Search NASA⌕ Search

SEARCH · Search NASA

Results for “NCERC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Nuclear Criticality Experimental Research Center (NCERC) Overview

The mission of the National Criticality Experiments Research Center (NCERC) at the Device Assembly Facility (DAF) is to conduct experiments and training with critical assemblies and fissionable material at or near criticality in order to explore reactivity phenomena, and to operate the assemblies in the regions from subcritical through delayed critical. One critical assembly, Godiva-IV, is designed to operate above prompt critical. The Nuclear Criticality Experimental Research Center (NCERC) is our nation’s only general-purpose critical experiments facility and is only one of a few that remain operational throughout the world. This presentation discusses the history of NCERC, the general activities that makeup work at NCERC, and the various government programs and missions that NCERC supports. Recent activities at NCERC will be reviewed, with a focus on demonstrating how NCERC meets national security mission goals using engineering fundamentals. In particular, there will be a focus on engineering theory and design and applications of engineering fundamentals at NCERC. NCERC activities that relate to engineering education will also be examined.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

National Criticality Experiments Research Center (NCERC) - capabilities and recent measurements

The National Criticality Experiments Research Center (NCERC) located at the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS) and operated by Los Alamos National Laboratory (LANL) is home to four critical assemblies which are used to support of range of missions, including nuclear criticality safety and nuclear nonproliferation. Additionally, subcritical systems can also be assembled at NCERC. NCERC is providing critical and subcritical experiments valuable to the nuclear data community and experiments performed at NCERC are often published as benchmarks in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. This manuscript will give a broad overview of recent experiments performed at NCERC, upcoming experiments, and why integral measurements are important and useful to the nuclear data community. The four critical assemblies are GODIVA IV, FLATTOP, COMET, and PLANET. GODIVA IV is a cylindrical metal fast burst reactor, the fourth in the GODIVA series that dates back to the 1950’s. FLATTOP is an highly enriched uranium (HEU) or Pu core reflected by natural uranium. COMET and PLANET are vertical lift assemblies, where one half of the reactor can be lifted to the upper half of the reactor to create a critical system. Some recent experiments include various critical intermediate energy assemblies with lead, and subcritical measurements of plutonium reflected by copper, tungsten, and nickel. Work is also underway to make a better measurement of the critical mass of neptunium, using a neptunium sphere surrounded by nickel shells. Additionally, measurements will be performed next year with HEU shells from Rocky Flats. These HEU shells will be stacked together to make larger systems, allowing for a large range of criticality (from subcritical to delayed critical). Other upcoming measurements include an HEU critical assembly sensitive to intermediate energy neutrons.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A New Era of Nuclear Criticality Experiments: The First 10 Years of Comet Operations at NCERC

Comet is a general-purpose, heavy-duty, vertical-lift assembly designed for flexibility in conducting a variety of critical experiments. It is currently located at the National Criticality Experiments Research Center (NCERC) in Nevada. In the past, Comet resided at Technical Area-18 in Los Alamos, New Mexico, as part of the Los Alamos Critical Experiments Facility (LACEF). The Comet assembly was relocated to NCERC in 2008 and became fully operational in June of 2011. The first critical experiment performed on Comet at NCERC was a verification of one of the previous configurations of the Zeus experiment series. Over the next 10 years, many additional experiments followed including other Zeus configurations as well as completely new designs. This paper discusses the Comet vertical-lift assembly, the transition from LACEF to NCERC, and a selection of experiments that have been performed on Comet during its first 10 years of operation at NCERC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NCERC 2024 Highlights

The National Nuclear Security Administration (NNSA) is entrusted with ensuring the safety, security, and reliability of the nation’s nuclear weapons stockpile while advancing programs aimed at reducing global nuclear proliferation. These critical mission objectives are achieved through the expertise of a highly skilled team of professionals. The operations at the National Criticality Experiments Research Center (NCERC) play a vital role in developing and enhancing knowledge and expertise in advanced nuclear technologies. NCERC supports a wide range of mission areas, including nuclear criticality safety, nuclear emergency response, and nuclear nonproliferation, safeguards, and arms control. It also provides support to the Department of Homeland Security, advances stockpile stewardship science, and delivers scientific expertise to other government agencies, such as NASA and the Defense Threat Reduction Agency. NCERC conducts experiments utilizing diverse nuclear materials, from small neutron-emitting sources for testing radiation detection equipment to larger quantities of uranium and plutonium for criticality experiments. A cornerstone of NCERC's mission portfolio includes the operation of four critical mass assembly machines—Planet, Comet, Flattop, and Godiva-IV—which are instrumental in advancing nuclear science and ensuring the nation’s nuclear security objectives.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A New Era of Nuclear Criticality Experiments: The First 10 Years of Godiva IV Operations at NCERC

