Search NASASearch

SEARCH · Search NASA

Results for “Neutron detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Thermal Design and Thermal Vacuum Testing of the StarBurst Instrument

The StarBurst Multimessenger Pioneer is a small satellite mission serving as a wide-field gamma-ray observatory designed to capture the initial emissions of short gamma-ray bursts, electromagnetic signatures of neutron star mergers. This paper presents the final thermal design and analysis of the StarBurst Instrument, comprising the bus-to-instrument interface plate, control electronics, and twelve crystal detector units, which form the core of the mission’s science capability. The passive thermal control system design requires consideration of restrictive keep-out zones, unknown orbital parameters, and narrow temperature limits of the detectors. Also summarized is the instrument level thermal vacuum cycle test, correlated model refinements, and updated model results. Following successful completion of the instrument test campaign, the hardware was integrated with the spacecraft bus for spacecraft level testing, including additional thermal vacuum testing. The results from the spacecraft level thermal vacuum test will further inform the instrument thermal model, ensuring accurate flight temperature predictions. StarBurst launches as a secondary payload in 2027 and has a mission duration of at least one year.

StarBurst

Final Thermal Design and Thermal Vacuum Testing of the StarBurst Instrument

The StarBurst Multimessenger Pioneer is a small satellite mission serving as a wide-field gamma-ray observatory designed to capture the initial emissions of short gamma-ray bursts, electromagnetic signatures of neutron star mergers. This paper presents the final thermal design and analysis of the StarBurst Instrument, comprising the bus-to-instrument interface plate, control electronics, and twelve crystal detector units, which form the core of the mission’s science capability. The passive thermal control system design requires consideration of restrictive keep-out zones, unknown orbital parameters, and narrow temperature limits of the detectors. Also summarized is the instrument level thermal vacuum cycle test, correlated model refinements, and updated model results. Following successful completion of the instrument test campaign, the hardware was integrated with the spacecraft bus for spacecraft level testing, including additional thermal vacuum testing. The results from the spacecraft level thermal vacuum test will further inform the instrument thermal model, ensuring accurate flight temperature predictions. StarBurst launches as a secondary payload in 2027 and has a mission duration of at least one year.

StarBurst

Interpretation of Various Radiation Backgrounds Observed in the Gamma-Ray Spectrometer Experiments Carried on the Apollo Missions and Implications for Diffuse Gamma-Ray Measurements

Since the report of a preliminary analysis of cosmic gamma-ray measurements made during the Apollo 15 mission, an improved calculation of the spallation activation contribution has been made including the effects of short-lived spallation fragments, which can extend the correction to 15 MeV. In addition, a difference between Apollo 15 and 16 data enables an electron bremsstrahlung contribution to be calculated. A high level of activation observed in a crystal returned on Apollo 17 indicates a background contribution from secondary neutrons. These calculations and observations enable an improved extraction of spurious components and suggest important improvements for future detectors.

C S Dyer

Pressurized-Cell Experiment

Pressurized-cell detectors were developed and constructed at the Langley Research Center to obtain a direct measurement of the micrometeoroid puncture hazard to thin structural material. A total of 160 detectors were mounted around the periphery of the rocket motor used on the Explorer XIII satellite. (See fig. IX-1.) Material thicknesses of 0.001, 0.0015, 0.002, 0.0025, and 0.005 inch were used on the detectors. The exposed surface of the test material of each detector was 21.8 square inches and the total exposed surface of the 160 detectors was 24.2 square feet. The average weight of the detectors was 68 grams.

