At least 19 records

Solar Decathlon Visitors Guide 2011, National Mall, West Potomac Park, Washington, D.C., September 23 - October 2, 2011 (Brochure)

Guide to the student-designed houses, ten contests, exhibits, and workshops of the U.S. Department of Energy 2011 Solar Decathlon, held in Washington, D.C., from September 23 through October 2, 2011. Teams of college students designed and built the solar-powered houses on display here. They represent 13 U.S. states, five countries, and four continents. Now the teams are rising to the challenge by competing in 10 contests over nine days, with the championship trophy on the line. This is their time to shine. The 2011 teams may share a common goal - to design and build the best energy-efficient house powered by the sun - but their strategies are different. One house is made of precast concrete, while another 'dances' in response to its environment. Another house is meant to sit atop a building, proving the sky's the limit for energy innovation. Whatever your idea of sustainable living may be, you are bound to find it at the Solar Decathlon.

14 SOLAR ENERGY↗

Clean Technology Evaluation & Workforce Development Program

The overall objective of the Clean Technology Evaluation portion of the award was to design a process to speed up the identification of new clean energy technologies and match organizations to testing and early adoption partners. The project was successful in identifying new technologies targeted to utilities and utility technology integrators, in developing a process to review and rank the new technologies, and in facilitating new partnerships for technology testing and adoption. The purpose of the Workforce Development portion of the award was to create an education outreach program for middle & high-school students focused on clean technology science and engineering. While originally targeting San Diego, California and Cambridge, Massachusetts, the scope of the program was expanded to include a major clean technology speaking series and expo as part of the USA Science & Engineering Festival on the National Mall in Washington, D.C.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

2018 Wood Stove Design Challenge (Final Report)

The Alliance for Green Heat hosted the 2018 Wood Stove Design Challenge on the National Mall in Washington DC from Friday, Nov. 9 – Tuesday, November 13. The Design Challenge is a technology competition designed to foster R&D of innovative, next generation wood and pellet stove designs. In 2018, the Challenge focused on two technology goals: automating the wood stove and making electricity from wood or pellet stoves.

09 BIOMASS FUELS↗

Results of the 2018 Wood Stove Design Challenge

The 2018 Wood Stove Design Challenge was an international design competition which sought to identify top performing residential wood stoves based on automation. To prepare for the event, the Northeast States for Coordinated Air Use Management (NESCAUM) developed a testing protocol that challenged the stoves by testing them in more field-like conditions—capturing emissions from start-up, reloading a stove, and the use of larger piece sizes. Flue gas emissions were measured using a combination of in-stack and novel dilution sampling methods, as the event occurred on the National Mall in Washington D.C. in a non-laboratory setting. Particulate matter (PM), carbon monoxide (CO), carbon dioxide (CO2), and methane (CH4) were measured from three stoves in real-time. A combustion efficiency was also calculated for each stove in real-time. Measured PM emission rates ranged between 1.8 and 8.0 g/hr for all stoves and operating conditions, with the highest emissions being measured during cold start in all cases. The test average PM emission rates were 2.4, 4.0, and 2.4 g/hr for stoves A, B, and C, respectively. Results showed emissions measured during transient operations, which are often excluded in current certification methods, can be significantly higher than steady-state periods—echoing other studies and highlighting the importance of testing in various operational modes for more realistic emission estimates. Additionally, the stoves had overall CO emission rates of 48.8, 284.8, and 100.8 g/hr, for stoves A, B and C, respectively. Calculated PM and CO emission factors overall were low considering the testing protocol sought to follow more challenging yet realistic practices in terms of fuel loading and operating procedures. The overall estimated combustion efficiency for stoves A, B, and C was 85%, 78%, 76%, respectively and in all cases was lowest during the cold start period.This report details the successfully proposed and assembled instrumentation that was relatively portable for field-site testing and the results of the emissions measurements for the 2018 Wood Stove Design Challenge competition. Overall, the repeatability of each stove was favorable with coefficients of variation (COV) ranging from 7 to 15% for measured PM concentrations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Clean Cities Now Vol. 17, No. 2

The Fall 2013 issue of the biannual newsletter for the U.S. Department of Energy's Clean Cities initiative. The newsletter includes feature stories on deployment of alternative fuels and advanced vehicles, and articles on Clean Cities coalition successes across the country.

20th Anniversary↗

Solar Decathlon 2011, (Small Program)(Brochure)

This brochure provides a high-level overview of the U.S. Department of Energy Solar Decathlon 2011. The competition's background, purpose, impact, 10 contests, 20 teams, and where to go for additional information.

