Search NASA⌕ Search

SEARCH · Search NASA

Results for “NIOSH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Visualizing the NIOSH Pocket Guide: Open-source web application for accessing and exploring the NIOSH Pocket Guide to Chemical Hazards

The NIOSH Pocket Guide to Chemical Hazards is a trusted resource that displays key information for a collection of chemicals commonly encountered in the workplace. Entries contain chemical structures—occupational exposure limit information ranging from limits based on full-shift time-weighted averages to acute limits such as short-term exposure limits and immediately dangerous to life or health values, as well as a variety of other data such as chemical-physical properties and symptoms of exposure. The NIOSH Pocket Guide (NPG) is available as a printed, hardcopy book, a PDF version, an electronic database, and a downloadable application for mobile phones. All formats of the NIOSH Pocket Guide allow users to access the data for each chemical separately, however, the guide does not support data analytics or visualization across chemicals. This project reformatted existing data in the NPG to make it searchable and compatible with exploration and analysis using a web application. The resulting application allows users to investigate the relationships between occupational exposure limits, the range and distribution of occupational exposure limits, and the specialized sorting of chemicals by health endpoint or to summarize information of particular interest. These tasks would have previously required manual extraction of the data and analysis. The usability of this application was evaluated among industrial hygienists and researchers and while the existing application seems most relevant to researchers, the open-source code and data are amenable to modification by users to increase customization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Filtration Performance Results: Sierra Peaks Material No. 4

Sandia National Laboratories (SNL) assessed the filtration performance of materials from Sierra Peaks to identify alternatives which may perform similarly to materials used in FDA-approved N95 respirators. This work is meant to characterize the aerosol performance of materials to give Sierra Peaks information for them to determine if they elect to submit masks made using these materials for follow-on N95 certification testing at an accredited facility. The R&D testbed used is a large-scale filtration system designed to test commercial filter boxes. System modifications were performed to simulate, where possible, parameters defined by the National Institute for Occupational Safety and Health (NIOSH) for certification of filter materials for N95 respirators (NIOSH 2019). The system is a pull-through design. Air enters through a Laminar Flow Element (LFE) and the volumetric flow is measured based on the pressure drop across the LFE. Pressure is measured via a Pressure Transducer (PT). The air then passes through a High Efficiency Particulate Air (HEPA) filter to purge the air of ambient airborne particulates. Test aerosol is injected into the flow shortly after and mixing is induced via a coarse mesh. The airflow is allowed to fully develop prior to arriving at the test section. The aerosol then passes through the test material mounted in a box in the test section. Pressure drop across the test article is measured and aerosol sampling probes measure the aerosol concentrations upstream and downstream of the sample. The air passes through a second HEPA filter prior to being exhausted to ambient by a blower. A Topas aerosol generator is used to produce the test aerosol from Sodium Chloride (NaC1) dissolved in deionized (DI) water. Generated aerosol passes through a heated mixing chamber and a desiccant dryer to produce nanosized solid-state particulates. A dilution loop allows for the aerosol concentration to be regulated. The aerosol sampling probes upstream and downstream of the test section are aligned with the flow path. These are ducted directly to the aerosol sizing and counting instruments. A Laser Aerosol Spectrometer (LAS) was used for data collection in the original configuration of the system and was also used for initial testing in this project. Because the lower measurement range for the LAS is 90 nanometers (nm), the LAS was switched out for a more complicated Scanning Mobility Particle Sizer (SMPS) spectrometer system. The SMPS is comprised of an Electrostatic Classifier (EC), Differential Mobility Analyzer (DMA), and a Condensation Particle Counter (CPC). This enabled data collection at 75 nm, the particle size called out in the NIOSH guidelines.

