Identifying the Molecular Origin of Global Warming

We have investigated the physical characteristics of greenhouse gases (GHGs) to assess which properties are most important in determining the efficiency of a GHG. Chlorofluorcarbons (CFCs), hydrofluorocarbons (HFCs), perfluorocarbons (PFCs), nitrogen fluorides, and various other known atmospheric trace molecules have been included in this study. Compounds containing the halogens F or Cl have in common very polar X-F or X-Cl bonds, particularly the X-F bonds. It is shown that as more F atoms bond to the same central atom, the bond dipoles become larger as a result of the central atom becoming more positive. This leads to a linear increase in the total or integrated XF bond dipole derivatives for the molecule, which leads to a non-linear (quadratic) increase in infrared (IR) intensity. Moreover, virtually all of the X-F bond stretches occur in the atmospheric IR window as opposed to X-H stretches, which do not occur in the atmospheric window. It is concluded that molecules possessing several F atoms will always have a large radiative forcing parameter in the calculation of their global warming potential. Some of the implications for global warming and climate change are discussed.

Bera, Partha P.↗

Zinc, copper, and nitrogen balances during bed rest and fluoride supplementation in healthy adult males

The effects of bed rest and fluoride supplementation on zinc, copper, and nitrogen balances and Zn and Cu serum levels were measured in 15 healthy males. Subjects aged 19-54 y remained on a metabolic research ward for 10 wk. During weeks 1-5, subjects were ambulatory. During wks 6-10 they remained in continuous bed rest. During weeks 3-10 nine subjects received 10 or 20 mg F/d as sodium fluoride. Daily urine and weekly fecal composites were made and biweekly fasting blood samples were taken. Dietary intakes were 1.40 +/- 0.17 mg Cu/d (22.0 +/- 2.7 mumol Cu/d), 10.82 +/- 0.49 mg Zn/d (165.6 +/- 7.6 mumol Zn/d), and 14.27 +/- 0.23 g N/d (1019 +/- 16 mmol N/d). Bed rest increased urinary Zn and N excretions and fecal Zn excretions and decreased Zn balance (p less than 0.05) whereas Cu balance was unchanged. During bed rest, F supplementation increased Zn and N balances compared with untreated control subjects (p less than 0.05). These results are compatible with bone and muscle atrophy during bed rest and increased bone formation with F supplementation.

Clinical Trial↗

SHELL STABILITY PROBLEMS IN THE DESIGN OF LARGE SPACE VEHICLE BOOSTERS

A discussion of the current methods used to design the Saturn type booster shell structures is presented covering bending and axial compression, with and without internal pressure. Problem areas encountered in the application of available shell stability data to these designs are delineated; as well as, suggested areas of future research for shell configurations anticipated in advanced designs.

LAUNCH VEHICLE↗

Investigation of effect of fluoride on corrosion of 2S-0 aluminum and 347 stainless steel in fuming nitric acid at 170 F

The effect of small additions of fluoride on the corrosion of 2S-0 aluminum and 347 stainless steel by fuming nitric acid at 170 degrees F has been evaluated quantitatively by the determination of the weight loss of metal specimens immersed in the acid. The ratio of metal surface area to volume of acid was approximately 7.5 inch (superscript)-1 in all cases. It was found that for acids containing no fluorides the weight loss of aluminum was approximately 1/5 that of stainless steel. Addition of 1 percent fluoride ion to the acid reduced the weight loss of both metals to practically zero even after 26 days of exposure to the acid at 170 degrees F. The minimum quantity of fluoride ion required to inhibit corrosion was found to be approximately 0.25 and 0.5 percent for aluminum and stainless steel, respectively, in white fuming nitric acid and 0.5 and 1 percent in red fuming nitric acid (18 percent nitrogen dioxide). These fluoride percentages were based on the total weight of acid. Provided the concentration of fluoride ion was sufficient to inhibit corrosion, the source of these ions was immaterial. Additional information concerning the effect of fluorides on corrosion was obtained by measuring the electrode potentials of the metals against a platinum reference electrode.

