Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron skin thickness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

A preliminary area survey of neutron radiation levels associated with the NASA variable energy cyclotron horizontal neutron delivery system

The 25 MeV deuteron beam from the NASA variable energy cyclotron incident on a thick beryllium target will deliver a tissue neutron dose rate of 2.14 rad micron A-min at a source to skin distance of 125 cm. A neutron survey of the existing hallways with various shielding configurations made during operating of the horizontal neutron delivery system indicates that minimal amounts of additional neutron shielding material are required to provide a low level radiation environment within a self-contained neutron therapy control station. Measurements also indicate that the primary neutron distribution delivered by a planned vertical delivery system will be minimally perturbed by neutrons backscattered from the floor.

Roberts, W. K.↗

Risk analyses for the solar particle events of August through December 1989

The solar particle events of August through December 1989, among the largest ever recorded, are analyzed to assess the potential hazards to humans on interplanetary missions from events of these types. Using the coupled neutron-proton space radiation transport computer code BRYNTRN, risk estimates for the effects of exposures to the skin, ocular lens, and bone marrow are made for nominal thicknesses of the spacecraft aluminum shielding. Risk assessment in terms of absorbed dose is made for each event. Also presented are estimates of organ absorbed dose and dose equivalent for pairs of events which occurred within 30-day periods, and for the cumulative August through December 1989 period.

Townsend, Lawrence W.↗

Large solar flare radiation shielding requirements for manned interplanetary missions

Estimates are given for the radiation shielding thicknesses required to protect astronauts on interplanetary missions from the effects of large solar flares, on the basis of the integral proton fluences for several past solar particle events. NASA-Langley's nucleon transport deterministic computer code, BRYNTRN, is used to transport primary protons and secondary protons and neutrons through any number of layers of target material of arbitrary thickness and composition. The results of each flare are presented as estimates of dose equivalents to the skin, eyes, and blood-forming organs behind various thicknesses of aluminum shielding.

Townsend, Lawrence W.↗

Human exposure to large solar particle events in space

Whenever energetic solar protons produced by solar particle events traverse bulk matter, they undergo various nuclear and atomic collision processes which significantly alter the physical characteristics and biologically important properties of their transported radiation fields. These physical interactions and their effect on the resulting radiation field within matter are described within the context of a recently developed deterministic, coupled neutron-proton space radiation transport computer code (BRYNTRN). Using this computer code, estimates of human exposure in interplanetary space, behind nominal (2 g/sq cm) and storm shelter (20 g/sq cm) thicknesses of aluminum shielding, are made for the large solar proton event of August 1972. Included in these calculations are estimates of cumulative exposures to the skin, ocular lens, and bone marrow as a function of time during the event. Risk assessment in terms of absorbed dose and dose equivalent is discussed for these organs. Also presented are estimates of organ exposures for hypothetical, worst-case flare scenarios. The rate of dose equivalent accumulation places this situation in an interesting region of dose rate between the very low values of usual concern in terrestrial radiation environments and the high-dose-rate values prevalent in radiation therapy.

Townsend, L. W.↗

Development of a Neutron Spectrometer to Assess Biological Radiation Damage Behind Spacecraft Materials

Astronauts who spend months and years traveling long distances in spacecraft and working on other planets will be subjected to high energy radiation of galactic and solar origin without the protection of the Earth's thick (one writer has called it buff) atmosphere and magnetic field. The lack of natural protection will allow high energy cosmic ray particles and solar protons to crash directly into relatively thin spacecraft walls and planetary atmospheres producing energetic secondary particles in these collisions. A substantial fraction of these secondaries will be neutrons that carry no electric charge and, consequently, are difficult to detect. At sea level on Earth the remaining neutrons are the result of many generations (approximately 10) of collisions, have very low energies (scientists call them thermal neutrons), and do not penetrate deeply into the human body. They do contribute to the natural background radiation seen by humans on Earth, but much of the dose is only at the surface or skin of the body. In the International Space Station or on the surface of Mars, the secondary neutrons will be the result of only one or two generations of interaction due to the thinner (about a factor of 20 compared to the Earth's atmosphere) walls or atmosphere, have considerably more energy and penetrate deeply into the human body. In addition, neutrons are substantially moderated by hydrogenous material such as water. A significant fraction of the water exists in the astronaut's body. Therefore, the neutron can not only penetrate more deeply into the body, but also be stopped there and deposit all or most of its radiation dose in organs such as the liver, spleen, kidney, etc. We hypothesize that the risk of serious cancers will be increased for the exposed humans. The portable, real time neutron spectrometer being developed by our team will monitor the environment inside spacecraft structures and on planetary surfaces. Activities supported by this grant will evaluate the neutron environment inside several candidate spacecraft materials at accelerator facilities. These experiments will enable engineers to choose the structure materials that minimize the production of secondary neutrons. With the information that the neutron energy spectrometer produces, scientists and doctors will be able to assess the increased risk of cancer and develop countermeasures. The instrument itself will include an alarm system to warn astronauts when high radiation fluxes are occurring so that they can seek shelter immediately.

Maurer, R. H.↗

Space radiation absorbed dose distribution in a human phantom

The radiation risk to astronauts has always been based on measurements using passive thermoluminescent dosimeters (TLDs). The skin dose is converted to dose equivalent using an average radiation quality factor based on model calculations. The radiological risk estimates, however, are based on organ and tissue doses. This paper describes results from the first space flight (STS-91, 51.65 degrees inclination and approximately 380 km altitude) of a fully instrumented Alderson Rando phantom torso (with head) to relate the skin dose to organ doses. Spatial distributions of absorbed dose in 34 1-inch-thick sections measured using TLDs are described. There is about a 30% change in dose as one moves from the front to the back of the phantom body. Small active dosimeters were developed specifically to provide time-resolved measurements of absorbed dose rates and quality factors at five organ locations (brain, thyroid, heart/lung, stomach and colon) inside the phantom. Using these dosimeters, it was possible to separate the trapped-proton and the galactic cosmic radiation components of the doses. A tissue-equivalent proportional counter (TEPC) and a charged-particle directional spectrometer (CPDS) were flown next to the phantom torso to provide data on the incident internal radiation environment. Accurate models of the shielding distributions at the site of the TEPC, the CPDS and a scalable Computerized Anatomical Male (CAM) model of the phantom torso were developed. These measurements provided a comprehensive data set to map the dose distribution inside a human phantom, and to assess the accuracy and validity of radiation transport models throughout the human body. The results show that for the conditions in the International Space Station (ISS) orbit during periods near the solar minimum, the ratio of the blood-forming organ dose rate to the skin absorbed dose rate is about 80%, and the ratio of the dose equivalents is almost one. The results show that the GCR model dose-rate predictions are 20% lower than the observations. Assuming that the trapped-belt models lead to a correct orbit-averaged energy spectrum, the measurements of dose rates inside the phantom cannot be fully understood. Passive measurements using 6Li- and 7Li-based detectors on the astronauts and inside the brain and thyroid of the phantom show the presence of a significant contribution due to thermal neutrons, an area requiring additional study.

STS-91 Shuttle Project↗