Search NASA⌕ Search

SEARCH · Search NASA

Results for “NIST Standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Status of emerging standards for removable computer storage media and related contributions of NIST

Standards for removable computer storage media are needed so that users may reliably interchange data both within and among various computer installations. Furthermore, media interchange standards support competition in industry and prevent sole-source lock-in. NIST participates in magnetic tape and optical disk standards development through Technical Committees X3B5, Digital Magnetic Tapes, X3B11, Optical Digital Data Disk, and the Joint Technical Commission on Data Permanence. NIST also participates in other relevant national and international standards committees for removable computer storage media. Industry standards for digital magnetic tapes require the use of Standard Reference Materials (SRM's) developed and maintained by NIST. In addition, NIST has been studying care and handling procedures required for digital magnetic tapes. NIST has developed a methodology for determining the life expectancy of optical disks. NIST is developing care and handling procedures for optical digital data disks and is involved in a program to investigate error reporting capabilities of optical disk drives. This presentation reflects the status of emerging magnetic tape and optical disk standards, as well as NIST's contributions in support of these standards.

Podio, Fernando L.↗

Measurements of dimethyl sulfide and SO2 during GTE/CITE 3

As part of NASA's Tropospheric Experiment Chemical Instrumentation Test and Evaluation (GTE/CITE 3) Sulfur Gas Intercomparison, we conducted measurements of dimethyl sulfide (DMS) and SO2 using two techniques well suited for sampling from an aircraft due to their simplicity of design. DMS was collected by preconcentration on gold wire preceded by a KOH-impregnated filter oxidant scrubber, and analyzed by gas chromatography with flame photometric detection. SO2 was collected on K2CO3/glycerol-impregnated filters and analyzed by ion chromatography. In blind tests, both techniques produced excellent agreement with National Institutes of Standards and Technology (NIST) standards. For field measurements, the DMS technique produced excellent correlation with the mean of the six different techniques intercompared. For SO2, the five techniques intercompared were rather poorly correlated, but correlations between the three techniques which passed NIST standards tests were somewhat better. Our SO2 filter measurements exhibited rather large uncertainties due to higher than normal variabiltiy of the filter blanks, which we believe was caused by extended storage in the field. In measurements conducted off the coast of Natal, Brazil, a diurnal afternoon minimum in DMS concentrations accompanied by a corresponding maximum in SO2 concentrations was observed. However, due to rather large uncertainties in the SO2 measurements, any conclusions about the SO2 trend must by considered tentative.

Ferek, Ronald J.↗

Exploring a Black Body Source as an Absolute Radiometric Calibration Standard and Comparison with a NIST Traced Lamp Standard

Radiometric calibration of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) is required for the scientific research and application objectives pursued with the spectroscopic measurements. Specifically calibration is required for: inter-comparison of AVIRIS data measured at different locations and at different times; analysis of AVIRIS data with data measured by other instruments; and analysis of AVIRIS data in conjunction with computer models. The primary effect of radiometric calibration is conversion of AVIRIS instrument response values (digitized numbers, or DN) to units of absolute radiance. For example, a figure shows the instrument response spectrum measured by AVIRIS over a portion of Rogers Dry Lake, California, and another figure shows the same spectrum calibrated to radiance. Only the calibrated spectrum may be quantitatively analyzed for science research and application objectives. Since the initial development of the AVIRIS instrument-radiometric calibration has been based upon a 1000-W irradiance lamp with a calibration traced to the National Institute of Standards and Technology (NIST). There are several advantages to this irradiance-lamp calibration approach. First, the considerable effort of NIST backs up the calibration. Second, by changing the distance to the lamp, the output can closely span the radiance levels measured by AVIRIS. Third, this type of standard is widely used. Fourth, these calibrated lamps are comparatively inexpensive. Conversely, there are several disadvantages to this approach as well. First, the lamp is not a primary standard. Second, the lamp output characteristics may change in an unknown manner through time. Third, it is difficult to assess, constrain, or improve the calibration uncertainty delivered with the lamp. In an attempt to explore the effect and potentially address some of these disadvantages a set of analyses and measurements comparing an irradiance lamp with a black-body source have been completed. This research is ongoing, and the current set of measurements, analyses, and results are presented in this paper.

