Search NASASearch

SEARCH · Search NASA

Results for “NOISE INTENSITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Near-infrared noise in intense electron bunches

This article investigates electron bunch density fluctuations in the 1 −10 μ⁢m wavelength range, focusing on their impact on coherent electron cooling (CEC) in hadron storage rings. In this study, we compare the shot-noise model with experimental observations using bandwidth-filtered near-infrared optical transition radiation (OTR) photodiode signals, where the transverse bunch size is much larger than the OTR wavelength of interest. The relativistic electron bunch (𝛾 ≈ 50) parameters are close to those proposed for the coherent electron cooler in the electron-ion collider (EIC) project. Preliminary feasibility experiments were conducted, and the noise factors are presented, supported by particle tracking. No major density fluctuations or effective cooling rate decrease were revealed for EIC CEC design parameters. Additionally, longitudinal-space-charge-induced microbunching for the chicane-compressed bunch was observed with coherent OTR enhancements up to 100 times, providing further calibration of the measurement method.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Noise in Intense Electron Bunches (Final Technical Report)

The goal of this project is to investigate density fluctuations in electron bunches. Noise and density fluctuations in relativistic electron bunches, accelerated in a linac, are of critical importance to various Coherent Electron Cooling (CEC) concepts as well as to free-electron lasers (FELs). For CEC, the beam noise results in additional diffusion that counteracts cooling; and if this noise is not controlled at sufficiently low level, the noise heating effects can overcome cooling. There have been several proposals in the past to suppress the noise in the beam in the frequency range of interest in order to optimize the cooling effects. In SASE FELs a microwave instability starts from the initial noise in the beam and eventually leads to the beam microbunching yielding coherent radiation, and the initial noise in the FEL bandwidth plays a useful role. In seeded FELs, in contrast, such noise interferes with the seed signal, so that reducing noise at the initial seed wavelength would lower the seed laser power requirement. Our major goals were (1) to measure the electron beam density noise level in a 0.5 – 10 um wavelength range, (2) to predict the beam noise level in order to compare with the measurements, and (3) as a stretch goal, to find mechanisms that affect the beam noise to control its level in a predictable manner.

43 PARTICLE ACCELERATORS

Bi-chromatic intensity squeezing using four-wave mixing in 85 Rb vapor

We experimentally investigate four-wave mixing (FWM) in a diamond interaction scheme using 85 Rb vapor, and identify the optimal conditions for joint amplification and relative intensity squeezing of two optical fields: one near the 85 Rb D1 optical transition (λ = 794.6 nm) and the other in the telecom O-band (λ = 1324 nm). We achieved a reduction of relative intensity noise by up to 2.6 ± 0.4 dB compared with the shot noise level, signifying the non-classical quantum correlations. The observed level of intensity squeezing is primarily limited by the available pump laser power, which constrains the achievable FWM gain. Numerical simulations show good agreement with the experimental results.

74 ATOMIC AND MOLECULAR PHYSICS

High-Power Clock Laser Spectrally Tailored for High-Fidelity Quantum State Engineering

Highly frequency-stable lasers are ubiquitous tools for optical-frequency metrology, precision interferometry, and quantum information science. While making a universally applicable laser is unrealistic, spectral noise can be tailored for specific applications. Here we report a high-power 698-nm clock laser with a maximum output of 4W and minimized frequency noise up to a few kHz Fourier frequency, together with long-term instability of 3.5 × 10 −17 at one to thousands of seconds. The laser-frequency noise is precisely characterized with atom-based spectral analysis that employs a pulse sequence designed to suppress sensitivity to intensity noise. This method provides universally applicable tunability of the spectral response and analysis of quantum sensors over a wide frequency range. With the optimized laser system characterized by this technique, we achieve an average single-qubit Clifford gate fidelity of up to 𝐹$^2_1$ = 0.999⁢64⁢(3) when simultaneously driving 3000 optical qubits with a homogeneous Rabi frequency ranging from 10 Hz to 1 kHz. This result represents the highest single optical-qubit-gate fidelity for a large number of atoms.

