat from the reaction often induces temperature gradients and consequently motion, i.e., natural convection. The intensity of the resulting flow is governed by the Rayleigh number (Ra). This work simulates numerically the behavior of Sal'nikov's reaction, P{yields} A{yields}B, under the influence of natural convection in an unstirred spherical reactor. This reaction is the simplest to exhibit the thermokinetic oscillations characterizing cool flames. The behavior of this system can be represented on a three-dimensional regime diagram, whose axes are ratios of the characteristic timescales ({tau}) for chemical reaction, diffusion (of both heat and mass), and natural convection. Previous work has identified a region of oscillations on this diagram in the purely diffusive limit, when Ra=0. This work extends this analysis to the general 3D space, where diffusion and natural convection are both important. A region in which oscillations are observed has been found for fixed values of the first-order rate constants for Sal'nikov's reaction. There is a distinct change in the shape of the region of oscillations around the critical value of Ra{proportional_to}500, when natural convection becomes important. When diffusion dominates transport (Ra<500), the boundaries between oscillatory and nonoscillatory solutions are largely independent of the ratio of timescales {tau}{sub step}2/{tau}{sub convection} and agree well with the values found previously in the purely diffusive limit. When natural convection is important (Ra>500), the oscillations occur over a wider range of parameters than is the case for a diffusive system. The presence of natural convection also leads to various, more complex behaviors than are seen in the diffusive or well-mixed limits. A region in the regime diagram was found where the oscillations in temperature and the concentration of A have small amplitudes and a frequency that is quite different from those generated in a well-mixed system. It is possible that these oscillations are caused by natural convection, i.e., are not thermokinetic oscillations produced by the chemical reaction. It was also found that sometimes the oscillations in the temperature and the concentration of A are in phase; more generally they are in anti-phase. The evolution of nonoscillatory behavior with relatively small increases in temperature was found to be always fairly similar, regardless of the intensity of natural convection. The shape of the temperature profile along the vertical axis of the reactor did, however, change with the intensity of natural convection. Finally, the nonoscillatory solutions with a large rise in temperature in the presence of natural convection were found to be very much like those seen in the purely diffusive limit for small times, due to the relatively long induction time ({proportional_to}3.5 s in a vessel with diameter 0.1 m) for the onset of natural convection. (author)
The Phenix ultimate natural convection test
The French sodium cooled fast reactor Phenix was shut down in 2009 after 35 years of operation. Before decommissioning, a final set of tests were performed by the CEA during 9 months. Several topics were involved such as thermal hydraulics, core physics and fuel behaviour. Among these ultimate experiments, two thermal hydraulic tests were performed: an asymmetrical test consisting in a trip of one secondary pump and a natural convection test in the primary circuit. Recognizing the unique opportunity offered by these Phenix ultimate tests, IAEA decided in 2007 to launch a Coordinated Research Project (CRP) devoted to benchmarking analyses with system codes on the Phenix natural convection test. One objective of the natural convection test in Phenix reactor is the assessment of the CATHARE system code for safety studies on future and advanced sodium cooled fast reactors. The aim of this paper is to describe this test, which was performed on June 22-23, 2009, and the associated benchmark specifications for the CRP work. The paper reminds briefly the Phenix reactor with the main physical parameters and the instrumentation used during the natural convection test. After that, the test scenario is described: - initial state at a power of 120 MWth, - test beginning resulting from a manual dry out of the two steam generators, - manual scram, - manual trip on the three primary pumps without back-up by pony motors, - setting and development of natural convection in the primary circuit, in a first phase without significant heat sink in the secondary circuits and in a second phase with significant heat sink in the secondary circuits, by opening the casing of steam generators to create an efficient heat sink, by air natural circulation in the steam generators casing. The benchmark case ends after this second phase, which corresponds to the experimental test duration of nearly 7 hours. The paper presents also the benchmark specifications data supplied by the CEA to all participants of this CRP in order to perform calculations (core, primary circuit, primary pumps, IHX, shutdown system, operating parameters, test scenario and real test conditions). Finally, main test results and analyses are presented including the evolution of the core and of the heat exchangers inlet and outlet temperatures, and some local temperature measurements. The natural convection has been easily set up in the pool type reactor Phenix with different boundary conditions at the secondary side, with or without heat sink. The data obtained during this unique test represent some very useful and precious results for the development of SFR in a wide range of thematic such as numerical methods dedicated to thermal-hydraulics safety analyses (system codes, CFD codes and coupling system and CFD codes) and instrumentation. (authors)
Experimental study of natural convective heat transfer in a vertical hexagonal sub channel
The development of new practices in nuclear reactor safety aspects and optimization of recent nuclear reactors, including the APWR and the PHWR reactors, needs a knowledge on natural convective heat transfer within sub-channels formed among several nuclear fuel rods or heat exchanger tubes. Unfortunately, the currently available empirical correlation equations for such heat transfer modes are limited and researches on convective heat transfer within a bundle of vertical cylinders (especially within the natural convection modes) are scarcely done. Although boundary layers around the heat exchanger cylinders or fuel rods may be dominated by their entry regions, most of available convection correlation equations are for fully developed boundary layers. Recently, an experimental study on natural convective heat transfer in a subchannel formed by several heated parallel cylinders that arranged in a hexagonal configuration has been being done. The study seeks for a new convection correlation for the natural convective heat transfer in the sub-channel formed among the hexagonal vertical cylinders. A new convective heat transfer correlation equation has been obtained from the study and compared to several similar equations in literatures.