Feiler, Charles E↗

Toxic Hazards Research Unit

The activities of the Toxic Hazards Research Unit (THRU) for the period of June 1970 through May 1971 reviewed. Modification of the animal exposure facilities primarily for improved human safety but also for experimental integrity and continuity are discussed. Acute toxicity experiments were conducted on hydrogen fluoride (HF), hydrogen chloride (HCl), nitrogen dioxide (NO2), and hydrogen cyanide (HCN) both singly and in combination with carbon dioxide (CO). Additional acute toxicity experiments were conducted on oxygen difluoride (OF2) and chlorine pentafluoride (ClF5). Subacute toxicity studies were conducted on methylisobutylketone and dichloromethane (methylene dichloride). The interim results of further chronic toxicity experiments on monomethylhydrazine (MMH) are also described.

Macewen, J. D.↗

Analytical methods for toxic gases from thermal degradation of polymers

Toxic gases evolved from the thermal oxidative degradation of synthetic or natural polymers in small laboratory chambers or in large scale fire tests are measured by several different analytical methods. Gas detector tubes are used for fast on-site detection of suspect toxic gases. The infrared spectroscopic method is an excellent qualitative and quantitative analysis for some toxic gases. Permanent gases such as carbon monoxide, carbon dioxide, methane and ethylene, can be quantitatively determined by gas chromatography. Highly toxic and corrosive gases such as nitrogen oxides, hydrogen cyanide, hydrogen fluoride, hydrogen chloride and sulfur dioxide should be passed into a scrubbing solution for subsequent analysis by either specific ion electrodes or spectrophotometric methods. Low-concentration toxic organic vapors can be concentrated in a cold trap and then analyzed by gas chromatography and mass spectrometry. The limitations of different methods are discussed.

Hsu, M.-T. S.↗

Screenable silver and base metal solar cell contacts

The metallurgical soundness of the all-metal screenable thick film electrode system is established for silver and copper electrodes. Silver fluoride was identified as a successful etchant material and is found most effective in the liquid phase (435-460 C). Best results were achieved with the eutectic alloys of dopants and semiconductors. The air-fired silver inks were strongly adherent, rugged, and solderable, whereas the hydrogen-fired silver inks had very poor adhesion. A two-step firing process was devised in which copper inks containing silver fluoride were activated in a nitrogen atmosphere, with sintering done at the same or higher temperatures in hydrogen. Good solar cells were made using the copper paste back contacts demonstrating that the electrodes are not the limiting factors in efficiency.

Ross, B.↗

Design and performance of the halogen occultation experiment (HALOE) remote sensor

HALOE is an optical remote sensor that measures extinction of solar radiation caused by the earth's atmosphere in eight channels, ranging in wavelength from 2.5 to 10.1 microns. These measurements, which occur twice each satellite orbit during solar occultation, are inverted to yield vertical distributions of middle atmosphere ozone (O3), water vapor, nitrogen dioxide, nitric oxide, hydrogen fluoride, hydrogen chloride, and methane. A channel located in the 2.7 region is used to infer the tangent point pressure by measuring carbon dioxide absorption. The HALOE instrument consists of a two-axis gimbal system, telescope, spectral discrimination optics and a 12-bit data system. The gimbal system tracks the solar radiometric centroid in the azimuthal plane and tracks the solar limb in the elevation plane, placing the instrument's instantaneous field-of-view 4 arcmin down from the solar top edge. The instrument gathers data for tangent altitudes ranging from 150 km to the earth's horizon. Prior to an orbital sunset and after an orbital sunrise, HALOE automatically performs calibration sequences to enhance data interpretation. The instrument is presently being tested at the NASA Langley Research Center in preparation for launch on the Upper Atmosphere Research Satellite near the end of this decade. This paper describes the instrumenmt design, operation, and functional performance.