36 MATERIALS SCIENCE↗

Proposed Risk-Based Approach for Nitrosamine Chemicals of Potential Concern

This report documents the re-evaluation of Hanford Tank Farm (HTF) occupational exposure limits (OEL) for five N-nitrosamines identified as Chemicals of Potential Concern (COPC), and two other N-nitrosamines being considered as COPCs. N-nitrosamines are genotoxic, and exposure has been historically regulated based on cancer as the endpoint of concern. Currently, HTF OELs are based on German Maximum Arbeitsplatz Konzentration values that are no longer used. The National Institute of Occupational Safety and Health (NIOSH) recently released new policy applying a risk-based approach to develop OELs for occupational carcinogens and plans to release guidance on specific chemicals in the future. Consistent with this new NIOSH policy, Pacific Northwest National Laboratory proposes a risk-based approach to establish risk-specific doses for occupational exposures to N-nitrosamine COPCs. This approach establishes a range of N-nitrosamine inhalation exposures associated with risk levels that can be used as a tool for protecting HTF workers. Updated guidance from NIOSH or other authoritative bodies on N-nitrosamine OELs should trigger a re-evaluation of this proposed approach.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

A Parameterization Study of Sew-EZ Materials: Types #6 and #8

Two material types identified by Sew-EZ were tested in various configurations, and under various conditions, by Sandia National Laboratories (SNL). The primary focus of this study was to assess the filtration performance of these two materials and identify if they perform similarly to certified N95 respirators. Testing was conducted on two systems which use distinctly different techniques to characterize the aerosol penetration characteristics of materials: a) R&D Filtration System: A large-scale R&D filtration system was used with testing parameters that mimicked NIOSH guidelines, where possible. Efficiency data as a function of particle size was attained using NaC1 as the test aerosol and a Scanning Mobility Particle Sizer (SMPS) for measurements. A more detailed system description can be found in Omana et al. 2020. b) Automated Tester: A commercial, automated filter tester (100Xs, Air Techniques International) was used to provide penetration/efficiency data for Sew EZ materials. The 100Xs aerosolizes a polydisperse NaC1 aerosol with a consistent concentration and size profile. The 100Xs manual (Air Techniques International 2018) states, "The aerosol particle size and distribution are designed to meet all requirements as defined in the relevant sections of NIOSH 42 CFR, Part 84 (pg. 32)."

36 MATERIALS SCIENCE↗

Technical Assistance for Characterization Studies of Personal Protection Equipment (PPE) (Final CTAP Report)

Sandia National Laboratories (SNL) conducted an independent assessment of three different certified N95 respirators for the State of New Mexico Department of Homeland Security and Emergency Management. The testing conducted under this effort mimicked traditional NIOSH certification testing methodologies, where possible (NIOSH 2019). This included the use of a commercially available off-the-shelf (COTS) instrument typically used in industry for N95 respirator certification (ATI 2018). The COTS system, an Air Techniques International 100Xs automated filter tester, was used for all the testing reported in this document. It is important to note that SNL is NOT a certification laboratory, and all quantitative results are for informational purposes only. Additional technical information of N95-related efforts conducted by this team may be found in: Omana et al. (2020a), Omana et al. (2020b), Celina et al. (2020)

42 ENGINEERING↗

Mine Rescue Robotics: Gemini-Scout - 18507

Gemini Scout is a mine rescue vehicle developed by Sandia National Laboratories to help locate and communicate with trapped miners following an accident. In a mining accident, first responders are working against a myriad of dangers to assess the situation and rescue trapped miners. The robot can enter potentially dangerous situations ahead of rescuers to evaluate hazardous environments and help them determine how operations should proceed. The Gemini Scout mitigates many of the potential dangers and allows exploration and assessment without further endangering individuals. The robotic vehicle can operate in hostile, debris strewn, dark, muddy, high temperature, and explosive environments. It has extreme ground mobility including operation in up to 18 inches of water and ability to traverse large rubble piles and cross railroad tracks. The vehicle provides gas and temperature sensing as well as pan, tilt, zoom color and thermal camera video streaming back to an operator in a safe zone. The extreme mobility of the vehicle and the modularity of the platform allowing easy integration of sensors are directly applicable to many needs within Waste Management. The development of Gemini Scout was funded by National Institute of Occupational Safety and Health (NIOSH) and the primary customer and certification entity was Mine Safety and Health Administration (MSHA). Lessons-learned during development and steps leading to certification are also applicable to the development of systems for unique Waste Management sites. (authors)

