Search NASA⌕ Search

SEARCH · Search NASA

Results for “NCSP Critical Assemblies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

NCSP Nuclear Data Program [Slides]

This talk covers wide-ranging information on the Nuclear Criticality Safety Program (NCSP) Data Program. The Lecture includes slides on the history and mission of the NCSP along with charts and graphs on budgets from 2005 onwards. This lecture additionally mentions NCSP critical assemblies, differential experiments, and data measurements and evaluation work. The talk concludes with a gaze into NCSP benefits and successes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast neutron leakage spectra of the EUCLID experiment

Special nuclear material in sub-critical and critical configurations measured in integral experiments are important for validation and adjustment of nuclear data. Many different evaluations of nuclear data exist, and these different evaluations can provide different values for individual cross sections that vary due to the uncertainties in differential experiments or lack of such data. For integral experiments, differences in these individual cross sections can have compensating errors, which lead to the same answer. One example of this is the Jezebel critical assembly, where k eff of the system is correctly computed by both ENDF/B-VIII.0 and JEFF-3.3, despite having substantially different underlying evaluated values for specific reactions (such as elastic and inelastic cross sections). To reduce compensating errors in nuclear data, the Experiments Underpinned by Computational Learning for Improvements in Nuclear Data (EUCLID) project has utilized machine learning to design a set of sub-critical and critical experiments. These experiments include slab- and cube-like configurations of 239 Pu in the form of the ZPPR plates. Six different responses were measured on a total of thirteen different configurations. One of these responses, the neutron leakage spectrum, was measured using an EJ301D detector. Finally, the results of the neutron leakage spectra show good agreement (within 1–2 σ ) with the expected spectrum from simulations and will be used in the subsequent nuclear data adjustment done by the EUCLID team.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Shielding Benchmarks Using the Godiva IV Assembly

The Nuclear Criticality Safety Program (NCSP) is developing a shielding benchmark using the Godiva IV assembly as a source. Its present status is reviewed herein. Even eight decades into the nuclear era, substantial work remains to develop a database of shielding benchmarks to support future nuclear development. A nuclear simulation is only as good as its supporting data, inputs, and validation basis. Uncertainty in these areas is addressed using conservatism, which adds margin and, occasionally, cost. In many shielding situations, high accuracy is not necessary because additional material is not particularly expensive. After all, 1–2 cm of lead often reduces the gamma ray dose substantially. However, in certain areas, conservatism can add unnecessary cost. These areas include mobile shielding applications such as casks, ships, microreactors, and spacecraft, where weight and, thus, margin is expensive. Although these characteristics are side benefits for NCSP shielding benchmark development, the main driver is enabling more reliable placement of criticality accident alarm systems (CAASs) in nuclear material facilities, such as those dedicated to the production of advanced reactor fuels. CAAS placement relies on more than accurate data and code validation. It also relies on sufficiently accurate materials specifications, geometry specifications, and a well-defined, alarm-producing baseline accident. All these things require tacit knowledge and understanding of the problem being evaluated. Benchmarks can help ensure this understanding.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Final Design for Thermal/Epithermal eXperiments (TEX) with Lithium Absorbers to Provide Validation Benchmarks for Y-12 Electrorefining Facility

