Search NASA⌕ Search

SEARCH · Search NASA

Results for “NICKEL 61”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A new insight into neutrino energy loss by electron capture of iron group nuclei in magnetar surfaces

Based on the relativistic mean-field effective interactions theory, and the Lai dong model, we discuss the influences of superstrong magnetic fields (SMFs) on electron Fermi energy, nuclear blinding energy, and single-particle level structure in magnetar surfaces. Using the Shell-Model Monte Carlo method and the Random Phase Approximation theory, we analyze the neutrino energy loss rates (NELRs) by electron capture for iron group nuclei in SMFs. First, when B {sub 12} < 100, we find that the SMFs have a slight influence on the NELRs for most nuclides at relativistic low temperatures (e.g., T {sub 9} = 0.233); nevertheless, the NELRs increase by more than four orders of magnitude at relativistic high temperatures (e.g., T {sub 9} = 15.53). When B {sub 12} > 100, the NELRs decrease by more than three orders of magnitude (e.g., at T {sub 9} = 15.53 for {sup 52–61}Fe, {sup 55–60}Co, and {sup 56–63}Ni). Second, for a certain value of magnetic field and temperature, the NELRs increase by more than four orders of magnitude when ρ{sub 7}⩽10{sup 3}, but as the density increases (i.e., when ρ{sub 7}>10{sup 3}), there is almost no influence on the density of NELRs. For the density around ρ{sub 7}=10{sup 2}, there is an abrupt increase in NELRs when B {sub 12} ≥ 10{sup 3.5}. Such jumps are an indication that the underlying shell structure has changed due to single-particle behavior by SMFs. Finally, we compare our NELRs with those of Fuller et al. (FFN) and Nabi and Klapdor-Kleingrothaus (NKK). For the case without SMFs, one finds that our rates for certain nuclei are close to about five orders of magnitude lower than FFN and NKK at relativistic low temperatures (e.g., T {sub 9} = 1). However, at a relativistic high temperature (e.g., T {sub 9} = 3), our results are in good agreement with NKK, but about one order of magnitude lower than FFN. For the case with SMFs, our NELRs for some iron group nuclei can be about five orders of magnitude higher than those of FFN and NKK. (Note that B {sub 12}, T {sub 9}, and ρ {sub 7} are in units of 10{sup 12} G, 10{sup 9} K, and 10{sup 7} g cm{sup −3}, respectively.)

79 ASTRONOMY AND ASTROPHYSICS↗

Real-time algorithm for robust coincidence search

In in-beam {gamma}-ray spectroscopy experiments, we often look for coincident detection events. Among every N events detected, coincidence search is naively of principal complexity O(N{sup 2}). When we limit the approximate width of the coincidence search window, the complexity can be reduced to O(N), permitting the implementation of the algorithm into real-time measurements, carried out indefinitely. We have built an algorithm to find simultaneous events between two detection channels. The algorithm was tested in an experiment where coincidences between X and {gamma} rays detected in two HPGe detectors were observed in the decay of {sup 61}Cu. Functioning of the algorithm was validated by comparing calculated experimental branching ratio for EC decay and theoretical calculation for 3 selected {gamma}-ray energies for {sup 61}Cu decay. Our research opened a question on the validity of the adopted value of total angular momentum of the 656 keV state (J{sup {pi}} = 1/2{sup -}) in {sup 61}Ni.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Routine production of copper-64 using 11.7MeV protons

