Search NASA⌕ Search

SEARCH · Search NASA

Results for “Narrow Angle Astrometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Potential of long-baseline infrared interferometry for narrow-angle astrometry

Narrow-angle astrometry has many astrophysical applications, from the measurement of parallaxes to the search for planets around nearby stars. Ground-based long-focus telescopes with photoelectric detectors have achieved accuracies of about 2-3 milliarcsec in 1 h. This accuracy is limited primarily by the atmosphere, and is consistent with models of atmospheric turbulence. However, applying these turbulence models to observations with long-baseline interferometers yields astrometric errors that are far smaller than can be achieved with long-focus telescopes. The predictions for the ultimate accuracy of ground-based narrow-angle astrometry using long-baseline IR (2.2 micron) stellar interferometers are very promising. With the excellent seeing at a high altitude site like Mauna Kea, the atmospheric limit for a 1 h astrometric measurement is expected to be of the order of 10 microarcsec for 1 h of integration. This two-order-of-magnitude improvement over conventional measurements is due to two effects. One is that a long-baseline IR interferometer can find useful reference stars very near an arbitrary target star, so that the atmospherically-induced motions of both stars are highly correlated. The second is that the baseline length can be much larger than the separation of the stellar beams in the turbulent atmosphere, resulting in a reduction in astrometric error with increasing baseline length.

Shao, M.↗

High-Precision Narrow Angle Astrometry with a Space-Borne Interferometer

This paper develops an observing and processing scheme for narrow angle astrometry using a single baseline interferometer without the aid of "grid" stars to characterize the interferometer baseline vector in inertial space. The basic concept derives from the recognition that over a narrow field the set of fundamental unknown instrument parameters that arise because the interferometer baseline vector has large uncertainties (since there are no grid star measurements) is indistinguishable from a particular set of unobservable errors in the determination of star positions within the field. Reference stars within the narrow field of regard are used to circumvent the unobservable modes. Feasibility of the approach is demonstrated through analysis and example simulations.

astrometry↗

A New Approach to Micro-arcsecond Astrometry with SIM Allowing Early Mission Narrow Angle Measurements of Compelling Astronomical Targets

The Space Interferometry Mission (SIM) is capable of detecting and measuring the mass of terrestrial planets around stars other than our own. It can measure the mass of black holes and the visual orbits of radio and x-ray binary sources. SIM makes possible a new level of understanding of complex astrophysical processes. SIM achieves its high precision in the so-called narrow-angle regime. This is defined by a 1 degree diameter field in which the position of a target star is measured with respect to a set of reference stars. The observation is performed in two parts: first, SIM observes a grid of stars that spans the full sky. After a few years, repeated observations of the grid allow one to determine the orientation of the interferometer baseline. Second, throughout the mission, SIM periodically observes in the narrow-angle mode. Every narrow-angle observation is linked to the grid to determine the precise attitude and length of the baseline. The narrow angle process demands patience. It is not until five years after launch that SIM achieves its ultimate accuracy of 1 microarcsecond. The accuracy is degraded by a factor of approx. 2 at mid-mission. Our work proposes a technique for narrow angle astrometry that does not rely on the measurement of grid stars. This technique, called Gridless Narrow Angle Astrometry (GNAA) can obtain microarcsecond accuracy and can detect extra-solar planets and other exciting objects with a few days of observation. It can be applied as early as during the first six months of in-orbit calibration (IOC). The motivations for doing this are strong. First, and obviously, it is an insurance policy against a catastrophic mid-mission failure. Second, at the start of the mission, with several space-based interferometers in the planning or implementation phase, NASA will be eager to capture the public's imagination with interferometric science. Third, early results and a technique that can duplicate those results throughout the mission will give the analysts important experience in the proper use and calibration of SIM.

Shaklan, Stuart↗

Baseline Monitoring for Astrometry in Interferometry

One of the science goals of NASA's Navigator program is ground-based narrow-angle astrometry for extra-solar planet detection, which could be done as part of the proposed Outrigger Telescopes Project. The narrow-angle measurement process, which would use the outrigger telescopes, starts with the determination of the conventional interferometer astrometric baseline, determined from wide-angle astrometry of Hipparcos stars. A baseline monitor system would be employed at each outrigger telescope. This system monitors the pivot point of each telescope - the end point of the astrometric baseline - to measure telescope imperfections that would cause the baseline to vary with telescope rotation. The baseline monitor includes azimuth and elevation cameras that monitor runout along the azimuth and elevation axes of the telescopes. In conjunction with the baseline monitor system, a pivot monitor camera in the dual-star module is used to register the laser metrology corner-cube reflector to the telescope pivot, tying the narrow-angle baseline, which applies to the narrow-angle astrometric measurement, to the wide-angle baseline. In this paper we present the proposed designs for the baseline monitor and pivot-point camera.

pivot point↗

Indirect Planet Detection with Ground-Based Interferometry

Narrow-angle astrometry with long-baseline infrared interferometers can provide extremely high accuracies as required for indirect planet detection. Narrow-angle asrometric interferometry exploits the properties of atmospheric turbulence over fields smaller than the interferometer baseline divided by the atmospheric scale height.