One of the main goals of the Thermal/Epithermal eXperiments (TEX) project is to use existing Nuclear Criticality Safety Program (NCSP) assets to create critical experiment plutonium and uranium test beds for materials important to criticality safety that have insufficient benchmark evaluations. The plutonium test bed experiments were completed in 2018 and are published in the 2020 edition of the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The uranium test bed assemblies were completed in 2023 and accepted in the 2024 edition of the ICSBEP Handbook. The Nuclear Criticality Safety (NCS) group at Y-12 National Security Complex has identified programmatic need for validation cases for uranium electrorefining operations at Y-12. The electrorefining operation credits lithium enriched in 6 Li in addition to 35 Cl as absorbers in the design criticality safety evaluation for precluding criticality under upset conditions in the large and geometrically unfavorable electro-refiner. There is, however, inadequate experimental validation for the 6 Li absorbers. As an extension of the TEX uranium test bed, TEX-Cl critical experiments were performed with sodium chloride salt to address the 35 Cl thermal absorption as well as other validation needs at Los Alamos National Laboratory (LANL). These experiments were completed in 2024 and accepted into the 2025 ICSBEP Handbook. To continue the methodology used in TEX-Cl, TEX-Li aims to accomplish the same. The overall design of both experiments was to use commercially available, high purity, salts with polyethylene moderator and HEU plates to configure a critical assembly. Three experiments are planned for TEX-Li using encapsulated lithium carbonate (Li 2 CO 3 ), with natural 6 Li abundance. For all experiments, the highly enriched uranium (HEU) Jemima plates will be used as fissile material. Multiple layers will be stacked together with encapsulated Li 2 CO 3 alternated with polyethylene in standard configurations. Standard stacking was found to be optimal in matching the different sensitivity profiles provided by the Y-12 models. Three configurations are proposed with varying polyethylene moderation and a constant 1/4” absorber thickness. The first uses 11 layers of 5/4” polyethylene, the second uses 9 layers of 3/4” polyethylene, and the third uses 10 layers of 1/2” polyethylene. Calculations showed that some alternative forms of lithium-based materials provided slightly less-optimal sensitivity profiles when compared to lithium carbonate but come with other drawbacks. These alternatives included lithium aluminate (LiAlO 2 ), Aluminum-2050 alloy, Aluminum-8090, Aluminum-2095, lithium hydride (LiH), and lithium fluoride (LiF). Lithium aluminate and aluminum-2050 provided comparable sensitivity profiles when compared to lithium carbonate and can be used instead if lithium carbonate cannot be readily procured. After a broad material study, lithium carbonate outperformed any alternative material with a balance in affordability and workability. The assessment of experimental uncertainties of the non-absorber and absorber components was predicted to be 0.00089 and 0.00093 Δk eff , respectively. The largest uncertainties may be reduced with precision dimensional inspection of the components. Many of the parts and equipment for IER 575 have already been fabricated or procured for previous projects and therefore do not contribute significantly to the overall cost of this experiment. This includes the Jemima plates and Comet critical assembly machine, which are existing NCSP assets, as well as the aluminum platen and polyethylene reflector rings, which were fabricated and authorized for the TEX experiment involving HEU with polyethylene. Lithium carbonate containers will be procured by LANL and will be filled by LLNL. The total material costs for TEX-Li experiments are estimated to be on the order of $\$$47,400. Precision inspection, including dimensional, mass, density, and impurity, is recommended for all components for an estimated cost of $\$$12,000.

35Cl↗

In the Lab with Nuclear Scientists: Critical and Subcritical Assemblies

This presentation talks on the Critical experiments performed on the NCERC machines. Plutonium ( 239 Pu and 240 Pu), Highly Enriched Uranium, Low-Temperature (-40°C). This is all based on a simple design useful for modeling and validation. The design is made to incorporate materials of interest such as Tantalum, hafnium, lithium & more.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nuclear Criticality Safety Pipeline Course - LLNL [Slides]

This presentation details the nuclear criticality safety pipeline course. An educational program from University of California, Berkeley. This course touches on nuclear criticality each fall semester. The curriculum instructs on the fundamentals of criticality safety and provides hands on experience with special nuclear material. This presentation covers lecture topics, project overview, and major criticality safety evaluation projects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Proposed Updates to Pu Evaluation for ENDF/B-VIII.0β 2 [Slides]

This presentation shows current status of in ENDF/B-VIII.0 and ENDF/B-VIII.0β 1 Pu evaluations. With a focus on the Pu thermal solutions (PST) and sanity check on fast metal assemblies (PMF). Pu ENDFβ 1 file in the low-energy region included updates in RRR (up to 2.5 keV), TNC and PFNS. Discussed are improvements over ENDF/B-VIII.0 in the C/E benchmarks (PST 81 cases) with preliminary ν p and cross section covariance generation for the resolved resonance energy range up to 2.25 keV. Highlighted are proposed updates for ENDFβ 2 with an extension of the RRR evaluation up to 5 keV, inclusion of Mosby’s data including proper resolution function (thanks to Marian J.), and a particular focus on η energy dependence from thermal up to 10 eV with the impact of the capture-to-fission ratio at 0.29 eV. This presentation concludes with an updated ν p and cross section covariance generation for the resolved resonance energy range up to 5 keV. And additional validation to test performance at about 2 eV and in the keV region.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Why the US Needs an Enduring Plutonium Critical Assembly

