Case Study: NREL Campus Chilled Water Storage Potential: Benchmark Datasets Development and Applications, Task 4 - Use Case Demonstration

The Benchmark Datasets Development and Applications project is a three-year collaboration between the National Renewable Energy Laboratory (NREL), Oak Ridge National Laboratory, Pacific Northwest National Laboratory, and Lawrence Berkeley National Laboratory. The project seeks to collect and curate high-resolution, well-calibrated time series of building operational and indoor/outdoor environmental data, which are crucial to understanding and optimizing building energy efficiency performance and demand flexibility capabilities as well as benchmarking energy algorithms. Project outcomes include approximately twelve high-fidelity building datasets, enhanced data representation tools, and four case studies to illustrate example applications. The goal of these case studies is to define and execute analyses that demonstrate how one or more datasets collected through this project can address a data gap or challenge historically faced by building stakeholders. This technical paper summarizes the findings of one of these case studies, in which we studied the operational efficiencies of the central cooling system at NREL. We looked at three years of data from the three chillers in the Field Test Laboratory Building (FTLB), from 2019 to 2021, to compare equipment operation and demand throughout the time period. Our analysis indicates that all three chillers are operating at or below the optimal loading conditions for most of the operation time, and thus there was no efficiency drop due to loading of the chillers at full capacity. Our recommendation is that no chiller capacity increase is needed; instead, the central plant could benefit from adopting advanced control logics for optimal sequencing of chillers during part load operations. Analysis of adding chilled water thermal storage to the central plant indicated 34% savings in demand cost and 24.5% savings in total cost (energy consumption and demand charge cost). The payback period is estimated to be 11-22 years with an assumed TES cost of $\$$100-$200 per ton. This case study shows how a selected dataset is used to solve a practical building problem - learning the operational status of its components, analyzing the effectiveness of a proposed new technique, and aiding decision-making for the building operations and maintenance team.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Management Information System Powers NREL's Intelligent Campus

NREL's Intelligent Campus program leverages its own laboratory buildings as research instruments to study renewable energy, energy efficiency, and energy storage, integration, and analysis with real, quantitative measurements. At the heart of NREL's Intelligent Campus program is its Energy Management Information System (EMIS), a family of tools and services used to manage building and campus energy use. NREL's EMIS includes capabilities, such as benchmarking and monthly utility tracking, interval meter analytics, equipment fault detection and diagnostics, condition-based monitoring, and supervisory control, enabling unprecedented energy management capabilities. The system serves as a demonstration project for other federal facilities interested in learning about its design, features, and benefits.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Energy Management Information System Powers NREL's Intelligent Campus

NREL's Intelligent Campus program leverages its own laboratory buildings as research instruments to study renewable energy, energy efficiency, and energy storage, integration, and analysis with real, quantitative measurements. At the heart of NREL's Intelligent Campus program is its Energy Management Information System (EMIS), a family of tools and services used to manage building and campus energy use. NREL's EMIS includes capabilities, such as benchmarking and monthly utility tracking, interval meter analytics, equipment fault detection and diagnostics, condition-based monitoring, and supervisory control, enabling unprecedented energy management capabilities. The system serves as a demonstration project for other federal facilities interested in learning about its design, features, and benefits.

EMIS↗

Unlocking America's Abundant Marine Energy Resources

NREL Marine Energy One-Pager: A resource designed for use during NREL campus visits - especially with high-profile guests - as well as at events in Washington, D.C., when engaging with the new administration, and for displays at WPTO or lab booths. The U.S. holds vast untapped marine energy resources - wave, tidal, river, and ocean currents - that can strengthen grid resilience, support coastal communities, and advance energy independence. NREL leads innovation in this space through advanced modeling tools, patented technologies, and world-class testing facilities. NREL's simulation platforms, like OpenFAST and SAM, help reduce development time and risk. Patented devices such as PKelp and FlexWEC demonstrate flexible, resilient approaches to energy capture. At Flatirons Campus, NREL offers motion simulation, structural testing, wave tanks, and megawatt-scale microgrid emulation via the ARIES platform. These capabilities help developers refine and validate devices before in-water trials. With upcoming open-water testing at PacWave and strong partnerships, NREL is accelerating the path to commercialization - positioning the U.S. as a global leader in marine energy innovation.

