Search NASA⌕ Search

SEARCH · Search NASA

Results for “NIOSH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Visualizing the NIOSH Pocket Guide: Open-source web application for accessing and exploring the NIOSH Pocket Guide to Chemical Hazards

The NIOSH Pocket Guide to Chemical Hazards is a trusted resource that displays key information for a collection of chemicals commonly encountered in the workplace. Entries contain chemical structures—occupational exposure limit information ranging from limits based on full-shift time-weighted averages to acute limits such as short-term exposure limits and immediately dangerous to life or health values, as well as a variety of other data such as chemical-physical properties and symptoms of exposure. The NIOSH Pocket Guide (NPG) is available as a printed, hardcopy book, a PDF version, an electronic database, and a downloadable application for mobile phones. All formats of the NIOSH Pocket Guide allow users to access the data for each chemical separately, however, the guide does not support data analytics or visualization across chemicals. This project reformatted existing data in the NPG to make it searchable and compatible with exploration and analysis using a web application. The resulting application allows users to investigate the relationships between occupational exposure limits, the range and distribution of occupational exposure limits, and the specialized sorting of chemicals by health endpoint or to summarize information of particular interest. These tasks would have previously required manual extraction of the data and analysis. The usability of this application was evaluated among industrial hygienists and researchers and while the existing application seems most relevant to researchers, the open-source code and data are amenable to modification by users to increase customization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

National Institute of Occupational Safety and Health (NIOSH) Partnered Development of Cryogenic Life Support Technologies

Cryogenic life support technology, used by NASA to protect crews working around hazardous gases soon could be called on for a number of life-saving applications as well as the agency's new human spaceflight endeavors. This technology under development in Kennedy Space Center's Biomedical Laboratory has the potential to store more than twice the amount of breathable air than traditional compressed gas systems. The National Institute for Occupational Safety and Health (NIOSH) is contributing to the funding for this project in the hopes that the liquid air-based systems could change the way workers dependent on life support technologies accomplish their mission, improving their safety and efficiency.

NIOSH↗

OSHA medical and workplace surveillance requirements and NIOSH recommendations (for employees exposed to toxic substances and other work hazards)

Both OSHA medical and work place surveillance requirements and NIOSH recommendations were prepared as a desk reference to help occupational health professionals to perform their duties. The medical surveillance information focuses on frequency of physical examinations, specific problems that may arise as a result of exposure (e.g., decreased immunocompetence, weight loss, ets.), conditions that intensify the harmful effects of exposure (e.g., medication an exposed employee may be taking, cigarette smoking, etc.), the areas that should be scrutinized in medical and work histories and during the physical exam, and specific clinical tests that should be conducted. Recordkeeping requirements are also specified. The workplace surveillance information consists of monitoring requirements, personal protective equipment requirements, and recordkeeping requirements. Such details as the sampling devices that should be used, the type of respirators that should be worn, and the frequency of inspections are included. This document does not specify the training, labeling and posting, and safe work practice requirements and recommendations due to space considerations.

Cooper, L. P.↗

Filtration Performance Results: Sierra Peaks Material No. 4

Sandia National Laboratories (SNL) assessed the filtration performance of materials from Sierra Peaks to identify alternatives which may perform similarly to materials used in FDA-approved N95 respirators. This work is meant to characterize the aerosol performance of materials to give Sierra Peaks information for them to determine if they elect to submit masks made using these materials for follow-on N95 certification testing at an accredited facility. The R&D testbed used is a large-scale filtration system designed to test commercial filter boxes. System modifications were performed to simulate, where possible, parameters defined by the National Institute for Occupational Safety and Health (NIOSH) for certification of filter materials for N95 respirators (NIOSH 2019). The system is a pull-through design. Air enters through a Laminar Flow Element (LFE) and the volumetric flow is measured based on the pressure drop across the LFE. Pressure is measured via a Pressure Transducer (PT). The air then passes through a High Efficiency Particulate Air (HEPA) filter to purge the air of ambient airborne particulates. Test aerosol is injected into the flow shortly after and mixing is induced via a coarse mesh. The airflow is allowed to fully develop prior to arriving at the test section. The aerosol then passes through the test material mounted in a box in the test section. Pressure drop across the test article is measured and aerosol sampling probes measure the aerosol concentrations upstream and downstream of the sample. The air passes through a second HEPA filter prior to being exhausted to ambient by a blower. A Topas aerosol generator is used to produce the test aerosol from Sodium Chloride (NaC1) dissolved in deionized (DI) water. Generated aerosol passes through a heated mixing chamber and a desiccant dryer to produce nanosized solid-state particulates. A dilution loop allows for the aerosol concentration to be regulated. The aerosol sampling probes upstream and downstream of the test section are aligned with the flow path. These are ducted directly to the aerosol sizing and counting instruments. A Laser Aerosol Spectrometer (LAS) was used for data collection in the original configuration of the system and was also used for initial testing in this project. Because the lower measurement range for the LAS is 90 nanometers (nm), the LAS was switched out for a more complicated Scanning Mobility Particle Sizer (SMPS) spectrometer system. The SMPS is comprised of an Electrostatic Classifier (EC), Differential Mobility Analyzer (DMA), and a Condensation Particle Counter (CPC). This enabled data collection at 75 nm, the particle size called out in the NIOSH guidelines.

