At least 19 records

Boron coated straw-based neutron multiplicity counter for neutron interrogation of TRISO fueled pebbles

Pebble bed reactors (PBRs) can improve the safety and economics of the nuclear energy production. PBRs rely on TRIstructural-ISOtropic (TRISO) fuel pebbles for enhanced fission product retention. Accurate characterization of individual fuel pebbles would enable the validation of computational models, efficient use of TRISO fuel, and improve fuel accountability. Here, we have developed and tested a new neutron multiplicity counter (NMC) based on 192 boron coated straw (BCS) detectors optimized for 235 U assay in TRISO fuel. The new design yielded a singles and doubles neutron detection efficiency of 4.71% and 0.174%, respectively, and a die-away time of 16.7 μs. The NMC has a low intrinsic gamma-ray detection efficiency of 8.71 x 10 –8 at an exposure rate of 80.3 mR/h. In simulation, a high-efficiency version of the NMC encompassing 396 straws was able to estimate the 235 U in a pebble with a relative uncertainty and error both below 2% in 100 s.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A compact, low-power epithermal neutron counter for lunar water detection

The detection and characterization of lunar water are critical for enabling sustainable human and robotic exploration of the Moon. Orbital neutron spectrometers, such as instruments on Lunar Prospector and the Lunar Reconnaissance Orbiter, have revealed hydrogen-rich regions near the poles but are limited by coarse spatial resolution and low counting efficiency. We present a compact, lightweight, and low-power epithermal neutron detector based on boron-coated silicon imagers, designed to probe subsurface hydrogen at decimeter scales from mobile platforms such as lunar rovers. This instrument leverages the high neutron capture cross-section of 10 B to convert epithermal neutrons into detectable α and 7 Li ions in a fully-depleted silicon imager, providing a unique event topology to identify neutrons while suppressing backgrounds. Monte Carlo simulations demonstrate that a 3 μm boron layer achieves optimal neutron detection efficiency, further enhanced with polyethylene moderation to improve sensitivity to the 0.4 eV–500 keV epithermal energy range. For a 10 cm 2 active area, the detector achieves sensitivity to H 2 O weight fractions as low as 0.01 wt% in a 15 minute measurement. This scalable, portable, low-mass design is well-suited for integration into upcoming Artemis and commercial lunar rovers, providing a transformative capability for in-situ resource prospecting and ground-truth validation of orbital measurements.

Detector modelling and simulations I (interaction ↗

Performance Characterization of FB-Line Neutron Multiplicity Counter and Large Neutron Multiplicity Counter

Savanah River National Laboratory’s (SRNL) Nuclear Measurements group was tasked with characterizing the performance of two neutron multiplicity counters located at SRNL. Characterization measurements were made to determine the gate width, pre-delay, deadtime parameters, triples and doubles gate fractions, detector efficiency, and operating high voltage for the Large Neutron Multiplicity Counter (LNMC) and the FB Line Neutron Multiplicity Counter (FBLNMC). The parameters were determined, shown below, and were, as to be expected, slightly different than the previous calibrations, which were performed over 20 years ago. Several Pu samples were measured to validate the characterizations of the FBLNMC and LNMC. The measurements determined the sample Pu-240 mass within <2% deviation for the pure plutonium samples and ~8% for the mixed oxide sample. The pure Pu samples had significantly better accuracy compared with the impure mixed oxide sample due to the lack of induced fission or alpha,n neutrons from impurities. Overall, the characterization of the neutron multiplicity counters, and the determination of their operability has been completed successfully.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distinguishing fissile uranium isotopes using an active well neutron coincidence counter