The work presented in this paper focuses on the first 10 years (2011–2020) of Godiva IV operations at the National Criticality Experiments Research Center (NCERC). Godiva IV is a fast burst critical assembly constructed of approximately 65 kg of highly enriched uranium fuel alloyed with 1.5% molybdenum for strength. Godiva is one of the last such critical assemblies in the United States and can be used for studies of super-prompt-critical behavior as well as irradiations and demonstrations. An overview of the startup of Godiva IV at NCERC is given followed by a summary of the experiments performed utilizing Godiva IV over the first 10 years of operation at NCERC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Era of Nuclear Criticality Experiments: The First 10 Years of Planet Operations at NCERC

Planet is a vertical-lift assembly machine currently located at the National Criticality Experiments Research Center (NCERC) at the Nevada National Security Site. In the past, Planet resided at Technical Area-18 in Los Alamos, New Mexico, as part of the Los Alamos Critical Experiments Facility (LACEF). Following the de-inventorying of LACEF, the Planet assembly was relocated to NCERC in 2008 and became fully operational in June of 2011. The Class Foils experiment, which involves stacking highly enriched uranium foils to obtain a critical configuration, was the first critical experiment performed on Planet. As a major component of the Nuclear Criticality Safety Class taught for the U.S. Department of Energy (DOE) Nuclear Criticality Safety Program, the Class Foils experiment allows personnel from all over the DOE complex to handle nuclear material and to complete the approach to critical safely and successfully. This paper describes the Planet vertical assembly and recent engineering upgrade and a selection of the experiments that have been performed on Planet since its transition to NCERC 10 years ago.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Special Issue of Nuclear Science and Engineering celebrates the Tenth Anniversary of Operations at NCERC

The National Criticality Experiments Research Center (NCERC) is a general-purpose critical experiment facility, the only one in the US and one a few that remain operational throughout the world. NCERC is located at the Nevada National Security Site (NNSS), formerly known as the Nevada Test Site, and is operated by Los Alamos National Laboratory (LANL). This year, NCERC celebrated its 10th year of operation. To commemorate the first ten years of operations and experiments, a special issue of Nuclear Science and Engineering was prepared with papers focusing on each of the four critical assemblies and one on Radiation Test Object (RTO) measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Awe Bonner sphere measurements of the neutron leakage spectrum from the GODIVIA-IV critical assembly at NCERC - 14413

The US National Criticality Experiments Research Centre (NCERC) is home to several critical assembly machines that were relocated from Los Alamos National Laboratory in the last decade. The centre is sponsored by the Department of Energy's Nuclear Criticality Safety Program (NCSP), which has the mission to ensure the safe handling of fissile materials from a criticality perspective. Under the auspices of the NCSP, Lawrence Livermore National Laboratory (LLNL) is planning to host an international inter-comparison of nuclear accident dosimetry (NAD) using the Godiva-IV assembly at NCERC. The inter-comparison is motivated by a decline in the frequency of performance testing of NADs (both in the US, the UK and France) and the desire to modernize and harmonize dosimetry systems. A pre-requisite for the inter-comparison is the characterisation of the neutron and gamma-ray leakage spectra associated with the Godiva-IV assembly at NCERC. AWE provided its Bonner-sphere spectrometry capability to LLNL for two experimental campaigns, in November 2013 and May 2014, to measure the neutron leakage spectrum of the assembly in both a sub-critical 'steady-state' and a super-prompt-critical 'burst'. Nine points, at distances from 2 to 4 meters from the machine were measured with the Bonner-sphere spectrometer using both an active He-3 detector and a passive technique employing gold foils. This paper presents the spectra unfolded from the data and integral dose values, and compares these to previously published data. The limitations of the work and future plans are also discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

NCERC-CL TREAT Free Field Characterization Foil Reaction Rate Results

This report summarizes the analysis and preliminary MCNP reaction rate modeling of free field characterization measurements performed in the Transient Reaction Test Facility (TREAT) at Idaho National Laboratory (INL) between 12/18/2023 and 2/22/2024. A series of seven irradiations were performed using the Big-BUSTER (Broad Use Specimen Transient Experiment Rig) core configuration. Foil sets including 19.5% LEU-Zr alloy wire, S, Au, Fe, Ni, Co, Ti, and Zr were deployed in each irradiation. Identical foil sets were supplied to Los Alamos National Laboratory (LANL), Lawrence Livermore National Laboratory (LLNL), and INL. All foils were supplied by INL. Additional details on the experiment can be found in [2]. The foil sets were shipped to the National Criticality Experiments Research Center Counting Laboratory (NCERC-CL) branch at LANL (NCERC-CL NISC) and were received on 3/25/2024. Additional details on receipt and counting are reported in [3]. All reactor dosimetry measurements were performed in adherence to the ASTM standards applicable to reactor dosimetry. Measured reaction rates from Au, Co, Fe, Ni, and Ti are reported. Select reaction rate ratios and simulated reaction rates and ratios are discussed. Reaction rates for all measured reaction products were modeled with MCNP 6.3.1 and a TREAT input deck supplied by Edward Lum. Neutron emission estimates calculated using the measured and simulated reaction rates show excellent agreement between the three fast-threshold n-p reactions with the percent differences being < 9% between the three reactions. The capture reactions had poorer, but still reasonable, agreement with < 20% percent differences between the neutron emission estimates of the three capture reactions. The percent difference between the fast-threshold and capture reactions is ∼ 100% for each reaction. This supports the TREAT model is not accurately modeling the neutron spectrum and additional measurements are required to characterize TREAT and match measurements to simulation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of NCERC Critical Experiments with ENDF/B Nuclear Data Libraries

