Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Neutron multiplicity ,easurements With 3 He alternative: Straw neutron detectors

Counting neutrons emitted by special nuclear material (SNM) and differentiating them from the background neutrons of various origins is the most effective passive means of detecting SNM. Unfortunately, neutron detection, counting, and partitioning in a maritime environment are complex due to the presence of high-multiplicity spallation neutrons (commonly known as “ship effect”) and to the complicated nature of the neutron scattering in that environment. In this study, a prototype neutron detector was built using 10 B as the converter in a special form factor called “straws” that would address the above problems by looking into the details of multiplicity distributions of neutrons originating from a fissioning source. This paper describes the straw neutron multiplicity counter (NMC) and assesses the performance with those of a commercially available fission meter. The prototype straw neutron detector provides a large-area, efficient, lightweight, more granular (than fission meter) neutron-responsive detection surface (to facilitate imaging) to enhance the ease of application of fission meters. Presented here are the results of preliminary investigations, modeling, and engineering considerations leading to the construction of this prototype. This design is capable of multiplicity and Feynman variance measurements. This prototype may lead to a near-term solution to the crisis that has arisen from the global scarcity of 3 He by offering a viable alternative to fission meters. This paper describes the work performed during a 2-year site-directed research and development (SDRD) project that incorporated straw detectors for neutron multiplicity counting. The NMC is a two-panel detector system. We used 10 B (in the form of enriched boron carbide: 10 B 4 C) for neutron detection instead of 3 He. In the first year, the project worked with a panel of straw neutron detectors, investigated its characteristics, and developed a data acquisition (DAQ) system to collect neutron multiplicity information from spontaneous fission sources using a single panel consisting of 60 straws equally distributed over three rows in high-density polyethylene moderator. In the following year, we developed the field-programmable gate array and associated DAQ software. Finally, this SDRD effort successfully produced a prototype NMC with ~33% detection efficiency compared to a commercial fission meter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The development of a 6 Li-based pixelated neutron detector for neutron reflectometry at the Spallation Neutron Source

We present a high-rate 6 Li-based pixelated neutron detector developed for neutron reflectometry instruments at the Spallation Neutron Source (SNS). The neutron detector has a pixelated design: each 6 Li scintillator element has its own photosensor and independent channel readout. This paper focuses on the general overview of the detector design and construction, the characterization of the pixelated detector, and the results of the first neutron reflectivity experiments conducted using the pixelated neutron detector at the SNS Liquid Reflectometer (BL-4B). The pixelated neutron detector demonstrated a global time-average count rate of ≥ 1.8 x 10 6 cps, at least 3 orders of magnitude higher than that of the existing neutron detector ( 3 He-based Multi-Wire Proportional Counter), and a local instantaneous count rate of ≥ 1.73 x 10 6 cps / cm 2 . The maximum counting rate of the detector has not yet been determined as the detector is capable of handling the maximum flux available at the beamline. Furthermore, the outcome of the neutron reflectivity experiments showed that the pixelated neutron detector is a promising candidate for next-generation neutron reflectometry instruments at the SNS.

6Li, silicon photomultiplier↗

Applications of {sup 3}He neutron detectors

Neutron detectors with {sup 3}He-filled proportional counters are described. The use of these detectors in measuring the probability of neutron emission (in particular, multiparticle neutron emission) after the {beta} decay of neutron-rich nuclei and in studying rare events of spontaneous fission of superheavy nuclei is considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Apparatus for use in a directional-neutron detector, directional-neutron detectors and methods of use thereof

An apparatus for used in a directional-neutron detector is disclosed. The apparatus comprises a structure having a plurality of parallel active channels separated by inactive regions. The plurality of active channels is filled with scintillating material. The scintillating material is configured to emit light in response to neutron scattering. The scintillating material may be neutron-gamma discriminating. The scintillating material may be sealed in the plurality of active channels. The seal is disposed on respective ends of the plurality of active channels. Directional-neutron detectors are also disclosed having the structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Used Fuel Storage Monitoring Using Helium-4 Scintillation Fast Neutron Detectors and Neutron Spectral Analysis

This project aimed to address the technology gap in the reliable methods to verify contents of sealed dry storage casks for spent nuclear fuel. Helium-4 gas scintillation neutron detectors was proposed to be developed into a neutron spectroscopy and imaging system for nuclear security and safeguards applications. 4 He gas is significantly more available than 3 He gas and it has unique advantages such as low gamma interaction probability and direct detection of fast neutrons. Due to the sheer amount of fissile materials in a single dry cask, there is a significant neutron fluence emitted whose energies range from thermal to uncollided high-energy neutrons suitable for the detection capability of the 4 He detectors. Our project demonstrated the first ever neutron spectroscopic capabilities using 4 He detectors, explored novel detector design and performed detector characterization. It further qualified the detectors for use in various applications including high-flux environments with significant gamma-fluence. Computer simulations were used to test various large cask measurement system designs and tests, beyond the compact prototype system and laboratory measurements exploring the feasibility of the neutron spectroscopic approach. Although some cask-characterization methods proved unfeasible, alternative characterization methods using the He-4 detectors were explored and generated promising results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ab initio response functions for Cherenkov-based neutron detectors

