Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron spectrum unfolding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evaluating the performance of two neutron spectrum unfolding codes based on iterative procedures and artificial neural networks

In this work the performance of two neutron spectrum unfolding codes based on iterative procedures and artificial neural networks is evaluated. The first one code based on traditional iterative procedures and called Neutron spectrometry and dosimetry from the Universidad Autonoma de Zacatecas (NSDUAZ) use the SPUNIT iterative algorithm and was designed to unfold neutron spectrum and calculate 15 dosimetric quantities and 7 IAEA survey meters. The main feature of this code is the automated selection of the initial guess spectrum trough a compendium of neutron spectrum compiled by the IAEA. The second one code known as Neutron spectrometry and dosimetry with artificial neural networks (NDSann) is a code designed using neural nets technology. The artificial intelligence approach of neural net does not solve mathematical equations. By using the knowledge stored at synaptic weights on a neural net properly trained, the code is capable to unfold neutron spectrum and to simultaneously calculate 15 dosimetric quantities, needing as entrance data, only the rate counts measured with a Bonner spheres system. Similarities of both NSDUAZ and NSDann codes are: they follow the same easy and intuitive user's philosophy and were designed in a graphical interface under the LabVIEW programming environment. Both codes unfold the neutron spectrum expressed in 60 energy bins, calculate 15 dosimetric quantities and generate a full report in HTML format. Differences of these codes are: NSDUAZ code was designed using classical iterative approaches and needs an initial guess spectrum in order to initiate the iterative procedure. In NSDUAZ, a programming routine was designed to calculate 7 IAEA instrument survey meters using the fluence-dose conversion coefficients. NSDann code use artificial neural networks for solving the ill-conditioned equation system of neutron spectrometry problem through synaptic weights of a properly trained neural network. Contrary to iterative procedures, in neural net approach it is possible to reduce the rate counts used to unfold the neutron spectrum. To evaluate these codes a computer tool called Neutron Spectrometry and dosimetry computer tool was designed. The results obtained with this package are showed. The codes here mentioned are freely available upon request to the authors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NSDann2BS, a neutron spectrum unfolding code based on neural networks technology and two bonner spheres

In this work a neutron spectrum unfolding code, based on artificial intelligence technology is presented. The code called ''Neutron Spectrometry and Dosimetry with Artificial Neural Networks and two Bonner spheres'', (NSDann2BS), was designed in a graphical user interface under the LabVIEW programming environment. The main features of this code are to use an embedded artificial neural network architecture optimized with the ''Robust design of artificial neural networks methodology'' and to use two Bonner spheres as the only piece of information. In order to build the code here presented, once the net topology was optimized and properly trained, knowledge stored at synaptic weights was extracted and using a graphical framework build on the LabVIEW programming environment, the NSDann2BS code was designed. This code is friendly, intuitive and easy to use for the end user. The code is freely available upon request to authors. To demonstrate the use of the neural net embedded in the NSDann2BS code, the rate counts of {sup 252}Cf, {sup 241}AmBe and {sup 239}PuBe neutron sources measured with a Bonner spheres system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data Augmentation for Neutron Spectrum Unfolding with Neural Networks

Neural networks require a large quantity of training spectra and detector responses in order to learn to solve the inverse problem of neutron spectrum unfolding. In addition, due to the under-determined nature of unfolding, non-physical spectra which would not be encountered in usage should not be included in the training set. While physically realistic training spectra are commonly determined experimentally or generated through Monte Carlo simulation, this can become prohibitively expensive when considering the quantity of spectra needed to effectively train an unfolding network. In this paper, we present three algorithms for the generation of large quantities of realistic and physically motivated neutron energy spectra. Using an IAEA compendium of 251 spectra, we compare the unfolding performance of neural networks trained on spectra from these algorithms, when unfolding real-world spectra, to two baselines. We also investigate general methods for evaluating the performance of and optimizing feature engineering algorithms.

