Search NASA⌕ Search

SEARCH · Search NASA

Results for “NIST Standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Status of emerging standards for removable computer storage media and related contributions of NIST

Standards for removable computer storage media are needed so that users may reliably interchange data both within and among various computer installations. Furthermore, media interchange standards support competition in industry and prevent sole-source lock-in. NIST participates in magnetic tape and optical disk standards development through Technical Committees X3B5, Digital Magnetic Tapes, X3B11, Optical Digital Data Disk, and the Joint Technical Commission on Data Permanence. NIST also participates in other relevant national and international standards committees for removable computer storage media. Industry standards for digital magnetic tapes require the use of Standard Reference Materials (SRM's) developed and maintained by NIST. In addition, NIST has been studying care and handling procedures required for digital magnetic tapes. NIST has developed a methodology for determining the life expectancy of optical disks. NIST is developing care and handling procedures for optical digital data disks and is involved in a program to investigate error reporting capabilities of optical disk drives. This presentation reflects the status of emerging magnetic tape and optical disk standards, as well as NIST's contributions in support of these standards.

Podio, Fernando L.↗

Measurements of dimethyl sulfide and SO2 during GTE/CITE 3

As part of NASA's Tropospheric Experiment Chemical Instrumentation Test and Evaluation (GTE/CITE 3) Sulfur Gas Intercomparison, we conducted measurements of dimethyl sulfide (DMS) and SO2 using two techniques well suited for sampling from an aircraft due to their simplicity of design. DMS was collected by preconcentration on gold wire preceded by a KOH-impregnated filter oxidant scrubber, and analyzed by gas chromatography with flame photometric detection. SO2 was collected on K2CO3/glycerol-impregnated filters and analyzed by ion chromatography. In blind tests, both techniques produced excellent agreement with National Institutes of Standards and Technology (NIST) standards. For field measurements, the DMS technique produced excellent correlation with the mean of the six different techniques intercompared. For SO2, the five techniques intercompared were rather poorly correlated, but correlations between the three techniques which passed NIST standards tests were somewhat better. Our SO2 filter measurements exhibited rather large uncertainties due to higher than normal variabiltiy of the filter blanks, which we believe was caused by extended storage in the field. In measurements conducted off the coast of Natal, Brazil, a diurnal afternoon minimum in DMS concentrations accompanied by a corresponding maximum in SO2 concentrations was observed. However, due to rather large uncertainties in the SO2 measurements, any conclusions about the SO2 trend must by considered tentative.

Ferek, Ronald J.↗

Exploring a Black Body Source as an Absolute Radiometric Calibration Standard and Comparison with a NIST Traced Lamp Standard

Radiometric calibration of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) is required for the scientific research and application objectives pursued with the spectroscopic measurements. Specifically calibration is required for: inter-comparison of AVIRIS data measured at different locations and at different times; analysis of AVIRIS data with data measured by other instruments; and analysis of AVIRIS data in conjunction with computer models. The primary effect of radiometric calibration is conversion of AVIRIS instrument response values (digitized numbers, or DN) to units of absolute radiance. For example, a figure shows the instrument response spectrum measured by AVIRIS over a portion of Rogers Dry Lake, California, and another figure shows the same spectrum calibrated to radiance. Only the calibrated spectrum may be quantitatively analyzed for science research and application objectives. Since the initial development of the AVIRIS instrument-radiometric calibration has been based upon a 1000-W irradiance lamp with a calibration traced to the National Institute of Standards and Technology (NIST). There are several advantages to this irradiance-lamp calibration approach. First, the considerable effort of NIST backs up the calibration. Second, by changing the distance to the lamp, the output can closely span the radiance levels measured by AVIRIS. Third, this type of standard is widely used. Fourth, these calibrated lamps are comparatively inexpensive. Conversely, there are several disadvantages to this approach as well. First, the lamp is not a primary standard. Second, the lamp output characteristics may change in an unknown manner through time. Third, it is difficult to assess, constrain, or improve the calibration uncertainty delivered with the lamp. In an attempt to explore the effect and potentially address some of these disadvantages a set of analyses and measurements comparing an irradiance lamp with a black-body source have been completed. This research is ongoing, and the current set of measurements, analyses, and results are presented in this paper.