CATHARE calculations of Phenix ultimate natural convection test
The Phenix Sodium cooled Fast Reactor (SFR) started operation in 1973 and it was stopped in 2009. Before the reactor was definitively shutdown, in order to collect experimental data for code assessments in the frame of Generation IV an intensive program of ultimate tests was set up. Among these ultimate experiments, two thermal hydraulic tests were performed: an asymmetrical test consisting in a trip on one secondary pump and a natural convection test in the primary circuit. The natural convection test has been used for an international benchmark on system codes in the frame of the IAEA. The CATHARE code - initially developed for water cooled reactors and now extended for safety analyses for other kinds of reactors, including Sodium Fast Reactor - was used by CEA for this benchmark. The paper reminds briefly the Phenix reactor with the main physical parameters and the instrumentation used during the natural convection test. Main test results are also briefly reminded including the evolution of the core and the heat exchangers inlet and outlet temperatures, and some local temperature measurements. The main developments to perform CATHARE SFR computations and the strategy of system code assessment are presented. Then the CATHARE modelling of Phenix reactor is depicted and the various assumptions are pointed out. CATHARE encountered no problem to predict the initial nominal state. Afterwards, the whole transient scenario is calculated and CATHARE calculations are compared to the Phenix measurements. The global trend is rather well predicted by the CATHARE code. Nevertheless, due to complex flow phenomena occurring in large plena and components, the system code encountered physical limitations, leading to remaining discrepancies between code prediction and plant data. Various sensitivity calculations are presented and they bring partial answers. Additional analyses are in progress to understand more deeply the complex 3D phenomena involved during the different phases of the natural convection test. Additional work for coupling CATHARE system code and TRIO-U CFD code is in progress and will bring useful information to better understand the physical phenomena involved during the natural convection test and to improve system modeling for future SFR safety analysis. (authors)
Natural convection in metal foam strips with internal heat generation
Natural convection heat transfer in metal foam strips, with internal heat generation, was investigated experimentally for two porosities. An estimate of the non-equilibrium temperature distribution was done by image processing of the thermal maps on both the surface and the inner region of the metal foam specimen. It was shown that heat transfer at natural convection in the strip of metal foam was increased drastically (up to 18-20 times for metal foam of 20 ppi) relative to the flat plate of the same overall dimensions. The heat transfer from ligaments of metal foam was estimated. (author)
Design Report for the ½ Scale Air-Cooled RCCS Tests in the Natural convection Shutdown heat removal Test Facility (NSTF)
The Natural convection Shutdown heat removal Test Facility (NSTF) is a large scale thermal hydraulics test facility that has been built at Argonne National Laboratory (ANL). The facility was constructed in order to carry out highly instrumented experiments that can be used to validate the performance of passive safety systems for advanced reactor designs. The facility has principally been designed for testing of Reactor Cavity Cooling System (RCCS) concepts that rely on natural convection cooling for either air or water-based systems. Standing 25-m in height, the facility is able to supply up to 220 kW at 21 kW/m 2 to accurately simulate the heat fluxes at the walls of a reactor pressure vessel. A suite of nearly 400 data acquisition channels, including a sophisticated fiber optic system for high density temperature measurements, guides test operations and provides data to support scaling analysis and modeling efforts. Measurements of system mass flow rate, air and surface temperatures, heat flux, humidity, and pressure differentials, among others; are part of this total generated data set. The following report provides an introduction to the top level-objectives of the program related to passively safe decay heat removal, a detailed description of the engineering specifications, design features, and dimensions of the test facility at Argonne. Specifications of the sensors and their placement on the test facility will be provided, along with a complete channel listing of the data acquisition system.