36 MATERIALS SCIENCE↗

A Parameterization Study of Sew-EZ Materials: Types #6 and #8

Two material types identified by Sew-EZ were tested in various configurations, and under various conditions, by Sandia National Laboratories (SNL). The primary focus of this study was to assess the filtration performance of these two materials and identify if they perform similarly to certified N95 respirators. Testing was conducted on two systems which use distinctly different techniques to characterize the aerosol penetration characteristics of materials: a) R&D Filtration System: A large-scale R&D filtration system was used with testing parameters that mimicked NIOSH guidelines, where possible. Efficiency data as a function of particle size was attained using NaC1 as the test aerosol and a Scanning Mobility Particle Sizer (SMPS) for measurements. A more detailed system description can be found in Omana et al. 2020. b) Automated Tester: A commercial, automated filter tester (100Xs, Air Techniques International) was used to provide penetration/efficiency data for Sew EZ materials. The 100Xs aerosolizes a polydisperse NaC1 aerosol with a consistent concentration and size profile. The 100Xs manual (Air Techniques International 2018) states, "The aerosol particle size and distribution are designed to meet all requirements as defined in the relevant sections of NIOSH 42 CFR, Part 84 (pg. 32)."

36 MATERIALS SCIENCE↗

Technical Assistance for Characterization Studies of Personal Protection Equipment (PPE) (Final CTAP Report)

Sandia National Laboratories (SNL) conducted an independent assessment of three different certified N95 respirators for the State of New Mexico Department of Homeland Security and Emergency Management. The testing conducted under this effort mimicked traditional NIOSH certification testing methodologies, where possible (NIOSH 2019). This included the use of a commercially available off-the-shelf (COTS) instrument typically used in industry for N95 respirator certification (ATI 2018). The COTS system, an Air Techniques International 100Xs automated filter tester, was used for all the testing reported in this document. It is important to note that SNL is NOT a certification laboratory, and all quantitative results are for informational purposes only. Additional technical information of N95-related efforts conducted by this team may be found in: Omana et al. (2020a), Omana et al. (2020b), Celina et al. (2020)

42 ENGINEERING↗

Passive, Direct-Read Monitoring System for Selective Detection and Quantification of Hydrogen Chloride

Monitoring the exposure of an employee to hydrogen chloride or hydrochloric acid in the presence of other acids has been a challenge to the industrial hygiene community. The capability of a device to differentiate the levels of acid vapors would allow for more accurate determinations of exposure and therefore improved occupational health. In this work, a selective direct-read colorimetric badge system was validated for Short Term Exposure Limit (STEL) monitoring of hydrogen chloride. The passive colorimetric badge system consists of a direct reading badge and a color scale. The badge has a coated indicator layer with a diffusive resistance in the shape of an exclamation mark. An exclamation mark will appear if hydrogen chloride is present in the atmosphere at concentrations at or above 2.0 ppm. By using the color scale, the intensity of the color formed on the badge can be further quantified up to 25 ppm. The system was validated according to a protocol based on the NIOSH Protocol for the Evaluation of Passive Monitors. The badge was exposed to relative humidities ranging from 11% to 92%, temperatures ranging from 7 C to 400 C and air velocities ranging from 5 cm/sec to 170 cm/sec. All experiments were conducted in a laboratory vapor generation system. Hydrofluoric acid, nitric acid, sulfuric acid, chlorine, hydrogen sulfide and organic acids showed no effect on the performance of the hydrogen chloride monitoring system. The passive badge and color scale system exceeded the accuracy requirements as defined by NIOSH. At ambient conditions, the mean coefficient of variation was 10.86 and the mean bias was 1.3%. This data was presented previously at the American Industrial Hygiene Conference and Exposition in Toronto, Canada in June 1999.

