Neutralization efficiency estimation in a neutral beam source based on inductively coupled plasma

This study examined the optimal conditions of neutral beam generation to maintain a high degree of neutralization and focusing during beam energy variation for a neutral beam source based on inductively coupled plasma with a three-grid ion beam acceleration system. The neutral beam energy distribution was estimated by measuring the energy profiles of ions that 'survived' the neutralization after reflection. The energy measurements of the primary and reflected ions showed narrow distribution functions, each with only one peak. At higher beam energies, both the ratio of the ion energy loss to the primary energy and the degree of energy divergence decreased, confirming the precise alignment of the neutral beam. The neutralization efficiency of the neutral beam source with a three-grid acceleration system was found to be affected mainly by the beam angle divergence rather than by the particle translation energy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

200-mm-diameter neutral beam source based on inductively coupled plasma etcher and silicon etching

The authors developed a neutral beam source consisting of a 200-mm-diameter inductively coupled plasma etcher and a graphite neutralization aperture plate based on the design of a neutral beam source that Samukawa et al. [Jpn. J. Appl. Phys., Part 2 40, L779 (2001)] developed. They measured flux and energy of neutral particles, ions, and photons using a silicon wafer with a thermocouple and a Faraday cup and calculated the neutralization efficiency. An Ar neutral beam flux of more than 1 mA/cm{sup 2} in equivalent current density and a neutralization efficiency of more than 99% were obtained. The spatial uniformity of the neutral beam flux was within {+-}6% within a 100 mm diameter. Silicon etching using a F{sub 2}-based neutral beam was done at an etch rate of about 47 nm/min, while Cl{sub 2}-based neutral beam realized completely no undercut. The uniformity of etch rate was less than {+-}5% within the area. The etch rate increased by applying bias power to the neutralization aperture plate, which shows that accelerated neutral beam was successfully obtained. These results indicate that the neutral beam source is scalable, making it possible to obtain a large-diameter and uniform neutral beam, which is inevitable for application to mass production.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hyperthermal neutral beam sources for material processing (invited)

Hyperthermal neutral beams have a great potential for material processes, especially for etching and thin film deposition for semiconductor and display fabrication as well as deposition for various thin film applications. Plasma-induced damage during plasma etching is a serious problem for manufacturing deep submicron semiconductor devices and is expected to be a problem for future nanoscale devices. Thermal and plasma-induced damage is also problematic for thin film depositions such as transparent conductive oxide films on organic light emitting diodes or flexible displays due to high temperature processes in plasma environments. These problems can be overcome by damage-free and low-temperature processes with hyperthermal neutral beams. We will present the status of the hyperthermal neutral beam development and the applications, especially, in semiconductor and display fabrication and introduce potential applications of thin film growing for optoelectronic devices such as light emitting diodes.

36 MATERIALS SCIENCE↗

Numerical simulation for the accelerator of the KSTAR neutral beam ion source

Recent experiments with a prototype long-pulse, high-current ion source being developed for the neutral beam injection system of the Korea Superconducting Tokamak Advanced Research have shown that the accelerator grid assembly needs a further upgrade to achieve the final goal of 120keV/65A for the deuterium ion beam. The accelerator upgrade concept was determined theoretically by simulations using the IGUN code. The simulation study was focused on finding parameter sets that raise the optimum perveance as large as possible and reduce the beam divergence as low as possible. From the simulation results, it was concluded that it is possible to achieve this goal by sliming the plasma grid (G1), shortening the second gap (G2-G3), and adjusting the G2 voltage ratio.

43 PARTICLE ACCELERATORS↗

The development of the radio frequency driven negative ion source for neutral beam injectors (invited)

Large and powerful negative hydrogen ion sources are required for the neutral beam injection (NBI) systems of future fusion devices. Simplicity and maintenance-free operation favors RF sources, which are developed intensively at the Max-Planck-Institut fuer Plasmaphysik (IPP) since many years. The negative hydrogen ions are generated by caesium-enhanced surface conversion of atoms and positive ions on the plasma grid surface. With a small scale prototype the required high ion current density and the low fraction of co-extracted electrons at low pressure as well as stable pulses up to 1 h could be demonstrated. The modular design allows extension to large source dimensions. This has led to the decision to choose RF sources for the NBI of the international fusion reactor, ITER. As an intermediate step towards the full size ITER source at IPP, the development will be continued with a half-size source on the new ELISE testbed. This will enable to gain experience for the first time with negative hydrogen ion beams from RF sources of these dimensions.