atomic gases

High-Performance Near-Infrared Quantum Emission from Color Centers in hBN

Color centers hosted in hexagonal boron nitride (hBN) have emerged as a highly promising platform for single-photon emission and spin-photon technologies relevant to quantum communication and quantum networking. As a wide bandgap van der Waals material, hBN can host optically active quantum defects across a broad spectral range. Here, we demonstrate a simple and scalable oxygen-plasma process that reproducibly creates single quantum emitters in hBN with blinking-free zero-phonon lines (ZPLs) spanning near-infrared (NIR) from 700 up to 971 nm. These emitters combine MHz-level brightness, single-photon purity up to 99.9%, and ultranarrow cryogenic line widths down to 2.7 GHz under quasi-resonant excitation, placing them in a particularly attractive regime for quantum photonics. Photostability measurements further reveal resistance to photobleaching, subnanometer spectral stability over long time scales, and near-shot-noise-limited intensity fluctuations. Analysis of the phonon sidebands shows weak vibronic coupling and ZPL-dominated emission, with Debye–Waller factors approaching 50%. Control experiments together with elemental mapping support oxygen incorporation as a necessary ingredient in activating the NIR emitter population, while first-principles calculations identify O N V N and O N V N H as the leading defect candidates. These results establish a high-performance NIR quantum-emitter platform in hBN for free-space quantum networking and future integrated quantum-photonic architectures.

2D materials

Bayesian Gaussian process inference for neutron spin echo measurement

Neutron spin echo (NSE) spectroscopy provides unique access to microscopic dynamics, but its application is often constrained by low neutron flux, long acquisition times, and significant noise. Here, we present a Bayesian inference approach based on Gaussian process regression (GPR) to reconstruct high-quality spin echo signals from sparse and noisy data by exploiting correlations in reciprocal space. Benchmarks on synthetic datasets and validation with experimental NSE measurements of dendrimers show that GPR suppresses noise, interpolates missing intensity values, and accommodates irregular observations. The method improves accuracy, shortens acquisition times, and enables high-throughput and real-time studies. Beyond NSE, the framework is broadly applicable to other low signal-to-noise ratio scattering techniques, thereby extending the scope of neutron spectroscopy.

Tung, Chi-Huan [Oak Ridge National Laboratory (ORN

Unlocking hidden information in sparse small-angle neutron scattering measurements

Hypothesis Small-Angle Neutron Scattering (SANS) is a powerful technique for studying soft matter systems such as colloids, polymers, and lyotropic phases, providing nanoscale structural insights. However, its effectiveness is limited by low neutron flux, leading to long acquisition times and noisy data. Here, we hypothesize that Bayesian statistical inference using Gaussian Process Regression (GPR) can reconstruct high-fidelity scattering data from sparse measurements by leveraging intensity smoothness and continuity. Experiments and Simulations The method was benchmarked computationally and validated through SANS experiments on various soft matter systems, including wormlike micelles, colloidal suspensions, polymeric structures, and lyotropic phases. GPR-based inference was applied to both experimental and synthetic data to evaluate its effectiveness in noise reduction and intensity reconstruction. Findings GPR significantly enhances SANS data quality and therefore reducing measurement times by up to two orders of magnitude. This cost-effective approach maximizes experimental efficiency, enabling high-throughput studies and real-time monitoring of dynamic systems. It is particularly beneficial for weakly scattering and time-sensitive studies. Beyond SANS, this framework applies to other low-SNR techniques, including laboratory-based small-angle X-ray scattering and various dynamical scattering methods. Furthermore, it offers transformative potential for compact neutron sources, enhancing their viability for structural analysis in resource-limited settings.

Small angle neutron scattering

The Stochastic Gause Predator-Prey model: Noise-induced extinctions and invariance

We consider the Gause predator-prey with general bounded or sub‑linear functional responses, – which includes those of Holling types Ⅰ–Ⅳ. – and multiplicative Gaussian noise. In contrast to previous studies, the prey in our model follows logistic dynamics while the predator's population is solely regulated by consumption of the prey. To ensure well-posedeness, we derive explicit Lyapunov‐type criteria ensuring global positivity and moment boundedness of solutions. We find conditions for noise‑induced extinctions, proving that stochasticity can drive either population to collapse even when the deterministic analogue predicts stable coexistence. In the case when the predator becomes extinct, we establish a limiting distribution for the predator's population. Last, for functional responses of Holling type Ⅰ, we provide sufficient conditions on the intensity of the noise for the existence and uniqueness of a stationary distribution.