Baker, R. L.↗

Industrial Applications of Graphite Fluoride Fibers

Based on fluorination technology developed during 1934 to 1959, and the fiber technology developed during the 1970s, a new process was developed to produce graphite fluoride fibers. In the process, pitch based graphitized carbon fibers are at first intercalated and deintercalated several times by bromine and iodine, followed by several cycles of nitrogen heating and fluorination at 350 to 370 C. Electrical, mechanical, and thermal properties of this fiber depend on the fluorination process and the fluorine content of the graphite fluoride product. However, these properties are between those of graphite and those of PTFE (Teflon). Therefore, it is considered to be a semiplastic. The physical properties suggest that this new material may have many new and unexplored applications. For example, it can be a thermally conductive electrical insulator. Its coefficient of thermal expansion (CTE) can be adjusted to match that of silicon, and therefore, it can be a heat sinking printed circuit board which is CTE compatible with silicon. Using these fibers in printed circuit boards may provide improved electrical performance and reliability of the electronics on the board over existing designs. Also, since it releases fluorine at 300 C or higher, it can be used as a material to store fluorine and to conduct fluorination. This application may simplify the fluorination process and reduce the risk of handling fluorine.

Hung, Ching-Cheh↗

Effects of Humidity On the Flow Characteristics of PS304 Plasma Spray Feedstock Powder Blend

The effects of environmental humidity on the flow characteristics of PS304 feedstock have been investigated. Angular and spherical BaF2-CaF2 powder was fabricated by comminution and by atomization, respectively. The fluorides were added incrementally to the nichrome, chromia, and silver powders to produce PS304 feedstock. The powders were dried in a vacuum oven and cooled to a Tom temperature under dry nitrogen. The flow of the powder was studied from 2 to 100 percent relative humidity (RH) The results suggest that the feedstock flow is slightly degraded with increasing humidity below 66 percent RH and is more affected above 66 percent RH. There was no flow above 88 percent RH. Narrower particle size distributions of the angular fluorides allowed flow up to 95 percent RH. These results offer guidance that enhances the commercial potential for this material system.

Stanford, Malcolm K.↗

A survey of laser and selected optical systems for remote measurement of pollutant gas concentrations

Applications of the Differential Absorption Lidar (DIAL) technique to the remote sensing of pollutant gases are surveyed. In the DIAl technique, the differential absorption of two laser beams reflected back to a receiver from a target determines the concentration of the gas being studied. The types of instruments available are considered in detail: dye lidar (to measure nitrogen dioxide, sulfur dioxide, and ozone); carbon dioxide laser (for ozone, ethylene, ammonia, and hydrazine), helium-neon laser (for methane); hydrogen fluoride laser (for HF); and tunable diode laser (for nitric oxide and carbon monoxide). DIAL instruments are compared with other optical remote sensors such as Fourier-transform infrared spectrometers, correlation spectrometers (COSPEC and GASPEC), and grating spectrometers; and criteria for the selection of an appropriate gas measuring system are suggested. Laser and other optical remote sensors are found to be cost effective in many cases, despite the fact that they are more costly than point-monitoring systems.

Grant, W. B.↗

Analysis of a Radioisotope Thermal Rocket Engine

The Triton Hopper is a concept for a global hopper vehicle which uses a radioisotope rocket engine and In-situ propellant acquisition to explore the surface of Neptune's moon, Triton. The current Triton Hopper concept stores heated Nitrogen in a spherical tank to be used as the propellant. The aim of the research was to investigate the benefits of storing propellant at ambient temperature and heating it through the use of a thermal block during engine operation, as opposed to storing gas at a high temperature. Lithium, Lithium Fluoride and Beryllium were considered as possible materials for the thermal block. A heat energy analysis indicated that a lithium thermal mass would provide the highest heat energy for a temperature change from 900 Celsius to -100 Celsius. A heat transfer analysis was performed for Nitrogen at -100 Celsius flowing through 1000 passages inside a 1kg lithium thermal block at a temperature of 900 Celsius. The system was analyzed as turbulent flow through a tube with constant surface temperature. The analysis indicated that the propellant reached a maximum temperature of 877 Celsius before entering the nozzle. At this exit temperature, the average specific impulse [I(sub sp)] of the engine was determined to be 157s. Previous studies for the stored heated gas concept suggest that the engine would have an average I(sub sp) of approximately 52s. Thus, the use of a thermal block concept results in a 200 percent engine performance increase. In addition, a tank sizing study was performed to determine if the concept is feasible in terms of mass requirements. The mass for a spherical carbon fiber COPV storing 35kg of nitrogen at an initial temperature of -100 Celsius and a pressure of 1000psia, was determined to be 7.2kg. The specific impulse analysis indicated that the maximum engine performance is obtained for a mass ratio of 5kg of Nitrogen per every 1kg of lithium thermal mass. Thus for 35kg of Nitrogen the total thermal mass would be 7kg. This brings the total mass of the system to 49.2.kg which is less than the 56kg landing payload capacity of the Triton Hopper. Finally, an insulation analysis using 10mm of MLI insulation indicated that a total of 22 watts of heat are lost to the environment. With the heat loss known, the power required to heat the thermal mass to 900 Celsius in 24 days was determined to be 2.15 watts. The study's results allowed us to conclude that the thermal mass concept is the better option due to the performance increase provided, the low power requirement and its compliance with the landing mass requirement of the Triton Hopper.

