Search NASA⌕ Search

SEARCH · Search NASA

Results for “NaI(OF)2”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Materials Data on NaI(OF)2 by Materials Project

NaI(OF)2 crystallizes in the orthorhombic Cmcm space group. The structure is three-dimensional. Na1+ is bonded to two equivalent O2- and four equivalent F1- atoms to form edge-sharing NaO2F4 octahedra. Both Na–O bond lengths are 2.39 Å. All Na–F bond lengths are 2.39 Å. O2- is bonded in a distorted bent 150 degrees geometry to one Na1+ and one I5+ atom. The O–I bond length is 1.80 Å. I5+ is bonded in a distorted see-saw-like geometry to two equivalent O2- and two equivalent F1- atoms. Both I–F bond lengths are 2.07 Å. F1- is bonded in a distorted trigonal planar geometry to two equivalent Na1+ and one I5+ atom.

36 MATERIALS SCIENCE↗

A comprehensive final summary of the MCNP calculations performed concerning the UW 137 Cs release event

This document combines and supersedes earlier reports (e.g. LA-UR-19-32358 and LA-UR-20- 22216) that discussed MCNP-calculated conversion factors (count rate per unit activity per unit area) for collimated 2”x2” NaI detectors (Ludlum model 44-10 and Thermo model SPA3) in contact with various surfaces of interest to the University of Washington 137 Cs release event. These surfaces include: Exterior surface of round and rectangular ducts, Exterior surface of outdoor brick work, Exterior surface of cast iron pipes, Exterior surface of an O 2 filter assembly For each surface, the calculated conversion factors allowed inferences on 137 Cs activity on interior surfaces based on exterior contact measurements of the 662 keV photopeak count rate. The MCNP calculations included the effect of attached collimators (i.e. either a Pb/Sb-based Ludlum or a W-based “Rees” model) on detector response. As a consequence, the conversion factors only apply to the appropriate collimated 2”x2” NaI detector operated in pulse height analysis (PHA) mode. Other assumptions affecting the calculations and valid application of the conversion factors will be outlined below.

54 ENVIRONMENTAL SCIENCES↗

AMS / BARC Joint Survey Addendum Technical Report

This report details the data analysis results from data collected during the September-October 2019 joint survey series between the Department of Energy (DOE) National Nuclear Security Administration (NNSA) Aerial Measuring System (AMS) asset, and the Government of India’s Department of Atomic Energy (DAE) Bhabha Atomic Research Centre (BARC). This joint survey series took place at the Nevada National Security Site (NNSS), areas of public land in Southern Nevada, and at the DOE Office of Legacy Management (LM) Large Area Calibration Pads (LACP) at the Grand Junction Regional Airport in Grand Junction, CO. The data detailed in this report were gathered at the LACP. More details regarding the setup of these surveys and personnel involvement can be found in the AMS / BARC Joint Survey Summary Report. The data from the LACP collected by AMS are consistent with past data collection campaigns at the LACP. The AMS Bell 412 (B412) helicopter, equipped with both the standard AMS thallium-doped sodium iodide (NaI(Tl)) 2"x4"x16" 12-detector system and a subset of the BARC Aerial Gamma Spectroscopy System (AGSS) consisting of two independent 3"x3"cylindrical NaI(Tl) detectors, measured each of the five calibration pads for a minimum of 10 minutes. After the helicopter measurements, a pressurized ion chamber (PIC) was used to directly measure radiation exposure rates on each of the pads for a period 5 minutes. The geophysical calibration procedure published by the International Atomic Energy Agency (IAEA) (Erdi-Krausz et al. 2003) was used to determine the spectral stripping sensitivity matrix for naturally occurring radiological material (NORM). The sensitivity matrix is consistent with the AMS long term average. Additionally, the PIC data was used to calibrate the AMS system for exposure rate. The results of the exposure rate analysis are also consistent with AMS long-term averages.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MCNP modelling of the Thermo SPA3 with Tungsten (Rees model) collimator

A Thermo Model SPA3 2”x2” NaI probe fitted with a Tungsten collimator has been modelled using MCNP6. The collimator was assumed to be machinable Tungsten which typically includes Ni and Fe. Various ratios of these additives are used in industry and for the purposes of these calculations the collimator was assumed to contain 7% Ni and 3% Fe with a density of 17.0 g/cm 3 . The dimensions of the collimator were based on measurements taken by Mike Fanning. The above detector model was used, in a manner similar to the approach described in LA-UR-19-32358, to calculate photopeak count rates per unit activity per unit area (i.e. cpm per pCi/cm 2 ) conversion factors for various contamination scenarios.