14 SOLAR ENERGY↗

Unraveling emission line galaxy conformity at z ∼ 1 with DESI early data

Emission line galaxies (ELGs) are now the preeminent tracers of large-scale structure at z > 0.8 due to their high density and strong emission lines, which enable accurate redshift measurements. However, relatively little is known about ELG evolution and the ELG–halo connection, exposing us to potential modelling systematics in cosmology inference using these sources. In this paper, we use a variety of observations and simulated galaxy models to propose a physical picture of ELGs and improve ELG–halo connection modelling in a halo occupation distribution framework. We investigate Dark Energy Spectroscopic Instrument (DESI)-selected ELGs in COSMOS data, and infer that ELGs are rapidly star-forming galaxies with a large fraction exhibiting disturbed morphology, implying that many of them are likely to be merger-driven starbursts. We further postulate that the tidal interactions from mergers lead to correlated star formation in central–satellite ELG pairs, a phenomenon dubbed ‘conformity’. We argue for the need to include conformity in the ELG–halo connection using galaxy models such as IllustrisTNG, and by combining observations such as the DESI ELG autocorrelation, ELG cross-correlation with luminous red galaxies, and ELG–cluster cross-correlation. We also explore the origin of conformity using the UniverseMachine model and elucidate the difference between conformity and the well-known galaxy assembly bias effect.

79 ASTRONOMY AND ASTROPHYSICS↗

Biasing from galaxy trough and peak profiles with the DES Y3 redMaGiC galaxies and the weak lensing mass map

We measure the correspondence between the distribution of galaxies and matter around troughs and peaks in the projected galaxy density, by comparing redMaGiC galaxies (0.15 < z < 0.65) to weak lensing mass maps from the Dark Energy Survey (DES) Y3 data release. We obtain stacked profiles, as a function of angle θ, of the galaxy density contrast δ g and the weak lensing convergence κ, in the vicinity of these identified troughs and peaks, referred to as ‘void’ and ‘cluster’ superstructures. The ratio of the profiles depend mildly on θ, indicating good consistency between the profile shapes. We model the amplitude of this ratio using a function $F(\boldsymbol{\eta }, \theta )$ that depends on cosmological parameters $\boldsymbol{\eta }$, scaled by the galaxy bias. We construct templates of $F(\boldsymbol{\eta }, \theta )$ using a suite of N-body (‘Gower Street’) simulations forward-modelled with DES Y3-like noise and systematics. We discuss and quantify the caveats of using a linear bias model to create galaxy maps from the simulation dark matter shells. We measure the galaxy bias in three lens tomographic bins (near to far): $2.32^{+0.86}_{-0.27}, 2.18^{+0.86}_{-0.23}, 1.86^{+0.82}_{-0.23}$ for voids, and $2.46^{+0.73}_{-0.27}, 3.55^{+0.96}_{-0.55}, 4.27^{+0.36}_{-1.14}$ for clusters, assuming the best-fit Planck cosmology. Similar values with ∼0.1σ shifts are obtained assuming the mean DES Y3 cosmology. The biases from troughs and peaks are broadly consistent, although a larger bias is derived for peaks, which is also larger than those measured from the DES Y3 3 × 2-point analysis. This method shows an interesting avenue for measuring field-level bias that can be applied to future lensing surveys.

cosmology: observations↗

Post-occupancy evaluation of indoor environmental quality in ten nonresidential buildings in Chongqing, China

Indoor environmental quality (IEQ) is an essential element of sustainable building performance. To advance knowledge of indoor environmental quality in Chinese nonresidential buildings, this study conducted post-occupancy evaluation (POE) in varied use areas within schools, hospitals, offices, hotels and shopping malls through environmental measurements and occupant surveys in 10 buildings over four seasons in Chongqing, China. Measured thermal conditions were more frequently within comfort standards in winter than in summer according to the predicted mean vote – predicted percentage dissatisfied model; but the model did not reliably predict thermal satisfaction. There was insufficient illuminance in 28% of studied areas and high illuminance in shopping malls led to complaints about glare. Sound pressure exceeded the Chinese guideline in all buildings with shopping malls having significantly higher levels than other buildings. CO 2 was generally below the Chinese national guideline of 1000 ppm; the two percent of measurements that exceeded the guideline occurred in classrooms, hospital wards and underground supermarkets. Formaldehyde did not exceed the limit level of 0.1 mg/m3 in any space. Most of the buildings did not provide effective protection from outdoor fine particulate matter (PM2.5), and infiltration from outdoors was the main factor for exceeding health-based guidelines indoors. Shopping malls had lower IEQ satisfaction than offices, schools and hospitals. Sound was the factor with the lowest satisfaction level among the four principal environmental factors. Overall, this study demonstrates value of POE on identifying deficiencies in indoor environment and provides a reference for assessment of IEQ in nonresidential buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Imaging Photonic Resonances within an All‐Dielectric Metasurface via Photoelectron Emission Microscopy