42 ENGINEERING↗

Translating nanoparticle dosimetry from conventional in vitro systems to occupational inhalation exposures

As encouraged by Toxicity Testing in the 21st Century, researchers increasingly apply high-throughput in vitro approaches to identify and characterize nanoparticle hazards, including conventional aqueous cell culture systems to assess respiratory hazards. Translating nanoparticle dose from conventional toxicity testing systems to relevant human exposures remains a major challenge for assessing occupational risk of nanoparticle exposures. Here, we explored existing computational tools and data available to translate nanoparticle dose metrics from cellular test systems to inhalation exposures of silver nanoparticles in humans. We used the Multiple-Path Particle Dosimetry (MPPD) Model to predict deposition of humans exposed to 20 and 110 nm silver nanoparticles at 0.9 µg/m3 over an 8 hr period, the proposed a National Institute of Occupational Safety and Health (NIOSH) recommended exposure limit (REL). MPPD predicts 1.88 and 0.98 µg of silver deposited in an 8 hr period for 20 and 110 nm nanoparticles, respectively, with 20 nm particles displaying nearly 11-fold higher total surface area deposited. Peak nanoparticle concentrations occurred more proximal in the pulmonary tract compared to mass deposition patterns (generation 5 vs. generations 20-21, respectively) due to regional differences in lung lining fluid volumes. Assuming 0.4% nanoparticle dissolution by mass as previously measured, we predict peak concentrations of silver ions in cells of 0.24 and 0.17 µg/mL for 20 and 110 nm particles, respectively. Both predicted concentrations are below the measured toxic threshold of 1.7 µg/mL of silver ions in cells from in vitro assessments. Assuming 4% dissolution by mass, we predict 10-fold higher silver concentrations in tissues, peaking at 2.4 and 1.7 µg/mL, for 20 and 110 nm nanoparticles respectively, exceeding the observed in vitro toxic threshold and highlighting the importance and sensitivity of dissolution rates. Overall, this approach offers a framework for extrapolating nanotoxicity results from in vitro cell culture systems to human exposures. Aligning appropriate dose metrics from in vitro and in vivo hazard characterizations and human pulmonary doses from occupational exposures are critical components for successful nanoparticle risk assessment and worker protection and provide guidance for designing future in vitro studies aimed at relevant human exposures.

Smith, Jordan N.↗

Detection of Airborne Influenza A and SARS-CoV-2 Virus Shedding following Ocular Inoculation of Ferrets

Despite reports of confirmed human infection following ocular exposure with both influenza A virus (IAV) and SARS-CoV-2, the dynamics of virus spread throughout oculonasal tissues and the relative capacity of virus transmission following ocular inoculation remain poorly understood. Furthermore, the impact of exposure route on subsequent release of airborne viral particles into the air has not been examined previously. To assess this, ferrets were inoculated by the ocular route with A(H1N1)pdm09 and A(H7N9) IAVs and two SARS-CoV-2 (early pandemic Washington/1 and Delta variant) viruses. Virus replication was assessed in both respiratory and ocular specimens, and transmission was evaluated in direct contact or respiratory droplet settings. Viral RNA in aerosols shed by inoculated ferrets was quantified with a two-stage cyclone aerosol sampler (National Institute for Occupational Safety and Health [NIOSH]). All IAV and SARS-CoV-2 viruses mounted a productive and transmissible infection in ferrets following ocular inoculation, with peak viral titers and release of virus-laden aerosols from ferrets indistinguishable from those from ferrets inoculated by previously characterized intranasal inoculation methods. Viral RNA was detected in ferret conjunctival washes from all viruses examined, though infectious virus in this specimen was recovered only following IAV inoculation. Low-dose ocular-only aerosol exposure or inhalation aerosol exposure of ferrets to IAV similarly led to productive infection of ferrets and shedding of aerosolized virus. Viral evolution during infection was comparable between all inoculation routes examined. Furthermore, these data support that both IAV and SARS-CoV-2 can establish a high-titer mammalian infection following ocular exposure that is associated with rapid detection of virus-laden aerosols shed by inoculated animals.