Nuclear data (ND) libraries are the backbone of the nuclear industry, as they are the collections of tabulated probabilities that define sub-atomic particle interactions with matter. In the areas of criticality safety and experiments, no evaluated nuclear data files (ENDF) are more important than those containing neutron cross section data. It is upon these files, and accompanying radiation transport codes, that practitioners are enabled to safely design both subcritical and critical systems. Likewise, in a symbiotic fashion, it is the same critical assemblies which are used primarily to validate that the cross sections are correct. The ENDF/B library, the United States’ national library maintained by the National Nuclear Data Center (NNDC) at Brookhaven National Laboratory (BNL), is soon releasing a new version, ENDF/B-VIII.1. Prior to the official release, several beta versions of the library were prepared and tested in simulation suites. The work presented here are results comparing the newest ENDF/B beta release (ENDF/B-VIII.1b3) and ENDF/B-VIII.0 with recent experiments done at the National Criticality Experiments Research Center (NCERC) as well as correlated experiments from the Los Alamos Critical Experiments Facility (LACEF). These NCERC and LACEF experiments were performed in part to provide validation for various cross sections that were identified as insufficient in the ENDF/B-VIII.0. In particular, lead, copper, fluorine, and chlorine, as well as the major actinides, were targeted from the last decade of critical experiments.

97 MATHEMATICS AND COMPUTING↗

A New Era of Nuclear Criticality Experiments: The First 10 Years of Flattop Operations at NCERC

The Flattop critical assembly was built and operated from 1958 through 2004 at the Pajarito Site (Technical Area-18), home to the Los Alamos Critical Experiments Facility. Flattop was disassembled in 2005 and refurbished over the course of 3 years. In 2008, Flattop was installed in the National Criticality Experiments Research Center (NCERC) located in the Device Assembly Facility at the Nevada National Security Site. Startup of Flattop with a uranium core occurred in 2011. This paper details the first 10 years of Flattop operations at NCERC (2011–present).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NCERC Capabilities

National Criticality Experiments Research Center (NCERC), located at the Nevada Nuclear Security Site (NNSS) operated by Los Alamos National Laboratory, is our nation’s only general-purpose critical experiments facility and is one of only a few that remain operational throughout the world. NCERC Directly Contributes to Important National and International Missions and is Making Investments in Pipeline and the Facility for enduring capability and expanding missions. More detailed capabilities are described.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NCERC Capabilities [Slides]

NCERC is our nation’s only generalpurpose critical experiments facility and is one of only a few that remain operational throughout the world. The mission of the National Criticality Experiments Research Center (NCERC) is to conduct experiments and training with critical assemblies and fissionable material at or near criticality in order to explore reactivity phenomena, and to operate the assemblies in the regions from subcritical through delayed critical. One critical assembly, Godiva-IV, is designed to operate above prompt critical.

61 RADIATION PROTECTION AND DOSIMETRY↗

National Criticality Experiments Research Center (NCERC) Recent Measurements and Capabilities [Slides]

The National Criticality Experiments Research Center (NCERC) is operated by Los Alamos National Laboratory and has four critical assemblies (Including Godiva, which can be operated above prompt critical). Subcritical measurements are also performed. NCERC is the only general-purpose critical experiments facility in the US and is one of only a few that remain operational throughout the world.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

National Criticality Experiments Research Center (NCERC) [Slides]

The National Criticality Experiments Research Center (NCERC) is a general-purpose critical assembly facility located within the Device Assembly Facility at the Nevada National Security Site. The NCERC is operated by Los Alamos National Laboratory.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Neutron Spectrum Measurements from Irradiations at NCERC

Several irradiations have been conducted on assemblies (COMET/ZEUS and Flattop) at the National Criticality Experiments Research Center (NCERC) located at the Nevada National Security Site (NNSS). Configurations of the assemblies and irradiated materials changed between experiments. Different metallic foils were analyzed using the radioactivation method by gamma-ray spectrometry to understand/characterize the neutron spectra. Results of MCNP calculations are shown. It was concluded that MCNP simulated spectra agree with experimental measurements, with the caveats that some data are limited by statistics at low-energies and some activation foils have low activities.

42 ENGINEERING↗