Search NASA⌕ Search

SEARCH · Search NASA

Results for “NTF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Modification of conventional peak shapes to accurately represent spectral asymmetry: High-Resolution X-ray photoelectron spectra of [C 4 C 1 Pyrr][NTf 2 ] and [C 8 C 1 Im][NTf 2 ] ionic liquids

X-ray photoelectron spectroscopy (XPS) is one of the most widely used techniques for surface characterization. Analysis of XPS data is challenging and requires the analyst to fit the data with synthetic line shapes to reach physically meaningful interpretations. Experimental spectral envelopes, however, are complex and display asymmetric features that are often ignored or attributed to additional chemical components. The high-resolution XPS spectra of [C 4 C 1 Pyrr][NTf 2 ] and [C 8 C 1 Im][NTf 2 ] all exhibit a degree of asymmetry which is systematically observed at the higher binding energy side of photoemission envelopes. Here, we present the development of a refined fitting procedure for XPS spectra of these ionic liquid-based systems which include (a) Shirley background offset necessary to account for the insulator-like region and (b) spectral asymmetry in C 1s and N 1s regions. Further, Shirley and trapezoid components are applied to compensate for inelastic scattering taking place during electron transitions as high as 7.8 eV above the start of the fitting region in C 1s high-resolution spectrum. To demonstrate the fitness of this model, we present an analysis of a 2:1 mixture of [C 4 C 1 Pyrr][NTf 2 ]: [C 8 C 1 Im][NTf 2 ].

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Increasing Efficiency at the NTF by Optimizing Model AoA Positioning

The National Transonic Facility (NTF) at NASA Langley Research Center (LaRC) is a national resource for aeronautical research and development. The government, military and private industries rely on the capability of this facility for realistic flight data. Reducing the operation costs and keeping the NTF affordable is essential for aeronautics research. The NTF is undertaking an effort to reduce the time between data points during a pitch polar. This reduction is being driven by the operating costs of a cryogenic facility. If the time per data point can be reduced, a substantial cost savings can be realized from a reduction in liquid nitrogen (LN2) consumption. It is known that angle-of-attack (AoA) positioning is the longest lead-time item between points. In January 2005 a test was conducted at the NTF to determine the cause of the long lead-time so that an effort could be made to improve efficiency. The AoA signal at the NTF originates from onboard instrumentation then travels through a number of different systems including the signal conditioner, digital voltmeter, and the data system where the AoA angle is calculated. It is then fed into a closed loop control system that sets the model position. Each process along this path adds to the time per data point affecting the efficiency of the data taking process. Due to the nature of the closed loop feed back AoA control and the signal path, it takes approximately 18 seconds to take one pitch pause point with a typical AoA increment. Options are being investigated to reduce the time delay between points by modifying the signal path. These options include: reduced signal filtering, using analog channels instead of a digital volt meter (DVM), re-routing the signal directly to the AoA control computer and implementing new control algorithms. Each of these has potential to reduce the positioning time and together the savings could be significant. These timesaving efforts are essential but must be weighed against possible loss of data quality. For example, a reduction in filtering can introduce noise into the signal and using analog channels could result in some loss of accuracy. Data quality assessments need to be performed concurrently with timesaving techniques since data quality parameters are essential in maintaining facility integrity. This paper will highlight time saving efforts being undertaken or studied at the NTF. It will outline the instrumentation and computer systems involved in setting of the model pitch attitude then suggest changes to the process and discuss how these system changes would effect the time between data points. It also discusses the issue of data quality and how the potential efficiency changes in the system could affect it. Lastly, it will discuss the possibility of using an open loop control system and give some pros and cons of this method.

Crawford, Bradley L.↗

Development of the NTF-117S Semi-Span Balance

A new high-capacity semi-span force and moment balance has recently been developed for use at the National Transonic Facility at the NASA Langley Research Center. This new semi-span balance provides the NTF a new measurement capability that will support testing of semi-span test models at transonic high-lift testing regimes. Future testing utilizing this new balance capability will include active circulation control and propulsion simulation testing of semi-span transonic wing models. The NTF has recently implemented a new highpressure air delivery station that will provide both high and low mass flow pressure lines that are routed out to the semi-span models via a set high/low pressure bellows that are indirectly linked to the metric end of the NTF-117S balance. A new check-load stand is currently being developed to provide the NTF with an in-house capability that will allow for performing check-loads on the NTF-117S balance in order to determine the pressure tare affects on the overall performance of the balance. An experimental design is being developed that will allow for experimentally assessing the static pressure tare affects on the balance performance.