Proposed thorium-based nuclear fuel cycles are likely to require quantification and verification of 233 U within nuclear material. Because of their similar fission cross sections, active neutron nondestructive assay (NDA) systems may respond similarly to 233 U and 235 U. Traditional safeguards equipment has been optimized for 235 U and 238 U quantification associated with conventional uranium/plutonium fuel cycles and may not be directly applicable to 233 U quantification when mixed with other actinides. This work used models of the large volume active well coincidence counter (LV-AWCC) at Oak Ridge National Laboratory to evaluate the performance of this neutron NDA system to differentiate fissile uranium isotopes. The models were developed to simulate NDA system performance in response to a number of triangular radiation signature training device sources within the central cavity or well. This work predicted that the LV-AWCC can effectively differentiate 233 U from 235 U in certain modes of operation. In active mode, the LV-AWCC with the cadmium liner results in different doubles count rates between the fissile isotopes for a given fissile uranium mass. Without the cadmium liner, the uranium isotopes provide a statistically indistinguishable doubles count rate response for the fissile masses considered in this work (up to approximately 150 g). The cadmium liner serves to harden the neutron interrogation spectrum, which better exploits the notable difference in the 233 U and 235 U fission cross sections at approximately 1 eV. In passive mode, the two fissile isotopes exhibit different doubles and singles count rates regardless of liner presence because the passive source strength of 233 U is approximately 2 orders of magnitude stronger than that of 235 U due to the shorter half-life and correspondingly higher (α, n) yield. We conclude that using neutron interrogation in the LV-AWCC, two measurements are needed to quantify 233 U content in mixed uranium items. The first measurement is used to determine the total fissile uranium mass using a mode that cannot distinguish fissile isotopes (i.e., where a similar response is observed for both fissile uranium isotopes such as active doubles without cadmium or using a thermal neutron interrogation source). In conclusion, the second measurement is used to determine the 233 U content by using a differentiating technique (e.g., passive doubles, passive doubles to singles ratio, active doubles with cadmium).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HIGHER EFFICIENCY FISSION COUNTER FOR NEUTRON DETECTION

Fission chambers containing 235U have been used for detection of neutrons for many decades. In these chambers 235U is electroplated on a metal which is one plate of an ionization chamber. Since the range of fission products from induced fission in the chamber is extremely short, these deposits from electroplating are so thin that the amount of 235U results in low neutron detection efficiency and the chamber needs high internal 235U surface area to increase efficiency. A typical ~8 in. long, ~2 in. diameter fission counter only contains < 2 g of 235U total, resulting in very low detection efficiency per incident neutron impinging on the outer surface of the detector. However, because of their large electronic pulses from fission products compared to gamma rays it is very easy to discriminate against gamma rays impinging on the detector. These types of chambers are produced commercially and are used worldwide in nuclear research and nuclear power reactors. ORNL has made a higher efficiency fission ionization chamber by using many thin concentric annuli to increase the area. A higher efficiency fission counter would be useful and can be made by incorporating 235U into a glass or ceramic scintillator. For nearly 100 years the green color in antique glass was produced by incorporation of depleted uranium (up to 20 wt. %) into a glass. The concept for this scintillation-optical-based fission detector is to dope a scintillator (either ceramic or glass) with 235U. Glass scintillators are commercially available doped with as much as 8 wt. % 6Li for neutron detection. In the 235U doped scintillator the fission product pulses would be double the size of those in an ion chamber since all fission products produce light in the scintillator whereas in the ionization chamber half do not go into the ionizing gas volume. These higher efficiency fission chambers would be very useful for a wide variety of research, nuclear research, and nuclear power reactor applications. Because of their smaller size and weight, they should be useful for space application such as monitoring of space nuclear power reactors. This report reviews existing fission chamber technology and suggests the development of these small high-efficiency fission chambers. Other fission isotopes could be used for other research applications.

Mihalczo, John [ORNL] (ORCID:0000000254292681)↗

β -delayed neutron emissions from N > 50 gallium isotopes

β-delayed γ-neutron spectroscopy has been performed on the decay of A = 84 to 87 gallium isotopes at the RI-beam Factory at the RIKEN Nishina Center using a high-efficiency array of 3 He neutron counters (BRIKEN). β-2n-γ events were measured in the decays of all of the four isotopes for the first time, which is direct evidence for populating the excited states of two-neutron daughter nuclei. Detailed decay schemes with the γ branching ratios were obtained for these isotopes, and the neutron emission probabilities (P xn ) were updated from the previous study. Hauser-Feshbach statistical model calculations were performed to understand the experimental branching ratios. We found that the P 1n and P 2n values are sensitive to the nuclear level densities of 1n daughter nuclei and showed that the statistical model reproduced the P 2n /P 1n ratio better when experimental levels plus shell-model level densities fit by the Gilbert-Cameron formula were used as the level-density input. We also showed the neutron and γ branching ratios are sensitive to the ground-state spin of the parent nucleus. Our statistical model analysis suggested J ≤ 3 for the unknown ground-state spin of the odd-odd nucleus 86 Ga, from the I γ (4 + → 2 + )/I γ (2 + → 0 + ) ratio of 84 Ga and the P 2n /P 1n ratio. In conclusion, these results show the necessity of detailed understanding of the decay scheme, including data from neutron spectroscopy, in addition to γ measurements of the multineutron emitters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Two Extraordinary AmLi Neutron Sources

