Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nanosecond laser ablation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evolution and persistence of SiO emission in nanosecond laser ablation plumes

Analyzing laser-produced plasmas in a controlled oxygen-containing environment provides insight into the formation and evolution of molecular species through gas-phase oxidation. This study explores the role of ambient pressure and oxygen availability in forming SiO molecular species in laser ablation plumes. The self-emission emanating during the reactive ablation of Si targets was characterized by optical emission spectroscopy and optical time-of-flight techniques. Our results showed that the SiO species formation was greatly influenced by both the ambient pressure and oxygen availability. The intensity and the persistence of SiO emission bands are lower at higher oxygen concentrations, indicating they are depopulated by the formation of more complex silicon oxides. The oxygen partial pressure effects on plume chemistry showed that SiO formation is favored even with a minimal oxygen concentration in the environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single-shot, double-pulse determination of the detonation energy in nanosecond-laser ablation using the blast model

We demonstrate a novel single-shot method to determine the detonation energy of laser-induced plasma and investigate its performance. This approach can be used in cases where there are significant shot-to-shot variations in ablation conditions, such as laser fluctuations, target inhomogeneity, or multiple filamentation with ultrashort pulses. The Sedov blast model is used to fit two time-delayed shadowgrams measured with a double-pulse laser. We find that the reconstruction of detonation parameters is insensitive to the choice of interpulse delay in double-pulse shadowgraphy. In contrast, the initial assumption of expansion dimensionality has a large impact on the reconstructed detonation energy. The method allows for a reduction in the uncertainties of blast wave energy measurements as a diagnostic technique employed in various laser ablation applications.

42 ENGINEERING↗

Investigating laser ablated plume dynamics of carbon and aluminum targets

Recently acquired high-resolution images of nanosecond laser ablation plumes suggest a strong correlation between the internal plume structure and the type of material being ablated. However, the details of this relation are currently not well understood. In this work, we attempt to explore this correlation using a 2D radiation hydrodynamics model to study the dependence of internal plume structure formation on the ablation material. Here spatio-temporal emission maps and plume expansion velocities from experimental measurements are compared with the model predictions, including synthetic emission maps. The shape and expansion rate of an outer air plume region are found to be in good agreement for both carbon and aluminum, as are the inner material plume dynamics for carbon ablation. The largest disagreement is observed in the case of a polished aluminum target, where the chaotic inner plume features seen in the experimental images are not observed in the model. The possible physical mechanisms responsible for this discrepancy are discussed. This effort constitutes a continued development toward a predictive model of ablation plume dynamics and chemistry for various materials in extreme environments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of environmental oxygen on nanoparticle formation and agglomeration in aluminum laser ablation plumes

Here, the role of ambient oxygen gas (O 2 ) on molecular and nanoparticle formation and agglomeration was studied in laser ablation plumes. As a lab-scale surrogate to a high explosion detonation event, nanosecond laser ablation of an aluminum alloy (AA6061) target was performed in atmospheric pressure conditions. Optical emission spectroscopy and two mass spectrometry techniques were used to monitor the early to late stages of plasma generation to track the evolution of atoms, molecules, clusters, nanoparticles, and agglomerates. The experiments were performed under atmospheric pressure air, atmospheric pressure nitrogen, and 20% and 5% O 2 (balance N 2 ), the latter specifically with in situ mass spectrometry. Electron microscopy was performed ex situ to identify crystal structure and elemental distributions in individual nanoparticles. We find that the presence of ≈20% O 2 leads to strong AlO emission, whereas in a flowing N 2 environment (with trace O 2 ), AlN and strong, unreacted Al emissions are present. In situ mass spectrometry reveals that as O 2 availability increases, Al oxide cluster size increases. Nanoparticle agglomerates formed in air are found to be larger than those formed under N 2 gas. High-resolution transmission electron microscopy demonstrates that Al 2 O 3 and AlN nanoparticle agglomerates are formed in both environments; indicating that the presence of trace O 2 can lead to Al 2 O 3 nanoparticle formation. The present results highlight that the availability of O 2 in the ambient gas significantly impacts spectral signatures, cluster size, and nanoparticle agglomeration behavior. These results are relevant to understanding debris formation in an explosion event, and interpreting data from forensic investigations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spectroscopic signatures and oxidation characteristics of nanosecond laser-induced cerium plasmas