43 PARTICLE ACCELERATORS↗

Dynamics of ion beam charge neutralization by ferroelectric plasma sources

Ferroelectric Plasma Sources (FEPSs) can generate plasma that provides effective space-charge neutralization of intense high-perveance ion beams, as has been demonstrated on the Neutralized Drift Compression Experiment NDCX-I and NDCX-II. This article presents experimental results on charge neutralization of a high-perveance 38 keV Ar + beam by a plasma produced in a FEPS discharge. By comparing the measured beam radius with the envelope model for space-charge expansion, it is shown that a charge neutralization fraction of 98% is attainable with sufficiently dense FEPS plasma. The transverse electrostatic potential of the ion beam is reduced from 15V before neutralization to 0.3 V, implying that the energy of the neutralizing electrons is below 0.3 eV. Measurements of the time-evolution of beam radius show that near-complete charge neutralization is established similar to –5 μs after the driving pulse is applied to the FEPS and can last for 35 μs. It is argued that the duration of neutralization is much longer than a reasonable lifetime of the plasma produced in the sub-mu s surface discharge. Measurements of current flow in the driving circuit of the FEPS show the existence of electron emission into vacuum, which lasts for tens of mu s after the high voltage pulse is applied. Lastly, it is argued that the beam is neutralized by the plasma produced by this process and not by a surface discharge plasma that is produced at the instant the high-voltage pulse is applied.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of ion source with a washer gun for pulsed neutral beam injection

A new type of economical neutral beam source has been developed by using a single washer gun, pulsed operation, and a simple electrode system. We replaced the conventional hot filaments for arc-discharge-type plasma formation with a single stainless-steel washer gun, eliminating the entire dc power supply for the filaments and the cooling system for the electrodes. Our initial experiments revealed successful beam extraction up to 10 kV and 8.6 A, based on spatial profile measurements of density and temperature in the plasma source. The system also shows the potential to control the beam profile by controlling the plasma parameters in the ion accumulation chamber.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First plasma of megawatt high current ion source for neutral beam injector of the experimental advanced superconducting tokamak on the test bed

High current ion source is the key part of the neutral beam injector. In order to develop the project of 4 MW neutral beam injection for the experimental advanced superconducting tokamak (EAST) on schedule, the megawatt high current ion source is prestudied in the Institute of Plasma Physics in China. In this paper, the megawatt high current ion source test bed and the first plasma are presented. The high current discharge of 900 A at 2 s and long pulse discharge of 5 s at 680 A are achieved. The arc discharge characteristic of high current ion source is analyzed primarily.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress and future developments of high current ion source for neutral beam injector in the ASIPP

A high current hot cathode bucket ion source, which based on the US long pulse ion source is developed in Institute of Plasma Physics, Chinese Academy of Sciences. The ion source consists of a bucket plasma generator with multi-pole cusp fields and a set of tetrode accelerator with slit apertures. So far, four ion sources are developed and conditioned on the ion source test bed. 4 MW hydrogen beam with beam energy of 80 keV is extracted. In Aug. 2013, EAST NBI 1 with two ion source installed on the EAST, and achieved H-mode plasma with NBI injection for the first time. In order to achieve stable long pulse operation of high current ion source and negative ion source research, the RF ion source with 200 mm diameter and 120 mm depth driver is designed and developed. The first RF plasma generated with 2 kW power of 1 MHz frequency. More of the RF plasma tests and negative source relative research need to do in the future.

43 PARTICLE ACCELERATORS↗

Development of a plasma generator for a long pulse ion source for neutral beam injectors

A plasma generator for a long pulse H{sup +}/D{sup +} ion source has been developed. The plasma generator was designed to produce 65 A H{sup +}/D{sup +} beams at an energy of 120 keV from an ion extraction area of 12 cm in width and 45 cm in length. Configuration of the plasma generator is a multi-cusp bucket type with SmCo permanent magnets. Dimension of a plasma chamber is 25 cm in width, 59 cm in length, and 32.5 cm in depth. The plasma generator was designed and fabricated at Japan Atomic Energy Agency. Source plasma generation and beam extraction tests for hydrogen coupling with an accelerator of the KSTAR ion source have been performed at the KSTAR neutral beam test stand under the agreement of Japan-Korea collaborative experiment. Spatial uniformity of the source plasma at the extraction region was measured using Langmuir probes and {+-}7% of the deviation from an averaged ion saturation current density was obtained. A long pulse test of the plasma generation up to 200 s with an arc discharge power of 70 kW has been successfully demonstrated. The arc discharge power satisfies the requirement of the beam production for the KSTAR NBI. A 70 keV, 41 A, 5 s hydrogen ion beam has been extracted with a high arc efficiency of 0.9 -1.1 A/kW at a beam extraction experiment. A deuteron yield of 77% was measured even at a low beam current density of 73 mA/cm{sup 2}.

43 PARTICLE ACCELERATORS↗

Modeling of an Inductive Negative Ion Source for Neutral Beam Injection

We present a self-consistent two-dimensional model of a high-power inductive plasma source for negative ion production in hydrogen. The model is quasi-neutral and describes the transport and chemistry of different particle species by fluid equations including inertia and viscosity terms, coupled with the electromagnetic fields from the Maxwell equations. Results for typical conditions show a depletion of the neutral density in the plasma center and a possible reduction of wall losses due to the Lorentz force from the driving field at lower frequencies (<20 MHz)

43 PARTICLE ACCELERATORS↗

Compact electron-beam source for formation of neutral beams of very low vapor pressure materials

In order to form metal vapors for neutral beam studies, an electron-beam heater and a power supply have been designed. The source, which measures about 30 x 50 x 70 mm, consists of a filament, accelerating plate (defined by pole pieces), and a supported target. The electrons from the filament are focused by the field penetration through a 2 mm slit in the high-voltage cage. They are then accelerated to about 5 kV to a ground plate. The electrons then follow a path in the magnetic field and strike the sample to be heated on its front surface. The assembly is attached to a water-cooled base plate. The electron beam source has produced beams of Ta and C particles with densities of about 10 to the 8th power/cu cm.