Jezebel (operated from 1954-1977) has been the primary experiment for fast 239 Pu nuclear data validation for the last 70 years. Validation has included not only k eff , but also spectral indicies, Rossi-α, reactivity coefficients, and neutron leakage spectra. While this has been incredibly valuable to the community, there are three major issues. The first issue is that documentation on many of these experiments were lacking, leading to large uncertainties or (even worse) incorrect assumptions. The second issue is that while there have been many advances in research, there is no way to test those new advances today. The last issue is that since the assembly only operated for 23 years (and at time when 30 other critical assemblies were operating at the same facility and nuclear weapons testing was occurring), there were limited opportunities to observe how any system parameters changed as a function of time. Note that this work is not suggesting that a "Jezebel re placement" used for a limited experiment campaign would have great value. A new enduring (100 year target) plutonium (Pu) assembly with simple geometry and low uncertainties, however, would be extremely valuable. Such a capability would have a transformative impact on many research areas including nuclear data validation, analytical methods validation, dosimetry, reactor kinetics, and materials. The need for a new plutonium assembly is not new: it has been in the DOE Nuclear Criticality Safety Program (NCSP) Mission and Vision for over 10 years and was also the top priority established at the 2022 National Criticality Experiments Research Center (NCERC) Futures meeting. This work will discuss how such a new capability would help ensure that the US retains international leadership in plutonium research. Last, a brief overview of Lilith, a project aimed to design a new enduring plutonium assembly for operation at the NCERC will be given.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Overview and Current Progress of the DOE/NNSA Nuclear Criticality Safety Program Training and Education Program

Since 2011, the US Department of Energy/National Nuclear Security Administration (DOE/NNSA) Nuclear Criticality Safety Program (NCSP) has been providing a two-week nuclear criticality safety (NCS) practitioner course to support the training and qualification of new NCS staff. In 2013, an NCS Manager’s course was developed for process supervisors, managers, regulators, and other professionals with NCS-related responsibilities, and, in 2017, an additional course was proposed for Criticality Safety Officers (CSOs). In addition to hands-on training, other NCSP-funded tasks include training on sensitivity/uncertainty methods, NCS resource pipeline tasks, development of NCS guides, maintenance and development of Nuclear Criticality Safety Education Training (NCSET) modules and designing of a new subcritical assembly for hands-on training purposes. This paper provides an overview of the NCSP training and education program. The status of the NCSP hands-on training program will also be provided.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Godiva-IV Dosimetry Exercise 2022 Preliminary Results

Integral Experiment Request (IER) 538 is part of a series of dose characterization and nuclear accident dosimetry (NAD) exercises performed under the Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP). This is the second NAD exercise using the Godiva-IV critical assembly and the third NAD exercise overall. The participating laboratories provided their own dosimeters that were mounted on the Lawrence Livermore National Laboratory (LLNL) BOttle Manikin ABsorption (BOMAB) phantoms and aluminum plates. The BOMABs and plates were placed at two, three, and four meters away from the center of Godiva. Alongside the NADs, there was a LLNL Passive Neutron Spectrometer (PNS), Atomic Weapons Establishment (AWE) PNS, and Y-12 Sphere present to measure the neutron dose from Godiva. Two irradiations were conducted to test the NAD performance from each laboratory and assesses their performance to the DOE-STD-1098-2017 part 515 criteria. Neutron and gamma doses were measured prior to this exercise. This work presents a model for the neutron and gamma dose respectively to serve as the reference value. A code written in C/C++/ROOT was used to fit the measured neutron and gamma dose with the new models. It was assumed that the neutron and gamma doses are proportional to the change in temperature of Godiva after a burst irradiation. Uncertainties for the reference values were calculated using error propagation of the model’s parameters. Preliminary results (within twenty-four hours) and final results were compared for each laboratory. On average of all the participating laboratories, 32% of neutron doses and 78% of gamma doses were outside the DOE standards. One laboratory did not report their dose readings and were not included in this average. There is a bias for a lower neutron dose and a higher gamma dose based on the distribution of results. In comparison with the past Godiva-IV NAD exercise, there is an improvement in neutron dose readings by 20%.