Improving technologies related to the wide area environmental sampling of nuclear materials supports the nuclear nonproliferation mission of preventing the proliferation of nuclear weapons by monitoring nuclear weapons tests and detecting undeclared nuclear fuel cycle activities. Standoff, laser-based detection techniques such as laser-induced breakdown spectroscopy have the potential to offer robust, field-deployable methods that provide rapid element-specific and phase identifiable measurements over a wide range of materials. This work aims to elucidate the effects of atmospheric conditions and oxidation reactions on the highly complex and transient spectroscopic signatures of laser-induced plutonium surrogate plasmas. Time-resolved spectra of nanosecond laser ablation cerium plasmas were measured using laser-induced breakdown spectroscopy in a range of atmospheres containing low to high concentrations of oxygen. Here, the growth of strong CeO molecular emission bands was observed in the visible spectrum, where it was shown that the persistence of CeO is reduced from around 60 μs to 50 μs in oxygen rich atmospheric environments. To further investigate the growth and depletion of CeO in the laser-produced plasma, ratios of CeO-to-Ce emission were generated using integrated intensities corresponding to the Q-branch of the CeO D 1 -X 1 transitions and numerous strong atomic Ce peaks. It was determined that the fastest rate of formation of CeO in argon occurred for moderate oxygen mass fractions between 0.10 and 0.15 while the ratios were reduced at higher oxygen mass fractions (i.e., Y O 2 = 0.20) due to competing oxidation reactions and lower plasma temperatures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparing the kinetics of ionized and neutral atoms from single and multi-element laser-produced plasmas

In this work, kinetics of ion and neutral atom emission features were compared for nanosecond laser-produced plasmas generated from several metal targets (i.e., Al, Ti, Zr, Nb, Ta) and an alloy containing all of these as principal alloying elements. Plasmas were produced by focusing 6 ns, 1064 nm pulses from an Nd:YAG laser on the targets of interest in a vacuum. A Faraday cup was used for collecting ion temporal features while spatially and temporally resolved emission spectroscopy was used for measuring the optical time of flight of various neutral atomic transitions. Our results highlight that most probable ion and atom velocities decay with increasing atomic mass. Trends for ions from the alloy target represent a weighted average where all ions contribute. For both ions and atoms, velocities decrease with increasing heat of vaporization and melting temperature, consistent with the thermal mechanisms that contribute to nanosecond laser ablation. Kinetic energies for neutral atoms from pure metal targets have some variability with atomic mass, whereas kinetic energies for atoms from the alloy target are more similar. These more similar kinetic energies observed for neutral atoms in the multi-element plasma may be attributed to collisions between species from all elements in the Knudsen layer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Femtosecond temperature measurements of laser-shocked copper deduced from the intensity of the x-ray thermal diffuse scattering

We present 50-fs, single-shot measurements of the x-ray thermal diffuse scattering (TDS) from copper foils that have been shocked via nanosecond laser ablation up to pressures above ∼135 GPa. We hence deduce the x-ray Debye–Waller factor, providing a temperature measurement. The targets were laser-shocked with the DiPOLE 100-X laser at the High Energy Density endstation of the European X-ray Free-Electron Laser. Single x-ray pulses, with a photon energy of 18 keV, were scattered from the samples and recorded on Varex detectors. Despite the targets being highly textured (as evinced by large variations in the elastic scattering) and with such texture changing upon compression, the absolute intensity of the azimuthally averaged inelastic TDS between the Bragg peaks is largely insensitive to these changes, and allowing for both Compton scattering and the low-level scattering from a sacrificial ablator layer provides a reliable measurement of $T/Θ^2_D$, where Θ D is the Debye temperature. We compare our results with the predictions of the SESAME 3336 and LEOS 290 equations of state for copper and find good agreement within experimental errors. We, thus, demonstrate that single-shot temperature measurements of dynamically compressed materials can be made via thermal diffuse scattering of XFEL radiation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Shock physics and shadowgraphic measurements of laser-produced cerium plasmas

Shadowgraphic measurements are combined with theory on gas-dynamics to investigate the shock physics associated with nanosecond laser ablation of cerium metal targets. Time-resolved shadowgraphic imaging is performed to measure the propagation and attenuation of the laser-induced shockwave through air and argon atmospheres at various background pressures, where stronger shockwaves characterized by higher propagation velocities are observed for higher ablation laser irradiances and lower pressures. The Rankine-Hugoniot relations are also employed to estimate the pressure, temperature, density, and flow velocity of the shock-heated gas located immediately behind the shock front, predicting larger pressure ratios and higher temperatures for stronger laser-induced shockwaves.