60 APPLIED LIFE SCIENCES↗

COVID-19 global pandemic planning: Performance and electret charge of N95 respirators after recommended decontamination methods

Shortages of N95 respirators for use by medical personnel have driven consideration of novel conservation strategies, including decontamination for reuse and extended use. Decontamination methods listed as promising by the Centers for Disease Control and Prevention (CDC) (vaporous hydrogen peroxide (VHP), wet heat, ultraviolet irradiation (UVI)) and several methods considered for low resource environments (bleach, isopropyl alcohol and detergent/soap) were studied for two commonly used surgical N95 respirators (3M™ 1860 and 1870+ Aura™). Although N95 filtration performance depends on the electrostatically charged electret filtration layer, the impact of decontamination on this layer is largely unexplored. As such, respirator performance following decontamination was assessed based on the fit, filtration efficiency, and pressure drop, along with the relationship between (1) surface charge of the electret layer, and (2) elastic properties of the straps. Decontamination with VHP, wet heat, UVI, and bleach did not degrade fit and filtration performance or electret charge. Isopropyl alcohol and soap significantly degraded fit, filtration performance, and electret charge. Pressure drop across the respirators was unchanged. Modest degradation of N95 strap elasticity was observed in mechanical fatigue testing, a model for repeated donnings and doffings. CDC recommended decontamination methods including VHP, wet heat, and UV light did not degrade N95 respirator fit or filtration performance in these tests. Extended use of N95 respirators may degrade strap elasticity, but a loss of face seal integrity should be apparent during user seal checks. NIOSH recommends performing user seal checks after every donning to detect loss of appropriate fit. Decontamination methods which degrade electret charge such as alcohols or detergents should not be used on N95 respirators. The loss of N95 performance due to electret degradation would not be apparent to a respirator user or evident during a negative pressure user seal check.

60 APPLIED LIFE SCIENCES↗

Supercritical CO2 sterilization of N95 Masks

A preliminary investigation of the use of supercritical carbon dioxide for treating of 3M 1860 N95 masks was undertaken to evaluate a potential route to low-cost, scalable, sterilization of personal protective equipment for multiple reuse in hospital settings. Upon entering the supercritical regime, the normally distinct liquid and gaseous phases of CO 2 merge into a single homogeneous phase that has density, short-range order, and solvation capacity of a liquid, but the volume-filling and permeation properties that of a gas. This enables supercritical CO2 to function as a vehicle for delivery of biocidal agents such peracetic acid into microporous structures. The potentially adverse effect of a liquid-to-gas phase transition on mask filter media is avoided by conducting cleaning operations above 31 C, the critical temperature for carbon dioxide. A sample of fifteen 3M 1860 N95 masks was subjected to ten consecutive cycles of supercritical CO 2 cleaning to determine its effect on mask performance. These 15 masks, along with 5 control samples then underwent a battery of standardized tests at the CDC NIOSH NPPTL research facility in Pittsburgh, PA. The data from these tests strongly suggest (but do not prove) that supercritical carbon dioxide do not damage 3M 1860 N95 masks. Additional tests conducted during this project confirmed the compatibility of supercritical CO 2 with ventilator tubing that, like N95 masks, has been in short supply during portions of the COVID-19 pandemic and cannot be sterilized by conventional means. Finally, a control experiment was also conducted to examine the effect of supercritical CO 2 on a BSL-2 surrogate virus, vesicular stomatitis virus (VSV), Indiana serotype strain. In the absence of biocidal additives, supercritical CO 2 exhibited no measurable lethality against VSV. This surrogate virus experiment suggests that a biocidal additive such as peracetic acid will be necessary to achieve required sterilization metrics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Conversion of CO 2 from power plant into CaCO 3 nanoparticles