Reliable production of copper-64 ({sup 64}Cu) was achieved by irradiating enriched nickel-64 ({sup 64}Ni, >94.8%) in an IBA 18/9 cyclotron. Nickel-64 (19.1 {+-} 3.0 mg) was electroplated onto an Au disc (125{mu}m Multiplication-Sign 15mm). Targets were irradiated with 11.7 MeV protons for 2 hours at 40{mu}A. Copper isotopes ({sup 60,61,62,64}Cu) were separated from target nickel and cobalt isotopes ({sup 55,57,61}Co) using a single ion exchange column, eluted with varying concentration of low HCl alcohol solutions. The {sup 64}Ni target material was recovered and reused. The {sup 64}Cu production rate was 1.46{+-}0.3MBq/{mu}A.hr/mg{sup 64}Ni(n = 10) (with a maximum of 2.6GBq of {sup 64}Cu isolated after 2hr irradiation at 40uA. Radionuclidic purity of the {sup 64}Cu was 98.7 {+-} 1.6 % at end of separation. Cu content was < 6mg/L (n = 21). The specific activity of {sup 64}Cu was determined by ICP-MS and by titration with Diamsar to be 28.9{+-}13.0GBq/{mu}mol[0.70{+-}0.35Ci/{mu}mol]/({mu}A.hr/mg{sup 64}Ni)(n = 10) and 13.1{+-}12.0GBq/{mu}mol[0.35{+-}0.32Ci/{mu}mol]/({mu}A.hr/mg{sup 64}Ni)(n 9), respectively; which are in agreement, however, further work is required.

07 ISOTOPE AND RADIATION SOURCES↗

Precision measurement of relative γ-ray intensities from the decay of 61Cu

A discrepancy, well outside reported uncertainties, has been observed between the accepted and measured values of the intensity ratio of the two strongest γ-ray following 61 Cu β + decay. This discrepancy has significant impact since the nat Ni(d,x) 61 Cu reaction has historically been one of only a few IAEA recommendations for use as a deuteron flux monitor and a considerable number of published cross sections measured in ratio to that beam monitor cross section may depend on the choice of either the first or second strongest ray in those calculations. To determine the magnitude of this error most precisely, over a hundred separate measurements of the 283 keV to 656 keV γ-ray emission ratio were collected from seven experiments and a variety of detectors and detection geometries. A weighted average of all these measurements indicates an error in the value listed in the Nuclear Data Sheets of 11% in either the primary or second-highest intensity γ-ray of 61 Cu, potentially introducing an 11% error in 61 Cu production cross section measurements, cross sections using nickel activation as a deuteron beam current monitor, or in dose rates when 61 Cu is used in nuclear medicine. General agreement with the Data Sheets with ten other intensity ratios suggests the most probable error is in the secondary (656 keV) emission, which accordingly should be updated from 10.8% to 9.69%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The alloy undercooling experiment on the Columbia STA 61-C space shuttle mission

An Alloy Undercooling experiment was performed in an electromagnetic levitator during the Columbia STS 61-C mission in January 1986. One eutectic nickel-tin alloy specimen was partially processed before an equipment failure terminated the experiment. Examination of the specimen showed evidence of undercooling and some unusual microstructural features.

Harf, Fredric H.↗

The alloy undercooling experiment on the Columbia STS 61-C Space Shuttle mission

An Alloy Undercooling experiment was performed in an electromagnetic levitator during the Columbia STS 61-C mission in January 1986. One eutectic nickel-tin alloy specimen was partially processed before an equipment failure terminated the experiment. Examination of the specimen showed evidence of undercooling and some unusual microstructural features.

Harf, Fredric H.↗

Iron and nickel isotope compositions of presolar silicon carbide grains from supernovae

Here we report the carbon, silicon, iron, and nickel isotope compositions of twenty-five presolar SiC grains of mostly supernova (SN) origin. The iron and nickel isotope compositions were measured with the new Chicago Instrument for Laser Ionization, CHILI, which allows the analysis of all iron and nickel isotopes without the isobaric interferences that plagued previous measurements with the NanoSIMS. Despite terrestrial iron and nickel contamination, significant isotopic anomalies in 54 Fe/ 56 Fe, 57 Fe/ 56 Fe, 60 Ni/ 58 Ni, 61 Ni/ 58 Ni, 62 Ni/ 58 Ni, and 64 Ni/ 58 Ni were detected in nine SN grains (of type X). Combined multi-isotope data of three grains with the largest nickel isotope anomalies (>100% or <-100% in at least one isotope ratio, when expressed as deviation from the solar value) are compared with the predictions of two SN models, one with and one without hydrogen ingestion in the He shell prior to SN explosion. One grain's carbon-silicon-iron-nickel isotope composition is consistent with the prediction of the model without hydrogen ingestion, whereas the other two grains' isotope anomalies could not be reproduced using either SN models. The discrepancies between the measured isotope compositions and model predictions may indicate element fractionation in the SN ejecta prior to or during grain condensation, and reiterate the need for three-dimensional SN models.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-FG-BRA-08: Potential Role of the Glycolytic Oscillator in Acute Hypoxia in Tumors