Green, Robert O.↗

Parahydrogen Properties Version 05 Database Release for Nuclear Thermal Propulsion Applications

Consistent modeling assumptions across any large project are crucial to minimize errors between different approaches. Use of consistent material and fluid properties across a large project supports consistent interpretation and application within modeling and simulation results as well as their relevancy to operational systems. NASA’s Space Nuclear Propulsion program dedicates extensive resources towards establishing consistent and, to the extent possible, accurate property databases for its internal staff and all external partners. This work highlights the extensive research performed to modernize the fluid property database of hydrogen which is the leading propellant option for in-space nuclear propelled spacecraft. Specifically, the parahydrogen spin state is of interest since the propellant is stored in a near normal boiling point liquid state which results in it consisting almost entirely of the parahydrogen spin isomer. This database tool has taken recent NASA work and modernized it into a python-based package for easy usage across all modeling entities. The package allows users to provide temperature and pressure pairs along with their desired output properties to yield results accounting for both real-gas and equilibrium dissociation effects while also sharing the default thermodynamic reference state provided by the National Institute of Standards and Technology (NIST) Standard Database 23. The suite also includes advanced capabilities to increase usability, such as on-the-fly interpolation and multidimensional plotting.

Nuclear Thermal Propulsion↗

Parahydrogen Properties Version 05 Database Release for NTP Applications

Consistent modeling assumptions across any large project are crucial to minimize errors between different approaches. Use of consistent material and fluid properties across a large project supports consistent interpretation and application within modeling and simulation results as well as their relevancy to operational systems. NASA’s Space Nuclear Propulsion program dedicates extensive resources towards establishing consistent and, to the extent possible, accurate property databases for its internal staff and all external partners. This work highlights the extensive research performed to modernize the fluid property database of hydrogen which is the leading propellant option for in-space nuclear propelled spacecraft. Specifically, the parahydrogen spin state is of interest since the propellant is stored in a near normal boiling point liquid state which results in it consisting almost entirely of the parahydrogen spin isomer. This database tool has taken recent NASA work and modernized it into a python-based package for easy usage across all modeling entities. The package allows users to provide temperature and pressure pairs along with their desired output properties to yield results accounting for both real-gas and equilibrium dissociation effects while also sharing the default thermodynamic reference state provided by the National Institute of Standards and Technology (NIST) Standard Database 23. The suite also includes advanced capabilities to increase usability, such as on-the-fly interpolation and multidimensional plotting.

Nuclear Thermal Propulsion↗

Potassium Isotopic Compositions of NIST Potassium Standards and 40Ar/39Ar Mineral Standards

Knowledge of the isotopic ratios of standards, spikes, and reference materials is fundamental to the accuracy of many geochronological methods. For example, the 238U/235U ratio relevant to U-Pb geochronology was recently re-determined [1] and shown to differ significantly from the previously accepted value employed during age determinations. These underlying values are fundamental to accurate age calculations in many isotopic systems, and uncertainty in these values can represent a significant (and often unrecognized) portion of the uncertainty budget for determined ages. The potassium isotopic composition of mineral standards, or neutron flux monitors, is a critical, but often overlooked component in the calculation of K-Ar and 40Ar/39Ar ages. It is currently assumed that all terrestrial materials have abundances indistinguishable from that of NIST SRM 985 [2]; this is apparently a reasonable assumption at the 0.25per mille level (1σ) [3]. The 40Ar/39Ar method further relies on the assumption that standards and samples (including primary and secondary standards) have indistinguishable 40K/39K values. We will present data establishing the potassium isotopic compositions of NIST isotopic K SRM 985, elemental K SRM 999b, and 40Ar/39Ar biotite mineral standard GA1550 (sample MD-2). Stable isotopic compositions (41K/39K) were measured by the peak shoulder method with high resolution MC-ICP-MS (Thermo Scientific NEPTUNE Plus), using the accepted value of NIST isotopic SRM 985 [2] for fractionation [4] corrections [5]. 40K abundances were measured by TIMS (Thermo Scientific TRITON), using 41K/39K values from ICP-MS measurements (or, for SRM 985, values from [2]) for internal fractionation corrections. Collectively these data represent an important step towards a metrologically traceable calibration of 40K concentrations in primary 40Ar/39Ar mineral standards and improve uncertainties by ca. an order of magnitude in the potassium isotopic compositions of standards.