Gause model

Improving cosmological analyses of HI clustering by reducing stochastic noise

High-number-density tracers of large-scale structure, such as the HI-rich galaxies measured by 21 cm intensity mapping, have low sampling noise, making them particularly promising as cosmological probes. At large scales, this sampling noise can be subdominant to other scale-independent contributions to the power spectrum; such contributions arise from nonlinear bias, and exceed the sampling noise if at least one of the associated bias coefficients is sufficiently large. This has important consequences for cosmological constraints obtained from such tracers, since it indicates that using the power spectrum does not lead to optimal constraints even in the linear regime. In this paper, we provide a conservative estimate of the possible improvement in constraining power of a 21 cm survey if one were to use an optimal analysis strategy (such as field-level analysis), where only the true sampling noise enters the error budget. We find that improvements in uncertainties on some cosmological parameters can be as large as 50%, depending on redshift, foreground cleaning efficiency, scales used in the analysis, and instrumental noise. One byproduct of our work is measurements of bias parameters and stochasticity for neutral hydrogen in the IllustrisTNG simulation over a wide range of redshifts; we provide simple fitting formulas for these measurements. Furthermore, our results motivate further exploration of new optimal analysis techniques and provide important insights into the constraining power of current and future 21 cm surveys.

79 ASTRONOMY AND ASTROPHYSICS

Truncated nonlinear interferometer-based sensor system

A truncated non-linear interferometer-based sensor system includes an input port that receives an optical beam and a non-linear amplifier that amplifies the optical beam with a pump beam and renders a probe beam and a conjugate beam. The system's local oscillators have a relationship with the respective beams. The system includes a sensor that transduces an input with the probe beam and the conjugate beam or their respective local oscillators. It includes one or more phase-sensitive detectors that detect a phase modulation between the respective local oscillators and the probe beam and the conjugate beam. Output from the phase-sensitive-detectors is based on the detected phase modulation. The phase-sensor-detectors include measurement circuitry that measure the phase signals. The measurement is the sum or difference of the phase signals in which the measured combination exhibit a quantum noise reduction in an intensity difference or a phase sum or an amplitude difference quadrature.

Pooser, Raphael C.

A bi-level spatiotemporal clustering approach and its application to drought extraction

We present a novel flexible bi-level spatiotemporal clustering algorithm to extract events based on their intensity and spatiotemporal structures. Our algorithm consists of using (i) a novel space-time k-means clustering to obtain spatiotemporally coherent intensity clusters, and (ii) a density-based spatial clustering of applications with noise (DBSCAN) to spatiotemporally section the intensity clusters into individual events. We discuss the development of the algorithm, the selection, tuning and meaning of the parameters within each step, as well as its validation. Finally, we apply the algorithm to a spatiotemporal drought index, standardized vapor pressure deficit drought index (SVDI), over the continental United States (US) from 1980–2021 and show that it captures historical drought events over the continental United States and their spatiotemporal extents.

17 WIND ENERGY

Baltimore Social-Environmental Collaborative (BSEC) Doppler Lidar & Derived Products

This repository contains all processed Doppler‐lidar outputs from the PSU lidar deployed for the Baltimore Social‐Environmental Collaborative (BSEC) project. Vertical Stare Scans (fixed‐beam, vertical profiling): 1 Hz backscatter intensity (m⁻¹ sr⁻¹), signal‐to‐noise ratio (unitless), and Doppler vertical‐velocity (m s⁻¹) on ~30 m range gates, stored as CF-compliant NetCDF. Wind Profiles (horizontal‐wind retrieval): daily NetCDF outputs of retrieved horizontal wind speed (m s⁻¹) and direction (degrees), computed from the angled‐scan returns. Profile Statistics (summary statistics on the vertical velocity): 15 min windows (default) of mean, variance, skewness, kurtosis, high-frequency variance, etc., as a function of height; saved as CF-compliant NetCDF files. Boundary Layer Height (BLH) (fuzzy-logic output): 15 min BLH estimates (m), with lower/upper fuzzy bounds (m) and a quality flag (0–4) indicating data status (e.g., no data, good, below range, ran out of signal, cloud-topped). Cloud Base Height (Haar-gradient detection): 15 min estimates of cloud-base height (m) with a cloud-detection quality flag (0–3: none, low, moderate, high). All five product streams are organized by year and date under their own top-level folders (01_Vertical_Stare_Scans/ through 05_Cloud_Height/). Each folder contains a data_ /YYYY/ subdirectory with daily CF-compliant NetCDF outputs (96 windows per day at 15 min intervals). Global attributes in each file include creation history, version (2.0.0), institution, and source. Instrument & MeasurementsThe PSU Doppler Lidar samples aerosol backscatter (m⁻¹ sr⁻¹), signal-to-noise ratio, and radial velocity at ~1 Hz. Vertical stare scans point the beam straight up; after collecting angled scans through multiple elevation angles, the "Wind Profiles" product contains the fully retrieved horizontal wind speed and direction. Data were collected continuously at ~30 m range resolution, with a typical height ceiling of ~12 km. How to Use Open any NetCDF with Python's xarray, MATLAB, or similar CF-compliant tools. Stare scans and angled-scan retrievals (Wind Profiles) are CF-compliant daily NetCDF files. Profile-Statistics, BLH, and Cloud Height files are daily 15 min summaries (96 time steps per file). Inspect the included variables (e.g., vertical_velocity_variance, wind_speed, BLH, cloud_base_height) for your analyses. Use the quality flags (BLH_flag, cloud_flag) to filter out poor-quality retrievals. For more information or questions about processing methods, please contact:Nicholas E. Prince ⟨nec5299@psu.edu⟩Penn State Department of Meteorology & Atmospheric Science