Micrometeoroid

Electron Velocity Moments in the Solar Wind. I. Calibration of the Wind 3DP EESA Low Detector

Calibrated measurements of electron velocity distribution functions (VDFs) are necessary to characterize fluid and kinetic processes in weakly collisional and nearly collisionless plasmas such as the solar wind. Therefore, we analyzed 3,996,051 electron VDFs observed by the Wind 3DP thermal electron detector near 1 astronomical unit (au) between January 1, 2005 and November 25, 2017. The data were calibrated for each electron VDF to produce accurate velocity moments in the solar wind. This is the first full solar cycle coverage electron velocity moment dataset in the near-Earth solar wind. Herein (Paper I) we discuss the calibration process/algorithms and the velocity moment constraints, uncertainties, and resulting public dataset. In the second paper (Paper II), we statistically analyze the electron velocity moment dataset.

plasmas

Optimization of X-ray Absorbers for High-Resolution TES Detectors in NewATHENA X-IFU

NewATHENA’s X-ray Integral Field Unit (X-IFU) uses a large-format array of Transition Edge Sensor (TES) microcalorimeters coupled with absorbers made of gold and bismuth providing 4 eV FWHM resolution up to 7 keV in the 0.2- 12 keV band. X-ray absorbers must be thick enough for photon absorption, maintain low heat capacity for energy resolution, and have good thermalization properties. The X-IFU requires total Quantum Efficiency (QE) of 96%, 87%, and 63% at 1, 7, and 9.5 keV, respectively. Optimal thicknesses are 1.05 µm gold and 5.5 µm bismuth to achieve 0.731 pJ/K at 90 mK and 87% QE at 7 keV. While typical TES absorbers are 3-4 µm thick, producing the required 5.5 µm Bi absorbers via standard electroplating creates enlarged grains and surface roughness. The increased roughness and grain size variability produced with our standard recipe have resulted in instances of 1) low energy spectral tails 2) spectral broadening of the energy resolution and 3) thermal shorts between pixels when a large grain bridges the gap between absorbers. In this study, we have introduced a new fabrication process and altered the morphology of the thick Bi through changes in the electroplating process. The process changes are intended to address all three issues as well as reduce particulate contamination observed on the finished detector arrays.

Absorber

Copper-Wire-Card Detectors

Card Design - Each copper-wire-card detector consisted of a winding of fine wire mounted to a 1.45- by 7 .00-inch rectangular card. Two wire sizes were used - 2-mil and 3-mil (fourteen 2-mil cards and thirty-two 3-mil cards). The total exposed effective area was about 1.2 square feet (0.11 square meters). A sketch of a detector is shown in figure X-1. These detectors are similar to the detectors flown on previous satellites. Quadrant Design - The 36 cards are arranged in four groups of 12 cards each with four pairs of 3-mil cards in parallel and four single 2-mil cards in parallel. Each group is mounted on a fiber-glass support that can readily be removed from the payload for repairs or replacements with appropriate spares. Individual cards can be replaced readily if necessary. The assembly of the quadrants is shown in figure II-2. Temperature-Balance Experiment - The grids for the temperature-balance experiment were wound with insulated wire. The thermal balance of such a winding has been examined under conditions approximating flight environment. One card of 3-mil wire with a thermistor attached was enclosed in a bell jar and exposed to the sun after evacuation. External radiation was reduced by shading the bell jar except for a window which allowed the sun's rays to strike the winding. The temperature of the thermistor was recorded at intervals. Figure X-2 shows that the temperature does not rise beyond 65° C in 20 minutes of continuous exposure to the sun. Complementary tests made by Dr. Roger E. Gaumer of Lockheed Aircraft Corp. give a ratio of absorptivity to emissivity of 1 for this type of enamel insulated wire. Compensation for Resistance Changes - Temperatures at the wire-card surfaces were expected to extend from -10° C to a maximum of 60° C. Since copper has a thermal coefficient of resistance of 0.33 percent per °C, the resistance of the wire would change 22 percent and a compensator had to be provided. A 100-ohm thermistor with a negative coefficient of -3-9 percent per °C was selected, wired in parallel with a 300-ohm fixed resistor and installed in series with each 2-mil card and with each pair of 3-mil cards. The effective resistance of 2-mil and 3-mil compensated cards is shown in figure X-3 for various temperatures and compared with the resistance of uncompensated copper. The increase in resistance from 20° C to 60° C is 12 ohms or 2.7 percent. Below 20° C the effective resistance also increases and the curve is similar to that obtained for high temperatures.

