Search NASA⌕ Search

SEARCH · Search NASA

Results for “NEUTRON FLUENCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Modeling and Design of Micro Flux Monitors for Neutron Fluence Measurements

Measuring neutron flux is critical to understanding the characteristics of nuclear reactors and can provide information on the energy spectrum, total neutron fluence, and operational history of a facility. Such measurements are typically performed by irradiating high-purity materials in an operating reactor for a known length of time. By measuring and identifying activation products in the irradiated materials and referencing the energy-dependent cross section of each isotope, the neutron energy spectrum and total fluence can be determined. Historical techniques use a variety of small, individually pressed foils or wires for dosimeter devices, which can result in excessively high levels of radioactivity and complications in handling after irradiation. The present work describes a new neutron dosimetry concept, named the micro flux monitor, that uses semiconductor device fabrication processes to deposit thin films of flux monitoring materials in precise geometries onto a SiC wafer. This approach allows multiple dosimetry materials to be located on a single device, simplifying irradiation and subsequent analysis. The geometry, and therefore mass, of each material can be custom-tailored for a specific application—considering the expected neutron flux, duration of irradiation, and device retrieval time of a facility. Additionally, hundreds of identical dosimetry monitors can be produced simultaneously, reducing fabrication costs. Finally, the extremely thin metal dimensions of these devices could improve the fidelity of neutron fluence measurements by reducing neutron self-shielding and gamma self-attenuation effects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Anisotropy of the neutron fluence from a plasma focus.

The fluence of neutrons from a plasma focus was measured by gamma spectrometry of an activated silver target. This method results in a significant increase in accuracy over the beta-counting method. Multiple detectors were used in order to measure the anisotropy of the fluence of neutrons. The fluence was found to be concentrated in a cone with a half-angle of 30 deg about the axis, and to drop off rapidly outside of this cone; the anisotropy was found to depend upon the total yield of neutrons. This dependence was strongest on the axis. Neither the axial concentration of the fluence of neutrons nor its dependence on the total yield of neutrons is explained by any of the currently proposed models. Some other explanations, including the possibility of an axially distributed source, are considered.

Lee, J. H.↗

Measured Thermal and Fast Neutrons Fluence Rates for ATF-1 Holders During ATR Cycle 166B

This report contains the thermal (2200 m/s) and fast (E>lMeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 166B which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains measurements of the fluence rates corresponding to the particular elevations relative to the 80-ft. core elevation. The data in this report consist of (1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, and (3) plots of both the thermal and fast neutron fluence rates. All "BR" holder monitor wires for this cycle are 56.375 inches long. This length allows measurements from 31.17 inches above core midplane to 19.81 inches below core midplane. The distance from the end of the wires to the first count position was 4.25 inches for all wires counted from this cycle. The monitors were located in an outward small I-holes,1-22 and 1-23. Thermal neutron fluence was determined based on the activation of the CoAl wires and resonance corrections determined in the irradiation of Cycle 152A when the RML measured cadmium-covered as well as bare neutron monitors in the Southwest, Southeast, and H positions at the Center lobe to determine the division in neutron energy between epithermal and thermal neutrons. For more information please refer to letter “Radiation Measurements Laboratory measurements of in core ATR physics testing during cycle 152A. The measured values documented in RML procedure, “ACMM-3600, Flux Monitoring,” will be used indefinitely until further measurements supersede the current values. Fast neutron fluence was determined using the activation of nickel wires. Typically, a fission spectrum averaged cross section (E>1 MeV) is used as determined in detailed measurements described in “ATR Neutron Spectral Characterization,” which gives an effective cross section of 97 mb for the small I-holes. However, those measurements were performed with unfueled experiments. The fast fluence values reported here use a perturbed 114 mb effective>1 MeV spectrum averaged cross section for the small I-holes based on MCNP simulations for a previous fueled experiment in the1-24 position. Refer to “LWR- ATR Irradiation Measured Thermal and Fast Neutron Fluence Rates ATR CYCLE 133A 04/19/04 thru 05/17/04” for more information.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measured Thermal And Fast Neutron Fluence Rates ATR Cycle 169A