Neutron time-of-flight diagnostics at the NIF were of late outfitted with Cherenkov detectors. A fused silica radiator delivers sub-nanosecond response time and is optically coupled to a microchannel plate photomultiplier tube with gain from ~1 to 10 4 . Capitalizing on fast time response and gamma-ray sensitivity, these systems can provide better than 30 ps precision for measuring first moments of neutron distributions. Generation of ab initio instrument response functions (IRFs) is critical to meet the <1% uncertainty needed. A combination of Monte Carlo modeling, benchtop characterization, and in situ comparison is employed. Close agreement is shown between the modeled IRFs and in situ measurements using the NIF’s short-pulse advanced radiographic capability beams. First and second moments of neutron spectra calculated using ab initio IRFs agree well with established scintillator measurements. Next-step designs offer increased sensitivity and time-response.

47 OTHER INSTRUMENTATION↗

ICONS: Solid-State Composite Neutron Detector

Neutron detection is essential for identifying and monitoring nuclear materials and nuclear reactions. Most deployed neutron-detection systems rely on helium-3 ( 3 He) gas-filled tubes, which have been the standard technology for decades.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Godiva IV central cavity neutron environment characterization with threshold neutron detectors

Godiva IV is a cylindrical fast burst reactor comprised of approximately 65 kg of highly enriched uranium that is operated by Los Alamos National Laboratory and sited at the National Criticality Experiments Research Center at the Nevada National Security Site in Nevada in the United States. Godiva IV is typically operated at delayed critical and in the regime spanning from sub-prompt to super-prompt bursts. Godiva IV is used for sample irradiations, criticality safety demonstrations, dosimetry studies, and for studying super-prompt behavior. In preparation for both an upcoming experiment to reduce uncertainties in the prompt fission spectrum for 235U using threshold neutron detectors, and for future research using Godiva IV, it was desired to exercise the process of the selection of threshold neutron detectors/activation foils, radiation metrology, and the subsequent adjustment of the neutron spectrum. For this exercise, nine high purity threshold neutron detectors/activation foils were irradiated in a Godiva IV burst. The foils were then analyzed using a high-purity germanium detector in the NCERC counting laboratory to determine end of irradiation specific activities for available IRDFF-II reactions. This work summarizes the Godiva IV foil irradiation, radiation metrology results, and adjusted neutron spectrum. The results of this exercise ultimately characterized the neutron environment inside the sample irradiation cavity inside Godiva IV to a higher degree than previously performed, informed decisions for the upcoming larger scale experiment, and will inform future neutron spectrum characterizations at NCERC.

Whitman, Nicholas H.↗

Analysis of the response of innovative neutron detectors with monoenergetic neutron beams

Various neutron detectors are currently under development at the University of Pisa. The response of these devices is investigated using monoenergetic neutron beams produced at the CN accelerator of INFN Legnaro National Laboratories with thin lithium target bombarded by protons at different energies, exploiting the {sup 7}Li(p,n){sup 7}Be reaction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Versatile Array of Neutron Detectors at Low Energy

The Versatile Array of Neutron Detectors at Low Energy (VANDLE) is a new array of plastic scintillator bars under development for measurements at the Holifield Radioactive Ion Beam Facility at Oak Ridge National Laboratory. The array is highly modular allowing the configuration of the individual elements to be optimized for particular experimental requirements, such as (d,n) and beta-delayed neutron-decay measurements with neutron-rich rare isotope beams.

43 PARTICLE ACCELERATORS↗

Semiconductor neutron detector

A neutron detector has a compound of lithium in a single crystal form as a neutron sensor element. The lithium compound, containing improved charge transport properties, is either lithium niobate or lithium tantalate. The sensor element is in direct contact with a monitor that detects an electric current. A signal proportional to the electric current is produced and is calibrated to indicate the neutrons sensed. The neutron detector is particularly useful for detecting neutrons in a radiation environment. Such radiation environment may, e.g. include gamma radiation and noise.

47 OTHER INSTRUMENTATION↗

Mutli-layered neutron detector

A neutron detector including a plurality of layers of converter material and a plurality of layers of detector material. Each layer of converter material can be immediately adjacent to at least one layer of detector material and each layer of detector material can be immediately adjacent to at least one layer of converter material. The neutron detector may further include a read out integrated circuit (ROIC) that is electrically coupled to the plurality of layers of detector material. A value output by the ROIC may be indicative of a neutron interacting with a layer of converter material from amongst the plurality of layers of converter material.