Green, Robert O.↗

Real-Time Protocol Engineering with the B Language

It is an invariant that critical cyberphysical systems should not fail. Mission assurance requires systems to behave with predictability, especially in their ability to satisfy real-time constraints. The NIST standard for Engineering Trustworthy Secure Systems, National Institute of Standards and Technology (NIST) Special Publication (SP) 800-160v1r1 states that formal methods are the highest level for meeting assurance requirements. There is a tension between the formal method software development process (Figure 1), which does not introduce time specificity until the latter stages of the development process (concrete model), and the need to gain confidence that time constraints will be satisfied. This paper formalizes the practical application of temporal entities e.g. Propositional Temporal Logic (PTL), Temporal Logic of Actions Plus (TLA+), etc. to critical systems.

97 MATHEMATICS AND COMPUTING↗

Parahydrogen Properties Version 05 Database Release for Nuclear Thermal Propulsion Applications

Consistent modeling assumptions across any large project are crucial to minimize errors between different approaches. Use of consistent material and fluid properties across a large project supports consistent interpretation and application within modeling and simulation results as well as their relevancy to operational systems. NASA’s Space Nuclear Propulsion program dedicates extensive resources towards establishing consistent and, to the extent possible, accurate property databases for its internal staff and all external partners. This work highlights the extensive research performed to modernize the fluid property database of hydrogen which is the leading propellant option for in-space nuclear propelled spacecraft. Specifically, the parahydrogen spin state is of interest since the propellant is stored in a near normal boiling point liquid state which results in it consisting almost entirely of the parahydrogen spin isomer. This database tool has taken recent NASA work and modernized it into a python-based package for easy usage across all modeling entities. The package allows users to provide temperature and pressure pairs along with their desired output properties to yield results accounting for both real-gas and equilibrium dissociation effects while also sharing the default thermodynamic reference state provided by the National Institute of Standards and Technology (NIST) Standard Database 23. The suite also includes advanced capabilities to increase usability, such as on-the-fly interpolation and multidimensional plotting.

Nuclear Thermal Propulsion↗

Parahydrogen Properties Version 05 Database Release for NTP Applications

Consistent modeling assumptions across any large project are crucial to minimize errors between different approaches. Use of consistent material and fluid properties across a large project supports consistent interpretation and application within modeling and simulation results as well as their relevancy to operational systems. NASA’s Space Nuclear Propulsion program dedicates extensive resources towards establishing consistent and, to the extent possible, accurate property databases for its internal staff and all external partners. This work highlights the extensive research performed to modernize the fluid property database of hydrogen which is the leading propellant option for in-space nuclear propelled spacecraft. Specifically, the parahydrogen spin state is of interest since the propellant is stored in a near normal boiling point liquid state which results in it consisting almost entirely of the parahydrogen spin isomer. This database tool has taken recent NASA work and modernized it into a python-based package for easy usage across all modeling entities. The package allows users to provide temperature and pressure pairs along with their desired output properties to yield results accounting for both real-gas and equilibrium dissociation effects while also sharing the default thermodynamic reference state provided by the National Institute of Standards and Technology (NIST) Standard Database 23. The suite also includes advanced capabilities to increase usability, such as on-the-fly interpolation and multidimensional plotting.

Nuclear Thermal Propulsion↗

Potassium Isotopic Compositions of NIST Potassium Standards and 40Ar/39Ar Mineral Standards