61 RADIATION PROTECTION AND DOSIMETRY↗

MCNP calculations concerning the UW 137 Cs release event (Final Report)

This document supersedes earlier reports (LA-UR-19-32358 and LA-UR-20-22216) that discussed MCNP-calculated conversion factors (count rate per unit activity per unit area) for collimated 2”x2” NaI detectors (Ludlum model 44-10 and Thermo model SPA3) in contact with duct and plenum walls. Specifically, for duct and plenum dimensions and construction details of interest to the University of Washington ¹³⁷Cs release event. This document also corrects some of the data presented in the earlier LA-UR reports.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detecting Low-level Radiation Sources Using Border Monitoring Gamma Sensors

We consider a problem of detecting a low-level radiation source using a network of Gamma spectral sensors placed on the periphery of a monitored region. We propose a computationally light-weight, correlation-based method which is primarily intended for systems with limited computing capacity. Sensor measurements are combined at the fusion by first generating decisions at each time step and then taking their majority vote within a time widow. At each time step, decisions are generated using two strategies: (i) SUM method based on a threshold decision on a correlation statistic derived from measurements from all sensors, and (ii) OR method based on logical-OR of threshold decisions based on correlations statistics of individual sensor measurements. We derive analytical performance bounds for false alarm rates of SUM and OR methods, and show that their performance is enhanced by the temporal smoothing of majority vote within a time window. Using measurements from a test campaign, we generate a border monitoring scenario with twelve 2"x2" NaI Gamma sensors deployed on the periphery of 42m x 42m outdoor region. A Cs-137 source is moved in a straight-line across this region, starting several meters outside and finally moving away from it. We illustrate the performance of both correlation-based detection methods, and compare their performances with each other and with a particle filter method. Overall, under small false-alarm conditions, the OR fusion is found to produce better detection performance.

Sen, Satyabrata↗

Hofmeister Effect in RT-QuIC Seeding Activity of Chronic Wasting Disease Prions

Chronic wasting disease (CWD) is a transmissible spongiform encephalopathy (TSE) that causes a fatal neurodegenerative disease in cervids. Cases of CWD are rapidly increasing in North America among wild and farmed cervid populations, and potential for zoonotic transmission is not yet determined. Therefore, in order to manage the disease, it is imperative to devise a system that can detect CWD during its early phases to prevent spread to new captive herds through introduction of CWD-affected animals into otherwise CWD-free herds. Real-time quaking–induced conversion (RT-QuIC) assays have been applied to detect the presence of disease-associated prions from various samples in both animals and humans. In this study, we have tested the use of five Hofmeister anions that range from weakly hydrating to strongly hydrating: Na 3 citrate, Na 2 SO 4 , NaCl, NaI, and NaClO 4 in RT-QuIC reactions for CWD seeding activity using different recombinant prion proteins as substrates. This work shows how the ionic environment of the RT-QuIC reaction can enhance or diminish the seeding activity. The use of Na 2 SO 4 or NaI as the sodium salt for RT-QuIC using bank vole recombinant prion substrate for the detection of CWD using brain samples reduces the lag time to detect with reasonable specificity. For detection of the CWD in fecal samples, only NaI showed comparable reduction in lag time relative to NaCl but required reduced temperature to alleviate spontaneous fibril formation in negative control samples. Selection of the proper ion environment and recombinant prion protein substrate will make RT-QuIC a powerful diagnostic tool for early detection of CWD prions, further supporting CWD surveillance in wild and captive cervids.

59 BASIC BIOLOGICAL SCIENCES↗

Generation of Synthetic Data for a Radiation Detection Algorithm Competition

This paper details the generation of synthetic radiation data using large-scale Monte Carlo transport models to evaluate radiation search detection algorithms. Modular 3-D Monte Carlo models spanning multiple city blocks were constructed, loosely based on downtown Knoxville, TN, containing buildings composed of multiple materials (brick, granite, and concrete), sidewalks, a four-lane road, side streets, parking lots, and grassy fields. Background and simulated source detector response calculations from these models were used to create synthetic list mode data sets for a 2"×4"×16" NaI(Tl) detector moving through a city street at a constant speed. For the background simulations, major isotopes were computed individually so that background composition and variability could be computed efficiently outside Monte Carlo. The source detector response included six simulated sources placed at 15 source locations. Detector response was developed to be periodic through the city street so that a detector path could begin at one end of the model and wrap around to the other. This framework allowed for the creation of diverse data sets, each with its own unique background and simulated source detector response. Synthetic data allows for high-quality labels, which are useful in developing data-driven radiation detection algorithms. This methodology was used to create synthetic data sets which were released as part of a public data competition to spur the development of new radiation detection algorithms for radiological search applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neural Network Approaches for Mobile Spectroscopic Gamma-Ray Source Detection