Rice, William Charles↗

Neutron detector

A neutron detector has a volume of neutron moderating material and a plurality of individual neutron sensing elements dispersed at selected locations throughout the moderator, and particularly arranged so that some of the detecting elements are closer to the surface of the moderator assembly and others are more deeply embedded. The arrangement captures some thermalized neutrons that might otherwise be scattered away from a single, centrally located detector element. Different geometrical arrangements may be used while preserving its fundamental characteristics. Different types of neutron sensing elements may be used, which may operate on any of a number of physical principles to perform the function of sensing a neutron, either by a capture or a scattering reaction, and converting that reaction to a detectable signal. High detection efficiency, an ability to acquire spectral information, and directional sensitivity may be obtained.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Report on the Tin-II Thermal Neutron Detector

Thermal neutrons have recently become a concern in the semiconductor community where it has been reported that approximately 20% of the single-event upsets are due to thermal neutrons in some devices. The goal of this project is to measure the intensity of thermal neutrons in the High- Performance Computing (HPC) area. This is part of a larger effort to characterize the radiation environment in the HPC area which includes high-energy neutrons as well as thermal neutrons. To accomplish this goal, we designed and fabricated a neutron detector that is sensitive to thermal neutrons called Tin-II. The Tin-II detector consists of two identical 3He ionization chambers with one detector bare and one detector shielded with cadmium. Because the cadmium shielding effectively blocks the thermal neutrons, the difference in count rates between these two detectors reflect the number of thermal neutrons detected. This report summarizes the status of our efforts to develop this detector.

47 OTHER INSTRUMENTATION↗

Elimination of ghosting artifacts from wavelength-shifting fiber neutron detectors

Misassignment of neutron position (ghosting) produces artifacts, which have been observed in wavelength-shifting (WLS) fiber detectors developed for time-of-flight (TOF) neutron powder diffraction. In position-sensitive detectors (PSDs) with WLS fiber encoding, thermal and cold neutrons interact with a monolithic 6LiF/ZnS:Ag scintillator screen, and scintillation photons are generated and transported through the crossed fibers to photomultipliers (PMTs). The neutron position is determined by photon counts in PMTs within a preset time window. Ghosting occurs when neutrons hit the group boundaries of two neighboring PMTs for x-position multiplexing, which is modeled as resulting from a long travel length (about 3-5 mm) of a small number of scintillation photons. This model is supported by the change observed in aperture images when the threshold number for photon-pulses was adjusted for a neutron event determination. When the threshold number of photon-pulses was set above 10 for each PMT, the ghost peaks in the aperture images and TOF spectra of powder diffraction were strongly suppressed or completely eliminated, and the intrinsic background levels of the WLS detectors were significantly reduced. Our result indicates that WLS fiber detector is a promising alternative for 3He PSDs for neutron scattering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved neutron-gamma discrimination for a {sup 6}Li-glass neutron detector using digital signal analysis methods

A {sup 6}Li-glass scintillator (GS20) based neutron Anger camera was developed for time-of-flight single-crystal diffraction instruments at Spallation Neutron Source. Traditional Pulse-Height Analysis (PHA) for Neutron-Gamma Discrimination (NGD) resulted in the neutron-gamma efficiency ratio (defined as NGD ratio) on the order of 10{sup 4}. The NGD ratios of Anger cameras need to be improved for broader applications including neutron reflectometers. For this purpose, six digital signal analysis methods of individual waveforms acquired from photomultiplier tubes were proposed using (i) charge integration, (ii) pulse-amplitude histograms, (iii) power spectrum analysis combined with the maximum pulse-amplitude, (iv) two event parameters (a{sub 1}, b{sub 0}) obtained from a Wiener filter, (v) an effective amplitude (m) obtained from an adaptive least-mean-square filter, and (vi) a cross-correlation coefficient between individual and reference waveforms. The NGD ratios are about 70 times those from the traditional PHA method. Our results indicate the NGD capabilities of neutron Anger cameras based on GS20 scintillators can be significantly improved with digital signal analysis methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron detector

A neutron detector has a volume of neutron moderating material and a plurality of individual neutron sensing elements dispersed at selected locations throughout the moderator, and particularly arranged so that some of the detecting elements are closer to the surface of the moderator assembly and others are more deeply embedded. The arrangement captures some thermalized neutrons that might otherwise be scattered away from a single, centrally located detector element. Different geometrical arrangements may be used while preserving its fundamental characteristics. Different types of neutron sensing elements may be used, which may operate on any of a number of physical principles to perform the function of sensing a neutron, either by a capture or a scattering reaction, and converting that reaction to a detectable signal. High detection efficiency, an ability to acquire spectral information, and directional sensitivity may be obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