Knowledge of the isotopic ratios of standards, spikes, and reference materials is fundamental to the accuracy of many geochronological methods. For example, the 238U/235U ratio relevant to U-Pb geochronology was recently re-determined [1] and shown to differ significantly from the previously accepted value employed during age determinations. These underlying values are fundamental to accurate age calculations in many isotopic systems, and uncertainty in these values can represent a significant (and often unrecognized) portion of the uncertainty budget for determined ages. The potassium isotopic composition of mineral standards, or neutron flux monitors, is a critical, but often overlooked component in the calculation of K-Ar and 40Ar/39Ar ages. It is currently assumed that all terrestrial materials have abundances indistinguishable from that of NIST SRM 985 [2]; this is apparently a reasonable assumption at the 0.25per mille level (1σ) [3]. The 40Ar/39Ar method further relies on the assumption that standards and samples (including primary and secondary standards) have indistinguishable 40K/39K values. We will present data establishing the potassium isotopic compositions of NIST isotopic K SRM 985, elemental K SRM 999b, and 40Ar/39Ar biotite mineral standard GA1550 (sample MD-2). Stable isotopic compositions (41K/39K) were measured by the peak shoulder method with high resolution MC-ICP-MS (Thermo Scientific NEPTUNE Plus), using the accepted value of NIST isotopic SRM 985 [2] for fractionation [4] corrections [5]. 40K abundances were measured by TIMS (Thermo Scientific TRITON), using 41K/39K values from ICP-MS measurements (or, for SRM 985, values from [2]) for internal fractionation corrections. Collectively these data represent an important step towards a metrologically traceable calibration of 40K concentrations in primary 40Ar/39Ar mineral standards and improve uncertainties by ca. an order of magnitude in the potassium isotopic compositions of standards.

Morgan, Leah↗

Corresponding Standard Reference Material Data used in Partial Least Squares Regression Models for Sugar Composition Estimates in Biomass in: Economic Impact of Yield and Composition Variation in Bioenergy Crops: Populus trichocarpa

Corresponding Standard Reference Material Data used in Partial Least Squares Regression Models for Sugar Composition Estimates in Biomass in: Economic Impact of Yield and Composition Variation in Bioenergy Crops: Populus trichocarpa (for corresponding manuscript: DOI: 10.1002/bbb.2148) PDF Files: Images of 1H NMR spectra for neutralized 2-stage acid hydrolysates of 4 NIST Standard Reference Material biomass samples (Monterey Pine 8493, Sugarcane Bagasse 8491, Wheat Straw 8494, and Eastern Cottonwood/Poplar 8492) and 2 Center for Bioenergy Innovation reference biomass samples (Poplar - Populus trichocarpa and Switchgrass - Panicum Virgatum). Suppression of the water peak was achieved using a NOESY-1D with presaturation, a recycle delay of 5 s, and a total of 64 scans. Spectra were acquired at 298 K and processed with automatic phase correction, baseline correction, and chemical shift referencing to TSP-d4. Images show all 1H data from 10 to 1ppm with inset spectra of region of interest (4.0 to 3.1 ppm). Text Files: Spectra for neutralized 2-stage acid hydrolysates of 4 NIST Standard Reference Material biomass samples (Monterey Pine 8493, Sugarcane Bagasse 8491, Wheat Straw 8494, and Eastern Cottonwood/Poplar 8492) and 2 Center for Bioenergy Innovation reference biomass samples (Poplar - Populus trichocarpa and Switchgrass - Panicum Virgatum) were converted into text files for plotting. Files contain 8192 points of raw spectral data from 12.23 to -2.78 ppm. The text file contains 4 columns of data and includes: Point number, Intensity, Hz, and ppm. Xcel Spreadsheet: HPLC measured monomeric sugar concentrations and bucketed 1H NMR data used to build monomeric sugar composition prediction models. Sugar composition in biomass determined from HPLC analyses are given in mg sugar/mg of biomass. Spectral bucketing was performed using Bruker’s AMIX software. Spectra were divided into 0.005 ppm buckets in the region of 3.10– 4.15 ppm for a total of 210 buckets. Headers for the bucketed data are the chemical shift in ppm of the center of the bucket. Bucketed data was used to build partial least squares models for subsequent predictions in The Unscrambler v. 10.5(CAMO A/S, Trondheim, Norway). The formation of methanol during hydrolysis interferes with the quantitative NMR analysis of sugars, so the methanol peak centered at 3.37 ppm and spanning four buckets (3.2925 – 3.2775 ppm) was set to zero for all spectra.