42 ENGINEERING↗

Elemental fractionation in aerosol laser-induced breakdown spectroscopy with nanosecond and femtosecond laser ablation

For the purpose of realizing atmospheric radiation plume tracking, laser-induced breakdown spectroscopy (LIBS) was performed to characterize Cs atomic emissions from airborne nanoparticles in a binary particle matrix using nanosecond and femtosecond laser ablation. As a surrogate to multi-element nuclear fallout particulates, both Cs and Na solutions were mixed with Cu at a 1:1.45 M concentration ratio and aerosolized to study elemental fractionation in atomic emissions, revealing Na I resonance emissions are enhanced whereas Cs I resonance emissions are reduced with Cu present despite sharing similar electronic and chemical properties. Femtosecond laser ablation reduced elemental fractionation effects by more than 50% while retaining the same temporal fractionation trends for Cs and Na. The origin of elemental fractionation in aerosol LIBS was further investigated using Al and Ti aerosols which revealed that the particle matrix induces changes to the local plasma temperature, population of atomic states, and subsequent molecular association and emission.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fast imaging of laser ablation of cerium: Dependence of plasma plume dynamics and structure on native oxide growth

We have imaged the evolution of plasma following nanosecond pulsed laser ablation of cerium in air with sub-10 ns resolution. We find the ablated plasma plume expansion and shape to be strongly dependent on the time after mechanical polishing of the sample surface. After an initial shock front common to both new and aged samples (velocities up to 16 km s ₋1 ), we observe a second front that is relatively localized to the surface vicinity of newly polished samples, but in the case of older samples it moves outward at velocities of up to 4 km s ₋1 . We attribute this behavior to the formation and growth of a native oxide layer on the order of hours after polishing. These results demonstrate that plasma imaging can be used to diagnose the presence of, and evaluate the extent of, thin surface oxides or other compounds that form soon after exposure to some atmosphere. These findings also highlight the need to explicitly consider the presence of such overlayers when modeling laser/metal interaction, when making measurements of vapor phase chemistry, and when analyzing the composition, phase, and morphology of solid particulates formed after the ablation of reactive metals.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Investigation of Oxides of Tantalum Produced by Pulsed Laser Ablation and Continuous Wave Laser Heating

Recent progress has seen multiple Ta 2 O 5 polymorphs generated by different synthesis techniques. However, discrepancies arise when these polymorphs are produced in widely varying thermodynamic conditions and characterized using different techniques. This work aimed to characterize and compare Ta 2 O 5 particles formed at high and low temperatures using nanosecond pulsed laser ablation (PLA) and continuous wave (CW) laser heating of a local area of tantalum in either air or an 18 O 2 atmosphere. Scanning electron microscopy (SEM) and Raman spectroscopy of the micrometer-sized particles generated by PLA were consistent with either a localized amorphous Ta 2 O 5 phase or a similar, but not identical, crystalline β-Ta 2 O 5 phase. The Raman spectrum of the material formed at the point of CW laser impingement was in good agreement with the previously established ceramic “H-Ta 2 O 5 ” phase. TEM and electron diffraction analysis of these particles indicated the phase structure matched an oxygen-vacated superstructure of monoclinic H-Ta 2 O 5 . Further from the point of laser impingement, CW heating produced particles with a Raman spectrum that matched β-Ta 2 O 5 . We confirmed that the high-temperature ceramic phase characterized in previous work by Raman spectroscopy was the same monoclinic phase characterized in different work by TEM and could be produced by direct laser heating of metal in air.

36 MATERIALS SCIENCE↗

FLASH-therapy suitable single-pulse proton generation using TiH 2 under nanosecond laser irradiation

We investigated proton emission from titanium hydride (TiH 2 ) targets irradiated in vacuum by a 6-ns, 1064-nm Nd:YAG laser. Time-of-flight measurements with a Faraday cup and an electrostatic ion analyzer resolved distinct proton peaks at high pulse energies, with yields on the order of 10 9 protons per shot. Systematic scans over pulse energy and up to 1000 repeated shots showed that, while the peak amplitude gradually decreased, the integrated proton number remained nearly constant. This behavior is consistent with surface-induced broadening of the plasma expansion while bulk hydrogen is replenished by diffusion and repeated ablation of fresh TiH 2 layers. Using the measured proton numbers and pulse widths, a simple direct-plasma-injection-style scaling indicates peak currents of ∼100 mA and sub-microsecond pulse durations. The pulse structure and yield satisfy key ultra-high-dose-rate criteria and, together with sustained output over 1000 shots, support TiH 2 -based laser ion sources as practical candidates for FLASH-therapy (ultra-high-dose-rate)-oriented studies and injector development using direct plasma injection.