McGreivy, James (ORCID:0000000321723411)↗

Unfolding neutron spectrum with Markov Chain Monte Carlo at MIT research Reactor with He-3 Neutral Current Detectors [Measuring neutron spectrum at MIT research reactor utilizing He-3 Bonner Cylinder Approach with an unfolding analysis]

Here, the Ricochet experiment seeks to measure Coherent (neutral-current) Elastic Neutrino-Nucleus Scattering (CEνNS) using dark-matter-style detectors with sub-keV thresholds placed near a neutrino source, such as the MIT (research) Reactor (MITR), which operates at 5.5 MW generating approximately 2.2 × 10 18 ν/second in its core. Currently, Ricochet is characterizing the backgrounds at MITR, the main component of which comes in the form of neutrons emitted from the core simultaneous with the neutrino signal. To characterize this background, we wrapped Bonner cylinders around a 3 2 He thermal neutron detector, whose data was then unfolded via a Markov Chain Monte Carlo (MCMC) to produce a neutron energy spectrum across several orders of magnitude. We discuss the resulting spectrum and its implications for deploying Ricochet at the MITR site as well as the feasibility of reducing this background level via the addition of polyethylene shielding around the detector setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of neutron spectrum unfolding using deuterated liquid scintillator

The performance of the maximum likelihood expectation maximization method for unfolding neutron energy spectra using deuterated liquid scintillator is evaluated for future utilization with rare isotope beams. High-resolution neutron energy spectra as well as the detector response matrix were measured at the Edwards Accelerator Laboratory at Ohio University. Maximum-likelihood expectation maximization (MLEM) unfolded neutron spectra are compared with spectra from neutron time-of-flight. In conclusion, the effects of the MLEM stopping criteria and spectrum statistics are also investigated.

47 OTHER INSTRUMENTATION↗

Time-of-flight neutron spectrum unfolding for mixed-oxide nuclear fuel and plutonium metal using a dual-particle imager

A dual-particle imager with sensitivity to both neutrons and photons has been developed for the detection of special nuclear material. This system has the capability to provide spectral information on detected sources that is useful for safeguard applications. In nuclear facilities with high photon background rates, neutron detection can aid in identification and verification capabilities. The dual-particle imager creates a reconstructed neutron spectrum by correlating neutron counts in pairs of liquid scintillators. The reconstructed spectrum, a combination of energy deposited and time-of-flight, contains resolution effects that blur the true, emitted source-spectrum. To reduce the impact of resolution effects, the reconstructed spectrum can be unfolded to create an estimated source spectrum. A statistical technique, maximum-likelihood expectation-maximization, has been shown to produce an unfolded result for Cf-252 and Am-Be. This technique requires a system response-matrix that contains reconstructed spectra for single neutron energies. Since measuring mono-energetic neutrons is difficult, the system-response-matrix is simulated. Monte Carlo modeling with MCNPX-PoliMi has been show to produce an accurate system response. This work expands on previous neutron unfolding results by showing results for mixed-oxide fuel and plutonium metal measured with the dual-particle imager. Furthermore these results also demonstrate the ability of the dual-particle imager to discrimination between spontaneous fission neutrons and (α,n) reaction neutrons.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Warhead verification as inverse problem: Applications of neutron spectrum unfolding from organic-scintillator measurements

Verification of future warhead-dismantlement treaties will require detection of certain warhead attributes without the disclosure of sensitive design information, and this presents an unusual measurement challenge. Neutron spectroscopy—commonly eschewed as an ill-posed inverse problem—may hold special advantages for warhead verification by virtue of its insensitivity to certain neutron-source parameters like plutonium isotopics. In this article, we investigate the usefulness of unfolded neutron spectra obtained from organic-scintillator data for verifying a particular treaty-relevant warhead attribute: the presence of high-explosive and neutron-reflecting materials. Toward this end, several improvements on current unfolding capabilities are demonstrated: deuterated detectors are shown to have superior response-matrix condition to that of standard hydrogen-base scintintillators; a novel data-discretization scheme is proposed which removes important detector nonlinearities; and a technique is described for re-parameterizing the unfolding problem in order to constrain the parameter space of solutions sought, sidestepping the inverse problem altogether. These improvements are demonstrated with trial measurements and verified using accelerator-based time-of-flight calculation of reference spectra. Then, a demonstration is presented in which the elemental compositions of low-Z neutron-attenuating materials are estimated to within 10%. These techniques could have direct application in verifying the presence of high-explosive materials in a neutron-emitting test item, as well as other for treaty verification challenges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation and Verification of Python based Neutron Spectrum Unfolding Software

