NUclear Measurement System Optimization

The NUclear Measurement System Optimization (NUMSO) toolbox interfaces with models developed using SGA to provide combined uncertainty and related operations information about the safeguards process. The primary focus of NUMSO is to determine the best locations and operating times for measurement devices to minimize the sum of Type I and Type II errors. A secondary focus is to determine the key contributors to the Type I and Type II errors indicated by SGA. NUMSO can also determine the best devices to recalibrate and the best times to recalibrate those devices given a limited budget.

Johnson, Benjamin↗

Level 2 Milestone MRT 6218: Improve Nuclear Measurements on the NIF

This report documents the completion of the Inertial Confinement Fusion, Level 2 Milestone MRT 6218, “Improve Nuclear Measurements on the NIF.” The three completion criteria are, “1) Complete Operational qualification (OQ) of Pulse Dilation PMT on the Gas Cherenkov Detector in the Well DIM at NIF, 2) Measure highly resolved (temporal magnification >= 5x) gamma signals for Carbon (ablator) history, 3) Measure highly resolved (temporal magnification >= 5x) gamma signals for DT fusion reaction history.”

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Highly charged ion approach to measure nuclear charge radii of Fr, Ra, and Rn isotopes for precision measurements

Conventional electron scattering and muonic atom spectroscopy techniques are challenging to apply to heavy ions unless the element has at least one stable or extremely long-lived isotope. To overcome this limitation, a recently introduced method for determining nuclear charge radii relies on extreme-ultraviolet (EUV) spectroscopy of the D 1 line in highly charged Na-like ions. In this work, we present an experimental approach to measure the nuclear charge radii of isotopes of radioactive elements such as Fr, Ra, and Rn using this method at TRIUMF’s Ion Trap for Atomic and Nuclear Science (TITAN) instrument, located at the ISAC radioactive beam facility. We also explore the potential of using Na-like D 2 lines in the soft x-ray region for future measurements.

Electron beam ion trap↗

Measuring Nuclear Clusters in the Short-Baseline Near Detector

The Short-Baseline Near Detector (SBND) is the first Liquid Argon Time Projection Chamber (LArTPC) with high enough resolution and large enough neutrino flux to measure the cross-section for production of heavier-than-proton fragments in neutrino interactions. SBND is an 112-ton LArTPC, and lies 110 m downstream from the Booster Neutrino Beam target, where it is collecting more than two million neutrino interactions per year. As a result of both the intranuclear cascade and nuclear de-excitation, neutrino interactions with argon can produce nuclear clusters such as deuterons, tritons, helions and alpha particles, which have so far only been seen as vertex activity or mis-reconstructed as protons. With LArTPC technology's excellent reconstruction capabilities and SBND's unprecedented neutrino statistics, a measurement of these nuclear clusters could distinguish between nuclear models and improve neutrino energy reconstruction. This poster presents the status of simulation and reconstruction of nuclear clusters in SBND.

Beever, Anna L. [Unlisted, US] (ORCID:000900069339↗

Inferring thermal ion temperature and residual kinetic energy from nuclear measurements in inertial confinement fusion implosions

In inertial con finement fusion implosion experiments, the presence of residual anisotropic fluid motion within the stagnating hot spot leads to signifi cant variations in ion-temperature measurements using neutron time- of-flight detectors along different lines of sight. The minimum ion-temperature measurement is typically used as representative of the thermal temperature. In the presence of isotropic flows, however, even the minimum DT neutron-inferred ion temperature can be well above the plasma thermal temperature. Using both DD and DT neutron-inferred ion-temperature measurements, we show that it is possible to determine the contribution of isotropic flows and infer the DT burn-averaged thermal ion temperature. The contribution of large isotropic flows on driving the ratio of DD to DT neutron-inferred ion temperatures well below unity and approaching the lower bound of 0.8 is demonstrated in multimode simulations. The minimum DD neutron- inferred ion temperature is determined from the velocity variance analysis, accounting for the presence of isotropic flows. Being close to the DT burn-averaged thermal ion temperature, the inferred DD minimum ion temperatures demonstrate a strong correlation with the experimental yields in the OMEGA implosion database. An analytical expression is also derived to explain the effect of mode ℓ = 1 ion-temperature measurement asymmetry on yield degradations caused by the anisotropic flows.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improving nuclear data evaluations with predictive reaction theory and indirect measurements

Nuclear reaction data required for astrophysics and applications is incomplete, as not all nuclear reactions can be measured or reliably predicted. Neutron-induced reactions involving unstable targets are particularly challenging, but often critical for simulations. In response to this need, indirect approaches, such as the surrogate reaction method, have been developed. Nuclear theory is key to extract reliable cross sections from such indirect measurements. We describe ongoing efforts to expand the theoretical capabilities that enable surrogate reaction measurements. We focus on microscopic predictions for charged-particle inelastic scattering, uncertainty-quantified optical nucleon-nucleus models, and neural-network enhanced parameter inference.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Implications of first neutrino-induced nuclear recoil measurements in direct detection experiments: Probing nonstandard interaction via CE ν NS