17 WIND ENERGY↗

Real-Time Implementation of Smart Wireless Charging of On-Demand Shuttle Service for Demand Charge Mitigation

This paper presents a smart charge management strategy for an on-demand electric shuttle operating at the National Renewable Energy Laboratory (NREL) campus and supported by an inductive charger at the vehicle's waiting spot. A new control algorithm has been proposed for mitigating the demand charges incurred from the wireless charger. It monitors the shuttle, wireless charger, renewable energy generation, and other loads and regulates charging behavior for demand charge mitigation. Within the control algorithm, an energy prediction is made to estimate the mobility needs of the vehicle and maintain uninterrupted service during operation while still minimizing peak demand. The proposed controller is designed and optimized using a Simulink model for the entire system. It is then implemented and tested in real time at the NREL campus using online cloud services. Two vehicle-use cases' charge-sustaining and charge-depletion operation' are tested under different campus power profiles and drive cycles to assess the controller's performance. In this work, the proposed controller showed a robust performance under different driving scenarios, with high correlation between simulation and experimental data. The results show that proper demand response can be achieved, with an average of 94% reduction of charging loads during peak demand events.

33 ADVANCED PROPULSION SYSTEMS↗

Charge Management for an Inductively Charged On-Demand Battery-Electric Shuttle Service with High Penetration of Renewable Energy

This paper presents a charge management control strategy for an on-demand battery-electric shuttle van operating at the National Renewable Energy Laboratory (NREL) campus and supported by day-time inductive charging at the vehicle's waiting spot. A new control algorithm has been proposed for reducing the demand charge costs incurred from wireless charging of the on-demand shuttle. A custom controller has been developed to monitor the shuttle, wireless charger, renewable energy generation, and various loads at NREL's campus, and regulate charging behavior for demand response. The intermittent renewable generation and sporadic operation of the on-demand shuttle service contribute to a high level of uncertainty in expected campus load profile, which must be carefully managed. The control algorithm predicts energy profile to estimate the mobility needs of the vehicle and maintain uninterrupted service during operation while still minimizing peak demand. The proposed controller has been designed and optimized using a Simulink model for the entire system. Next, it has been implemented and tested in real-time on the NREL campus. Two primary vehicle-use cases, charge sustaining and charge depletion operation, are tested under different load profiles and drive cycles to assess the controller's effectiveness at reducing peak demand and therefore demand charges. The proposed controller showed robust performance under different driving scenarios with high correlation between simulated and experimental data. The results showed that proper demand response can be achieved with an average of 94% reduction of charging loads during peak demand events.

ADVANCED PROPULSION SYSTEMS,ENERGY STORAGE↗

Creating an Energy Intelligent Campus: Data Integration Challenges and Solutions at a Large Research Campus

Rich, well-organized building performance and energy consumption data enable a host of analytic capabilities for building owners and operators, from basic energy benchmarking to detailed fault detection and system optimization. Unfortunately, data integration for building control systems is challenging and costly in any setting. Large portfolios of buildings--campuses, cities, and corporate portfolios--experience these integration challenges most acutely. These large portfolios often have a wide array of control systems, including multiple vendors and nonstandard communication protocols. They typically have complex information technology (IT) networks and cybersecurity requirements and may integrate distributed energy resources into their infrastructure. Although the challenges are significant, the integration of control system data has the potential to provide proportionally greater value for these organizations through portfolio-scale analytics, comprehensive demand management, and asset performance visibility. As a large research campus, the National Renewable Energy Laboratory (NREL) experiences significant data integration challenges. To meet them, NREL has developed an architecture for effective data collection, integration, and analysis, providing a comprehensive view of data integration based on functional layers. The architecture is being evaluated on the NREL campus through deployment of three pilot implementations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Glimpse of the Solar Eclipse from NREL