Dielectric metasurfaces, through volume‐type photonic resonances, enable precise control of light‐matter interactions for applications including imaging, holography, and sensing. The application space of dielectric metasurfaces has extended from infrared to visible wavelengths by incorporating high refractive index materials, such as titanium dioxide (TiO 2 ). Understanding the fundamental and fabrication limits for these applications requires metrology with nanoscale resolution, sensitivity to electromagnetic fields within the meta‐atom volume, and far‐field excitation. In this work, photoelectron emission microscopy (PEEM) is used to image field distributions of photonic resonances in a TiO 2 metasurface excited with far‐field, visible‐wavelength illumination. The local volumetric field variations within the meta‐atoms are analyzed as a function of illumination angle and polarization by comparing photoelectron images to finite‐difference time‐domain simulations. This study determines the inelastic mean free path of very low‐energy (<1 eV) photoelectrons to be 35 ± 10 nm, which is comparable to the meta‐atom height thereby highlighting PEEM sensitivity to resonances within the volume. Additionally, the simulations reveal high sensitivity of PEEM images to an in‐plane component of the illumination k ‐vector. These results demonstrate that photoelectron imaging with subwavelength resolution offers unique advantages for examining light‐matter interactions in volume‐type (as opposed to surface) photonic modes within dielectric nanophotonic structures.

electron inelastic mean free path↗

Dark Energy Survey Year 6 results: cell-based coadds and METADETECTION weak lensing shape catalogue

We present the metadetection weak lensing galaxy shape catalogue from the 6-yr Dark Energy Survey (DES Y6) imaging data. This data set is the final release from DES, spanning 4422 deg 2 of the southern sky. We describe how the catalogue was constructed, including the two new major processing steps, cell-based image coaddition, and shear measurements with metadetection. The DES Y6 M etadetection weak lensing shape catalogue consists of 151 922 791 galaxies detected over riz bands, with an effective number density of n eff = 8.22 galaxies per arcmin 2 and shape noise of σ e = 0.29. We carry out a suite of validation tests on the catalogue, including testing for point spread function (PSF) leakage, testing for the impact of PSF modelling errors, and testing the correlation of the shear measurements with galaxy, PSF, and survey properties. In addition to demonstrating that our catalogue is robust for weak lensing science, we use the DES Y6 image simulation suite to estimate the overall multiplicative shear bias of our shear measurement pipeline. We find no detectable multiplicative bias at the roughly half-per cent level, with m = (3.4 ± 6.1) x 10 –3 , at 3σ uncertainty. This is the first time both cell-based coaddition and Metadetection algorithms are applied to observational data, paving the way to the Stage-IV weak lensing surveys.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

America Saves! Energizing Main Street's Small Businesses

The America Saves! Energizing Main Street Small Businesses project engaged the 1,200-member National Main Street Center (NMSC) network of downtown organizations and other local, regional, and national partners to test a methodology for sharing customized energy efficiency information with owners of commercial buildings smaller than 50,000 square feet. Led by the National Trust for Historic Preservation’s Preservation Green Lab, the project marshalled local staff and volunteers to gather voluntarily-disclosed energy use information from participating businesses. This information was analyzed using a remote auditing tool (validated by the National Renewable Energy Lab) to assess energy savings opportunities and design retrofit strategies targeting seven building types (food service and sales, attached mixed-use, strip mall, retail, office, lodging, and schools). The original project design contemplated extensive leveraging of the Green Button protocol for sharing annualized utility data at a district scale. Due the lack of adoption of Green Button, the project partners developed customized approaches to data collection in each of twelve pilot communities. The project team encountered considerable challenges in gathering standardized annual utility data from local partners. After overcoming these issues, the data was uploaded to a data storehouse. Over 450 properties were benchmarked and the remote auditing tool was tested using full building profiles and utility records for more than 100 commercial properties in three of the pilot communities. The audit tool demonstrated potential for quickly capturing, analyzing, and communicating energy efficiency opportunities in small commercial buildings. However, the project team found that the unique physical characteristics and use patterns (partial vacancy, periodic intensive uses) of small commercial buildings required more trouble-shooting and data correction than was anticipated. In addition, the project revealed that remote technology alone (such as audits) is not sufficient to convince most owners of commercial buildings or businesses to invest in energy efficiency. Additional, one-on-one personal communication is critical. A combination of technology and well-planned direct contact is likely to produce the highest rate of energy efficiency implementation in the small commercial building market sector. Note that only two of the three planned phases of this project were completed. As a result, research and testing were not fully implemented and thus all results and conclusions from the America Saves! Energizing Main Street Small Businesses project should be considered preliminary. In addition to the National Main Street Center, local organizations, and regional utilities, the America Saves! project partners included the National Renewable Energy Laboratory, Energy Center of Wisconsin (Seventh Wave), Lend Lease, Building Energy, and Energy RM.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