43 PARTICLE ACCELERATORS↗

Effects of non-equilibrium ionization and excitation on radiation absorption in plasma plumes induced by ablation of metal targets with nanosecond laser pulses

Ionization and radiation absorption in nanosecond laser-induced plasma plumes are routinely modeled using the Saha–Boltzmann equilibrium ionization model (EQM). However, the equilibrium assumption can be inaccurate during the laser pulse when non-equilibrium effects significantly impact radiation absorption. In the present work, the EQM and non-equilibrium collisional-radiative model (CRM) are compared to reveal the effect of plasma non-equilibrium on radiation absorption in non-homogeneous plumes and degree of plasma shielding. Simulations of plume expansion induced by irradiation of a copper target in 1 atm argon background gas with a 10 ns Gaussian pulse at a fluence from 8 Jcm −2 to 14 Jcm −2 are performed with a hybrid computational model that couples a lumped particle direct simulation Monte Carlo method with either CRM or EQM. The simulations show that the EQM strongly underestimates the effects of ionization and radiation absorption compared to CRM and, contrary to the CRM, predict strong ionization of the background gas. The differences between the models are explained by the qualitatively different coupling between plume expansion and dynamics of ionization and exitation processes in the CRM and EQM under conditions when the characteristic times for most radiation- and electron-induced processes are longer than the pulse duration. The CRM-based predictions are also found to agree much better with available experimental data. In conclusion, these results indicate that the model of Saha–Boltzmann equilibrium cannot be used for reliable prediction of the degree of plasma shielding in plumes induced by nanosecond laser pulses or for processing results of spectroscopic measurements at early stages of expansion of such plumes.

Physics - Plasma physics↗

A lumped particle direct simulation Monte-Carlo method combined with the collisional-radiative model for simulations of non-equilibrium laser-induced plasma plumes

Collisional plasma plumes induced by laser irradiation of material targets exhibit large variations in local density as well as ionization and excitation states, making purely hydrodynamic or kinetic simulations inaccurate or infeasible. To address this challenge and capture non-equilibrium effects in laser-induced plasma plumes at arbitrary degrees of ionization, we develop a hybrid computational approach that combines the kinetic direct simulation Monte Carlo (DSMC) method with a collisional-radiative model (CRM). This ℓDSMC-CRM approach utilizes a lumped particle method to represent minor fractions of excited ions in particle-based simulations and a special coarse-graining technique for atomic spectra and photoionization rates, ensuring numerical convergence at reduced computational cost. The hybrid approach is applied to simulate spatially homogeneous relaxation as well as one- and two-dimensional expansions of plasma plumes induced by irradiation of a copper target by a nanosecond laser pulse in a vacuum or background gas. The comparison with an equilibrium model, where local Saha-Boltzmann equilibrium is enforced, shows that the non-equilibrium effects play a dominant role. The equilibrium model can fail to predict the flow structure and strongly underestimate the degree of absorption of laser radiation by the plume. The ℓDSMC-CRM approach is validated against experimental data demonstrating reasonable agreement with the experimental electron density and temperature, while the equilibrium model is found to dramatically underestimate electron density and temperature. The flexibility of the ℓDSMC-CRM approach allows for its seamless integration into existing DSMC frameworks, making it a valuable tool for high-fidelity plasma modeling in laser-material interactions, laser-based manufacturing, and beyond.

97 MATHEMATICS AND COMPUTING↗

Unraveling Spatio-Temporal Chemistry Evolution in Laser Ablation Plumes and Its Relation to Initial Plasma Conditions

The chemistry evolution in a laser ablation plume depends strongly on its initial physical conditions. In this article, we investigate the impact of plasma generation conditions on the interrelated phenomena of expansion dynamics, plasma chemistry, and physical conditions. Plasmas are produced from a uranium metal target in air using nanosecond, femtosecond, and femtosecond filament-assisted laser ablation. Time-resolved two-dimensional spectral imaging was performed for evaluating the spatio-temporal evolu-tion of atoms, diatoms, polyatomic molecules, and nanoparticles in situ. Emission spectral features reveal that molecular formation occurs at early times in both femtosecond and filament ablation plumes, although with different temporal decay. In contrast, mo-lecular formation is found to occur at much later times in nanosecond plasma evolution. Spectral modeling is used to infer tem-poral behavior of plasma excitation temperature, and results highlighted that nanosecond plume temperatures decay rapidly while plumes generated by filament ablation show slowest decay. In this work, we find U atoms and UO molecules co-exist in ultrafast laser produced plasmas even at early times after plasma onset owing to favorable temperatures for molecular formation. Regardless of irradiation conditions, plume emission features showed presence of higher oxides (i.e. UxOy), although with different temporal histories. Our study provides insight into the impact of plasma generation conditions on chemistry evolution in plasmas produced from traditional focused femtosecond, nanosecond, and filament-assisted laser ablation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Generation of shock trains in free liquid jets with a nanosecond green laser