On August 21, the NREL campus in Golden, Colorado experience a near-complete eclipse of the sun. This video, recorded from NREL’s Solar Radiation Research Laboratory, where researchers carefully measure the sun’s energy, captures the moon crossing the sun before clouds move in and cover the sun.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermosyphon Cooler Hybrid System for Water Savings in an Energy-Efficient HPC Data Center: Modeling and Installation: Preprint

The Thermosyphon Cooler Hybrid System (TCHS) integrates the control of a dry heat rejection device, the thermosyphon cooler (TSC), with an open cooling tower. A combination of equipment and controls, this new heat rejection system embraces the 'smart use of water,' using evaporative cooling when it is most advantageous and then saving water and modulating toward increased dry sensible cooling as system operations and ambient weather conditions permit. Innovative fan control strategies ensure the most economical balance between water savings and parasitic fan energy. The unique low-pressure-drop design of the TSC allows water to be cooled directly by the TSC evaporator without risk of bursting tubes in subfreezing ambient conditions. Johnson Controls partnered with the National Renewable Energy Laboratory (NREL) and Sandia National Laboratories to deploy the TSC as a test bed at NREL's high-performance computing (HPC) data center in the first half of 2016. Located in NREL's Energy Systems Integration Facility (ESIF), this HPC data center has achieved an annualized average power usage effectiveness rating of 1.06 or better since 2012. Warm-water liquid cooling is used to capture heat generated by computer systems direct to water; that waste heat is either reused as the primary heat source in the ESIF building or rejected using evaporative cooling. This data center is the single largest source of water and power demand on the NREL campus, using about 7,600 m3 (2.0 million gal) of water during the past year with an hourly average IT load of nearly 1 MW (3.4 million Btu/h) -- so dramatically reducing water use while continuing efficient data center operations is of significant interest. Because Sandia's climate is similar to NREL's, this new heat rejection system being deployed at NREL has gained interest at Sandia. Sandia's data centers utilize an hourly average of 8.5 MW (29 million Btu/h) and are also one of the largest consumers of water on Sandia's site. In addition to describing the installation of the TSC and its integration into the ESIF, this paper focuses on the full heat rejection system simulation program used for hourly analysis of the energy and water consumption of the complete system under varying operating scenarios. A follow-up paper will detail the test results. The evaluation of the TSC's performance at NREL will also determine a path forward at Sandia for possible deployment in a large-scale system not only for data center use but also possibly site wide.

97 MATHEMATICS AND COMPUTING↗

Parked aeroelastic field rotor response for a 20% scaled demonstrator of a 13‐MW downwind turbine

Abstract Aeroelastic parked testing of a unique downwind two‐bladed subscale rotor was completed to characterize the response of an extreme‐scale 13‐MW turbine in high‐wind parked conditions. A 20% geometric scaling was used resulting in scaled 20‐m‐long blades, whose structural and stiffness properties were designed using aeroelastic scaling to replicate the nondimensional structural aeroelastic deflections and dynamics that would occur for a lightweight, downwind 13‐MW rotor. The subscale rotor was mounted and field tested on the two‐bladed Controls Advanced Research Turbine (CART2) at the National Renewable Energy Laboratory's Flatiron Campus (NREL FC). The parked testing of these highly flexible blades included both pitch‐to‐run and pitch‐to‐feather configurations with the blades in the horizontal braked orientation. The collected experimental data includes the unsteady flapwise root bending moments and tip deflections as a function of inflow wind conditions. The bending moments are based on strain gauges located in the root section, whereas the tip deflections are captured by a video camera on the hub of the turbine pointed toward the tip of the blade. The experimental results are compared against computational predictions generated by FAST, a wind turbine simulation software, for the subscale and full‐scale models with consistent unsteady wind fields. FAST reasonably predicted the bending moments and deflections of the experimental data in terms of both the mean and standard deviations. These results demonstrate the efficacy of the first such aeroelastically scaled turbine test and demonstrate that a highly flexible lightweight downwind coned rotor can be designed to withstand extreme loads in parked conditions.