Morgan, Leah↗

High-Performance X-ray Detection in a New Analytical Electron Microscope

X-ray detection by energy-dispersive spectrometry in the analytical electron microscope (AEM) is often limited by low collected X-ray intensity (P), modest peak-to-background (P/B) ratios, and limitations on total counting time (tau) due to specimen drift and contamination. A new AFM has been designed with maximization of P. P/B, and tau as the primary considerations. Maximization of P has been accomplished by employing a field-emission electron gun, X-ray detectors with high collection angles, high-speed beam blanking to allow only one photon into the detector at a time, and simultaneous collection from two detectors. P/B has been maximized by reducing extraneous background signals generated at the specimen holder, the polepieces and the detector collimator. The maximum practical tau has been increased by reducing specimen contamination and employing electronic drift correction. Performance improvments have been measured using the NIST standard Cr thin film. The 0-3 steradian solid angle of X-ray collection is the highest value available. The beam blanking scheme for X-ray detection provides 3-4 times greater throughput of X-rays at high count rates into a recorded spectrum than normal systems employing pulse-pileup rejection circuits. Simultaneous X-ray collection from two detectors allows the highest X-ray intensity yet recorded to be collected from the NIST Cr thin film. The measured P/B of 6300 is the highest level recorded for an AEM. In addition to collected X-ray intensity (cps/nA) and P/B measured on the standard Cr film, the product of these can be used as a figure-of-merit to evaluate instruments. Estimated minimum mass fraction (MMF) for Cr measured on the standard NIST Cr thin film is also proposed as a figure-of-merit for comparing X-ray detection in AEMs. Determinations here of the MMF of Cr detectable show at least a threefold improvement over previous instruments.

Lyman, C. E.↗

The Prediction Properties of Inverse and Reverse Regression for the Simple Linear Calibration Problem

The calibration of measurement systems is a fundamental but under-studied problem within industrial statistics. The origins of this problem go back to basic chemical analysis based on NIST standards. In today's world these issues extend to mechanical, electrical, and materials engineering. Often, these new scenarios do not provide "gold standards" such as the standard weights provided by NIST. This paper considers the classic "forward regression followed by inverse regression" approach. In this approach the initial experiment treats the "standards" as the regressor and the observed values as the response to calibrate the instrument. The analyst then must invert the resulting regression model in order to use the instrument to make actual measurements in practice. This paper compares this classical approach to "reverse regression," which treats the standards as the response and the observed measurements as the regressor in the calibration experiment. Such an approach is intuitively appealing because it avoids the need for the inverse regression. However, it also violates some of the basic regression assumptions.

Parker, Peter A.↗

Quantifying Cybersecurity Risk for NASA Missions

An end-to-end cyber risk assessment process is presented that is based on the combination of guidelines from the National Institute of Standards & Technology (NIST), the standard 5x5 risk matrix, and quantitative methods for generating loss exceedance curves. The NIST guidelines provide a framework for cyber risk assessment, and the standard 5x5 matrix is widely used across the industry for the representation of risk across multiple disciplines. Loss exceedance curves are a means of quantitatively assessing the loss that occurs due to a given risk profile. Combining these different techniques enables us to follow the guidelines, adhere to standard 5x5 risk management practices and develop quantitative metrics simultaneously. Our quantification process is based on the consideration of the NASA and JPL Cost Risk assessment modeling techniques as we define the cost associated with the cybersecurity risk profile of a mission as a function of the mission cost.

Miller, Robert L.↗

Numeric data distribution: The vital role of data exchange in today's world

The major aim of the NIST standard Reference Data Program (SRD) is to provide critically evaluated numeric data to the scientific and technical community in a convenient and accessible form. A second aim of the program is to provide feedback into the experimental and theoretical programs to help raise the general standards of measurement. By communicating the experience gained in evaluating the world output of data in the physical sciences, NIST/SRD helps to advance the level of experimental techniques and improve the reliability of physical measurements.