Shock wave trains in liquid jets were previously generated only by ablation with femtosecond x-ray lasers. Here we show that shock trains in water microjets can be also generated using nanosecond green laser pulses with 1- to 10-mJ energy. Furthermore, the ablation of 15-, 20-, 30-, and 70-μm water microjets opened a gap in the jets and launched an initial shock wave. Fully developed shock trains were observed in the 30- and 70-μm jets up to 250-ns delays, and these trains were also transmitted inside the nozzles. A few tens of nanoseconds after the pulse, the shock dynamics and its pressure became similar to the ones generated by x-ray lasers, with a more rapid pressure decay in thinner jets. At time delays exceeding 100 ns in the 30-μm jets, the leading shock pressure stabilized to an approximately constant pressure of 40 MPa. The energy density deposited in the jets was estimated at 30 MJ/cm 3 by comparing the jet gaps in the green and x-ray laser experiments, and matched previous estimates for optical ablation in water. Here, the pressure decay in the 30-μm jets was modeled based on the pressure decay observed in x-ray laser experiments.

74 ATOMIC AND MOLECULAR PHYSICS↗

Gas-phase oxidation and nanoparticle formation in multi-element laser ablation plumes

The evolution from gas-phase oxidation to nanoparticle and agglomerate formation was studied in nanosecond laser-produced plasmas of a multi-principal element alloy target in air. Here gas-phase oxidation of plasma species was monitored in situ via optical emission spectroscopy, while a custom-built single particle mass spectrometer was used to measure size and compositions of agglomerated nanoparticles formed in laser ablation plumes. Ex situ analysis employing transmission electron microscopy was used to study nanoparticle morphology, crystal structure, and element distribution at the nanoscale. Emission spectra indicate that gas-phase oxidation of elements in the alloy target are formed at varying times during plume evolution, and mass spectrometry results indicate fractal agglomerates contain all principal alloying elements and their oxides. Finally, electron microscopy characterization illustrates that these agglomerates consist of multiple material types: sub-10 nm diameter amorphous, multi-element nanoparticles, ≈10–30 nm diameter Ti-rich crystalline oxide nanoparticles, and ejected base material. Results highlight that the multi-component target composition impacts molecular formation in the gas phase and the morphology, composition, and structure of nanoparticles and agglomerates formed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uranium Single Particle Analysis for Simultaneous Fluorine and Uranium Isotopic Determinations via Laser-Induced Breakdown Spectroscopy/Laser Ablation–Multicollector–Inductively Coupled Plasma–Mass Spectrometry

Uranyl fluoride (UO 2 F 2 ) particles (<20 μm) were subjected to first-of-its-kind analysis via simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation multi-collector inductively coupled plasma–mass spectrometry (LA–MC–ICP–MS). Briefly, a nanosecond pulsed high-energy laser was focused onto the sample (particle) surface. In a single laser pulse, the UO 2 F 2 particle was excited/ionized within the microplasma volume, and the emission of light was collected via fiber optics such that emission spectroscopy could be employed for the detection of uranium (U) and fluorine (F). The ablated particle was simultaneously transported into the MC–ICP–MS for high precision isotopic (i.e., 234 U, 235 U, and 238 U) analysis. This method, LIBS/LA–MC–ICP–MS was optimized and employed to rapidly measure 80+ UO 2 F 2 particles, which were subjected to different calcination processes, which results in varying degrees of F loss from the individual particles. In measuring the particles, the average F/U ratios for the populations treated at 100 and 500 °C were 2.78 ± 1.28 and 1.01 ± 0.50, respectively, confirming loss of F through the calcination process. The average 235 U/ 238 U on the particle populations for the 100 and 500 °C were 0.007262 (22) and 0.007231 (23), which was determined to be <0.2% from the expected value. The 234 U/ 238 U ratios on the same particles were 0.000053 (11) and 0.000050 (10) for the 100 and 500 °C, respectively, <10% from the expected value. Notably, each population was analyzed in under 5 min, demonstrating the truly rapid analysis technique presented here in this paper.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