Lynn, Keith C.↗

Weight, center of gravity and modal test report for NTF fan blade set no. 3

A complete set of fan blades for the National Transonic Facility (NTF) at the NASA Langley Research Center was recently fabricated by Dynamic Engineering Inc. (DEI). These blades were the third complete set of blades fabricated by the NTF. The first set of blades was fabricated by NASA and installed in the tunnel in December 1981. This original set was destroyed in a mishap in January 1989. The second set of blades is currently in use in the NTF. The third set of blades recently fabricated by DEI is a spare set. In order to ensure that the blades met the requirements, DEI performed a series of tests on each of the completed blades. In addition, a model survey was conducted on each blade to define the dynamic characteristics. Discussed here are the blade tests conducted by DEI and the test results. The test set-ups and procedures are discussed in detail. The results obtained for each of the 27 blades are documented and comparisons are made between this set of blades and similar data for two previous sets of NTF fan blades.

Friedman, Inger P.↗

NTF and the Department of Defense

The relationship of the National Transonic Facility (NTF) to the Department of Defense (DOD) is discussed. Recognition of the need for the NTF capabilities were first encountered in military aircraft development. Several tactical aircrafts experienced the after body drag which was higher than predicted by small scale tests, resulting in less than desired transonic acceleration performance. It is necessary to understand the problem because flight efficiency is more important for military aircrafts. Improved cruise performance is required for the whole range of military mission. Factors that make cruise efficiency important include: (1) rapid deployment airlift capability; (2) self-deployment capability for tactical aircraft; (3) reduced tanker dependence for strategic aircraft. It is concluded that the continuing escalating cost of fuel mandates to develop aircraft that are as fuel efficient as possible. Other uses for NTF are outlined.

Siewert, R. F.↗

Surface flow visualization requirements for testing in NTF

Surface flow visualization is required to be correlated at all the facilities to allow the following: (1) an understanding of the chordwise and spanwise extent of laminar flow; (2) the change in shock location for various trip configurations; (3) the effectiveness of the chosen boundary layer trip (since its specifications will change as a function of Reynolds number); and (4) a comparison of the separation patterns at the buffet conditions. A requirement to tunnel-to-tunnel correlation testing involving the NTF is pointed out. A specification for a surface flow visualization system to be used in the NTF is defined. Recognition of the special limitations in the NTF including physical and visual accessibility, high operating cost, flow contamination requirements, as well as the need for on-line review of the results to develop the final trip configurations in a timely manner, leads to the listed requirements.

Bengelink, R. L.↗

Boundary Layer Transition in the NTF: HSR Experience and Plans

Efforts towards understanding boundary layer transition characteristics on a High Speed Civil Transport (HSCT)-class configuration in the National Transonic Facility (NTF) are ongoing. The majority of the High Speed Research (HSR) data base in the NTF has free transition on the wing, even at low Reynolds numbers (Rn) attainable in conventional facilities. Limited data has been obtained and is described herein showing the effects of a conventional, Braslow method based wing boundary-layer trip on drag. Comparisons are made using force data polars and surface flow visualization at selected angles-of-attack and Mach number. Minimum drag data obtained in this study suggest that boundary layer transition occurred very near the wing leading edge by a chord Rn of 30 million. Sublimating chemicals were used in the air mode of operation only at low Rn and low angles-of-attack with no flap deflections; sublimation results suggest that the forebody and outboard wing panel are the only regions with significant laminar flow. The process and issues related to the sublimating chemical technique as applied in the NTF are discussed. Beyond the existing experience, status of efforts to develop a production transition detection system applicable to both air and cryogenic nitrogen environments is presented.

