Search NASA⌕ Search

SEARCH · Search NASA

Results for “NaAs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Influence of NaA Zeolite Crystal Expansion/Contraction on Zeolite Membrane Separations

In-situ powder XRD measurements showed that the NaA zeolite unit cell contracts and expands upon adsorption, and these changes in zeolite crystal size correlate with permeation changes through NaA zeolite membranes. These membranes had high pervaporation selectivities, even though gas permeation was mainly through defects, as indicated by Knudsen selectivities for gases. At 300 K and a thermodynamic activity of 0.03, water contracted the NaA crystals by 0.22 vol%, and this contraction increased the helium flux through two NaA membranes by approximately 80%. Crystal contraction also increased the fluxes of i-butane during vapor permeation and i-propanol (IPA) during pervaporation (~ 0.03 wt% water). At activities above 0.07, water expanded NaA crystals and correspondingly decreased the membrane fluxes of helium, i-butane, and IPA. Similarly, methanol contracted NaA crystals by 0.05 vol% at an activity of 0.02, and this contraction slightly increased the helium and i-butane fluxes through a NaA membrane. Above an activity of 0.06, methanol expanded the crystals, and the fluxes of helium and i-butane through a NaA membrane decreased. The adsorbate-induced changes explain some pervaporation behavior reported by others, and they indicate that crystal expansion and contraction may increase or decrease zeolite NaA membrane selectivity by changing the defect sizes.

10 SYNTHETIC FUELS↗

Stabilization of the Polar Structure and Giant Second-Order Nonlinear Response of Single Crystal γ-NaAs 0.95 Sb 0.05 Se 2

The dearth of suitable materials significantly restricts the practical development of infrared (IR) laser systems with highly efficient and broadband tuning. Recently, γ-NaAsSe 2 is reported, and it exhibits a large nonlinear second-harmonic generation (SHG) coefficient of 590 pm V —1 at 2 µm. However, the crystal growth of γ-NaAsSe 2 is challenging because it undergoes a phase transition to centrosymmetric δ-NaAsSe 2 . Herein, the stabilization of non-centrosymmetric γ-NaAsSe 2 by doping the As site with Sb, which results in γ-NaAs 0.95 Sb 0.05 Se 2 is reported. The congruent melting behavior is confirmed by differential thermal analysis with a melting temperature of 450 °C and crystallization temperature of 415 °C. Single crystals with dimensions of 3 mm × 2 mm are successfully obtained via zone refining and the Bridgman method. The purification of the material plays a significant role in crystal growth and results in a bandgap of 1.78 eV and thermal conductivity of 0.79 Wm —1 K —1 . The single-crystal SHG coefficient of γ-NaAs 0.95 Sb 0.05 Se 2 exhibits an enormous value of |d 11 | = 648 ± 74 pm V —1 , which is comparable to that of γ-NaAsSe 2 and ≈20× larger than that of AgGaSe 2 . Importantly, the bandgap of γ-NaAs 0.95 Sb 0.05 Se 2 (1.78 eV) is similar to that of AgGaSe 2 , thus rendering it highly attractive as a high-performing nonlinear optical material.

36 MATERIALS SCIENCE↗

Sample registration software for process automation in the Neutron Activation Analysis (NAA) Facility in Malaysia nuclear agency

Neutron Activation Analysis (NAA) had been established in Nuclear Malaysia since 1980s. Most of the procedures established were done manually including sample registration. The samples were recorded manually in a logbook and given ID number. Then all samples, standards, SRM and blank were recorded on the irradiation vial and several forms prior to irradiation. These manual procedures carried out by the NAA laboratory personnel were time consuming and not efficient. Sample registration software is developed as part of IAEA/CRP project on ‘Development of Process Automation in the Neutron Activation Analysis (NAA) Facility in Malaysia Nuclear Agency (RC17399)’. The objective of the project is to create a pc-based data entry software during sample preparation stage. This is an effective method to replace redundant manual data entries that needs to be completed by laboratory personnel. The software developed will automatically generate sample code for each sample in one batch, create printable registration forms for administration purpose, and store selected parameters that will be passed to sample analysis program. The software is developed by using National Instruments Labview 8.6.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inspection of Dry Storage Casks Using PGAA and NAA Techniques