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 169A which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains fluence rate values corresponding to the particular elevations (relative to the 80-ft. core elevation) where the measurements were taken. The data in this report consists of ( 1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, (3) plots of both the thermal and fast neutron fluence rates, and (4) an optical record (compact disk) containing a listing of the thermal and the fast neutron fluence rates, their assigned elevations and proper header identification of all monitor positions contained herein. The fluence rates reported are for the average power levels given in the table of power history and distribution. No neutron monitors were located in the N-2 position during this cycle. All "SR" holder monitor wires for this cycle are 55 inches long. This length allows measurements from 24.73 inches above core midplane to 25.25 inches below core midplane. The distance from the end of the wires to the first count position was 4.25 inches for all wires counted from this cycle.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Practical new method of measuring thermal-neutron fluence

Thermoluminescence dosimeter technique measures thermal-neutron fluence by encapsulating lithium flouride phosphor powder and exposing it to a neutron environment. The capsule is heated in a dosimeter reader, which results in light emission proportional to the neutron fluence.

Siebold, J. R.↗

Measured Thermal And Fast Neutron Fluence Rates ATR Cycle 166B

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 166B which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains fluence rate values corresponding to the particular elevations (relative to the 80-ft. core elevation) where the measurements were taken. The data in this report consists of (1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, (3) plots of both the thermal and fast neutron fluence rates, and (4) an optical record (compact disk) containing a listing of the thermal and the fast neutron fluence rates, their assigned elevations and proper header identification of all monitor positions contained herein. The fluence rates reported are for the average power levels given in the table of power history and distribution. No neutron monitors were located in the N-2 position during this cycle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Measured Thermal and Fact Neutron Fluence Rates for AFC Holders During Cycle 169A

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for the AFC holders located in core for ATR Cycle 169A which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains measurements of the fluence rates corresponding to the particular elevations relative to the 80-ft. core elevation. The data in this report consist of (1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, and (3) plots of both the thermal and fast neutron fluence rates. All "BR" holder monitor wires for this cycle are 56.375 inches long. This length allows measurements from 31.17 inches above core midplane to 19.81 inches below core midplane. The distance from the end of the wires to the first count position was 4.25 inches for all wires counted from this cycle.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measured Thermal and Fast Neutron Fluence Rates for aLEU Holders During Cycle 169A

This report contains the thermal (2200 mis) and fast (E> IMeV) neutron fluence rate data for the aLEU holders located in core for ATR Cycle 169A which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains measurements of the fluence rates corresponding to the particular elevations relative to the 80-ft. core elevation. The data in this report consist of (1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, and (3) plots of both the thermal and fast neutron fluence rates. All "BR" holder monitor wires for this cycle are 56.375 inches long. This length allows measurements from 31.17 inches above core midplane to 19.81 inches below core midplane. The distance from the end of the wires to the first count position was 4.25 inches for all wires counted from this cycle.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of HELIOS/BIPR/PARCS/MCNP6 Computation Route for WWER RPV Neutron Fluence Analysis and Validation Against Ex-Vessel Detector Measurement Data

Here, a computational route was developed for precise calculation of fast neutron fluence on a WWER-type reactor pressure vessel (RPV). The method is based on the transfer of neutronics data from HELIOS-2 lattice calculations and nodal diffusion neutronics data (power, density, and temperature) from BIPR7.1 and PARCS 3.36/PATHS core calculations into a three-dimensional (pinwise axially distributed) fixed neutron source for modeling of transport of fast neutrons from the reactor core to the outer surface of the RPV using MCNP6.2. Validation of the proposed computational method was carried out based on comparative analysis of MCNP6.2-predicted and neutron dosimetry–measured reaction rates [ 54 Fe(n,p) 54 Мn, 93 Nb(n,n') 93 mNb, and 58 Ni(n,р) 58 Со] on the outer surface of the Armenian Nuclear Power Plant (ANPP) Unit 2 RPV. Validation revealed that the MCNP6.2-predicted fast neutron fluence results are very sensitive to the ENDF-B neutron data. Particularly, MCNP6.2 with ENDF/B-VIII.0 significantly underpredicts (20% to 30%) fast neutron fluence while using ENDF/B-VII.1 data overpredicts it. Adding revised beta-released evaluations of 54 Fe, 56 Fe, 57 Fe, and 16 O from the International Nuclear Data Evaluation Network (INDEN) to ENDF/B-VIII.0 allows one to obtain reasonable agreement with measurement results for all types of measured reaction rates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measured Thermal and Fast Neutron Fluence Rates ATR Cycles 167A

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 167A which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. The report contains fluence rate values corresponding to the particular elevations (relative to the 80-ft. core elevation) where the measurements were taken. The data in this report consists of (1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, (3) plots of both the thermal and fast neutron fluence rates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron fluences and dose equivalents measured with passive detectors on LDEF