Detector

The Habitable Worlds Observatory Technology Development Plan

The Habitable Worlds Observatory (HWO) is NASA’s next large space telescope, selected by the 2020 Decadal Survey in Astronomy and Astrophysics to search for and characterize habitable exoplanets while enabling a broad range of transformative astrophysics. In August 2024, the HWO Technology Maturation Project Office (TMPO) was formed to begin exploring the HWO science, technology, and mission architectures toward a Mission Concept Review (MCR) at the end of the decade. A primary deliverable of this effort is this technology development plan that identifies critical technologies that enable the mission, defines a process for assessing the readiness of those technologies, and outlines a strategy for developing those technologies to a Technology Readiness Level (TRL) of 5 before the MCR. This document covers technologies organized along three “tracks”: Coronagraph System technologies, Ultra-stable Telescope System technologies, and High-sensitivity Ultraviolet and Visible Instrumentation technologies. Additional emerging and enhancing technologies are also discussed.

technology development

Lunar Nuclear Reactor Neutron Fluence and Gamma Dose Estimates

NASA aims to deploy a fission reactor on the lunar surface by 2030 to generate 100 kWe of power for at least 10 years without maintenance or refueling. To assess system and subsystem survivability according to those requirements, a model of the reactor pallet was created in the radiation transport code MCNP to determine the neutron fluences and gamma doses that the materials and systems would be exposed to. The model was based on the 2025 government design. The model indicated that the control drum motors, Brayton cycle engines, and pipes and valves would be exposed to neutron fluences of 1×10 15 – 1×10 16 n/cm 2 per year and gamma doses ranging from 10 to 500 Mrad per year. The electronics box housing the instrumentation and control elements is expected to receive 1×10 14 – 1×10 15 n/cm 2 per year and gamma doses in the range of 1–5 Mrad per year. These doses necessitate that the control drum motors, Brayton cycle engines, valve components, control electronics, and other components be radiation-hardened (>10 16 n/cm 2 and >10 Mrad gamma dose) or additionally shielded to survive the 10-year lunar mission.

Radiation-Hardened Materials

X-Ray Polarization of Z-Type Neutron Star Low-Mass X-Ray Binaries II. Spectropolarimetric Analysis

IXPE has provided for the first time detailed energy- and time-resolved X-ray polarimetry of Z-type neutron star low-mass X-ray binaries (NS-LMXBs) as they move along their color-color diagrams (CCDs). These sources can reach the highest polarization observed for NS-LXMBs in the 2–8 keV range when they move along the horizontal branch. In a previous paper, we characterized the spectral state of a sample of Z-sources using the CCD and estimated the polarization with model-independent analysis. Here, we present detailed spectropolarimetric analysis for each source on each branch using data from IXPE, NICER, and NuSTAR. The continuum X-ray emission of all the sources is well described with a combination of thermal accretion disk emission plus a harder Comptonized component. In addition, reflection features, in particular the relativistically broadened Fe Kα line, are observed for our sources, except GX 5–1. For most of the sources and branches, the main contribution to the X-ray emission and polarization is due to Comptonization: moving from the horizontal branch (HB) to the normal branch (NB), the polarization degree (PD) in the 2–8 keV band varies from about 6% to 3–4%, while the PD is loosely constrained in the flaring branch (FB), due to the shorter exposures. These PD values are significantly higher than theoretical expectations for typical spreading or boundary layer configurations. The polarization of the disk is generally lower (below 3%) but still higher than predictions for an electron scattering-dominated, plane-parallel atmosphere above the disk observed at the corresponding inclination. Moreover, the polarization angle (PA) of the disk seems to be significantly misaligned and not perpendicular to that of Comptonization. We find no correlation between the polarization signal and the inclination, nor with the contribution of reflected photons throughout the Z-track.

accretion

High-Fidelity Modeling Approach for Coupling Thermal, Fluid, and Neutronic Analysis in an NTP Engine