Chapman, K. B.↗

Modeling Respiratory Toxicity of Authentic Lunar Dust

The lunar expeditions of the Apollo operations from the 60 s and early 70 s have generated awareness about lunar dust exposures and their implication towards future lunar explorations. Critical analyses on the reports from the Apollo crew members suggest that lunar dust is a mild respiratory and ocular irritant. Currently, NASA s space toxicology group is functioning with the Lunar Airborne Dust Toxicity Assessment Group (LADTAG) and the National Institute for Occupational Safety and Health (NIOSH) to investigate and examine toxic effects to the respiratory system of rats in order to establish permissible exposure levels (PELs) for human exposure to lunar dust. In collaboration with the space toxicology group, LADTAG and NIOSH the goal of the present research is to analyze dose-response curves from rat exposures seven and twenty-eight days after intrapharyngeal instillations, and model the response using BenchMark Dose Software (BMDS) from the Environmental Protection Agency (EPA). Via this analysis, the relative toxicities of three types of Apollo 14 lunar dust samples and two control dust samples, titanium dioxide (TiO2) and quartz will be determined. This will be executed for several toxicity endpoints such as cell counts and biochemical markers in bronchoaveolar lavage fluid (BALF) harvested from the rats.

Santana, Patricia A.↗

Translating nanoparticle dosimetry from conventional in vitro systems to occupational inhalation exposures

As encouraged by Toxicity Testing in the 21st Century, researchers increasingly apply high-throughput in vitro approaches to identify and characterize nanoparticle hazards, including conventional aqueous cell culture systems to assess respiratory hazards. Translating nanoparticle dose from conventional toxicity testing systems to relevant human exposures remains a major challenge for assessing occupational risk of nanoparticle exposures. Here, we explored existing computational tools and data available to translate nanoparticle dose metrics from cellular test systems to inhalation exposures of silver nanoparticles in humans. We used the Multiple-Path Particle Dosimetry (MPPD) Model to predict deposition of humans exposed to 20 and 110 nm silver nanoparticles at 0.9 µg/m3 over an 8 hr period, the proposed a National Institute of Occupational Safety and Health (NIOSH) recommended exposure limit (REL). MPPD predicts 1.88 and 0.98 µg of silver deposited in an 8 hr period for 20 and 110 nm nanoparticles, respectively, with 20 nm particles displaying nearly 11-fold higher total surface area deposited. Peak nanoparticle concentrations occurred more proximal in the pulmonary tract compared to mass deposition patterns (generation 5 vs. generations 20-21, respectively) due to regional differences in lung lining fluid volumes. Assuming 0.4% nanoparticle dissolution by mass as previously measured, we predict peak concentrations of silver ions in cells of 0.24 and 0.17 µg/mL for 20 and 110 nm particles, respectively. Both predicted concentrations are below the measured toxic threshold of 1.7 µg/mL of silver ions in cells from in vitro assessments. Assuming 4% dissolution by mass, we predict 10-fold higher silver concentrations in tissues, peaking at 2.4 and 1.7 µg/mL, for 20 and 110 nm nanoparticles respectively, exceeding the observed in vitro toxic threshold and highlighting the importance and sensitivity of dissolution rates. Overall, this approach offers a framework for extrapolating nanotoxicity results from in vitro cell culture systems to human exposures. Aligning appropriate dose metrics from in vitro and in vivo hazard characterizations and human pulmonary doses from occupational exposures are critical components for successful nanoparticle risk assessment and worker protection and provide guidance for designing future in vitro studies aimed at relevant human exposures.

Smith, Jordan N.↗

Detection of Airborne Influenza A and SARS-CoV-2 Virus Shedding following Ocular Inoculation of Ferrets

Despite reports of confirmed human infection following ocular exposure with both influenza A virus (IAV) and SARS-CoV-2, the dynamics of virus spread throughout oculonasal tissues and the relative capacity of virus transmission following ocular inoculation remain poorly understood. Furthermore, the impact of exposure route on subsequent release of airborne viral particles into the air has not been examined previously. To assess this, ferrets were inoculated by the ocular route with A(H1N1)pdm09 and A(H7N9) IAVs and two SARS-CoV-2 (early pandemic Washington/1 and Delta variant) viruses. Virus replication was assessed in both respiratory and ocular specimens, and transmission was evaluated in direct contact or respiratory droplet settings. Viral RNA in aerosols shed by inoculated ferrets was quantified with a two-stage cyclone aerosol sampler (National Institute for Occupational Safety and Health [NIOSH]). All IAV and SARS-CoV-2 viruses mounted a productive and transmissible infection in ferrets following ocular inoculation, with peak viral titers and release of virus-laden aerosols from ferrets indistinguishable from those from ferrets inoculated by previously characterized intranasal inoculation methods. Viral RNA was detected in ferret conjunctival washes from all viruses examined, though infectious virus in this specimen was recovered only following IAV inoculation. Low-dose ocular-only aerosol exposure or inhalation aerosol exposure of ferrets to IAV similarly led to productive infection of ferrets and shedding of aerosolized virus. Viral evolution during infection was comparable between all inoculation routes examined. Furthermore, these data support that both IAV and SARS-CoV-2 can establish a high-titer mammalian infection following ocular exposure that is associated with rapid detection of virus-laden aerosols shed by inoculated animals.