Radioisotope↗

Enriched Storable Oxidizers for Rocket Engines

The name "enriched storable oxidizers" (ESOs) has been coined for a family of optimized mixtures of between two and four oxidizer fluids. For most applications, the constituents of these mixtures would be nitrogen tetroxide (N2O4), nitrous oxide (N2O), and nitrogen dioxide (NO2); in some applications, the mixtures might include inhibited red fuming nitric acid [IRFN (which consists of red fuming nitric acid to which some hydrogen fluoride is added to reduce its corrosive effect]. The optimum proportions of these constituents would be different for different applications. ESOs were originally proposed for use in spacecraft and launch-rocket propulsion systems: ESOs could be especially useful in advanced spacecraft propulsion systems that could operate in multiple modes. ESOs might also be useful in special terrestrial applications that could include ramjet and scramjet aircraft engines.

Sackheim, R. L.↗

Intercalation of Lithium in Pitch-Based Graphitized Carbon Fibers Chemically Modified by Fluorine: Soft Carbon With or Without an Oxide Surface

The effects of carbon structure and surface oxygen on the carbon's performance as the anode in lithium-ion battery were studied. Two carbon materials were used for the electrochemical tests: soft carbon made from defluorination of graphite fluoride, and the carbon precursor from which the graphite fluoride was made. In this research the precursor was graphitized carbon fiber P-100. It was first fluorinated to form CF(0.68), then defluorinated slowly at 350 to 450 C in bromoform, and finally heated in 1000 C nitrogen before exposed to room temperature air, producing disordered soft carbon having basic surface oxides. This process caused very little carbon loss. The electrochemical test involved cycles of lithium intercalation and deintercalation using C/saturated LiI-50/50 (vol %) EC and DMC/Li half cell. The cycling test had four major results. (1) The presence of a basic oxide surface may prevent solvent from entering the carbon structure and therefore prolong the carbon's cycle life for lithium intercalation-deintercalation. (2) The disordered soft carbon can store lithium through two different mechanisms. One of them is lithium intercalation. which gives the disordered carbon an electrochemical behavior similar to its more ordered graphitic precursor. The other is unknown in its chemistry, but is responsible for the high-N,oltage portion (less than 0.3V) of the charge-discharge curve. (3) Under certain conditions, the disordered carbon can store more lithium than its precursor. (4) These sample and its precursor can intercalate at 200 mA/g. and deintercalate at a rate of 2000 mA/g without significant capacity loss.

Hung, Ching-Chen↗

Improved thermoelectrically cooled quartz crystal microbalance

Design changes in the thermoelectrically-cooled quartz microbalance, which is used to monitor surface contamination in space simulation chambers, is described in terms of its extended temperature range, increased temperature control, mass sensitivity, and cooling power. The mass sensor uses 20 MHz quartz crystals having a sensitivity of 8.8 x 10 to the minus tenth power g/sq cm - Hz. The crystals are optically polished, metal plated, and overplated with magnesium fluoride to simulate an optical surface. The microbalance temperature circuitry is designed to readout and control surface temperature between 100 C and minus 59 C to plus or minus 0.5 C, and readout only temperature between minus 60 C and minus 199 C using auxiliary liquid nitrogen cooling. Data is included on the measurement of oil contamination of surfaces as a function of temperature in space simulation chambers.

D. McKeown↗