Nuclear thermal propulsion (NTP), with its increased efficiency compared to traditional rocket engines, is a potentially enabling technology for space missions of higher complexity, such as delivering heavy machinery or crew to the moon or other planets. Thus, exploring modeling approaches that can effectively couple the thermal, fluid, and neutronic behaviors of NTP reactors is essential to mitigate cost and schedule challenges with hardware development. This paper details one such approach which utilizes Cardinal to unify reactor physics analysis performed using OpenMC, heat transfer analysis performed using the MOOSE framework, and thermal hydraulic analysis performed using the MOOSE Thermal Hydraulic Module. This approach is demonstrated with a proof of concept that focuses on a legacy reactor geometry from the historic NERVA program. This preliminary model found an overprediction in, when compared to the reference data, axial power peaking and the temperatures of both solids and fluids by roughly 20%. It is clear, however, that the model conserved a number of broad trends, and a few model refinements should reduce the observed error. This approach has definite merit and should enable the production of informative results for more modern NTP systems. This work is a first step in creating a transient reactor model that can be updated across a sequence of time steps based on continually fluctuating, time-dependent boundary conditions.

Nuclear Thermal Propulsion

A High Voltage Power Converter for Space Astronomy Applications

A dc-dc low-power, high-voltage converter for use in space is described which furnishes a commandable, low-noise dc output in the range of 0 to -7500 V. The converter is suitable for biasing of detectors commonly employed in space astronomy, microchannel plates, photomultipliers, and gas discharge detectors. The converter's reliability has been demonstrated by accelerated life testing under thermal vacuum. The electrical and mechanical design, packaging, layout and fabrication techniques, and tests employed are described.

David C Ray

Toward Large Field-of-view X-ray Spectrometers with Magnetic Microcalorimeters

A future X-ray telescope mission like Lynx, a X-ray flagship mission concept, requires a large field of view, high energy resolution, and high spatial resolution. The Magnetic Microcalorimeter (MMC) detectors we are developing for such a mission feature a 5-arcminute field of view, approximately 100,000 pixels, each spanning 0.5–1 arcsecond. These detectors require the readout of 8,000 sensors. Three different array types have been designed to meet scientific goals, two of which utilize thermal multiplexing to reduce the number of readout channels in a scheme called “Hydra.” We are currently fabricating detectors on a recently completed buried wiring wafer with connections to every sensor. The sensors are read out using a microwave multiplexer (μMUX) with flux ramp modulation. A single μMUX can read out approximately 1,000 sensors with only two feed lines. We will report on the test of the first two-dimensional μMUX chip, consisting of 78 resonators. μMUX chips that pass screening will be directly bonded to MMC array chips using indium bump bonding. In parallel, we have tested a kinetic inductance traveling wave parametric amplifier (KI-TWPA) to amplify signals at low temperatures. The KI-TWPA exhibits extremely low internal noise, approaching the standard quantum limit. Since the energy resolution of an MMC is primarily limited by the readout system, the KI-TWPA is an ideal amplifier for MMCs with μMUX readout. We recently measured the readout noise of a μMUX with a KI-TWPA, demonstrating its capability for reading out MMC arrays. We present the design and fabrication of the latest MMC detectors, along with its readout performance.

Magntic Microcalorimeters

Advanced Non-Intrusive Instrumentation for Propulsion Engines

Changes in engine technology such as higher temperatures, higher tip speeds, new metal/composite/ceramic materials together with radical changes in design philosophy will require amongst other prerequisites the ability to measure and to monitor key internal gas and structural characteristics. The symposium papers presented non-intrusive measurement and analysis technologies in the following categories: Laser Point Measurements (11); Absorption and Infrared Techniques (4); Paints - Surface Sensors (6); Laser Induced Fluorescence (6); Mechanical (7); Films (5); Laser Planar Measurement (9); and a Keynote Address.