Radiation effects on bifurcation and dual solutions in transient natural convection in a horizontal annulus
Transitions and bifurcations of transient natural convection in a horizontal annulus with radiatively participating medium are numerically investigated using the coupled lattice Boltzmann and direct collocation meshless (LB-DCM) method. As a hybrid approach based on a common multi-scale Boltzmann-type model, the LB-DCM scheme is easy to implement and has an excellent flexibility in dealing with the irregular geometries. Separate particle distribution functions in the LBM are used to calculate the density field, the velocity field and the thermal field. In the radiatively participating medium, the contribution of thermal radiation to natural convection must be taken into account, and it is considered as a radiative term in the energy equation that is solved by the meshless method with moving least-squares (MLS) approximation. The occurrence of various instabilities and bifurcative phenomena is analyzed for different Rayleigh number Ra and Prandtl number Pr with and without radiation. Then, bifurcation diagrams and dual solutions are presented for relevant radiative parameters, such as convection-radiation parameter Rc and optical thickness τ. Numerical results show that the presence of volumetric radiation changes the static temperature gradient of the fluid, and generally results in an increase in the flow critical value. Besides, the existence and development of dual solutions of transient convection in the presence of radiation are greatly affected by radiative parameters. Finally, the advantage of LB-DCM combination is discussed, and the potential benefits of applying the LB-DCM method to multi-field coupling problems are demonstrated.
Study of plasma natural convection induced by electron beam in atmosphere [ ]
Using high-energy electron beams to ionize air is an effective way to produce a large-size plasma in the atmosphere. In particular, with a steady-state high power generator, some unique phenomena can be achieved, including natural convection of the plasma. The characteristics of this convection are studied both experimentally and numerically. The results show that an asymmetrical temperature field develops with magnitudes that vary from 295 K to 389 K at a pressure of 100 Torr. Natural convection is greatly enhanced under 760 Torr. Nevertheless, plasma transport is negligible in this convection flow field and only the plasma core tends to move upward. Parameter analysis is performed to discern influencing factors on this phenomenon. The beam current, reflecting the Rayleigh number Ra effect, correlates with convection intensity, which indicates that energy deposition is the underlying key factor in determining such convections. Finally, natural convection is concluded to be an intrinsic property of the electron beam when focused into dense air, and can be achieved by carefully adjusting equipment operations parameters.
RANS simulation of natural convection in an enclosure with curved surface heating from below
Prediction accuracy of natural convection is strongly dependent on the choice of turbulence model. In this paper, different turbulence models as well as turbulent heat flux models are employed to predict the natural convection in an enclosure with curved surface heating from below and investigate their performance. Based on the simulation results, it is found that k-ε model which is well known to overestimate the production of kinetic energy provides a higher prediction of Nusselt number while k-ε-ζ-f model provides a relatively smaller estimation. A systematic CFD simulation is carried out for Rayleigh numbers in the range 10{sup 9} to 10{sup 11}, with which the influence from aspect ratio is also investigated. The effect of Rayleigh number on heat transfer is found to be significant and the dependency of Nusselt number (Nu) is obtained as a function of Rayleigh number (Ra). The influence from the aspect ratio of the simulation domain is found to be dependent on the choice of turbulence model. For k-ε model, Nu increases as aspect ratio increases, while an opposite dependency is observed when k-ε-ζ-f model is used. For this discrepancy, arguments are provided based on the streamlines and the profiles of Nu over the heating surface. (authors)
Improved natural convection heat transfer correlations for reactor cavity cooling systems of high-temperature gas-cooled reactors: From computational fluid dynamics to Pronghorn
The Reactor Cavity Cooling System (RCCS) is a common reactor safety system in High Temperature Gas Cooled Reactors (HTGR) that removes heat from the Reactor Pressure Vessel (RPV) by radiation ($\sim 80\%$) and natural convection ($\sim 20\%$). For simulation of accident scenarios of HTGRs, intermediate fidelity and system codes models must be employed for limiting the models' execution time. While accurate quantification of the radiative heat transfer is available in these models, quantification of natural convection must rely on correlations of questionable accuracy for the Nusselt number. Commonly used correlations are based in experiments performed at low Rayleigh numbers and/or using isothermal walls in simplified geometries. Here, this work improves on the accuracy of natural convection heat transfer correlations in support for HTGR designs. These correlations include both local and average Nusselt numbers as a function of the global Rayleigh number, the local Rayleigh number, and the temperature profile at the hot wall of the RCCS. In the absence of dedicated experiments and the difficulty of performing high-fidelity simulations at realistic Rayleigh numbers, the data to fit the correlations are generated with Computational Fluid Dynamics (CFD) using Reynolds Averaged Navier-Stokes (RANS) models. First, a careful selection of the RANS turbulence model is performed by comparing the results obtained with different RANS turbulence models against high fidelity simulations of natural convection at $Ra \ 1 \times 10^{11}$ in a rectangular cavity. Next, the selected model is used to perform simulations of an HTGR cavity at different high Rayleigh numbers $\in [6.1 \times 10^{11},2.9 \times 10^{13}]$ to encompass several HTGR designs, assuming an isothermal RPV wall. The results obtained are used to fit a correlation for the average and space-varying Nusselt number as a function of the global and local Rayleigh numbers via a sparsity-promoting least-squares method. The selected RANS model is then used to perform simulations of a PBMR 400 HTGR cavity with the temperature profiles at the RPV wall obtained during a PLOFC transient. We use the results obtained to fit a temperature-dependent correction to the space-varying Nusselt number with the sparsity-promoting least-squares method. The results obtained in this work, enable system-level codes, such as Pronghorn, to perform higher-fidelity simulations of the heat exchange process in the RCCS while still maintaining a low computational cost.