BOttle Manikin ABsorption (BOMAB)↗

Zirconium Scattering Sensitivity in Neutron Transport Calculations of Multiplying Systems [Slides]

This presentation touches on motivation and applications of Zirconium. Performance of evaluated libraries on double and quasi differential experiments is considered. Additionally, the performance of evaluated libraries in select ICSBEP benchmarks is considered. Provided is a detailed look in the performance of evaluated libraries in preliminary benchmark configurations for IER-516: Zirconium Test Assembly (ZTA). Conclusions and recommended experiments to satisfy Zirconium scattering nuclear data needs are presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

TEX-Cl: Integral Experiment Execution of Thermal/Epithermal eXperiments using Highly Enriched Uranium with Polyethylene and Chloride Absorbers

This report documents the experimental configurations and measurements performed for IER-499, TEX with chlorine (TEX-Cl). TEX-Cl is a variant of the TEX-HEU campaign and utilizes highly enriched uranium fuel, high-density polyethylene (HDPE) moderators and reflectors, and interstitial NaCl salt absorbers. These experiments probe the chlorine (from the sodium chloride) absorption cross section in the thermal and intermediate neutron energy regimes, with a small portion in the fast neutron energy regime. Three configurations were selected by maximizing the sensitivity in k eff to the needs of Y-12 for their electrorefining operations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Data Libraries Sensitivity Studies for ORSA Using SCALE

Subcritical assemblies offer valuable training capabilities in nuclear criticality safety (NCS) for individuals handling fissile material. At Oak Ridge National Laboratory(ORNL), the Oak Ridge Subcritical Assembly (ORSA), a new experimental facility, is being established to provide hands-on training for the Nuclear Criticality Safety Program (NCSP).It is essential to accurately determine the neutron multiplication factor (keff) to ensure that ORSA remains subcritical and safe during operations. This study investigated the sensitivity of keff to variations across Evaluated Nuclear Data File (ENDF/B) libraries, consisting of ENDF/B-VII.1, ENDF/B-VIII.0, and ENDF/B-VIII.1. The analysis was conducted using the CSAS6 sequence in the SCALE-6.3 code system. Individual isotopes in the ORSA model were replaced one at a time with ENDF/B-VII.1 as the base library and changing to ENDF/B-VIII.0or ENDF/B-VIII.1. The results demonstrated that the changes in keffof the nuclides associated with the ORSA model were mostly within the uncertainty of the base model (~24 pcm), except for primary nuclides like Uranium-235and H-poly with few other nuclides. The relative delta keff values of Uranium-235 and H-poly, expressed in pcm, were +280 and -212 in ENDF/B-VIII.0 and +332 and -275 in ENDF/B-VIII.1, respectively, which were notable changes in reactivity. These results demonstrated that ORSA was largely insensitive to variations across these nuclear data libraries.

Hong, Evan [North Carolina State University]↗

IER 500: AWE-LLNL Measurement Campaign at DAF [Slides]

Presentation Hosted at Device Assembly Facility (DAF). Joint collaboration by Atomic Weapons Establishment (AWE) and Lawrence Livermore National Laboratory (LLNL). Multiple measurements were recorded through a two-week period with 12 unique objects measured. LLNL deployed Machine learning software program for diagnostic assessments. Current status notes the dedicated DAF team LLNL maintains. Additionally, LLNL is compiling a report on the AWE-LLNL measurements and designing security benchmark experiments. The presentation concludes with future work envisioned.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