Air Quality

Baltimore Social-Environmental Collaborative (BSEC) Doppler Lidar & Derived Products

This repository contains all processed Doppler‐lidar outputs from the PSU lidar deployed for the Baltimore Social‐Environmental Collaborative (BSEC) project. Vertical Stare Scans (fixed‐beam, vertical profiling): 1 Hz backscatter intensity (m⁻¹ sr⁻¹), signal‐to‐noise ratio (unitless), and Doppler vertical‐velocity (m s⁻¹) on 30 m range gates (and 3 m range gates), stored as CF-compliant NetCDF. Wind Profiles (horizontal‐wind retrieval): daily NetCDF outputs of retrieved horizontal wind speed (m s⁻¹) and direction (degrees), computed from the angled‐scan returns. Profile Statistics (summary statistics on the vertical velocity): 15 min windows (default) of mean, variance, skewness, kurtosis, high-frequency variance, etc., as a function of height; saved as CF-compliant NetCDF files. Boundary Layer Height (BLH) (fuzzy-logic output): 15 min BLH estimates (m), with lower/upper fuzzy bounds (m) and a quality flag (0–4) indicating data status (e.g., no data, good, ran out of signal, below range, cloud-topped). Cloud Base Height (Haar-gradient detection): 10 min estimates of cloud-base height (m). All five product streams are organized by year and date under their own top-level folders (01_Vertical_Stare_Scans/ through 05_Cloud_Height/). Each folder contains a data_ /YYYY/ subdirectory with daily CF-compliant NetCDF outputs (96 windows per day at 15 min intervals). Global attributes in each file include creation history, version (3.0.0), institution, and source. Instrument & MeasurementsThe PSU Doppler Lidar samples aerosol backscatter (m⁻¹ sr⁻¹), signal-to-noise ratio, and radial velocity at ~1 Hz. Vertical stare scans point the beam straight up; after collecting angled scans through multiple elevation angles, the "Wind Profiles" product contains the fully retrieved horizontal wind speed and direction. Data were collected continuously at ~30 m range resolution (and 3 m for the year of 2025), with a typical height ceiling of ~12 km. How to Use Open any NetCDF with Python's xarray, MATLAB, or similar CF-compliant tools. Stare scans and angled-scan retrievals (Wind Profiles) are CF-compliant daily NetCDF files. Profile-Statistics, BLH, and Cloud Height files are daily 15 min (10 min for Cloud Heights) summaries (96 time steps per file). Inspect the included variables (e.g., vertical_velocity_variance, wind_speed, BLH, cloud_base_height) for your analyses. Use the quality flags (BLH_flag, cloud_flag) to filter out poor-quality retrievals. For more information or questions about processing methods, please contact:Nicholas E. Prince ⟨nec5299@psu.edu⟩Penn State Department of Meteorology & Atmospheric Science

Air Quality

Baltimore Social-Environmental Collaborative (BSEC) Doppler Lidar & Derived Products