Artificial neural networks (ANNs) for performing spectroscopic gamma-ray source identification have been previously introduced, primarily for applications in controlled laboratory settings. To understand the utility of these methods in scenarios and environments more relevant to nuclear safety and security, this work examines the use of ANNs for mobile detection, which involves highly variable gamma-ray background, low signal-to-noise ratio measurements, and low false alarm rates. Simulated data from a 2” × 4” × 16” NaI(Tl) detector are used in this work for demonstrating these concepts, and the minimum detectable activity (MDA) is used as a performance metric in assessing model performance.In addition to examining simultaneous detection and identification, binary spectral anomaly detection using autoencoders is introduced in this work, and benchmarked using detection methods based on Non-negative Matrix Factorization (NMF) and Principal Component Analysis (PCA). On average, the autoencoder provides a 12% and 23% improvement over NMF- and PCA-based detection methods, respectively. Additionally, source identification using ANNs is extended to leverage temporal dynamics by means of recurrent neural networks, and these time-dependent models outperform their time-independent counterparts by 17% for the analysis examined here. The paper concludes with a discussion on tradeoffs between the ANN-based approaches and the benchmark methods examined here.

Bilton, Kyle J. (ORCID:0000000184553689)↗

Gamma Equipment System Requirements by Application

This document outlines a set of requirements for gamma sensitive systems applied to three different applications: (1) homeland security (search and identification); (2) in-situ quantification; and (3) quantification in a material characterization laboratory. These three applications represent a range of activities that a country might use for locating, identifying, and quantifying radioactive material. These applications require increasing accuracy and system advancements, and skill levels. This document considers systems with various detector types and are characterized by their energy resolution: (1) low resolution (e.g., NaI(Tl) scintillation) and (2) higher resolution (e.g., high-purity germanium [HPGe] solid state) systems. The higher resolution systems also include cadmium zinc telluride (CZT) and only mechanically cooled HPGe systems are considered. These detectors and their associated acquisition hardware and analysis software afford a broad range of capabilities with corresponding ranges of complexity, maintainability, and cost. Ultimately, the equipment must meet the measurement goals of the application, and compliance with a given list of hardware specifications does not in itself guarantee meeting those goals. Examples of typical performance objectives for international safeguards applications are documented in International Target Values 2010 for Measurement Uncertainties in Safeguarding Nuclear Materials (IAEA, STR-368, November 2010). Selection of the detector type best suited to a specific application is often a compromise between “state of the art” or best available option and what is practical.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

42 ENGINEERING↗

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

Engineering - Instrumentation related to nuclear s↗

Effects of Anionic Polymer Modification of Dye‐Sensitized Niobate Photocatalysts on Solar‐Driven Z‐Scheme Overall Water Splitting

Pt‐intercalated calcium niobate nanosheets (Pt/HCa 2 Nb 3 O 10 ) sensitized by a Ru(II) complex dye are good photocatalysts for producing H 2 from aqueous solutions containing I − as a reversible electron donor. These materials are applicable to Z‐scheme overall water splitting in combination with a WO 3 ‐based O 2 ‐evolving photocatalyst under simulated sunlight. In this work, the effects of anionic polymer modification of the dye‐sensitized nanosheets are examined by adsorbing sodium poly(styrenesulfonate) (PSS), sodium polyacrylate, sodium polymethacrylate (PMA), or sodium poly(4‐styrenesulfonic‐ co ‐maleic acid) onto the dye‐sensitized nanosheet surface. For half‐cell H 2 ‐evolution reaction in the presence of NaI, all of the polymers have a positive impact on the activity under visible light at lower light intensity, whereas only PMA is effective under high light‐intensity condition. For Z‐scheme overall water splitting with PtO x /H‐Cs‐WO 3 , PSS and PMA give almost the same solar‐to‐hydrogen energy conversion efficiencies (0.12% ± 0.01%) under optimized conditions. However, PMA operates better than PSS at relatively low and high NaI concentrations, which are in general disadvantageous for the H 2 ‐ and O 2 ‐evolving components of the Z‐scheme, respectively.