09 BIOMASS FUELS↗

High-Performance X-ray Detection in a New Analytical Electron Microscope

X-ray detection by energy-dispersive spectrometry in the analytical electron microscope (AEM) is often limited by low collected X-ray intensity (P), modest peak-to-background (P/B) ratios, and limitations on total counting time (tau) due to specimen drift and contamination. A new AFM has been designed with maximization of P. P/B, and tau as the primary considerations. Maximization of P has been accomplished by employing a field-emission electron gun, X-ray detectors with high collection angles, high-speed beam blanking to allow only one photon into the detector at a time, and simultaneous collection from two detectors. P/B has been maximized by reducing extraneous background signals generated at the specimen holder, the polepieces and the detector collimator. The maximum practical tau has been increased by reducing specimen contamination and employing electronic drift correction. Performance improvments have been measured using the NIST standard Cr thin film. The 0-3 steradian solid angle of X-ray collection is the highest value available. The beam blanking scheme for X-ray detection provides 3-4 times greater throughput of X-rays at high count rates into a recorded spectrum than normal systems employing pulse-pileup rejection circuits. Simultaneous X-ray collection from two detectors allows the highest X-ray intensity yet recorded to be collected from the NIST Cr thin film. The measured P/B of 6300 is the highest level recorded for an AEM. In addition to collected X-ray intensity (cps/nA) and P/B measured on the standard Cr film, the product of these can be used as a figure-of-merit to evaluate instruments. Estimated minimum mass fraction (MMF) for Cr measured on the standard NIST Cr thin film is also proposed as a figure-of-merit for comparing X-ray detection in AEMs. Determinations here of the MMF of Cr detectable show at least a threefold improvement over previous instruments.

Lyman, C. E.↗

The Prediction Properties of Inverse and Reverse Regression for the Simple Linear Calibration Problem

The calibration of measurement systems is a fundamental but under-studied problem within industrial statistics. The origins of this problem go back to basic chemical analysis based on NIST standards. In today's world these issues extend to mechanical, electrical, and materials engineering. Often, these new scenarios do not provide "gold standards" such as the standard weights provided by NIST. This paper considers the classic "forward regression followed by inverse regression" approach. In this approach the initial experiment treats the "standards" as the regressor and the observed values as the response to calibrate the instrument. The analyst then must invert the resulting regression model in order to use the instrument to make actual measurements in practice. This paper compares this classical approach to "reverse regression," which treats the standards as the response and the observed measurements as the regressor in the calibration experiment. Such an approach is intuitively appealing because it avoids the need for the inverse regression. However, it also violates some of the basic regression assumptions.

Parker, Peter A.↗

Reference Materials for Laser and Xenon Flash Thermal Diffusivity Systems

This report presents the status of current standard reference materials for thermal diffusivity testing. In most thermal properties testing systems, it is common to use standard reference materials to show the reproducibility of the tests and certify the instrument is producing results within expected uncertainty range. The definition of reference materials or standards vary depending on the quality control protocols of the project. For thermal diffusivity, although there were standards available by the National Bureau of Standards (NBS) 40 years ago, there has been no recent NIST standard reference material (SRM). There are only a few sources that produce and provide traceable reference standards for thermal diffusivity. The certificate typically expires in 5 years and only applies to the specific lot of materials. Other reference materials are provided by the testing systems manufacturers. They are mostly well-known reference materials or materials used by the equipment manufacturers with historic data. However, most these reference materials no longer carry valid certificates. Various reference materials will be discussed along with the industry practice when only secondary standards are available.

36 MATERIALS SCIENCE↗

Understanding Biases in Sample Preparation Techniques for Coupled Scanning Electron Microscopy and MAMA PuO 2 Morphological Analysis