Interferometry Narrow-angle astrometry↗

Indirect planet detection with ground-based long-baseline interferometry

Narrow-angle astrometry with long-baseline infrared interferometers can provide extremely high accuracies as required for indirect planet detection. Narrow-angle astrometric interferometry exploits the properties of atmospheric turbulence over fields smaller than the interferometer baseline divided by the atmospheric scale height. For such fields, accuracy is linear with star separation, and nearly inversely proportional to baseline length. To exploit these properties, the interferometer observes a relatively bright (less than 13 mag(sub K)) target in the near infrared at 2.2 micrometers, and uses phase referencing to find a reference star within the 2.2-micrometers isoplanatic patch. With this technique faint references can be found for most targets. With baselines greater than 100 m, which also minimize photon-noise errors, and with careful control of systematic errors by using laser metrology, accuracies of tens of microarcseconds/square root of (hour) should be possible.

Colavita, M. M.↗

High-precision early mission narrow angle sciene with the Space Interferometry Mission

We have developed a technique that allows SIM to measure relative stellar positions with an accuracy of 1 micro-arcsecond at any time during its 5-yr mission. Unlike SIM's standard narrow-angle approach, Gridless Narrow Angle Astrometry (GNAA) does not rely on the global reference frame of grid stars that reaches full accuracy after 5 years. GNAA is simply the application of traditional single-telescope narrow angle techniques to SIM's narrow angle optical path delay measurements. In GNAA, a set of reference stars and a target star are observed at several baseline orientations. A linearized model uses delay measurements to solve for star positions and baseline orientations. A conformal transformation maps observations at different epochs to a common reference frame. The technique works on short period signals (P=days to months), allowing it to be applied to many of the known extra-solar planets, intriguing radio/X- ray binaries, and other periodic sources. The technique's accuracy is limited in the long-term by false acceleration due to a combination of reference star and target star proper motion. The science capability 1 micro-arcsecond astrometric precision - is unique to SIM.

Space Interferometry Mission↗

The Palomar Testbed Interferometer

The Palomar Testbed Interferometer (PTI) is a long-baseline infrared interferometer located at Palomar Observatory, California. It was built as a testbed for interferometric techniques applicable to the Keck Interferometer. First fringes were obtained in 1995 July. PTI implements a dual-star architecture, tracking two stars simultaneously for phase referencing and narrow-angle astrometry. The three fixed 40 cm apertures can be combined pairwise to provide baselines to 110 m. The interferometer actively tracks the white-light fringe using an array detector at 2.2 microns and active delay lines with a range of +/-38 m. Laser metrology of the delay lines allows for servo control, and laser metrology of the complete optical path enables narrow-angle astrometric measurements. The instrument is highly automated, using a multiprocessing computer system for instrument control and sequencing.

Colavita, M. M.↗

Global astrometry with the space interferometry mission

The prospects for global astrometric measurements with the space interferometry mission (SIM) are discussed. The SIM mission will perform four microarcsec astrometric measurements on objects as faint as 20 mag using the optical interferometry technique with a 10 m baseline. The SIM satellite will perform narrow angle astrometry and global astrometry by means of an astrometric grid. The sensitivities of the SIM global astrometric performance and the grid accuracy versus instrumental parameters and sky coverage schemes are reported on. The problems in finding suitable astrometric grid objects to support microarcsec astrometry, and related ground-based observation programs are discussed.