In this effort, an assessment of a chloride detection method is performed for inspecting the surfaces of dry cask storage system (DCSS) canisters, with focus on the implementation of a non-destructive nuclear analysis and methodology. Some DCSS canisters (especially those located in coastal environments) will be exposed to marine environments, which can cause atmospheric stress corrosion cracking (SCC). Chloride deposits on canister surfaces provide the corrosive environment necessary for atmospheric SCC with the residual stresses and materials properties conditions. The most susceptible regions on the canister surface are the weld areas, or where cold work has been performed, and may provide the necessary driving force for crack growth. The heat-affected zones (HAZs) near welds are also potentially susceptible to atmospheric SCC due to sensitization of the material caused by chromium depletion during the welding process. Information collected from the field and from laboratory studies has not been able to rule out the possibility of atmospheric chloride induced stress corrosion cracking (CISCC), although no occurrences of atmospheric SCC in DCSS canisters have been detected to-date. A number of researchers have demonstrated that localized corrosion can take place under such situations on materials commonly used for interim storage containers, including 304SS (Cook et al. 2010; Shirai et al. 2011) and 316SS (Tani et al. 2009). In this summary, the preliminary results of a neutron activation analysis (NAA) and prompt gamma activation analysis (PGAA) are performed using MCNP6, a highly sophisticated, multi-particle Monte Carlo simulation code (with the employment of the high performance computing system at the Idaho National Laboratory), and confirm the feasibility of using PGAA and NAA as an environmental inspection methodology for detection and monitoring of small quantities of chlorine on canister surfaces. The specific signature of gamma rays due reactions of sea salt constituents are documented and summarized in this paper. The environmental constituent for passive oxide film breaching is chlorine, which can cause pitting initiation and incubation time that may lead to cracking in stainless steel. Therefore, an assessment of chloride presence at a canister surface is essential before moving to other nondestructive analysis (NDA) methods for detection of pitting and cracking. Two nonlinear acoustic techniques will also be used in our integrated research project (IRP) research study that proves to be useful in the detection of SCC: nonlinear resonant ultrasound spectroscopy (NRUS), and time revisited elastic nonlinear diagnostic (TREND). These two techniques are complementary to marine atmospheric detection techniques. In this presentation only PGAA and NAA are described in detail. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thin Porous Metal Sheet-Supported NaA Zeolite Membrane for Water/Ethanol Separation

This paper reports preparation and separation testing results of water-selective zeolite membrane, such as NaA (or 4A-type), supported on a robust, porous metal sheet of 50um thickness. The thin sheet support is of large potential for development of a low-cost, inorganic membrane module of high surface area packing density. The porous Ni alloy sheet of micrometer or sub-micrometer mean pore size, which was prepared by a proprietary process, is used to evaluate different zeolite membrane deposition methods and conditions. The membranes are characterized by SEM, XRD and water/ethanol separation tests. Quality NaA zeolite membrane at thickness <2um is obtained with the secondary hydrothermal growth method. This membrane shows water/ethanol separation factor of >10,000 and water permeation flux of about 4 kg/(m2•h) at 75ºC with a feed of 10wt% water in ethanol. The membrane is also demonstrated with good stability in 66-hour continuous testing at 75ºC and 90ºC.