Chase, Malcolm W.↗

Results and Lessons from MODIS Thermal Emissive Bands Calibration: Pre-launch to On-orbit

MODIS is a major instrument for the NASA EOS Terra (launched in December 1999) and Aqua (launched in May 2002) missions. It was designed and built to enhance and extend its heritage sensors' measurements and data records with applications covering a wide range of studies of the Earth's land, oceans, and atmosphere. Its 16 thermal emissive bands (TEB), each with 10 detectors, are located on the two cold focal plane assemblies (FPAs) controlled by a passive radiative cooler. Because of instrument design complexity and stringent calibration requirements, extensive calibration and characterization activities were conducted pre-launch by the sensor vendor for both Terra and Aqua MODIS. For TEB, these activities include characterization of detectors' noise and non-linearity and evaluation of their radiometric performance in thermal vacuum at difference instrument temperatures and FPA temperatures. In addition TEB system level response versus scan-angle (RVS) and relative spectral response (RSR) were characterized. MODIS TEB radiometric calibration transfer from pre-launch to on-orbit was performed using spectral bands' responses to the instrument on-board blackbody and a laboratory blackbody calibration source (BCS) traceable to NIST standards. This paper provides a summary of MODIS TEB pre-launch and on-orbit calibration and characterization activities, challenges, data analysis results, and lessons learned with focus on sensors' radiometric performance. A comparison between Terra and Aqua MODIS TEB performance is also presented. A similar summary for the reflective solar bands (RSB) is reported in a separate paper in these proceedings.

Xiong, X.↗

The Landsat Data Continuity Mission Operational Land Imager (OLI) Radiometric Calibration

The Operational Land Imager (OLI) on the Landsat Data Continuity Mission (LDCM) has a comprehensive radiometric characterization and calibration program beginning with the instrument design, and extending through integration and test, on-orbit operations and science data processing. Key instrument design features for radiometric calibration include dual solar diffusers and multi-lamped on-board calibrators. The radiometric calibration transfer procedure from NIST standards has multiple checks on the radiometric scale throughout the process and uses a heliostat as part of the transfer to orbit of the radiometric calibration. On-orbit lunar imaging will be used to track the instruments stability and side slither maneuvers will be used in addition to the solar diffuser to flat field across the thousands of detectors per band. A Calibration Validation Team is continuously involved in the process from design to operations. This team uses an Image Assessment System (IAS), part of the ground system to characterize and calibrate the on-orbit data.

Markham, Brian L.↗

The Effects of High-Temperature Fractional Crystallization on Calcium Isotopic Composition

We report Ca isotope fractionation among a co-genetic suite of samples from the Mauritanian Guelb el Azib ultramafic-mafic-anorthosite complex (GAC), which represents the fractional crystallization sequence of an igneous magma chamber. We investigate how the composition of an evolving crystallizing liquid and the resultant mineralogy of co-crystallizing assemblages affects inter-phase Ca isotope fractionation. Because the GAC is an Archean metamorphosed complex, we first investigate the resistance of the Ca isotope signature to secondary hydrothermal alteration and to metamorphism. While we cannot conclude here that Ca isotopes are undisturbed at the mineral scale, we show that they are preserved at the bulk rock scale. This is adequate for our study where several samples are almost monomineralic at the bulk scale level. The δ(exp 44/40)Ca (relative to NIST standard SRM 915a) of GAC layers range from −1.53 to 1.61‰, with the earliest-formed ultramafic cumulate layer being isotopically heaviest and the later, more felsic layers being isotopically lighter. For the first time, we show that plagioclase is much more enriched in light Ca isotopes compared to olivine and (Ca-) pyroxene. Monte Carlo simulations suggest that Ca isotopes are fractionated among co-existing silicate minerals during fractional crystallization, possibly in relation with the residual liquid composition. In qualitative agreement with computational models based on first principles lattice dynamics, we observe that Ca isotope fractionation is mineralogically controlled and importantly, that the degree of fractionation can vary according to the CaO composition of the residual liquid. While previous studies have aimed to understand partial melting as a source of Ca isotope fractionation, our results suggest that fractional crystallization is also a source of Ca isotope variability among co-genetic samples.