Purpose: Oscillatory dynamics in acute hypoxia have been observed, but poorly understood. They have mostly been attributed to vascular perturbations, but no link has yet been made to metabolic causes. We set out to determine the fundamental frequencies and test for coherence in tumor oxygen dynamics and spatial properties. Methods: Severe combined immunodeficient (SCID) mice were inoculated onto bilateral flanks with human derived head and neck carcinoma (UW-SCC22) cell line xenografts. Oxygen dynamics were monitored in the tumor every minute for an hour using three modalities: blood oxygen level dependent - magnetic resonance imaging (BOLD-MRI), hemoglobin oxygen saturation photoacoustic, and locally manufactured optical probes for spectral fitting. A statistical test was used to separate fluctuating from non-fluctuating voxels and pixels in BOLD-MRI and photoacoustic data respectively. The power spectrum density (PSD) and the autocorrelation functions were calculated for the time series of each voxel, pixel and region, of the BOLD-MRI, photoacoustic or fiber optic data respectively. Results: Using all three techniques, intermittent oxygen dynamics with both coherent and incoherent signatures was observed in the tumors. Upon averaging the PSDs of fluctuating voxels and pixels, it was found that these oscillations occurred with periods of minutes to tens of minutes from all three approaches. Observations from the BOLD-MRI and photoacoustic data showed that clusters of voxels oscillated in a synchronized manner. Conclusion: We were able to use three different modalities to show that fluctuation in tumor oxygen is both coherent and incoherent, with periods of minutes to tens of minutes. These periods are very similar to those from the well-established metabolic, non-linear biomechanical phenomenon called the glycolytic oscillator. This may provide an additional explanation to the cause of cyclic hypoxia. Such dynamics could have profound implications in hypofractionated radiotherapy regiments and could help guide treatment and make it more patient specific. The authors would like to thank the University of Wisconsin Carbone Cancer Center (UWCCC) for the funds to complete this project. This work is also supported in part by NIH/NCI P30 CA014520- UW Comprehensive Cancer Center Support”.

60 APPLIED LIFE SCIENCES↗

Electron screening in nickel

In order to further investigate electron screening phenomenon we studied proton induced nuclear reactions over an energy range from 1.35 to 3.08 MeV for different environments: Ni metal and NiO insulator. The measurements were based on observation of the {gamma}-ray yields of {sup 59,61,63,64,65}Cu and {sup 58,60,62}Ni. Also, we have studied the decay of {sup 61}Cu produced in the reaction {sup 60}Ni(p,{gamma}), in order to find a possible decay rate perturbation by atomic electrons and found a small difference in half-life for metallic compared to oxide environment, respectively. The present results clearly show that the metallic environment affects the fusion reactions at low energy and that it might also affect the decay rate.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cobalt-rich, nickel-poor metal (wairauite) in the Ningqiang carbonaceous chondrite

A structurally ordered cubic metal grain containing approximately 39 wt% Co, 61 wt% Fe, and less than 0.6 wt% Ni (approximately Fe3Co2) was found associated with troilite and pentlandite in the matrix of the Ningqiang carbonaceous chondrite. This mineral is similar to terrestrial wairauite. Experimental data in the Fe-Co system indicate that this CsCl-type Co-rich metal is stable below 700 C. Phase relations in the Fe-Co-Ni system show that Co cannot fractionate from Ni above 500 C. The dominant opaque minerals of awaruite, magnetite, and pentlandite in Ningqiang suggest relatively oxidizing conditions.