OpenUniverse2024: a shared, simulated view of the sky for the next generation of cosmological surveys

The OpenUniverse2024 simulation suite is a cross-collaboration effort to produce matched simulated imaging for multiple surveys as they would observe a common simulated sky. Both the simulated data and associated tools used to produce it are intended to uniquely enable a wide range of studies to maximize the science potential of the next generation of cosmological surveys. We have produced simulated imaging for approximately 70 deg 2 of the Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST) Wide-Fast-Deep survey and the Nancy Grace Roman Space Telescope High-Latitude Wide-Area Survey, as well as overlapping versions of the ELAIS-S1 Deep-Drilling Field for LSST and the High-Latitude Time-Domain Survey for Roman. OpenUniverse2024 includes (i) an early version of the updated extragalactic model called Diffsky, which substantially improves the realism of optical and infrared photometry of objects, compared to previous versions of these models; (ii) updated transient models that extend through the wavelength range probed by Roman and Rubin; and (iii) improved survey, telescope, and instrument realism based on up-to-date survey plans and known properties of the instruments. It is built on a new and updated suite of simulation tools that improves the ease of consistently simulating multiple observatories viewing the same sky. The approximately 400 TB of synthetic survey imaging and simulated universe catalogs are publicly available, and we preview some scientific uses of the simulations.

large-scale structure of Universe↗

Oak Ridge National Laboratory Wireless Charging of Electric Vehicles - CRADA Report

Wireless power transfer (WPT) is a paradigm shift in electric-vehicle (EV) charging that offers the consumer an autonomous, safe, and convenient option to conductive charging and its attendant need for cables. With WPT, charging process can be fully automated due to the vehicle and grid side radio communication systems, and is non-contacting; therefore issues with leakage currents, ground faults, and touch potentials do not exist. It also eliminates the need for touching the heavy, bulky, dirty cables and plugs. It eliminates the fear of forgetting to plug-in and running out of charge the following day and eliminates the tripping hazards in public parking lots and in highly populated areas such as shopping malls, recreational areas, parking buildings, etc. Furthermore, the high-frequency magnetic fields employed in power transfer across a large air gap are focused and shielded, so that fringe fields (i.e., magnetic leakage/stray fields) attenuate rapidly over a transition region to levels well below limits set by international standards for the public zone (which starts at the perimeter of the vehicle and includes the passenger cabin). Oak Ridge National Laboratory s approach to WPT charging places strong emphasis on radio communications in the power regulation feedback channel augmented with software control algorithms. The over-arching goal for WPT is minimization of vehicle on-board complexity by keeping the secondary side content confined to coil tuning, rectification, filtering, and interfacing to the regenerative energy-storage system (RESS). This report summarizes the CRADA work between the Oak Ridge National Laboratory and the Toyota Research Institute of North America, Toyota Motor Engineering and Manufacturing North America (TEMA) on the wireless charging of electric vehicles which was funded by Department of Energy under DE-FOA-000667. In this project, ORNL is the lead agency and Toyota TEMA is one of the major partners. Over the course of the project, ORNL and Toyota TEMA worked closely on the vehicle integration plans, compatibility, and the interoperability of the wireless charging technology developed by ORNL for the vehicles manufactured by Toyota. These vehicles include a Toyota Prius Plug-in Hybrid electric vehicle, a Scion iQ electric vehicle, and two Toyota RAV4 electric vehicles. The research include not only the hardware integration but also the controls and communication systems development to control and automate the charging process for these vehicles by utilizing a feedback channel from vehicle to the stationary unit for power regulation.