Owens, Lewis R., Jr.↗

Review of Skin Friction Measurements Including Recent High-Reynolds Number Results from NASA Langley NTF

This paper reviews flat plate skin friction data from early correlations of drag on plates in water to measurements in the cryogenic environment of The NASA Langley National Transonic Facility (NTF) in late 1996. The flat plate (zero pressure gradient with negligible surface curvature) incompressible skin friction at high Reynolds numbers is emphasized in this paper, due to its importance in assessing the accuracy of measurements, and as being important to the aerodynamics of large scale vehicles. A correlation of zero pressure gradient skin friction data minimizing extraneous effects between tests is often used as the first step in the calculation of skin friction in complex flows. Early data compiled by Schoenherr for a range of momentum thickness Reynolds numbers, R(sub Theta) from 860 to 370,000 contained large scatter, but has proved surprisingly accurate in its correlated form. Subsequent measurements in wind tunnels under more carefully controlled conditions have provided inputs to this database, usually to a maximum R(sub Theta) of about 40,000. Data on a large axisymmetric model in the NASA Langley National Transonic Facility extends the upper limit in incompressible R(sub Theta) to 619,800 using the van Driest transformation. Previous data, test techniques, and error sources ar discussed, and the NTF data will be discussed in detail. The NTF Preston tube and Clauser inferred data accuracy is estimated to be within -2 percent of a power-law curve fit, and falls above the Spalding theory by 1 percent at R(sub Theta) of about 600,000.

Watson, Ralph D.↗

Progress in Flaps Down Flight Reynolds Number Testing Techniques at the NTF

A series of NASA/Boeing cooperative low speed wind tunnel tests was conducted in the National Transonic Facility (NTF) between 2003 and 2004 using a semi-span high lift model representative of the 777-200 aircraft. The objective of this work was to develop the capability to acquire high quality, low speed (flaps down) wind tunnel data at up to flight Reynolds numbers in a facility originally optimized for high speed full span models. In the course of testing, a number of facility and procedural improvements were identified and implemented. The impact of these improvements on key testing metrics data quality, productivity, and so forth - was significant, and is discussed here, together with the relevance of these metrics as applied to cryogenic wind tunnel testing in general. Details of the improvements at the NTF are discussed in AIAA-2006-0508 (Recent Improvements in Semi-span Testing at the National Transonic Facility). The development work at the NTF culminated with validation testing of a 787-8 semi-span model at full flight Reynolds number in the first quarter of 2006.

Payne, Frank↗

Steady-state RANS Pretest CFD Comparisons for the SWiFT NTF Test

The NATO AVT-298 research program has been underway for seven years to improve the understanding of the full-scale aerodynamics for moderately-swept hybrid wing-bodies found on future civil and military configurations and how this differs from what is measured with low Reynolds number wind tunnel testing or predicted with Computational Fluid Dynamics (CFD). Toward this effort, a hybrid wing-body configuration, known as Swept Wing Flow Test (SWiFT), was designed and tested in the Aircraft Research Association (ARA) and NASA Langley National Transonic Facility (NTF) wind tunnels. This presentation summarizes comparisons between the NTF wind tunnel data and a series of pretest CFD computations generated using steady-state Reynolds-averaged Navier-Stokes (RANS) simulations from participants representing seven institutions using nine separate flow solvers. The objective of this research was to assess the effectiveness of state-of-practice CFD methods in predicting the aerodynamics of swept wing aircraft and identify recommended areas of improvement to the methods themselves. Computational force and moment data will be presented for a series of angle-of-attack and sideslip angle sweeps over a range of Reynolds numbers at both low-speed and near-cruise Mach numbers, as tested in the NTF experiment.

National Transonic Facility↗

Slotted test section dynamics of the NTF

A dynamic model of the National Transonic Facility (NTF) section and plenum chamber was developed. The model serves as a means for determining the dynamic performance of the NTF and the subsequent design of optimal control configurations, and is of one dimensional flow type as to facilitate computer simulation. The model allows for the simulation of the effects of test section blockage, boundary layer losses, slot flow required for supersonic flow generation, reentry flap position, and auxiliary plenum suction.

Gumas, G.↗

NTF management considerations

The National Transonic Facility (NTF) was designed to be a national testing facility satisfying the research and development needs of NASA, DOD, industry, and universities. The NTF offers simulation of full scale Reynolds numbers in the critical flight regions of most current and planned aerospace vehicles. The degree of interest by users will depend greatly upon tunnel productivity, data quality, and cost.

Bower, R. E.↗

Comments on Reynolds number effects and the role of NTF in the development of air vehicles

The National Transonic Facility (NTF) capability to match the full scale Reynolds numbers of all but the largest airplanes is discussed. Conversion factors to enable calculation of Sl-unit equivalents for all U.S. units are listed. Using data from several facilities, analytic methods, and flight test data, a competetive aircraft in the relatively low Reynolds number was developed. The NTF offers the capability to obtain data at full scale Reynolds numbers in the cruise condition for most of the products, and will be much closer than previous tunnels to full scale Reynolds number for the operating envelopes. It is primarily on the operating envelope that Reynolds number effects are most important and least predictable.