17 WIND ENERGY↗

Unified architecture for data-driven metadata tagging of building automation systems

This article presents a Unified Architecture (UA) for automated point tagging of Building Automation System (BAS) data, based on a combination of data-driven approaches. Advanced energy analytics applications—including fault detection and diagnostics and supervisory control—have emerged as a significant opportunity for improving the performance of our built environment. Effective application of these analytics depends on harnessing structured data from the various building control and monitoring systems, but typical BAS implementations do not employ any standardized metadata schema. While standards such as Project Haystack and Brick Schema have been developed to address this issue, the process of structuring the data, i.e., tagging the points to apply a standard metadata schema, has, to date, been a manual process. This process is typically costly, labor-intensive, and error-prone. In this work we address this gap by proposing a UA that automates the process of point tagging by leveraging the data accessible through connection to the BAS, including time-series data and the raw point names. The UA intertwines supervised classification and unsupervised clustering techniques from machine learning and leverages both their deterministic and probabilistic outputs to inform the point tagging process. Furthermore, we extend the UA to embed additional input and output data-processing modules that are designed to address the challenges associated with the real-time deployment of this automation solution. We test the UA on two datasets for real-life buildings: (i) commercial retail buildings and (ii) office buildings from the National Renewable Energy Laboratory (NREL) campus. We report the proposed methodology correctly applied 85–90% and 70–75% of the tags in each of these test scenarios, respectively for two significantly different building types used for testing UA's fully-functional prototype. The proposed UA, therefore, offers promising approach for automatically tagging BAS data as it reaches close to 90% accuracy. Further building upon this framework to algorithmically identify the equipment type and their relationships is an apt future research direction to pursue.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Testing and Assessment of EMFs and Touch Currents from 25-kW IPT System for Medium-Duty EVs

Inductive power transfer (IPT) technology has gained massive attention for electric vehicle charging due to the associated reliability, convenience, and safety. Nevertheless, the loose coupling between the transmitter and receiver generates intensive electromagnetic fields (EMFs) around the system, which may influence living objects' safety if the typical limits are exceeded. Moreover, these fields induce voltages in the vehicle body, which may lead to touch current passing through the human body when it gets in contact with two metal parts or one part and the ground. Following the international standards and recommendations, this study presents comprehensive test guidelines for the near-EMFs and touch currents from a commercial 25-kW wireless charger from Momentum Dynamics, which was installed in an electric shuttle operating at the National Renewable Energy Laboratory (NREL) campus. The paper investigates the measuring devices, test setup, test points and standard limits. The impact of the misalignments on the measurements is considered during testing. EMFs are measured in areas around and inside the shuttle and near the power supply and compared with the reference levels defined by the international standards, including ICNIRP 2010, IEEE C95.1 and ACGIH TLV 2017. Touch currents are evaluated among different metal parts and ground in comparison with the standard limits. The results show that both EMFs and touch currents comply with the standard limits. Moreover, thermal inspection for the system after installation was provided. Finally, a 5-day of operation data for the wireless charger are collected and presented.