60 APPLIED LIFE SCIENCES↗

COVID-19 global pandemic planning: Performance and electret charge of N95 respirators after recommended decontamination methods

Shortages of N95 respirators for use by medical personnel have driven consideration of novel conservation strategies, including decontamination for reuse and extended use. Decontamination methods listed as promising by the Centers for Disease Control and Prevention (CDC) (vaporous hydrogen peroxide (VHP), wet heat, ultraviolet irradiation (UVI)) and several methods considered for low resource environments (bleach, isopropyl alcohol and detergent/soap) were studied for two commonly used surgical N95 respirators (3M™ 1860 and 1870+ Aura™). Although N95 filtration performance depends on the electrostatically charged electret filtration layer, the impact of decontamination on this layer is largely unexplored. As such, respirator performance following decontamination was assessed based on the fit, filtration efficiency, and pressure drop, along with the relationship between (1) surface charge of the electret layer, and (2) elastic properties of the straps. Decontamination with VHP, wet heat, UVI, and bleach did not degrade fit and filtration performance or electret charge. Isopropyl alcohol and soap significantly degraded fit, filtration performance, and electret charge. Pressure drop across the respirators was unchanged. Modest degradation of N95 strap elasticity was observed in mechanical fatigue testing, a model for repeated donnings and doffings. CDC recommended decontamination methods including VHP, wet heat, and UV light did not degrade N95 respirator fit or filtration performance in these tests. Extended use of N95 respirators may degrade strap elasticity, but a loss of face seal integrity should be apparent during user seal checks. NIOSH recommends performing user seal checks after every donning to detect loss of appropriate fit. Decontamination methods which degrade electret charge such as alcohols or detergents should not be used on N95 respirators. The loss of N95 performance due to electret degradation would not be apparent to a respirator user or evident during a negative pressure user seal check.

60 APPLIED LIFE SCIENCES↗

Supercritical CO2 sterilization of N95 Masks

A preliminary investigation of the use of supercritical carbon dioxide for treating of 3M 1860 N95 masks was undertaken to evaluate a potential route to low-cost, scalable, sterilization of personal protective equipment for multiple reuse in hospital settings. Upon entering the supercritical regime, the normally distinct liquid and gaseous phases of CO 2 merge into a single homogeneous phase that has density, short-range order, and solvation capacity of a liquid, but the volume-filling and permeation properties that of a gas. This enables supercritical CO2 to function as a vehicle for delivery of biocidal agents such peracetic acid into microporous structures. The potentially adverse effect of a liquid-to-gas phase transition on mask filter media is avoided by conducting cleaning operations above 31 C, the critical temperature for carbon dioxide. A sample of fifteen 3M 1860 N95 masks was subjected to ten consecutive cycles of supercritical CO 2 cleaning to determine its effect on mask performance. These 15 masks, along with 5 control samples then underwent a battery of standardized tests at the CDC NIOSH NPPTL research facility in Pittsburgh, PA. The data from these tests strongly suggest (but do not prove) that supercritical carbon dioxide do not damage 3M 1860 N95 masks. Additional tests conducted during this project confirmed the compatibility of supercritical CO 2 with ventilator tubing that, like N95 masks, has been in short supply during portions of the COVID-19 pandemic and cannot be sterilized by conventional means. Finally, a control experiment was also conducted to examine the effect of supercritical CO 2 on a BSL-2 surrogate virus, vesicular stomatitis virus (VSV), Indiana serotype strain. In the absence of biocidal additives, supercritical CO 2 exhibited no measurable lethality against VSV. This surrogate virus experiment suggests that a biocidal additive such as peracetic acid will be necessary to achieve required sterilization metrics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Investigation of Size-Dependent Concentration of Trace Elements in Aerosols Emitted from the Oil-Fired Heating Plants