33 ADVANCED PROPULSION SYSTEMS↗

Regency Centers Develops Leadership in Energy-Efficient Renovations

Regency Centers (Regency) partnered with the Department of Energy (DOE) to develop and implement solutions to retrofit existing buildings to reduce energy consumption by at least 30% versus requirements set by Standard 90.1-2004 of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), the American National Standards Institute (ANSI), and the Illuminating Engineering Society of North America (IESNA) as part of DOE’s Commercial Building Partnerships (CBP) Program.

EEMs↗

Urban Traveler - Changes and Impacts: Mobility Energy Productivity (MEP) Metric

For nearly a century, the automobile has been the primary mode of personal transportation in American life. This remains true today as millions of people rely heavily on cars to connect suburbs with cities or to travel long distances—often out of routine or convenience. However, advances in technology are fueling an era of transportation transformation, with the potential to transform a system that has remained virtually unchanged for decades. Aspiring smart cities are wrestling with questions such as: How does mobility impact a person’s quality of life? Would people make different travel choices if they were presented with better information about their mobility options? The ability to quantify the mobility potential of a given location is the first step toward answering these questions. In response, an interdisciplinary team at the National Renewable Energy Laboratory (NREL) has developed the Mobility-Energy Productivity (MEP) metric. The MEP metric provides an avenue to not only measure the mobility potential at a specific location in its current configuration, but also to test how various technological advances (e.g., connected and automated vehicles, plug-in electric vehicles, shared mobility) and infrastructure investments (e.g., building an additional highway lane, constructing a new shopping mall, implementing a transit-oriented development) impact the mobility of that location over time. This presentation details the FY19 progress on the MEP metric project funded through DOE VTO's SMART Mobility Consortium.

47 OTHER INSTRUMENTATION↗

Measuring Mobility Potential: A Novel Metric to Quantify Mobility Energy Productivity (MEP) of Transportation Systems

For nearly a century, the automobile has been the primary mode of personal transportation in American life. This remains true today as millions of people rely heavily on cars to connect suburbs with cities or to travel long distances - often out of routine or convenience. However, advances in technology are fueling an era of transportation transformation, with the potential to transform a system that has remained virtually unchanged for decades. The challenges of interconnecting our cities and creating a cross-continental transportation system for military purposes spawned the interstate highway system, generating the age of the automobile. In this century, congestion and mobility challenges of rising urban populations are spawning ever-evolving mobility and communications technologies to connect people to goods, services, and employment within a metropolitan and national context - all of which define a high quality of life. Aspiring smart cities are wrestling with questions such as: How does mobility impact a person's quality of life? Would people make different travel choices if they were presented with better information about their mobility options? Would businesses make different location decisions if they could assess the quality of mobility in that area? The ability to quantify the quality of mobility at a given location is the first step toward answering these questions. In response, an interdisciplinary team at the National Renewable Energy Laboratory (NREL) has developed the Mobility-Energy Productivity (MEP) metric. The MEP metric provides an avenue to not only measure the quality of mobility at a specific location in its current configuration, but also to test how various technological advances (e.g., connected and automated vehicles, plug-in electric vehicles, shared mobility) and infrastructure investments (e.g., building an additional highway lane, constructing a new shopping mall, implementing a transit-oriented development) impact the mobility of that location over time.

30 DIRECT ENERGY CONVERSION↗

First Results from the Washington D.C. Metropolitan Area Lighting Map Demonstration Project

An experimental portable lightning mapping array (LMA) operating in the upper VHF TV band (Channels 7-13; 174-216 MHz) was deployed in the Washington DC Metropolitan area during the summer 2006 to locate and monitor the overall lightning activity. The LMA network provides total lightning data to support lightning research as well as proxy data to benefit the development of applications for planned observing systems such as the GOES-R Geostationary Lightning Mapper. The portable LMA hardware is a compactly-housed, easily deployed version of the LMA stations installed North Alabama, Oklahoma, and New Mexico, which operate in the lower VHF TV band (Channels 2-6,54-88 MHz). Real-time LMA data products are provided to the National Weather Service Weather Forecast Office (WFO) in Sterling, VA to aid in their forecast and warning operations. Forecasters at WFO Sterling have already found the lightning data from the Washington DC demonstration network to be very useful in assessing the development of storm systems. On July 4,2006, data from the LMA aided forecasters as they monitored an area of convection that later developed into a line of severe storms that moved southward through the Washington DC metropolitan area across the Washington Mall. Additional applications of lightning mapping data in the Baltimore-Washington DC urban environment will be discussed.

Goodman, Steven J.↗