Carbon dioxide (CO 2 ), a main composition of flue gas, represents a significant and largely untapped carbon resource. Herein, mediated by glycine (Gly), we captured and converted CO 2 into CaCO 3 nanoparticles using real flue gas from a power plant, demonstrating for the first time the feasibility of using amino acid to convert CO 2 from power plant flue gasses. The method did not require extraneous energy and CaCO 3 nanoparticles with a size of ∼25 nm were obtained. Moreover, the potential toxicity of CO 2 -converted nanoparticles was investigated. It appeared that both the initial CO 2 loading and the carbamate percentage significantly influence the shape and size of the CaCO 3 particles. Our method was also proven effective for flue gas with varying CO 2 concentrations (4 %, 12 %, and 20 %). By tuning flue gas bubbling time and flow rate to achieve consistent CO 2 loading and carbamate levels, we produced CaCO 3 nanoparticles with similar shapes and sizes across all CO 2 concentrations studied. In addition, our data indicated that although real flue gas contains small amounts of gases like oxygen and CO, they insignificantly influence the shape and size of our nanoparticles but did impact the phase component of CaCO 3 . In conclusion, the toxicity experiments found that CaCO 3 nanoparticles produced from both real flue gas and simulated flue gas exhibited concentration- and time-dependent effects on cell viability.

36 MATERIALS SCIENCE↗

Lead exposure is related to hypercortisolemic profiles and allostatic load in Brazilian older adults

Lead levels (Pb) have been linked to both hyper- and hypo-reactivity of hypothalamic-pituitary-adrenal axis (HPA) axis to acute stress in animals and humans. Similarly, allostatic load (AL), the ‘wear and tear’ of chronic stress, is associated with inadequate HPA axis activity. We examined whether Pb levels would be associated with altered diurnal cortisol profile, as a primary mediator of AL, during aging. Pb levels were measured from blood samples (BPb) of 126 Brazilian individuals (105 women), between 50 and 82 years old. Six neuroendocrine, metabolic, and anthropometric biomarkers were analyzed and values were transformed into an AL index using clinical reference cut-offs. Salivary samples were collected at home over 2 days at awakening, 30-min after waking, afternoon, and evening periods to determine cortisol levels. A multiple linear regression model showed a positive association between BPb as the independent continuous variable and cortisol awakening response (R{sup 2}=0.128; B=0.791; p=0.005) and overall cortisol concentration (R{sup 2}=0.266; B=0.889; p<0.001) as the outcomes. Repeated measures ANOVA showed that individuals with high BPb levels showed higher cortisol at 30 min after awakening (p=0.003), and in the afternoon (p=0.002) than those with low BPb values. Regarding AL, regression model showed that BPb was positively associated with AL index (R{sup 2}=0.100; B=0.204; p=0.032). Correlation analyzes with individual biomarkers showed that BPb was positively correlated with HDL cholesterol (p=0.02) and negatively correlated with DHEA-S (p=0.049). These findings suggest that Pb exposure, even at levels below the reference blood lead level for adults recommended by the National Institute for Occupational Safety and Health and by the Center for Disease Control and Prevention, may contribute to AL and dysregulated cortisol functioning in older adults. Considering these findings were based on cross-sectional data future research is needed to confirm our exploratory results. - Highlights: • Lead exposure is associated with several negative health outcomes. • Allostatic load (AL), the wear and tear of chronic stress, may be affected by lead exposure. • Lead concentration was associated with high cortisol levels and high allostatic load. • Even at very low levels of exposure, lead was associated with chronic stress mediators.

60 APPLIED LIFE SCIENCES↗