Xin, Hua↗

Electron screening in nickel

In order to investigate the interplay between nuclei and their surroundings we studied proton induced nuclear reactions over an energy range from 1.35 to 3.08 MeV for different environments: Ni metal and NiO insulator. The measurements were based on observation of the {gamma}-ray yields of {sup 59,61,63,64,65}Cu and {sup 58,60,62}Ni. The presented results clearly show that the metallic environment affects the fusion reactions at low energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of biquadratic coupling on current induced magnetization switching in Co/Cu/Ni-Fe nanopillar

The effect of biquadratic coupling on spin current induced magnetization switching in a Co/Cu/Ni-Fe nanopillar device is investigated by solving the free layer magnetization switching dynamics governed by the Landau-Lifshitz-Gilbert-Slonczewski (LLGS) equation. The LLGS equation is numerically solved by using Runge-Kutta fourth order procedure for an applied current density of 5 × 10{sup 12} Am{sup -2}. Presence of biquadratic coupling in the ferromagnetic layers reduces the magnetization switching time of the nanopillar device from 61 ps to 49 ps.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

SU-G-TeP3-10: Radiation Induces Prompt Live-Cell Metabolic Fluxes

Purpose: To compare metabolic dynamics and HIF-1α expression following radiation between a cancerous cell line (UM-SCC-22B) and a normal, immortalized cell line, NOK (Normal Oral Keratinocyte). HIF-1 is a key factor in metabolism and radiosensitivity. A better understanding of how radiation affects the interplay of metabolism and HIF-1 might give a better understanding of the mechanisms responsible for radiosensitivity. Methods: Changes in cellular metabolism in response to radiation are tracked by fluorescence lifetime of NADH. Expression of HIF-1α was measured by immunofluorescence for both cell lines with and without irradiation. Radiation response is also monitored with additional treatment of a HIF-1α inhibitor (chrysin) as well as a radical scavenger (glutathione). Changes in oxygen consumption and respiratory capacity are also monitored using the Seahorse XF analyzer. Results: An increase in HIF-1α was found to be in response to radiation for the cancer cell line, but not the normal cell line. Radiation was found to shift metabolism toward glycolytic pathways in cancer cells as measured by oxygen consumption and respiratory capacity. Radiation response was found to be muted by addition of glutathione to cell media. HIF-1α inhibition similarly muted radiation response in cancer. Conclusion: The HIF-1 protein complex is a key regulator cellular metabolism through the regulation of glycolysis and glucose transport enzymes. Moreover, HIF-1 has shown radio-protective effects in tumor vascular endothelia, and has been implicated in metastatic aggression. Monitoring interplay between metabolism and the HIF-1 protein complex can give a more fundamental understanding of radiotherapy response.

60 APPLIED LIFE SCIENCES↗

Iso standardization of theoretical activity evaluation method for low and intermediate level activated waste generated at nuclear power plants

Disposal of low-and intermediate-level activated waste generated at nuclear power plants is being planned or carried out in many countries. The radioactivity concentrations and/or total quantities of long-lived, difficult-to-measure nuclides (DTM nuclides), such as C-14, Ni-63, Nb-94, α emitting nuclides etc., are often restricted by the safety case for a final repository as determined by each country's safety regulations, and these concentrations or amounts are required to be known and declared. With respect to waste contaminated by contact with process water, the Scaling Factor method (SF method), which is empirically based on sampling and analysis data, has been applied as an important method for determining concentrations of DTM nuclides. This method was standardized by the International Organization for Standardization (ISO) and published in 2007 as ISO21238 'Scaling factor method to determine the radioactivity of low and intermediate-level radioactive waste packages generated at nuclear power plants' [1]. However, for activated metal waste with comparatively high concentrations of radioactivity, such as may be found in reactor control rods and internal structures, direct sampling and radiochemical analysis methods to evaluate the DTM nuclides are limited by access to the material and potentially high personnel radiation exposure. In this case, theoretical calculation methods in combination with empirical methods based on remote radiation surveys need to be used to best advantage for determining the disposal inventory of DTM nuclides while minimizing exposure to radiation workers. Pursuant to this objective a standard for the theoretical evaluation of the radioactivity concentration of DTM nuclides in activated waste, is in process through ISO TC85/SC5 (ISO Technical Committee 85: Nuclear energy, nuclear technologies, and radiological protection; Subcommittee 5: Nuclear fuel cycle). The project team for this ISO standard was formed in 2011 and is composed of experts from 11 countries. The project team has been conducting technical discussions on theoretical methods for determining concentrations of radioactivity, and has developed the draft International Standard of ISO16966 'Theoretical activation calculation method to evaluate the radioactivity of activated waste generated at nuclear reactors' [2]. This paper describes the international standardization process developed by the ISO project team, and outlines the following two theoretical activity evaluation methods:? Point method? Range method. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of hafnium configuration of FLUOLE-2 program - 25409