Two legacy AmLi sources, MRC-101 and MRC-103, are routinely used for neutron detector characterization and testing campaigns that Pacific Northwest National Laboratory manages for the Defense Threat Reduction Agency within the U.S. Department of Defense. However, applicability of source measurement data has been substantially limited due to the lack of original manufacturer documentation and cross comparison to other sources. This paper summarizes results of the measurement campaign conducted to better quantify source radionuclide content, neutron energy spectrum and emission rate of the AmLi sources. The source characterization study consisted of three major consecutive measurement exercises. First, gamma spectrometry measurements using a high purity germanium detector were used to estimate the radionuclide content and potential impurities of the AmLi sources. Then neutron spectral measurements were taken to determine the unique neutron energy distribution. Finally, assessments of the total neutron yields of the sources were made with measurements in a neutron well counter. The neutron detection efficiency for these measurements was determined via detailed Monte Carlo modeling based on the neutron energy distribution measured with the rotating neutron spectrometer. The most exciting and unexpected finding of the study was a significant contamination of the source material with beryllium, contributing up to 17% to the total neutron emission rate and correspondingly changing the neutron energy spectrum. Also, the obtained lithium-only portion of the measured energy distribution of the sources was compared against several AmLi spectra previously reported by different researchers.

AWCC, AmLi, beryllium contamination, neutron spect↗

Burnup Monitoring for Pebble Bed Reactor Systems

A pebble burnup monitoring system is a required component for domestic reactor safety and safeguards applications associated with pebble bed reactors (PBRs). One of the main requirements of a PBR burnup monitoring system is that it needs to be capable of rapid measurements to assess the burnup of each individual pebble to determine whether to recirculate it in the reactor or discard it as spent fuel. This report considers three different approaches for a burnup monitoring system for pebbles discharged from the reactor core in a pebble bed modular reactor-400: • passive gamma spectrometry measurement, • passive neutron coincidence measurement, and • active neutron counter based on the differential die-away technique. Conceptual designs have been created for each of these detectors, and preliminary analysis has been performed using Monte Carlo N-Particle and Oak Ridge Isotope Generation code simulations. The advantages and practical limitations (e.g., high radiation background) of each system were identified. Simulations suggest that each of the three measurement techniques can be successfully employed to distinguish between pebbles based on their number of passes through the core and to quantify the burnup of pebbles.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Plutonium Mass Uncertainty Assessment Using a Cherenkov-Based Neutron Multiplicity Water Detector

We present a new analysis of the sensitivity of a water Cherenkov-based neutron multiplicity counter for nondestructive assay of trace quantities of 240 Pu. The multiplicity counter [water-based neutron detector (WaND)] contains 1.0 m 3 of water doped with 0.2% gadolinium in the form of a gadolinium salt (0.4% GdCl 3 ). It can be used for testing the presence of trace quantities of 240 Pu within a sample of unknown material by observing the correlated timing behavior of neutron capture candidates in the detector. The new analysis takes advantage of the fact that the detector is comprised almost entirely of a homogeneous medium, which permits the use of a simple model to reproduce the observed neutron capture timing behavior. Finally, the results of this analysis indicate that the detector has an absolute neutron detection efficiency of 23.4 ± 1.1% and is sensitive to a 240 Pu mass as small as 2.3 mg (at 1σ) after a 1-h data acquisition.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

AWCC Simulations

Neutron well counters provide a means to measure fissile mass by detecting coincident neutrons, which is a unique signature to fission. For coincidence counting, mass is determined using a calibration curve established with items that have the same material characteristics. Multiplicity analysis solves the point model equations for mass using known detector parameters. In both cases, mass measurements may exhibit a bias due to item characteristics and should be corrected for. Experiments can be done to estimate bias and material effects, but they require having both the well counter and the material well defined. In pursuit of estimating measurement bias and uncertainty in a High Efficiency Neutron Counter (HENC), an MCNP simulation was matched to measurements performed with an Active Well Coincidence Counter (AWCC) to de ne a neutron source term. The neutron source term will be used to predict measurement performance of similar material types in a HENC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Special Nuclear Material Mass Estimates from Neutron Singles Count Rate [Poster]

The objective of this research was to create an algorithm to provide an estimate of special nuclear material (SNM) mass using only neutron count rate data from a Radioisotope Identification Device (RIID), rather than using time-correlated data from a neutron multiplicity counter. To meet this objective neutron count rate measurements of a 252 Cf source were taken at varying distances with an ORTEC Detective X, FLIR Identifinder 2, and an ORTEC RADEAGLET-R. An algorithm was created to estimate mass of SNM utilizing the singles rate equation and the measured absolute efficiency curves.