Neutron fluences were measured on LDEF in the low energy (< 1 MeV) and high energy (> 1 MeV) ranges. The low energy detectors used the 6Li(n,alpha)T reaction with Gd foil absorbers to separate thermal (< 0.2 eV) and resonance (0.2 eV-1 MeV) neutron response. High energy detectors contained sets of fission foils (181Ta, 209Bi, 232Th, 238U) with different neutron energy thresholds. The measured neutron fluences together with predicted spectral shapes were used to estimate neutron dose equivalents. The detectors were located in the A0015 and P0006 experiments at the west and Earth sides of LDEF under shielding varying from 1 to 19 g/cm2. Dose equivalent rates varied from 0.8 to 3.3 microSv/d for the low energy neutrons and from 160 to 390 microSv/d for the high energy neutrons. This compares with TLD measured absorbed dose rates in the range of 1000-3000 microGy/d near these locations and demonstrates that high energy neutrons contribute a significant fraction of the total dose equivalent in LEO. Comparisons between measurements and calculations were made for high energy neutrons based on fission fragment tracks generated by fission foils at different shielding depths. A simple 1-D slab geometry was used in the calculations. Agreement between measurements and calculations depended on both shielding depth and threshold energy of the fission foils. Differences increased as both shielding and threshold energy increased. The modeled proton/neutron spectra appeared deficient at high energies. A 3-D model of the experiments is needed to help resolve the differences.

LDEF Project↗

Measured Thermal and Fast Neutron Fluence Rates ATR Cycles 171A ATF (Rev. 1)

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 171A ATF which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains fluence rate values corresponding to the particular elevations (relative to the 80-ft. core elevation) where the measurements were taken. The data in this report consists of (1) a table of the ATR power history and distribution, (2) a listing of the calculated thermal and fast neutron fluence rates, and (3) plots of calculated both the thermal and fast neutron fluence rates. The fluence rates reported are for the average power levels given in the table of power history and distribution. During the irradiation of Cycle 152A, the RML performed additional flux measurements to assess core reconfiguration issues. Measurements using cadmium covered as well as bare neutron monitors in the Southwest, Southeast, and H positions of the Center lobe were performed to determine the division in neutron energy between epithermal and thermal neutrons. This is defined as the resonance correction defined in this report. It is used to quantify both thermal and fast neutron flux. For more information please refer to letter, “RADIATION MEASUREMENTS LABORATORY MEASUREMENTS OF IN CORE ATR PHYSICS TESTING DURING CYCLE 152A” dated January 24, 2013, to Casey Stengel from C. C. Jensen. The measured values documented in RML Procedure, “ACMM-3600, Flux Monitoring,” will be used indefinitely until further measurements supersede the current values.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measured Thermal and Fast Neutron Fluence Rates ATR Cycles 171A IR TMIST 3B

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 171A which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains fluence rate values corresponding to the particular elevations (relative to the 80-ft. core elevation) where the measurements were taken. The data in this report consists of (1) a table of the ATR power history and distribution, (2) a listing of the calculated thermal and fast neutron fluence rates, and (3) plots of calculated both the thermal and fast neutron fluence rates. The fluence rates reported are for the average power levels given in the table of power history and distribution. During the irradiation of Cycle 152A, the RML performed additional flux measurements to assess core reconfiguration issues. Measurements using cadmium covered as well as bare neutron monitors in the Southwest, Southeast, and H positions of the Center lobe were performed to determine the division in neutron energy between epithermal and thermal neutrons. This is defined as the resonance correction defined in this report. It is used to quantify both thermal and fast neutron flux. For more information please refer to letter, “RADIATION MEASUREMENTS LABORATORY MEASUREMENTS OF IN CORE ATR PHYSICS TESTING DURING CYCLE 152A” dated January 24, 2013, to Casey Stengel from C. C. Jensen. The measured values documented in RML Procedure, “ACMM-3600, Flux Monitoring,” will be used indefinitely until further measurements supersede the current values.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measured Thermal and Fast Neutron Fluence Rates ATR Cycles 171A AFC (Rev. 1)

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 171A AFC which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains fluence rate values corresponding to the particular elevations (relative to the 80-ft. core elevation) where the measurements were taken. The data in this report consists of (1) a table of the ATR power history and distribution, (2) a listing of the calculated thermal and fast neutron fluence rates, and (3) plots of calculated both the thermal and fast neutron fluence rates.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Revealing the chemical environment of Cr, Fe, and Ni in high temperature-ultrafine precipitate strengthened steel subjected to low fluence neutron irradiation