An improved model for natural convection heat loss from modified cavity receiver of solar dish concentrator
A 2-D model has been proposed to investigate the approximate estimation of the natural convection heat loss from modified cavity receiver of without insulation (WOI) and with insulation (WI) at the bottom of the aperture plane in our previous article. In this paper, a 3-D numerical model is presented to investigate the accurate estimation of natural convection heat loss from modified cavity receiver (WOI) of fuzzy focal solar dish concentrator. A comparison of 2-D and 3-D natural convection heat loss from a modified cavity receiver is carried out. A parametric study is carried out to develop separate Nusselt number correlations for 2-D and 3-D geometries of modified cavity receiver for estimation of convective heat loss from the receiver. The results show that the 2-D and 3-D are comparable only at higher angle of inclinations (60 {<=} {beta} {<=} 90 ) of the receiver. The present 3-D numerical model is compared with other well known cavity receiver models. The 3-D model can be used for accurate estimation of heat losses from solar dish collector, when compared with other well known models. (author)
A stabilized stochastic finite element second-order projection method for modeling natural convection in random porous media
We consider natural convection in flow saturated porous media with random porosity. The porosity is treated as a random field and a stochastic finite element method is developed. The stochastic projection method is considered for the solution of the high-dimensional stochastic Navier-Stokes equations since it leads to the uncoupling of the velocity and pressure degrees of freedom. Because of the porosity dependence of the pressure gradient term in the governing flow equations, one cannot use the first-order projection method. A stabilized stochastic finite element second-order projection method is presented based on a pressure gradient projection. A two-dimensional stochastic problem with moderate and large variation in the random porosity field is examined and the results are compared with Monte-Carlo and sparse grid (Smolyak) collocation approaches. Excellent agreement between these results indicates the effectiveness and accuracy of the proposed methodology.
Natural convection heat transfer from two horizontal cylinders
Natural convection heat transfer from a single horizontal cylinder and a pair of vertically aligned horizontal cylinders is investigated. Surface heat transfer distributions around the circumference of the cylinders are presented for Rayleigh numbers of 2 x 10{sup 6}, 4 x 10{sup 6} and 6 x 10{sup 6} and a range of cylinder spacings of 1.5, 2 and 3 diameters. With a cylinder pairing the lower cylinder is unaffected by the presence of the second cylinder; the same is true of the upper cylinder if the lower one is not heated. However, when both cylinders are heated it has been found that a plume rising from the heated lower cylinder interacts with the upper cylinder and significantly affects the surface heat transfer distribution. Spectral analysis of surface heat transfer signals has established the influence of the plume oscillations on the heat transfer. Thus, when the plume from the lower cylinder oscillates out of phase with the flow around the upper cylinder it increases the mixing and results in enhanced heat transfer. (author)
Calculation of natural convection test at Phenix using the NETFLOW++ code
The present paper describes modeling and analyses of a natural convection of the pool-type fast breeder reactor Phenix. The natural convection test was carried out as one of the End of Life Tests of the Phenix. Objective of the present study is to assess the applicability of the NETFLOW++ code which has been verified thus far using various water facilities and validated using the plant data of the loop-type FBR 'Monju' and the loop-type experimental fast reactor 'Joyo'. The Phenix primary heat transport system is modeled based on the benchmark documents available from IAEA. The calculational model consists of only the primary heat transport system with boundary conditions on the secondary-side of IHX. The coolant temperature at the primary pump inlet, the primary coolant temperature at the IHX inlet and outlet, the secondary coolant temperatures and other parameters are calculated by the code where the heat transfer between the hot and cold pools is explicitly taken into account. A model including the secondary and tertiary systems was prepared, and the calculated results also agree well with the measured data in general. (authors)