Energy & Fuels↗

Catalyzed oxidation of nuclear graphite by simulated fission products Sr, Eu, and I

The influence of three fission products Sr, Eu, and I on the oxidation of IG-110 nuclear graphite was studied in the temperature range of 400 to 1000 °C. Sr and Eu were introduced as chlorides, and I was introduced as NaI. The temperature dependence of both CO 2 and CO production during the graphite oxidation measured with mass spectroscopy and infrared spectrometry shows that the introduction of these three compounds to graphite significantly decreases the onset temperature for the oxidation of graphite. Among the three compounds, NaI is the most active towards the oxidation reaction, characterized by a significant decrease of the onset temperature from approximately 650 to 400 °C before and after its introduction to graphite. Separate measurements of CO 2 and CO concentration at varying temperatures enable the calculation of the activation energy for the formation of CO 2 and CO. The activation energies for the oxidation of pure and fission product-impregnated graphite samples decrease in the following order: standard IG-110 graphite, EuCl 3 -impregnated IG-110, SrCl 2 -impregnated IG-110, and NaI-impregnated IG-110. This trend indicates that the three compounds catalyze the oxidation of graphite at temperatures relevant to the operation of high-temperature gas-cooled reactors. Furthermore, it is found that the three compounds can also affect the molar ratio of reaction products CO 2 and CO, and the rates of the graphite oxidation. At temperatures higher than about 850 °C, the impregnated samples exhibit lower CO 2 : CO ratios than the pure graphite. Different from EuCl 3 and NaI, the introduction of SrCl 2 decreases the graphite oxidation rates at temperatures higher than about 770 °C. Their catalytic mechanism can be understood based on a redox cycle of the intermediate active species, promoting the dissociation of molecular oxygen and transfer to the carbon.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Drones for Decommissioning

The U.S. Nuclear Regulatory Commission has responsibility for regulating the safe decommissioning of facilities and sites to meet the License Termination Rule in 10 Code of Federal Regulations (CFR) Part 20, Standards for Protection Against Radiation, Subpart E “Radiological Criteria for License Termination.” Decommissioning is performed in accordance with 10 CFR Part 50, Domestic Licensing of Production and Utilization Facilities, as part of license termination (§50.82) and release of the facility or site for unrestricted use (§50.83). The guidance currently demonstrates the minimum requirements and necessary conditions for conducting radiological surveys by a person carrying a radiation detector(s). The Pacific Northwest National Laboratory (PNNL) evaluated the use of an unoccupied aerial vehicle (UAV) to conduct radiological surveys that could be used in decommissioning to potentially reduce time, cost, and worker safety compared to current survey methods. The objective of this project was to evaluate the performance and limitations of a UAV to support a decommissioning radiological survey and compare it to a radiological survey conducted by a human. The primary research questions of interest evaluated were: 1. Did observed UAV paths differ from human paths and, if so, how much? 2. Did survey path deviation affect survey results and, if so, how? 3. Were radiological measurements from human and UAV surveys significantly different? To answer these research questions, an experimental field was set up at PNNL’s 3440 test track, and it included radiological sources commonly surveyed during decommissioning: cobalt-60 (Co-60), cesium-137 (Cs-137), and americium-241 (Am-241). Nine check sources (three each of Am-241, Cs-137, and Co-60) with activities ranging from 3.54 µCi to 39.34 µCi were set over a path that also included an area for measuring background radiation. An Aurelia X6 UAV coupled with a GPS and lidar unit was used to conduct the radiological surveys. UAV and human surveys were conducted using two different NaI(Tl) scintillation radiation detectors (2 in. × 2 in. Ludlum, Inc. and 2 in. × 0.04 in. Alpha Spectra, Inc.) at a travel velocity of approximately 0.2 m/s at a low (15–40 cm median altitude) or high (87–105 cm median altitude) survey altitude. Since the survey velocity and altitude parameters were atypical for normal UAV operations, testing was done prior to conducting the radiological surveys to establish airworthiness, evaluate the navigation system, and establish flight control. Human and UAV surveys were paired according to the detector type and altitude regime to compare the survey data. The results of this proof-of-concept research determined that the UAV and human surveys followed similar survey paths and detected the radiological sources with no significant statistical difference (in 33 out of 36 surveys). However, further research is needed prior to deploying UAVs for decommissioning surveys.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Photon detector response function methodology using MCNP and shift hybrid radiation transport code for wide-area contamination assay applications