33 ADVANCED PROPULSION SYSTEMS↗

Ibis Networks/WattIQ (IN2 Final Report)

Ibis Networks is a full-stack cleantech company that provides plug-level energy monitoring and control to solve energy and asset management problems for the enterprise. During DATES – DATES, an NREL research team worked with the Ibis team to validate their product, the InteliSocket. The Ibis InteliSocket is a pass-through plug-load energy monitor and controller that is designed to reduce energy wasted by common 120 V plug-in devices in commercial office buildings, such as computer peripherals, conference room AV equipment, and break-room appliances. The system can shut off supply power to these end uses via remote control, manual switches, pre-set schedules, or automated control algorithms. The scope of this IN2 project was the development and refinement of “smart” learning behavior algorithms (LBAs), which could help installation processes and dramatically expand the sockets’ capabilities and energy-saving potential by suggesting suitable control schedules that are based on monitored use patterns. While Ibis has the analytical and software expertise for algorithm development, the lack of test data, both in a controlled laboratory setting and in real-life deployment scenarios, represented a key barrier toward commercialization of the product. Assistance through the IN2 program provided an opportunity to conduct the needed “trial and error” algorithm development. The project included baseline field-data collection, laboratory testing, and field validation components, all of which were conducted at the NREL campus between April 2017 and July 2019.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Machine Learning for Automated Metadata Assignment in Buildings: Cooperative Research and Development (Final Report, CRADA Number CRD-18-00767)

RealTerm Energy and NREL have identified a shared vision to evaluate opportunities to facilitate the organization and assignment of metadata to building control system (BCS) data via industry-informed machine learning (ML). Manual metadata assignment is labor intensive and costly, slowing down any Energy Management and Information System (EMIS) deployment in the building space. This project aims to develop methodologies to accurately assign this metadata and significantly decrease the level of effort associated with deploying EMIS. The objective of this project is to identify/design methodologies to assign metadata to HVAC control points automatically. The identified methodologies will be programmed in analytics algorithms so they can ingest a list of points and produce a detailed tagging following the Haystack classification nomenclature. To validate the efficacy of each methodology, tagging results will be compared utilizing a list of points extracted from RealTerm's building database-as well as data extracted from the NREL campus via the Intelligent Campus program-enabling testing against large datasets with real world challenges. The developed methodologies may leverage building manager/operator input on a limited basis to add context to the classifying algorithms. The partnership aims to advance global efforts in areas related to the DOE missions through improving operational performance of commercial buildings. It is well documented that buildings fall out of commission after they are occupied, wasting significant energy and incurring associated costs simply due to poor operational performance. Emerging EMIS technologies that perform continuous commissioning help to address this issue, yet integration of these systems can be labor intensive both for the technology vendor and the building owner/operator. This project will enable more efficient and cost-effective analytics for buildings, enabling improvement in building operations at lower cost points.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Advanced Distributed Wind Turbine Controls Series: Part 4-Wind Energy in Microgrids – Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

In recent years, the technical capabilities and requirements for distributed wind turbines to provide ancillary services beyond maximum energy production has increased. Ancillary services, leveraged through advanced wind turbine controls, can support grid stability, reliability, and resilience. In the context of a microgrid, wind turbines can provide ancillary services that are useful in both islanded and grid-connected modes, as demonstrated in previous parts of this report series. This report focuses on how wind turbines with advanced controls and power electronics can support the stability of the microgrid during transitions from grid-connected to island mode, and back. This report documents simulation results from a model of the National Renewable Energy Laboratory (NREL) Flatirons Campus containing NREL's 600-kilowatt Controls Advanced Research Turbine. Using this turbine, we demonstrate through desktop simulation how a wind turbine can support the voltage and frequency of a microgrid during transitions - from making planned transitions seamless to keeping all loads online during some unplanned transitions to supporting black start in the event of an open transition (blackout).

17 WIND ENERGY↗

NREL, Industry Collaboration to Usher in New Wave of Autonomous Vehicle Research

In an important step toward advancing intelligent, efficient, and autonomous electric vehicles, the National Renewable Energy Laboratory (NREL) plans to partner on research and development efforts with EasyMile, a smart mobility solutions company. EasyMile provided a demo of its driverless EZ10 shuttle on the NREL campus in September 2017.

33 ADVANCED PROPULSION SYSTEMS↗