High-temperature ultrafine-precipitate-strengthened (HT-UPS) steel has potential applications in advanced nuclear reactors as a structural material. However, little is currently known about its response to neutron irradiation. This research provides insight into the neutron irradiation-induced physicochemical changes of the major constituents in HT-UPS steels, including Fe, Cr, and Ni, using synchrotron X-ray absorption near edge structure (XANES) and diffraction. This study is the first known investigation using XANES to characterize HT-UPS steel to analyze the evolution of the atomic level chemistry. It was found that following irradiation, nucleation, ballistic dispersion, and/or coarsening of Cr 23 C 6 precipitates occurred at very low neutron irradiation fluences, from 0.003 displacements per atom (dpa) up to 0.3 dpa, at ~600°C, which were at least an order of magnitude lower than previous studies. Calculations of the angular momentum projections, partial density of states, and the XANES spectra confirmed the experimental findings of the Cr 23 C 6 precipitate evolution. In contrast, the local atomic structure around Fe and Ni atoms demonstrated irradiation resistance.

36 MATERIALS SCIENCE↗

Neutron Fluence and Kerma Responses to Bare, Steel-Reflected, and Lucite-Reflected Steady-State Operations of the ORNL Health Physics Research Reactor

The experiments evaluated in this report were conducted at the Health Physics Research Reactor (HPRR), also known as the Fast Burst Reactor. The reactor was designed and built at Oak Ridge National Laboratory (ORNL) in 1961. In this evaluation, a total of 12 experiments were evaluated (6 shield configurations and two responses). Six of them are considered acceptable as benchmark experiments and are thoroughly described: the measurands are bare, steel-shielded and Lucite-shielded neutron fluences and neutron KERMA responses to steady-state operations of the HPRR. It is important to mention that there is a general lack of information in the experimental methodology and neutron spectrum unfolding, and in some cases, unexpected and unexplained discrepancies between calculation and experiment. The HPRR’s unique characteristics were that it is a fast reactor, the use of a Lucite shield as the shielding material, and the use of the neutron fluence as the main benchmark measurand. There are no known, significant correlations between benchmarks in this evaluation and benchmarks in other evaluations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A neutron fluence map of the Los Alamos National Laboratory Godiva IV critical assembly

A neutron fluence map and a total ionizing dose map of the Los Alamos National Laboratory Godiva IV fast burst critical assembly was generated using passive reactor dosimetry, comprised of sulfur pellets and thermoluminescent dosimeters. Godiva IV is an unmoderated, fast burst, critical assembly constructed of approximately 65 kg of highly enriched uranium fuel alloyed with 1.5 % molybdenum for strength. The mapping was performed during a single 75.6 ºC temperature rise burst operation, with the top and sides of the cylindrical Godiva-IV Top Hat covered in passive dosimetry. Dosimetry was placed in a symmetric pattern around the Top Hat, with higher concentrations near the control rods and burst rod. A specific portion of the lower quadrant of the burst rod was mapped to confirm a testing region where the neutron fluence varied by no more than ± 5%. The results will be used to assess the neutron, gamma, and total ionizing dose environment in three-dimensional space around the assembly for higher fidelity experiment placement, active dosimetry positioning, and radiation field characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lunar Nuclear Reactor Neutron Fluence and Gamma Dose Estimates

NASA aims to deploy a fission reactor on the lunar surface by 2030 to generate 100 kWe of power for at least 10 years without maintenance or refueling. To assess system and subsystem survivability according to those requirements, a model of the reactor pallet was created in the radiation transport code MCNP to determine the neutron fluences and gamma doses that the materials and systems would be exposed to. The model was based on the 2025 government design. The model indicated that the control drum motors, Brayton cycle engines, and pipes and valves would be exposed to neutron fluences of 1×10 15 – 1×10 16 n/cm 2 per year and gamma doses ranging from 10 to 500 Mrad per year. The electronics box housing the instrumentation and control elements is expected to receive 1×10 14 – 1×10 15 n/cm 2 per year and gamma doses in the range of 1–5 Mrad per year. These doses necessitate that the control drum motors, Brayton cycle engines, valve components, control electronics, and other components be radiation-hardened (>10 16 n/cm 2 and >10 Mrad gamma dose) or additionally shielded to survive the 10-year lunar mission.

Radiation-Hardened Materials↗