Here, radiation transport modeling using the Monte Carlo N-Particle (MCNP) radiation transport code and Monte Carlo code, Shift, were employed to model detector responses for a variety of wide-area photon contamination scenarios. In this study, 2" × 2" and 3" × 3" cylindrical NaI(Tl) scintillation detector configurations at source detector-distances of 0.5 cm, 1 cm, 2.54 cm, 10 cm, and 30 cm were modeled. Media of soil, concrete, and steel were evaluated for contamination depths ranging from surface to a depth of an infinite thickness in each medium for photon energies ranging from 20 keV to 3 MeV, which correspond to the energies that current detectors can discern. Monoenergetic photon surface contamination detector responses for each of the media, source–detector distances, and detectors were estimated using MCNP v6.2. Shift was harnessed for improved variance reduction of particle transport in highly attenuating media to obtain average cell fluxes in the two MCNP NaI(Tl) scintillation detector configurations. Average cell flux values in Shift were coupled with detector responses from MCNP to convert average cell flux in a void to energy distribution of pulses in the NaI(Tl) scintillation detector crystal of interest. An optimized detector response function methodology was developed by coupling the MCNP radiation transport method with the Consistent Adjoint Driven Importance Sampling (CADIS) hybrid radiation transport method built into Shift to significantly decrease the runtime of thousands of MCNP pulse height simulations. The methodology may be utilized to quickly and accurately facilitate the assessment of a broad range of wide-area environmental contamination assay and decommissioning cleanup applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge Transfer Dynamics in Dye-Sensitized Photocatalysts Using Metal Complex Sensitizers with Long-Wavelength Visible Light Absorption Based on Singlet–Triplet Excitation

An Os(II) polypyridyl complex was applied as a photosensitizer in dye-sensitized photocatalyst systems based on Pt-intercalated HCa 2 Nb 3 O 10 and Pt-loaded TiO 2 . The Os(II) complex exhibits a spin-forbidden but partially allowed triplet metal-to-ligand charge transfer ( 3 MLCT) transition, enabling broad visible light absorption up to 800 nm, which surpasses that of conventional Ru(II)-based dyes. Despite its shorter excited-state lifetime compared to Ru(II) complexes, efficient electron injection from the excited Os(II) dye into the semiconductor was confirmed. Under visible-light irradiation, the Os(II)- sensitized photocatalysts showed higher H 2 evolution activity than the Ru(II)-sensitized photocatalysts when sodium ascorbate was used as an electron donor, demonstrating effective utilization of long-wavelength visible light. In contrast, negligible H 2 evolution was observed when NaI was employed as a redox mediator for Z-scheme water splitting. Transient absorption spectroscopy revealed that the lack of activity stemmed from inefficient electron transfer from I − to oxidized Os(II). These findings highlight the importance of selecting appropriate redox mediators to fully exploit long-wavelength dyes for overall water splitting under visible light.

artificial photosynthesis↗

Spatially resolved x-ray detection with photonic crystal scintillators

We study the self-collimation phenomenon in photonic crystals (PhC) of wide bandgap materials for ultra-fast and high spatial resolution x-ray detection. We work on various heavy inorganic scintillators: BaF 2 , GaN, ZnO, CsI:Tl, NaI:Tl, LYSO, WO 4 compounds, and plastic scintillators. Conventional scintillator detectors do not rely on a direct detection mechanism; hence, they require intricate design and fabrication processes. We offer a PhC design to observe self-collimation phenomena and overcome the ongoing spatial resolution challenges with these types of materials. We investigate the photonic band diagrams and iso-frequency contours. Fourier transforms based on finite-difference time-domain and frequency domain simulations are done for verifying and analyzing the self-collimation with the selected material. Light extraction efficiency at the PhC–air interface, depending on the truncation distance from the excitation point, is measured. Beam divergence values are calculated at 1 mm propagation distance. The vertical field profiles are obtained to observe the confinement. For the spatial resolution analysis, cross-sectional beam profiles have been examined. Furthermore, Gaussian envelopes are fitted to beam profiles for a consistent data analysis, and full-width-at-half-maximum values are considered. As a result, we theoretically prove and demonstrate the spatially resolved x-ray detection at the sub-micrometer level for a wide range of scintillator materials.

36 MATERIALS SCIENCE↗