The purpose of this paper is to present an analysis of the hafnium configuration of FLUOLE-2 program. FLUOLE-2 is a set of benchmark-type experiments dedicated to neutron attenuation analysis with the aim of improving the TRIPOLI-4{sup R} Monte Carlo code validation and industrial neutron physics scheme. The CEA developed this program, with the support of EDF, in order to be representative of 900 and 1450 MWe Pressurized Water Reactors operated in France. For that purpose, different stainless steel structures have been designed and appropriately positioned inside the EOLE facility located at Cadarache CEA center. EOLE is a pool type zero power reactor, composed of a cylindrical aluminum vessel with an over-structure of stainless steel, that is able to contain various types of core and related structures. The FLUOLE-2 core has been designed as a 29 x 29 pins square lattice of fuel rods. Different kind of dosimeters (cobalt, gold, tin, rhodium, indium, iron, nickel, titanium, aluminum, and vanadium) were irradiated inside and outside the core. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improving the Ni I atomic model for solar and stellar atmospheric models

Neutral nickel (Ni I) is abundant in the solar atmosphere and is one of the important elements that contribute to the emission and absorption of radiation in the spectral range between 1900 and 3900 Å. Previously, the Solar Radiation Physical Modeling (SRPM) models of the solar atmosphere only considered a few levels of this species. Here, we improve the Ni I atomic model by taking into account 61 levels and 490 spectral lines. We compute the populations of these levels in full NLTE using the SRPM code and compare the resulting emerging spectrum with observations. The present atomic model significantly improves the calculation of the solar spectral irradiance at near-UV wavelengths, which is important for Earth atmospheric studies, and particularly for ozone chemistry.

79 ASTRONOMY AND ASTROPHYSICS↗

The effect of oxygen flow rate and radio frequency plasma power on cubic ZnMgO ultraviolet sensors grown by plasma-enhanced molecular beam epitaxy

Cubic Zn{sub 1-x}Mg{sub x}O thin films were produced by Plasma-Enhanced Molecular Beam Epitaxy. Oxygen flow rate and applied Radio-Frequency (RF) plasma power were varied to investigate the impact on film growth and optoelectronic device performance. Solar-blind and visible-blind detectors were fabricated with metal-semiconductor-metal interdigitated Ni/Mg/Au contacts and responsivity is compared under different growth conditions. Increasing oxygen flow rate and RF plasma power increased Zn incorporation in the film, which leads to phase segregation at relatively high Zn/Mg ratio. Responsivity as high as 61 A/W was measured in phase-segregated ZnMgO visible-blind detectors.

36 MATERIALS SCIENCE↗

Cation distribution in Ni{sub 1−x}Zn{sub x}Fe{sub 2}O{sub 4} using X-ray absorption spectroscopy

Spinel ferrite samples of Ni{sub 1−x}Zn{sub x}Fe{sub 2}O{sub 4} (for x=0.2, 0.4, 0.5, 0.6 and 0.8) nanoparticles prepared by a novel chemical synthesis method have been characterized by X-ray Absorption Spectroscopy (XAS) technique to investigate the distribution of cations in the unit cell. XANES region clearly shows that as Ni concentration increases, the pre-edge feature, which is a characteristic of tetrahedral coordination of Fe, is enhanced. A quantitative determination of the relative occupancy of iron cation in the octahedral and tetrahedral sites of the spinel structure was obtained from EXAFS data analysis. It has been found that as atomic fraction of Ni is increased from 0.2 to 0.8, Fe occupancy at tetrahedral to octahedral sites is increased from 13:87 and to 39:61.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