Propulsion

X-Ray Polarization From the Atoll 4U 1735−44 Suggests a Low Inclination

X-ray polarimetry is a new tool capable of probing the geometry of accretion onto weakly magnetized neutron stars. Here we present the first X-ray spectro-polarimetric results from coordinated observations of the atoll source 4U 1735−44, conducted with the Imaging X-ray Polarimetry Explorer (IXPE), NICER, and NuSTAR . Over the 2–8 keV energy range, we obtained a marginal detection of polarization with the polarization degree of 1.4% ± 0.7% and polarization angle of −29◦ ± 14◦, corresponding to a 3σ upper limit on the polarization degree of 3.5%. The best-fit model to describe the spectrum comprises a thermal component associated with the accretion disk, a Comptonized black body component, and a relativistic reflection component. From the reflection model, we infer a disk inclination of ∼40◦. The spectroscopic and polarimetric properties of 4U 1735−44 are consistent with those observed in other atoll sources studied by IXPE, with its low polarization likely due to its low inclination

X-rays: binaries

Ultraviolet-Excimer Laser-Based Incoherent Doppler Lidar System

The topics covered include the following: principles of Doppler measurements, laser backscatter, eye safety, demonstration concepts, the wavelength-meter, the interferometer detector, return signal model, and comparison of incoherent and coherent lidars.

I Stuart McDermid

In-Flight Calibration of ESA Hera’s Hyperscout-H Imager

ESA’s Hera space mission is on its way to the mission target, the binary asteroid (65803) Didymos. HyperScout-H, one of the instruments onboard Hera, is a hyperspectral imager operating in the visible and near-infrared regions between 0.65 and 0.95 μm. HyperScout-H will enable a detailed assessment of the composition of both objects, Didymos and its satellite Dimorphos, the characterization of space weathering effects, and the possible presence of exogenous material on their surfaces. To monitor instrument functionality, calibration exposures are acquired regularly. This article describes the in-flight calibrations carried out for HyperScout-H during the commissioning and cruise phases. Bias and dark exposures, as well as stellar field observations, were acquired several times after launch. We update the calibration data and monitor instrument performance in the space environment. In addition, images of Earth and Moon were acquired from distances of 1.5 × 10 6 to 2.0 × 10 6 km, and Mars and its satellite were imaged during the flyby. In five images, the surface of Mars fills the entire field of view, enabling cross-validation of HyperScout-H results with those reported by other Mars missions. We characterize the detector under in-flight operational conditions. The calibration data indicate that the bias pattern is stable, the dark current remains negligible for short exposures, and the detector response is highly linear. We quantify the field-of-view alignment and geometric distortion, and evaluate the point spread function based on the stellar field observations. Stellar observations and Mars swing-by data provide updated radiometric calibration constants, suggesting that in-flight conditions have slightly modified the detector’s spectral response. In-flight calibrations are essential to ensure data quality and reliability.

Image Processing

On-Orbit Calibration Assessment of NOAA-21 VIIRS Thermal Emissive Bands and Implications for JPSS-4 VIIRS

The Visible Infrared Imaging Radiometer Suite (VIIRS) instrument onboard the NOAA-21 (N21) satellite has been successfully operating for over three years collecting valuable scientific measurements. A large suite of weather forecasting models and scientific research applications are supported with the VIIRS measurements from N21 combined with those acquired from the VIIRS instrument onboard the S-NPP and NOAA-20 spacecraft. Among the 22 VIIRS spectral bands, there are seven thermal emissive bands (TEB) covering the 3.7 to 12.2 µm spectral range at two different spatial resolutions. The VIIRS TEB detectors are calibrated onboard using a blackbody at a controlled temperature and a space view for background signal measurement. In this paper, we discuss the on-orbit performance of the N21 VIIRS TEB using various parameters such as the detector gain, noise, and offset. This on-orbit assessment provides critical insights into instrument behavior and calibration performance that will inform pre-launch testing and post-launch validation strategies for the upcoming JPSS-4 VIIRS mission scheduled for launch in 2027. The methodologies and lessons learned from characterizing the N21 TEB performance will enable more efficient and comprehensive radiometric assessment of the next VIIRS instrument. Specific focus is placed on identifying performance trends and anomaly signatures observed during the N21 commissioning phase that can enhance the JPSS4 instrument checkout procedures and accelerate the transition to routine on-orbit operations. The established performance baselines and uncertainty estimates will serve as an acceptance criterion for the JPSS-4 commissioning activities, ensuring mission readiness and data continuity for operational users.

Amit Angal