Nagel, A. L.↗

The need for an optical transition detection system in the NTF

Methods for transition detection were studied. The very high test and model costs necessitate testing of any new configuration over a range of Reynolds numbers for correlation with data obtained in conventional tunnels. The Reynolds number variations will be carried out at constant dynamic pressure, i.e., constant aeroelastic condition, by varying test temperature. Boundary layer transition cannot be expected to occur at the full scale location at significantly less than full-scale Reynolds numbers, and transition patterns will change with varying Reynolds number. Knowledge of the location of transition on model surfaces is essential for correct interpretation of drag data. The importance of transition, the limitations of artificial transition fixing, and their relation to the NTF are reviewed. The calculated minimum roughness height to instantaneously trip transition on a model transport wing over a range of Reynolds numbers of interest is shown in the NTF.

Fancher, M. F.↗

Design study of advanced model support systems for the National Transonic Facility (NTF)

It has long been recognized that the sting (or support system) is a very critical part of the model system. The designer is frequently faced with the tradeoff of minimizing sting size, thereby compromising facility and model safety, against a larger sting and the subsequent problems of sting interference effects. In the NASA Langley Research Center National Transonic Facility (NTF), this problem is accentuated by the severe environment of high pressure/low temperature, designed into the facility to provide the desired high Reynolds number. Compromises in the configuration geometry and/or limiting the test envelope are therefore contrary to the purposes and goals of the NTF and are unacceptable. The results of an investigation aimed at improvements of 25% in both strength and Young's modulus of elasticity as compared to high strength cryogenically acceptable steels currently being used are presented. Various materials or combinations of materials were studied along with different design approaches. Design concepts were developed which included conventional material stings, advanced composites, and hybrid configurations. Candidate configurations are recommended.

Source record↗

Testing experience with unheated stain-gage balances in the NTF

A series of cryogenic (cryo) cycles was conducted in the cryo chamber at the National Transonic Facility (NTF) in order to identify the cause of apparent strain shifts in axial force with temperature for the Pathfinder I model and to minimize their effects. The results of the investigation indicated that the major cause of axial force end point shifts and thermal hysteresis loops was the thickness of the Teflon insulation on the instrumentation wires crossing the balance. By reducing the thickness of the insulation and the total number and size of the wires, apparent strain values were achieved for the model with instrumentation wires which were nearly identical to those for the model without wires. Because of the special design features used, the balance output was very accurate and repeatable over the entire NTF temperature range, even with balance thermal gradients as large as 64 F and transient conditions as large as 3 F/minute.

Jacobs, Peter F.↗

The National Transonic Facility (NTF) Operational Status

The National Transonic Facility (NTF) is a fully operational, productive and efficient cryogenic wind tunnel currently supporting the Nation's aircraft industry needs providing flight Reynolds number research data for focused development programs as well as investigating the Reynolds number scaling phenomenon. The following presentation is a collection of viewgraphs and notes prepared from previous talks. This material is intended to provide a 'general overview' of The National Transonic Facility (NTF) Operational Status as outlined in the following Agenda.

Hill, Jeffrey S.↗

Testing the 2.2% HSR Reference H Model with a Modified Wing Planform in the NTF

The HSR program moved into phase two with the selection of a new airplane configuration, the Technology Concept Airplane (TCA). The TCA was designed based on the experiences gained while investigating both the Reference H and the Arrow Wing configurations in different wind tunnels and CFD studies. Part of that investigation included performing extensive high Reynolds number testing on the Reference H configuration in the NTF to provide data for predicting full-scale flight performance, as well as developing techniques for testing these types of configurations in the NTF. With the selection of the TCA configuration, a smaller investigation was designed to examine whether or not the scaling characteristics of the TCA configuration are similar to those observed for the Reference H configuration. This presentation will include a description of the 2.2% Modified Reference H model used in this investigation (highlighting the similarities and the differences when compared to the TCA configuration), the testing objectives, and some preliminary findings that are relevant to the current high-lift system.

Owens, Lewis R., Jr.↗