PandaX-4T and XENONnT have recently reported the first measurement of nuclear recoils induced by the B 8 solar neutrino flux, through the coherent elastic neutrino-nucleus scattering ( CE ν NS ) channel. As long anticipated, this is an important milestone for dark matter searches as well as for neutrino physics. This measurement means that these detectors have reached exposures such that searches for low mass, ≲ 10 GeV dark matter cannot be analyzed using the background-free paradigm going forward. It also opens a new era for these detectors to be used as neutrino observatories. In this paper we assess the sensitivity of these new measurements to new physics in the neutrino sector. We focus on neutrino nonstandard interactions (NSI) and show that—despite the still moderately low statistical significance of the signals—these data already provide valuable information. We find that limits on NSI from PandaX-4T and XENONnT measurements are comparable to those derived using combined COHERENT CsI and LAr data. Furthermore, they provide sensitivity to pure τ flavor parameters that are not accessible using stopped-pion or reactor sources. With larger exposures and consequently improvements of statistical uncertainties, forthcoming data from these experiments will provide important, novel results for CE ν NS -related physics. Published by the American Physical Society 2025

Sierra, D. Aristizabal↗

Modeling Systematic Discrepancies in Nuclear-Data Measurements with Machine Learning

Nuclear data and their associated co-variances are constantly being reevaluated as techniques improve and as new experimental data, as well as nuclearmodel developments, emerge. A standard technique used to evaluate mean values in nuclear data, and their associated covariances, is the generalized linear least squares (GLLS) method. Aligning with recent efforts to incorporate measurement features into nuclear data evaluation, we augment GLLS by including a linear term which attempts to predict potential systematic discrepancies in experimental data as related to the measurement features. Due to the general nature of this augmentation, we are able to apply this evaluation to three key observables: neutroninduced fission cross sections, the average prompt neutron multiplicity, and the prompt-fission neutron spectrum of ²³⁹Pu.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The status and future of direct nuclear reaction measurements for stellar burning

The study of stellar burning began just over 100 years ago. Nonetheless, we do not yet have a detailed picture of the nucleosynthesis within stars and how nucleosynthesis impacts stellar structure and the remnants of stellar evolution. Achieving this understanding will require precise direct measurements of the nuclear reactions involved. Furthermore, this report summarizes the status of direct measurements for stellar burning, focusing on developments of the last couple of decades, and offering a prospectus of near-future developments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements of Nuclear Effects and the $\bar \nu_\mu +H \to \mu^+ + n$ Cross Section in MINERνA with Neutron Tagging

MINERνA, or Main INjector ExpeRiment for ν-A, at Fermilab, is an experimentdedicated to the study of neutrino-nucleus interactions in the GeV regime. Itsgoal is to illustrate the interplay between hadronic and nuclear physics and measure intranuclear dynamics crucial for the present and future neutrino oscillationmeasurements. We first measure a set of variables sensitive to how Monte Carlo(MC) simulations of neutrino-nucleus interactions implement binding energy andthen move on to measure the antineutrino CCQE cross section on the hydrogentargets in MINERνA’s CH detector. We have developed a method to preferentially select events on the hydrogen by comparing outgoing neutrons’ directions totheoretical neutron directions assuming two-body interactions. We measured thecross section, extracted the axial form factor, and performed a Z-expansion fit. Weobserve larger values in the axial form factor at high Q2than current best fits. Finally, we show a preliminary selection of events with both protons and neutrons toinvestigate nuclear processes responsible for producing these final states.

Cai, Tejin↗

Preparation and characterization of isotopically pure Mo targets for nuclear science measurements

Isotopically pure molybdenum targets are essential in various nuclear science measurements. For studies of cross sections of capture reactions on molybdenum, uniform targets with areal densities of hundreds of g/cm 2 are desired. Mechanical rolling of enriched metal pieces or vacuum sputtering methods used in previous studies to prepare molybdenum targets are challenging and involve labor- and time-intensive processes. Therefore, reliable and straightforward methods to produce molybdenum targets are crucial. We have developed a new double-step method to produce targets meeting these needs. The first step consists of evaporating isotopically enriched MoO 3 onto gold backings. The second step involves the reduction of the oxide layer in a 5% H 2 -Ar environment to obtain molybdenum targets. X-ray fluorescence (XRF) spectroscopy, X-ray Diffraction (XRD), a scanning electron microscope/focused ion beam milling, and energy-dispersive X-ray spectroscopy (EDS) were used to characterize the targets. These methods show that the targets exhibit a uniform coverage of Mo over the gold backings. Furthermore, significant volume shrinkage occurring during the reduction of MoO 3 creates a porous Mo layer where the gold diffuses due to the high processing temperatures, resulting in mixed Mo–Au layers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Historic Nuclear Cloud Measurement for Entrainment Parameter Determination

We evaluated the uncertainties associated with the entrainment parameters computed from nuclear cloud measurements taken during historic weapon testing campaigns. This evaluation found that variations in the way cloud heights and diameters were defined during the analysis of film records result in very large uncertainties in the entrainment parameters, severely limiting the utility of these data. For the measurements of atmospheric conditions at the time of the tests, the main sources of error are associated with the differences in the location and timing of the soundings.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Design and Validation of a Gammaray Scanning System for Measuring Irradiated Nuclear Fuel

A prototype gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. This paper documents the design process, modeling and the laboratory characterization performed to validate the system. The modeling of the system was done using the Monte Carlo N-Particle code with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector. The characterization included measurements of calibrated radiation sources in different geometries, and calculations for absolute efficiency and dead time. Benchmark measurements were performed by scanning an irradiated fuel rodlet containing ten pellets of 4.9% enriched UO2 in zirconium alloy. These results were compared to simulated spectra to further help characterize the detector model. One goal of the system is to determine the number of fissions per gram of UO2 in the fuel; comparison of the results from this prototype system's assay of the irradiated fuel rodlet are in agreement with previously estimated results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