This repository contains all processed Doppler‐lidar outputs from the PSU lidar deployed for the Baltimore Social‐Environmental Collaborative (BSEC) project. Vertical Stare Scans (fixed‐beam, vertical profiling): 1 Hz backscatter intensity (m⁻¹ sr⁻¹), signal‐to‐noise ratio (unitless), and Doppler vertical‐velocity (m s⁻¹) on 30 m range gates (and 3 m range gates), stored as CF-compliant NetCDF. Wind Profiles (horizontal‐wind retrieval): daily NetCDF outputs of retrieved horizontal wind speed (m s⁻¹) and direction (degrees), computed from the angled‐scan returns. Profile Statistics (summary statistics on the vertical velocity): 15 min windows (default) of mean, variance, skewness, kurtosis, high-frequency variance, etc., as a function of height; saved as CF-compliant NetCDF files. Boundary Layer Height (BLH) (fuzzy-logic output): 15 min BLH estimates (m), with lower/upper fuzzy bounds (m) and a quality flag (0–4) indicating data status (e.g., no data, good, ran out of signal, below range, cloud-topped). Cloud Base Height (Haar-gradient detection): 10 min estimates of cloud-base height (m). All five product streams are organized by year and date under their own top-level folders (01_Vertical_Stare_Scans/ through 05_Cloud_Height/). Each folder contains a data_ /YYYY/ subdirectory with daily CF-compliant NetCDF outputs (96 windows per day at 15 min intervals). Global attributes in each file include creation history, version (3.0.1), institution, and source. Instrument & MeasurementsThe PSU Doppler Lidar samples aerosol backscatter (m⁻¹ sr⁻¹), signal-to-noise ratio, and radial velocity at ~1 Hz. Vertical stare scans point the beam straight up; after collecting angled scans through multiple elevation angles, the "Wind Profiles" product contains the fully retrieved horizontal wind speed and direction. Data were collected continuously at ~30 m range resolution (and 3 m for the year of 2025), with a typical height ceiling of ~12 km. How to Use Open any NetCDF with Python's xarray, MATLAB, or similar CF-compliant tools. Stare scans and angled-scan retrievals (Wind Profiles) are CF-compliant daily NetCDF files. Profile-Statistics, BLH, and Cloud Height files are daily 15 min (10 min for Cloud Heights) summaries (96 time steps per file). Inspect the included variables (e.g., vertical_velocity_variance, wind_speed, BLH, cloud_base_height) for your analyses. Use the quality flags (BLH_flag, cloud_flag) to filter out poor-quality retrievals. For more information or questions about processing methods, please contact:Nicholas E. Prince ⟨nec5299@psu.edu⟩Penn State Department of Meteorology & Atmospheric Science

Air Quality

Data for Selected Ion Monitoring for Orbitrap-Based Metabolomics

Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage.f

Mass Spectrometry

Electron Ion Collider Strong Hadron Cooling design Summary

The Electron-Ion Collider (EIC) requires a high-energy cooler to maintain excellent beam quality and achieve high luminosity throughout long collision stores. To meet this requirement, the EIC project has adopted a novel approach known as Coherent Electron Cooling (CeC)—referred to as Strong Hadron Cooling (SHC)—which can provide rapid cooling rates at high energies. The SHC relies on an Energy Recovery Linac (ERL) to provide the intense, high-quality, and low-noise electron beam essential for the cooling process. This paper summarizes the design progress of the Strong Hadron Cooler for the EIC. We discuss key aspects of the project, including cooling physics modeling, luminosity evolution during collisions, the ERL design, risk mitigation strategies, remaining challenges, and ongoing R&D efforts.

43 PARTICLE ACCELERATORS

Multi-Dimensional Spectroscopy with Intense Entangled Beams: Entanglement-Enabled Phase Matching in a Collinear Beam Geometry

The experimental realization of quantum molecular spectroscopy with entangled photons remains challenging owing to the low signal-to-noise ratio resulting from the use of low-flux entangled photons. High-flux entangled photons via intense entangled beams can be used to improve the signal-to-noise ratio, but the presence of unentangled photons contaminates the quantum signal stemming from entangled photons. Here, we demonstrate how intense entangled beams can be used in multi-dimensional spectroscopy while retaining the advantage of photon entanglement. Our approach is broadly applicable to odd-ordered nonlinear spectroscopies, and it generates purely quantum spectroscopic signals. The proposed approach allows the recording of desired phase-matched signals even in a collinear beam geometry, which lifts the requirement of complicated beam geometry setups for phase matching in multi-dimensional spectroscopies.

Absorption spectroscopy

Assessing Membership Inference Attacks under Distribution Shifts

Membership inference attacks (MIAs) exploit machine learning models to infer whether a data point was in the training set, posing significant privacy risks even with limited black-box access. These attacks rely on the attacker approximating the target model’s training distribution, yet the impact of distribution shifts between target and shadow models on MIA success remains underexplored. We systematically evaluate five types of distribution shifts —-cutout, jitter, Gaussian noise, label shift, and attribute shift —- at varying intensities. Our results reveal that these shifts affect MIA effectiveness in nuanced ways, with some reducing attack success while others exacerbate vulnerabilities, and the same shift can have opposite effects depending on the type of MIA. This highlights the complex interplay between distributional differences and attack performance, offering critical insights for improving model defenses against MIAs.

Shi, Yichuan [Massachusetts Institute of Technolog