36 MATERIALS SCIENCE↗

K{sub 0}-NAA for the Determination of Trace Elements in a Synthetic Material: a Collaborative Study

As part of an interlaboratory comparison in order to certify a synthetic material to be used for the validation of the proper implementation of k0-NAA a collaborative trial was organised. Based on this collaborative study RSD{sub r} values (repeatability relative standard deviation) ranging typically from 1 to 2% could be achieved, while RSD{sub R} values (reproducibility relative standard deviation) ranged typically from 2 to 5%. These values were then compared with the Horwitz criterium leading to HORRAT values in most cases well below 1, although two exceeding 1, depending on the element to be determined. It could be concluded that k{sub 0}-NAA is a very precise method, but that still some inconsistencies for certain elements do exist.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NAA For Human Serum Analysis: Comparison With Conventional Analyses

Instrumental and Comparator methods of Neutron Activation Analysis (NAA) were applied to determine elements of clinical relevancy in serum samples of adult population (Sao Paulo city, Brazil). A comparison with the conventional analyses, Colorimetric for calcium, Titrymetric for chlorine and Ion Specific Electrode for sodium and potassium determination were also performed permitting a discussion about the performance of NAA methods for clinical chemistry research.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Prompt gamma activation analysis (PGAA) and short-lived neutron activation analysis (NAA) applied to the characterization of legacy materials

Without quality historical records that provide the composition of legacy materials, the elemental and/or chemical characterization of such materials requires a manual analytical strategy that may expose the analyst to unknown toxicological hazards. In addition, much of the existing legacy inventory also incorporates radioactivity, and, although radiological composition may be determined by various nuclear-analytical methods, most importantly, gamma-spectroscopy, current methods of chemical characterization still require direct sample manipulation, thereby presenting special problems with broad implications for both the analyst and the environment. Alternately, prompt gamma activation analysis (PGAA) provides a'single-shot' in-situ, non-destructive method that provides a complete assay of all major entrained elemental constituents.1-3. Additionally, neutron activation analysis (NAA) using short-lived activation products complements PGAA and is especially useful when NAA activation surpasses the PGAA in elemental sensitivity.

07 ISOTOPE AND RADIATION SOURCES↗

Materials Data on NaAs by Materials Project

NaAs is Tetraauricupride structured and crystallizes in the tetragonal P4/mmm space group. The structure is three-dimensional. Na1+ is bonded in a 12-coordinate geometry to eight equivalent As1- atoms. All Na–As bond lengths are 3.11 Å. As1- is bonded to eight equivalent Na1+ atoms to form a mixture of distorted corner, edge, and face-sharing AsNa8 cuboctahedra.

36 MATERIALS SCIENCE↗

Materials Data on NaAs by Materials Project

NaAs crystallizes in the orthorhombic P2_12_12_1 space group. The structure is three-dimensional. there are two inequivalent Na1+ sites. In the first Na1+ site, Na1+ is bonded in a 5-coordinate geometry to five As1- atoms. There are a spread of Na–As bond distances ranging from 2.97–3.11 Å. In the second Na1+ site, Na1+ is bonded in a 6-coordinate geometry to six As1- atoms. There are a spread of Na–As bond distances ranging from 3.01–3.20 Å. There are two inequivalent As1- sites. In the first As1- site, As1- is bonded in a 8-coordinate geometry to six Na1+ and two equivalent As1- atoms. There are one shorter (2.49 Å) and one longer (2.53 Å) As–As bond lengths. In the second As1- site, As1- is bonded in a 7-coordinate geometry to five Na1+ and two equivalent As1- atoms.

36 MATERIALS SCIENCE↗

Materials Data on NaAs by Materials Project

NaAs crystallizes in the monoclinic P2_1/c space group. The structure is three-dimensional. there are two inequivalent Na1+ sites. In the first Na1+ site, Na1+ is bonded in a 6-coordinate geometry to six As1- atoms. There are a spread of Na–As bond distances ranging from 3.04–3.17 Å. In the second Na1+ site, Na1+ is bonded in a 6-coordinate geometry to six As1- atoms. There are a spread of Na–As bond distances ranging from 3.08–3.26 Å. There are two inequivalent As1- sites. In the first As1- site, As1- is bonded in a 8-coordinate geometry to six Na1+ and two equivalent As1- atoms. There are one shorter (2.49 Å) and one longer (2.53 Å) As–As bond lengths. In the second As1- site, As1- is bonded in a 8-coordinate geometry to six Na1+ and two equivalent As1- atoms.