Boden, A.↗

Error Modeling of Multibaseline Optical Truss: Part 1: Modeling of System Level Performance

Global astrometry is the measurement of stellar positions and motions. These are typically characterized by five parameters, including two position parameters, two proper motion parameters, and parallax. The Space Interferometry Mission (SIM) will derive these parameters for a grid of approximately 1300 stars covering the celestial sphere to an accuracy of approximately 4uas, representing a two orders of magnitude improvement over the most precise current star catalogues. Narrow angle astrometry will be performed to a 1uas accuracy. A wealth of scientific information will be obtained from these accurate measurements encompassing many aspects of both galactic (and extragalactic science. SIM will be subject to a number of instrument errors that can potentially degrade performance. Many of these errors are systematic in that they are relatively static and repeatable with respect to the time frame and direction of the observation. This paper and its companion define the modeling of the, contributing factors to these errors and the analysis of how they impact SIM's ability to perform astrometric science.

meterology modeling↗

Recent Results of the Guide-2 Telescope Testbed for the SIM-Lite Mission

The Space Interferometry Mission Planet QuestLite (SIM-Lite) is a new mission concept to perform microarcsecond narrow-angle astrometry to search approximately 50 nearby stars for Earth-like planets, and also to perform a global astrometry. The SIM-Lite consists of two Michelson interferometers and one telescope. The main six-meter baseline science interferometer observes a target star and a set of reference stars. The four-meter baseline interferometer (Guide-1) monitors the attitude of the instrument in the direction of a target star. A new Guide-2telescope (G2T) tracks a bright star to monitor the attitude of the instrument in the other two orthogonal directions. In the current mission concept, the G2T consists of a 30 cm siderostat and a 30 cm confocal telescope, similar to other four telescopes used in the science and Guide-1interferometers. A testbed has been built to demonstrate the G2T feasibility for SIM-Lite mission. Recent results show that field-independent, star-tracking capability of the system is less than 30 (mu)as after the SIM narrow angle analysis.

Guide-2 Telescope↗

Overview of SIM wide angle astrometric system calibration strategies

This paper summarizes two very different strategies envisioned for calibrating the systematic field dependent biases present in the Space Interferometry Mission (SIM) instrument. The Internal Calibration strategy is based on pre-launch measurements combined with a set of on orbit measurements generated by a source internal to the instrument. The External Calibration strategy uses stars as an external source for generating the calibration function. Both approaches demand a significant amount of innovation given that SIM's calibration strategy requires a post-calibration error of 100picometers over a 15 degree field of regard while the uncalibrated instrument introduces 10's-100's of nanometers of error. The calibration strategies are discussed in the context of the Wide Angle Astrometric mode of the instrument, although variations on the Internal Calibration Strategy may be used for doing Narrow Angle Astrometry.

calibration SIM optical modeling↗

ASEPS-0 Testbed Interferometer

The ASEPS-0 Testbed Interferometer is a long-baseline infrared interferometer optimized for high-accuracy narrow-angle astrometry.

detector↗

Search for Terrestrial Planets with SIM Planet Quest

SIM is an astrometric mission that will be capable of 1 microarcsec relative astrometric accuracy in a single measurement of approx.1000 sec. The search for terrestrial planets in the habitable zone around nearby stars is one of the main science goals of the project. In 2001, NASA through the peer review process selected 10 key projects, two of which had as its goal, the search for terrestrial planets around nearby stars. The two teams, one led by G. Marcy (UC Berkeley) and one lead by M. Shao (JPL), have an extensive preparatory science program underway. This paper describes the status of this activity as well as the technology status of SIM's narrow angle astrometry capability, to reach 1 uas in a single epoch measure and its ability to average multiple epoch measurements to well below 1 uas.

extrasolar planets↗

Recent Status of SIM Lite Astrometric Observatory Mission: Flight Engineering Risk Reduction Activities

The SIM Lite Astrometric Observatory is a mission concept for a space-borne instrument to perform micro-arc-second narrow-angle astrometry to search 60 to 100 nearby stars for Earth-like planets, and to perform global astrometry for a broad astrophysics program. The instrument consists of two Michelson stellar interferometers and a telescope. The first interferometer chops between the target star and a set of reference stars. The second interferometer monitors the attitude of the instrument in the direction of the target star. The telescope monitors the attitude of the instrument in the other two directions. The main enabling technology development for the mission was completed during phases A & B. The project is currently implementing the developed technology onto flight-ready engineering models. These key engineering tasks will significantly reduce the implementation risks during the flight phases C & D of the mission. The main optical interferometer components, including the astrometric beam combiner, the fine steering optical mechanism, the path-length-control and modulation optical mechanisms, focal-plane camera electronics and cooling heat pipe, are currently under development. Main assemblies are built to meet flight requirements and will be subjected to flight qualification level environmental testing (random vibration and thermal cycling) and performance testing. This paper summarizes recent progress in engineering risk reduction activities.

astrometry↗