Maria C. Valdes↗

On-Orbit Calibration and Performance Assessments of Terra and Aqua Modis Thermal Emissive Bands

Terra and Aqua MODIS have successfully operated for more than 20 and 18 years, respectively, and far exceeded their designed lifetimes of 6 years. MODIS has 36 spectral bands, among which 16 are the thermal emissive bands (TEB) covering a wavelength range from 3.75 to 14.24 μm. Observations from the MODIS TEB have been used to generate a number of data products, such as surface/cloud/atmospheric temperatures, cloud top altitude, and water vapor properties. To a large extent, the quality of the MODIS L1B radiance product has been maintained through the entirety of each mission via extensive on-orbit calibration and validation efforts. MODIS TEB calibration uses a quadratic algorithm and is referenced to an on-board blackbody with its temperature measurements traceable to the NIST standard. We provide an overview of the MODIS instrument operations, key TEB calibration activities, and algorithms used in the latest L1B data Collection 6.1 (C6.1) and describe the TEB on-orbit performance for both Terra and Aqua MODIS. The TEB gain trends have been stable to within 5% over the Terra mission after 2003 under the same electronic configuration, except for bands 27 to 30, and within 3% over the Aqua mission. The Terra MODIS optical crosstalk correction implemented right after launch has been very effective in removing the ghost images in its photoconductive detector bands 32 to 36. Starting from C6.1, an electronic crosstalk correction algorithm has also been applied to the Terra MODIS photovoltaic detector long-wave infrared bands 27 to 30. The noise characterization performance remains stable with most TEB detectors continuously meeting their design requirements. A gradual loss of the Aqua MODIS radiative cooler margin reached its maximum in 2013 and has been slowly recovering since then. On-orbit changes in TEB response versus scan angle are extremely small based on pitch maneuver observations and assessments using vicarious approaches. The remaining challenges in TEB calibration and proposed improvements for the upcoming data collection with L1B data production and reprocessing are discussed.

Terra↗

Activities of NIST (National Inst. of Standards and Technology)

The Radiometric Physics Division of the NIST is responsible for the national standards in radiation thermometry, spectroradiometry, photometry, and spectrophotometry; dissemination of these standards by providing measurement services to customers requiring calibrations of the highest accuracy; and conducting fundamental and applied research to develop the scientific basis for future measurement services. Its relevance to EOS/TIR calibration includes calibrating unknown blackbody for radiance using a well-characterized NIST blackbody source by matching the radiant fluxes with an IR radiometer. The TIR Round Robin is used to verify the calibration of the sources that are used for the absolute radiometric calibration of the individual EOS sensors.

Source record↗

Microwave digestion preparation and ICP determination of boron in human plasma

A microwave digestion procedure, followed by Inductively Coupled Argon Plasma Spectroscopy, is described for the determination of boron (B) in human plasma. The National Institute of Standards and Technology (NIST) currently does not certify the concentration of B in any substance. The NIST citrus leaves 1572 (CL) Standard Reference Material (SRM) and wheat flour 1567a (WF) were chosen to determine the efficacy of digestion. CL and WF values compare favorably to those obtained from an open-vessel, wet digestion followed by ICP, and by neutron activation and mass spectrometric measurements. Plasma samples were oxidized by doubled-distilled ultrapure HNO3 in 120 mL PFA Teflon vessels. An MDS-81D microwave digestion procedure allows for rapid and relatively precise determination of B in human plasma, while limiting handling hazards and sources of contamination.

Ferrando, A. A.↗

Low level measurements of atmospheric DMS, H2S, and SO2 for GTE/CITE-3

This project involved the measurement of atmospheric dimethylsulfide (DMS) and hydrogen sulfide (H2S) as part of the GTE/CITE-3 instrument intercomparison program. The two instruments were adapted for use on the NASA Electra aircraft and participated in all phases of the mission. This included ground-based measurements of NIST-provided standard gases and a series of airborne missions over the Western Atlantic Ocean. Analytical techniques used are described and the results are summarized.

Saltzman, Eric↗

Strain Gauge Balance Calibration and Data Reduction at NASA Langley Research Center

This paper will cover the standard force balance calibration and data reduction techniques used at Langley Research Center. It will cover balance axes definition, balance type, calibration instrumentation, traceability of standards to NIST, calibration loading procedures, balance calibration mathematical model, calibration data reduction techniques, balance accuracy reporting, and calibration frequency.

Ferris, A. T. Judy↗