36 MATERIALS SCIENCE↗

NAA TECHNIQUE FOR CLINICAL INVESTIGATION OF MICE IMMUNIZED WITH BOTHROP VENOM

In the present study Neutron Activation Analysis (NAA) technique was used to determine sodium concentration in whole blood of mice immunized with Bothrops venom. With this value it was possible to perform clinical investigation in this animal model using whole blood.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ANALYSIS IN BLOOD OF GOLDEN HAMSTER BY NAA FOR CLINICAL PRACTICE

In the present study Neutron Activation Analysis (NAA) technique has been used to determine, simultaneously, some element concentrations of clinical relevance in whole blood samples of Golden Hamster. The normal range for Br, Cl, K and Na concentrations were determined. The knowledge of these values permits clinical investigation of animal model using whole blood as well as to check the similarities with human blood.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sodium Analysis in Whole Blood of Athletes Using NAA

In this investigation the sodium levels in blood were analyzed in athletes submitted to constant load exercise at treadmill (LABEX and UNICAMP) by NAA. These data were compared with the rest condition (before starting the exercise program) as well as with the sodium levels of the healthy group (control group) select from Blood Banks. The results showed alterations in sodium levels of the athletes during the exercise training, mainly increase, suggesting the necessity of its evaluation during physical activities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of saliva of patients with periodontal disease using NAA

In this study the non-stimulated whole saliva of 26 healthy subjects (mean age 33.9 {+-} 11.0 years, range: 26 to 49 years) and 11 patients with periodontal disease (mean age 41.7 {+-} 11.5 years; range 29 to 55 years) was investigated using Neutron Activation Analysis (NAA) technique. The samples were obtained from donors at Sao Paulo city (Brazil). The analyses were performed in the nuclear reactor IEA-R1 (3.5-4.5MW, pool type) at IPEN/CNEN-SP (Brazil). Considerable changes in Ca and S saliva's level were identified in patients with periodontal disease suggesting they can be used as monitors of periodontal diseases.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Concentration of Ca in blood of amateur runners using NAA

In this study the Ca levels were determined in amateur runners blood at LABEX (Laboratorio de Bioquimica do Exercicio - UNICAMP, Brazil), using Neutron Activation Analyses (NAA) technique. The range established at rest (162 - 410 mgL{sup -1}) when compared with control group (51 - 439 mgL{sup -1}) suggests that there is a dependency of these limits in the function of the adopted physical training.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensitivity analysis towards trace-uranium detection with γ-γ coincidence NAA

An improved approach for detection of trace amounts of 238 U by means of neutron activation analysis (NAA) is presented. The analysis enhancement is obtained by utilizing γ-γ coincidence counting. An empirical method for evaluating the sensitivity gain in the presence of a large source-related background is presented. A comparison of detection limits is made between two counting schemes; namely, counting single gammas using one HPGe detector versus counting coincident gammas using two HPGe detectors placed face-to-face. Furthermore, a data-validated radiation transport model, created in GEANT4 for a single HPGe detector, is extended to handle the two detector setup. In this counting scheme, a 238 U-detection sensitivity enhancement of about a factor of 8 is predicted for a sample of Saint-Gobain G3 Sapphire when compared to the simpler singles counting approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of NAA to Detect Uptake of Uranium and other Elements in Adsorbents

A consortium of national lab and university partners, led by Oak Ridge (ORNL) and Pacific Northwest (PNNL) National Laboratories, has been working on the development of fibers with the ability to passively adsorb uranium out of seawater. In experiments by PNNL, the adsorption capacity of these fibers was observed to decrease by up to 30% as an effect of marine biofouling. In order to increase the cost-effectiveness of the process, the project ultimately aims to mitigate the effect of fouling by adding antimicrobial agents such as Ag nanoparticles to the adsorbents. To work towards this goal, a method of producing fiber surrogates for the specialized uranium adsorbents was established. This enabled researcher to complete fouling trials at a faster rate and lower cost. Additionally, the project has proven Neutron Activation Analysis (NAA) to be a viable process for measuring the uptake in fibers. The technique stands out because of its ability to measure low concentrations of uranium and other elements with high sensitivity.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