Rutherford, J. A.↗

Improvement of a plasma uniformity of the 2nd ion source of KSTAR neutral beam injector

The 2nd ion source of KSTAR (Korea Superconducting Tokamak Advanced Research) NBI (Neutral Beam Injector) had been developed and operated since last year. A calorimetric analysis revealed that the heat load of the back plate of the ion source is relatively higher than that of the 1st ion source of KSTAR NBI. The spatial plasma uniformity of the ion source is not good. Therefore, we intended to identify factors affecting the uniformity of a plasma density and improve it. We estimated the effects of a direction of filament current and a magnetic field configuration of the plasma generator on the plasma uniformity. We also verified that the operation conditions of an ion source could change a uniformity of the plasma density of an ion source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion source for neutral beam injection meant for plasma and magnetic field diagnostics

At the Lawrence Berkeley National Laboratory a diagnostic neutral beam injection system for measuring plasma parameters, flow velocity, and local magnetic field is being developed. The system is designed to have a 90% proton fraction and small divergence with beam current at 5-6 A and a pulse length of {approx}1 s occurring once every 1-2 min. The ion source needs to generate uniform plasma over a large (8x5 cm{sup 2}) extraction area. For this application, we have compared rf driven multicusp ion sources operating with either an external or an internal antenna in similar ion source geometry. The ion beam will be made of an array of six sheet-shaped beamlets. The design is optimized using computer simulation programs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Caesium Free Negative Ion Sources for Neutral Beam Injectors: a Study of Negative Ion Production on Graphite Surface in Hydrogen and Deuterium Plasma

Negative ion generation on HOPG graphite surface has been studied in hydrogen and deuterium plasma. We measure Ion Distribution Function (IDF) of negative ions coming from graphite surface bombarded by positive ions in H{sub 2}/D{sub 2} plasmas. We showed that negative ions flux was proportional to positive ion flux and was strongly dependant on impinging energy. IDF study shows two generation mechanisms are involved: sputtering of adsorbed H/D as negative ions and, in a less important way, double electron capture. We compare H{sub 2}/D{sub 2} plasmas, and point out isotopic effect between H{sup -} and D{sup -} production.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The dependence of extracted current on discharge gas pressure in neutral beam ion sources on HL-2A tokamak

The discharge gas pressure is a key factor to influence the extracted current of ion source. In this paper, the dependence of extracted current on discharge gas pressure was investigated in detail at different arc discharge currents. The discharge gas pressure with a very broad range (0.1 Pa-2.7 Pa) was scanned for the first time. It is turned out that, with the increasing of discharge gas pressure, the extracted current increases and the arc voltage decreases at different arc currents; however, when the discharge gas pressure exceeds a certain value, the extracted current decreases. For the same discharge gas pressure, the higher the arc current, the higher the arc voltage and the extracted current are. The arc efficiency was also calculated, and its dependence on gas pressure was almost the same with the dependence of extracted current on gas pressure, but at the same discharge gas pressure, the lower the arc current, the higher the arc efficiency is and the lower the extracted current is.

43 PARTICLE ACCELERATORS↗

Quasi-steady carbon plasma source for neutral beam injector

Carbon plasma is successfully sustained during 1000 s without any carrier gas in the bucket type ionization chamber with cusp magnetic field. Every several seconds, seed plasmas having ∼3 ms duration time are injected into the ionization chamber by a shunting arch plasma gun. The weakly ionized carbon plasma ejected from the shunting arch is also ionized by 2.45 GHz microwave at the electron cyclotron resonance surface and the plasma can be sustained even in the interval of gun discharges. Control of the gun discharge interval allows to keep high pressure and to sustain the plasma for long duration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Angular-divergence calculation for Experimental Advanced Superconducting Tokamak neutral beam injection ion source based on spectroscopic measurements

Calorimetric method has been primarily applied for several experimental campaigns to determine the angular divergence of high-current ion source for the neutral beam injection system on the Experimental Advanced Superconducting Tokamak (EAST). A Doppler shift spectroscopy has been developed to provide the secondary measurement of the angular divergence to improve the divergence measurement accuracy and for real-time and non-perturbing measurement. The modified calculation model based on the W7AS neutral beam injectors is adopted to accommodate the slot-type accelerating grids used in the EAST's ion source. Preliminary spectroscopic experimental results are presented comparable to the calorimetrically determined value of theoretical calculation.

43 PARTICLE ACCELERATORS↗