Aerosols emitted from two oil-fired heating plants were aerodynamically separated into eight size groups and were analyzed using the photon-induced X-ray emission (PIXE) technique. It was found that Zn, Mo, Ag, and Pb, and (to a lesser extent) Cd, have a tendency to concentrate preferentially on the smaller aerosols. All of these elements, in certain chemical forms, are known to be toxic. Zinc and molybdenum, although present in low concentrations in the parent fuels, show the strongest tendencies to be concentrated in finer aerosols. Selenium, previously reported to show a very strong tendency to concentration in finer fly ash from coal-fired power plants shows little preference for surface residence. Vanadium, which occurs in significant concentration in the oil fuels for both plants, also shows little preference for surface concentration. Even though the absolute concentrations of the toxic elements involved are well below the safety levels established by the National Institute for Occupational Safety and Health (NIOSH), it would be advisable to raise the heights of the heating-plant exhaust chimneys well above the neighborhood buildings to insure more efficient aerosol dispersal.

Singh, J. J.↗

Gas Analyzer

The M200 originated in the 1970's under an Ames Research Center/Stanford University contract to develop a small, lightweight gas analyzer for Viking Landers. Although the unit was not used on the spacecraft, it was further developed by The National Institute for Occupational Safety and Health (NIOSH). Three researchers from the project later formed Microsensor Technology, Inc. (MTI) to commercialize the analyzer. The original version (Micromonitor 500) was introduced in 1982, and the M200 in 1988. The M200, a more advanced version, features dual gas chromatograph which separate a gaseous mixture into components and measure concentrations of each gas. It is useful for monitoring gas leaks, chemical spills, etc. Many analyses are completed in less than 30 seconds, and a wide range of mixtures can be analyzed.

Source record↗

Portable Gas Analyzer

The Michromonitor M500 universal gas analyzer contains a series of miniature modules, each of which is a complete gas chromatograph, an instrument which separates a gaseous mixture into its components and measures the concentrations of each gas in the mixture. The system is manufactured by Microsensor Technology, and is used for environmental analysis, monitoring for gas leaks and chemical spills, compliance with pollution laws, etc. The technology is based on a Viking attempt to detect life on Mars. Ames/Stanford miniaturized the system and NIOSH funded further development. Three Stanford researchers commercialized the technology, which can be operated by unskilled personnel.

Source record↗

Gas Analyzer

A miniature gas chromatograph, a system which separates a gaseous mixture into its components and measures the concentration of the individual gases, was designed for the Viking Lander. The technology was further developed under National Institute for Occupational Safety and Health (NIOSH) and funded by Ames Research Center/Stanford as a toxic gas leak detection device. Three researchers on the project later formed Microsensor Technology, Inc. to commercialize the product. It is a battery-powered system consisting of a sensing wand connected to a computerized analyzer. Marketed as the Michromonitor 500, it has a wide range of applications.

Source record↗

Toxicity of Lunar Dust in Lungs Assessed by Examining Biomarkers in Exposed Mice

NASA plans to build an outpost on the Moon for prolonged human habitation and research. The lunar surface is covered by a layer of soil, of which the finest portion is highly reactive dust. NASA has invited NIOSH to collaboratively investigate the toxicity of lunar dust. Dust samples of respirable sizes were aerodynamically isolated from two lunar soil samples of different maturities (cosmic exposure ages) collected during the Apollo 16 mission. The lunar dust samples, titanium dioxide, or quartz, suspended in normal saline or in Survanta (a bovine lung surfactant), were given to groups of 5 mice (C-57 male) by intrapharyngeal aspiration at 1, 0.3, or 0.1 mg/mouse. The mice were euthanized 7 or 30 days later, and their lungs were lavaged to assess the toxicity biomarkers in bronchioalveolar lavage fluids. The acellular fractions were assayed for total proteins, lactate dehydrogenase activities, and cytokines; the cellular portions were assessed for total cell counts and cell differentials. Results from the high-dose groups showed that lunar dust, suspended in saline, was more toxic than TiO 2, but less toxic than quartz. Lunar dust particles aggregate and settle out rapidly in water or saline, but not in Survanta. Lunar dust suspended in Survanta manifested greater toxicity than lunar dust in saline. The increase in toxicity presumably was due to that Survanta gave a better particle dispersion in the lungs. The two lunar dust samples showed similar toxicity. The overall results showed that lunar dust is more toxic than TiO 2 but less toxic than quartz.

Lam, C.-W.↗