FLIR↗

MC-Lite: Development of a new lightweight multiplicity counter

This report details the development of a neutron multiplicity counter based on lithium doped plastic scintillators. This system has the capability to measure and discriminate fast neutrons, thermal neutrons, and gamma-rays allowing for multi-particle correlations in one device. The system was built and tested at Lawrence Livermore National Laboratory with Cf-252 in both bare configurations and surrounded by polyethylene and compared against the MC-15 multiplicity counter. Additionally, the detector was also placed outside of a subcritical assembly and demonstrated the ability to use correlated gamma-rays as a probe on the multiplication of the item.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

233 U oxide Measurement Campaign Data: Passive and Active Neutron Multiplicity Measurements of Uranium Oxide Samples at Oak Ridge National Laboratory

During FY2023, three measurement campaigns were conducted at Oak Ridge National Laboratory. The goal was to quantify the neutron signatures of samples of uranium oxide containing uranium 233 and uranium-235. This report presents the neutron multiplicity data obtained using the large volume active well coincidence counter (LV-AWCC).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low-energy measurement of the 25 Mg ⁢(𝛼,𝑛)⁢ 28 Si reaction via neutron spectroscopy

During core helium and carbon burning in massive stars, neutrons are produced mainly by the 22 Ne⁢ (𝛼,𝑛) ⁢25 Mg reaction. Some of these released neutrons are captured by heavy seed nuclei from previous nucleosynthesis events, resulting in the slow production of many of the elements between masses 60 ≤ 𝐴 ≤ 90 via the weak 𝑠 process. Determining the overall neutron flux available in this environment is one of the main challenges in modeling its contributions to heavy element production. Not only must the reaction rate be well defined for the primary neutron source, but the rates of neutron poison and recycling reactions must also be well determined. One critical reaction in the simulation network is 25 Mg ⁢(𝛼,𝑛) ⁢ 28 Si. This reaction, together with 25 Mg ⁢(𝑛,𝛾)⁢ 26 Mg and 25 Mg⁢ (𝛼,𝛾) ⁢ 29 Si, determine how 25 Mg nuclei affect the available neutron flux. Past attempts to measure the 25 Mg ⁢(𝛼,𝑛)⁢ 28 Si cross section using neutron moderator counters have been greatly hindered by lower-𝑍 background reactions. Here, in the present work, neutron spectroscopy with deuterated liquid scintillator detectors has been used. The experimental spectra have been analyzed by applying spectrum unfolding techniques to achieve improved background discrimination for the 25 Mg⁢ (𝛼,𝑛)⁢ 28 Si reaction at low energies, down to 𝐸 𝛼 = 1.75 MeV. The separation of the different background contributions gives further insight into the results of previous moderator counter measurements and the measurements lead to a revised and more reliable determination of the reaction rate.

hydrostatic stellar nucleosynthesis↗

An Integrated Approach to Precision Neutron Measurements in a Dynamic Environment [Slides]

Any quantity of special nuclear material must be accurately quantified for health, safety, and security concerns. High-Level Neutron Coincidence Counters (HLNCCs) are detectors used for assaying the mass of special nuclear material. HLNCCs record a neutron count rate over some period of time which is compared to a calibration curve to determine the quantity of special nuclear material present within the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Impure Plutonium Oxide Neutron Calibration Standards through Evaluation by Neutron Multiplicity Equations

Plutonium oxide calibration standards STD4C, STD6C and STD8C have been historically used, and are currently the only MT52 standards in use, for calibration and measurement control program of Passive/Active Neutron Coincidence Counter known as PAN1 at PF-4. In this paper, previously measured high-statistics data are used in conjunction with neutron multiplicity equations to determine multiplication M and α parameter of these standards as the explicit knowledge of these parameters may allow quantification of precision and bias of accountability measurements of different material types and matrices of items.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