In this project, the scanning electron microscopy (SEM) sampling method used during the statistical design study (SDS) was investigated to determine if any sampling biases were present in the analyzed data. Using standard particle size distribution powders from the National Institute of Standards and Technology (NIST 1984 standard reference material) with the origin wet dispersion method, it was determined that a bias to smaller particles was present. This was supported by theoretical calculations using Stokes’ law to determine the settling rate of spherical particles of roughly the same size and mass as those found in the SDS. Based on the theoretical calculations, it was determined that the settling rate for each of the 76 powder sets in the SDS could be unique based on specific particle shape and mass distributions, making a universal correction factor/formula not applicable. Therefore, priority shifted to developing an improved wet dispersion method that significantly reduced the particle settling rate for all particle size and shapes. This was achieved by replacing the original solvent (isopropyl alcohol) with a heavy liquid (lithium heteropolytungstates), which dramatically slowed the settling rate and allowed for the capture of a suitable homogeneous aliquot. SEM imaging and Morphological Analysis for Material Attribution (MAMA) software analysis were conducted on the NIST standard, and the SEM/MAMA data were compared to data captured by a dynamic image analysis particle size analyzer. The resulting data confirmed that the new wet dispersion method does indeed deliver an improved representative aliquot to the SEM stub. For instance, in the NIST certificate, the average particle size is ~17.1 µm ± 2.2 µm with a normal distribution. The initial wet dispersion method resulted in a drastically reduced average particle size of 6.1 µm in addition to a non-representative heavy bi-modal distribution whereas the improved LST wet dispersion method resulting in an average particle size that was much closer to the NIST certificate (12.7 µm) with a similar normal distribution. Although the improved method was still short of the NIST certificate average, atomic force microscopy analysis determined that the resulting ~20-25% reduction in size was due to particles sinking into the carbon sticky tape used for SEM imaging. It is believed that that this bias can be calibrated in a much more predicable manner than the original settling rate bias. In addition, the matching normal distribution curves between the NIST certificate and the heavy liquid method indicate a much-improved representative aliquot has been sampled and imaged. A surrogate CeO 2 powder was used to reflect PuO 2 more accurately and to aid in implementing radiological controls and shielding. The resulting data sets from the SEM/MAMA method and the particle size analyzer give almost identical average particle sizes and particle distribution statistics. Future work will re-analyze several select runs from the SDS to determine if morphological signatures can be found with the improved sampling method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantifying Cybersecurity Risk for NASA Missions

An end-to-end cyber risk assessment process is presented that is based on the combination of guidelines from the National Institute of Standards & Technology (NIST), the standard 5x5 risk matrix, and quantitative methods for generating loss exceedance curves. The NIST guidelines provide a framework for cyber risk assessment, and the standard 5x5 matrix is widely used across the industry for the representation of risk across multiple disciplines. Loss exceedance curves are a means of quantitatively assessing the loss that occurs due to a given risk profile. Combining these different techniques enables us to follow the guidelines, adhere to standard 5x5 risk management practices and develop quantitative metrics simultaneously. Our quantification process is based on the consideration of the NASA and JPL Cost Risk assessment modeling techniques as we define the cost associated with the cybersecurity risk profile of a mission as a function of the mission cost.

Miller, Robert L.↗

Experimental Investigation of Barium Sources and Fluid–Rock Interaction in Unconventional Marcellus Shale Wells Using Ba Isotopes

Produced waters from unconventional Marcellus Shale gas wells have anomalously high barium (Ba) concentrations and yield some of the isotopically heaviest Ba measured to date. Experiments were conducted to constrain the source of Ba in these fluids and the controls on barite (BaSO 4 ) precipitation and dissolution in oil and gas wells. Experiments simulating the acidizing stage evaluated the solubility of pure barite and drilling mud in 2 M HCl at 80 °C for periods of 2, 6, and 48 h and resulted in <0.01% barite dissolution with no appreciable change in δ 138 Ba ( 138 Ba/ 134 Ba normalized to NIST standard 3104a). Static autoclave experiments conducted at 66 °C and 20.7 MPa with combinations of ground Marcellus Shale solids and/or barite-bearing drilling mud with synthetic low-Ba fracturing fluid resulted in decreased Ba concentrations in the fluid, with the largest decrease in the shale-only run. Fluid δ 138 Ba values increased by about 0.5‰ as Ba concentrations decreased, consistent with closed-system Rayleigh fractionation. Flow-through experiments in Marcellus Shale core conducted for 28 days resulted in effluent Ba concentrations an order of magnitude lower than the influent, while sulfate concentrations increased over time. Effluent δ 138 Ba values increased over the first 12 days and plateaued at about 1‰ higher than the influent. Modeling suggests a combination of the release of labile shale Ba and barite precipitation. This work indicates that the processes of Ba release from fluid–shale interactions and barite precipitation in fractures and the well bore, while capable of producing high δ 138 Ba fluids, are unlikely to generate fluids with high-Ba concentrations and δ 138 Ba values like those in Marcellus-produced waters. As a result, we find that the release of sulfate from shale pyrite oxidation rapidly catalyzes barite precipitation and that dissolution of drilling mud barite or natural barite in the shale is unlikely to be the major source of Ba in Marcellus-produced waters.

54 ENVIRONMENTAL SCIENCES↗

Bubble Point Measurements of Three Binary Mixtures of Refrigerants: R-32/1234yf, R-32/1234ze(E), and R-1132a/1234yf

In this article, bubble point pressures of three binary mixtures at two compositions each have been measured utilizing a static method. The mixtures studied were difluoromethane + 2,3,3,3-tetrafluoroprop-1-ene (R-32/1234yf), difluoromethane + (E)-1,3,3,3-tetrafluoroprop-1-ene (R-32/1234ze(E)), and 1,1-difluoroethene + 2,3,3,3-tetrafluoroprop-1-ene (R-1132a/1234yf). For all of the mixtures, the minimum temperature measured was 270 K. The maximum temperatures measured for the R-32/1234ze(E), R-32/1234yf, and R-1132a/1234yf mixtures were 360, 345, and 325 K, respectively. A total of 100 bubble point pressures are reported and compared to available literature data relative to the REFPROP database. Lemmon, E. W. [ NIST Standard Reference Database 23: Reference Fluid Thermodynamic and Transport Properties-REFPROP, 10.0; National Institute of Standards and Technology, Standard Reference Data Program: Gaithersburg, 2018]. Additionally, the bubble point pressures obtained in this study are modeled using the perturbed-chain statistical associating fluid theory (PC-SAFT) equation of state. The PC-SAFT model parameters, as well as deviations of this work and literature data from the model, are reported.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interlaboratory Study for Characterizing Monoclonal Antibodies by Top-Down and Middle-Down Mass Spectrometry

The Consortium for Top-Down Proteomics (www.topdownproteomics.org) launched the present study to assess the state of top-down mass spectrometry (TD MS) and middle-down mass spectrometry (MD MS) for characterizing monoclonal antibody (mAb) primary structures, including their modifications. To meet the needs of the rapidly growing therapeutic antibody market, it is important to develop analytical strategies to characterize the heterogeneity of a therapeutic product’s primary structure reliably and reproducibly. The major objective of the present study was to determine whether current TD/MD MS technologies and protocols can add value to the more commonly employed bottom-up approaches, such as confirming protein integrity, sequencing variable domains, ruling out artefacts, and revealing modifications and their locations. A panel of three mAbs was selected and centrally provided to twenty laboratories worldwide for the analysis: Sigma mAb standard (SiLuLite), NIST mAb standard, and the therapeutic mAb Herceptin (trastuzumab). A variety of different MS instrument platforms and ion dissociation techniques were employed. Overall, the present study confirms that MD/TD MS strategies are valuable and readily available tools in laboratories worldwide. They provide complementary information to the bottom-up approach and can add unique information, which may be crucial for comprehensive mAb characterization. The current limitations, as well as possible solutions to overcome them, are also outlined. One of the limitations revealed by the results of the present study is that the expert knowledge in both experiment and data analysis is indispensable to practice TD/MD MS, but the number of TD/MD MS experts is still very low.

59 BASIC BIOLOGICAL SCIENCES↗

Numeric data distribution: The vital role of data exchange in today's world

The major aim of the NIST standard Reference Data Program (SRD) is to provide critically evaluated numeric data to the scientific and technical community in a convenient and accessible form. A second aim of the program is to provide feedback into the experimental and theoretical programs to help raise the general standards of measurement. By communicating the experience gained in evaluating the world output of data in the physical sciences, NIST/SRD helps to advance the level of experimental techniques and improve the reliability of physical measurements.

Chase, Malcolm W.↗