To validate and verify the python-based code (PySL), designed to replicate the programs used by STAYSL for Beam Correction Factor (BCF) and Self-Shielding Factor (SHIELD), a series of tests were performed. To test BCF a python script was written to generate a random flux history file and both versions of the code processed the data. The test verified matching values up to at least one decimal place, approximately 10,000 tests where run and each one passed. Isotopes began to fail the tests once neutron saturation was reached. To verify this the total time of exposure was varied the isotopes that failed were compared to a list of their half-lives. The test process for SHIELD was very similar but, in this case, the code began by producing an input file with varying thickness and device type/environment for the SHIELD input. The failure condition for this test was if any of the data points for an isotope had a difference above 3%. Approximately 40 of these tests were run and there were only 3 isotopes that had reoccurring failures but only 2% of their points were above the 3% difference. A visual comparison was conducted by plotting the results from both programs. Although the test failed, the differences between their values were minuscule, and the self-shielding factor’s shape was preserved when plotted. Next steps for this project will be validating and verifying the python-based SigPhi code and then reproducing and testing the least squares unfolding performed by STAYSL.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A New Method of Prompt Fission Neutron Energy Spectrum Unfolding

The prompt neutron emission in spontaneous fission of {sup 252}Cf has been investigated applying digital signal electronics along with associated digital signal processing algorithms. The goal was to find out the reasons of a long time existing discrepancy between theoretical calculations and the measurements of prompt fission neutron (PFN) emission dependence on the total kinetic energy (TKE) of fission fragments (FF). On the one hand the {sup 252}Cf(sf) reaction is one of the main references for nuclear data, on the other hand the understanding of PFN emission mechanism is very important for nuclear fission theory. Using a twin Frisch-grid ionization chamber for fission fragment (FF) detection and a NE213-equivalent neutron detector in total about 10{sup 7} fission fragment-neutron coincidences have been registered. Fission fragment kinetic energy, mass and angular distribution, neutron time-of-flight and pulse shape have been investigated using a 12 bit waveform digitizer. The signal waveforms have been analyzed using digital signal processing algorithms. For the first time the dependence of the number of emitted neutrons as a function of total kinetic energy (TKE) of the fragments is in very good agreement with theoretical calculations in the range of TKE from 140-220 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characteristics of SiC neutron sensor spectrum unfolding process based on Bayesian inference

This paper deals with SiC detector signal interpretation in neutron radiation measurements in mixed neutron gamma radiation fields, which is called the detector inverse problem or the spectrum unfolding, and it aims in finding a representation of the primary radiation, based on the measured detector signals. In our novel methodology we resort to Bayesian inference approach. In the developed procedure the resultant spectra is unfolded form detector channels reading, where the estimated neutron fluence in a group structure is obtained with its statistical characteristic comprising of standard deviation and correlation matrix. In the paper we present results of unfolding process for case of D-T neutron source in neutron moderating environment. Discussions of statistical properties of obtained results are presented as well as of the physical meaning of obtained correlation matrix of estimated group fluence. The presented works has been carried out within the I-SMART project, which is part of the KIC InnoEnergy R and D program. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron response function characterization of 4 He scintillation detectors

Time-of-flight measurements were conducted to characterize the neutron energy response of pressurized 4He fast neutron scintillation detectors for the first time, using the Van de Graaff generator at Ohio University. The time-of-flight spectra and pulse height distributions were measured. This data was used to determine the light output response function, which was found to be linear at energies below 3.5 MeV. The intrinsic efficiency of the detector as a function of incident energy was also calculated: the average efficiency up to 10 MeV was 3.1%, with a maximum efficiency of 6.6% at 1.05 MeV. Furthermore, these results will enable development of neutron spectrum unfolding algorithms for neutron spectroscopy applications with these detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimising Foil Selection for Neutron Activation Systems

Abstract Neutron spectrum unfolding using activation foils is currently the primary technique planned for measuring the neutron energy spectrum at the first wall of power-generating fusion reactors. Room for improvement in the effectiveness of current foil selection was identified, and a program produced to select foils procedurally in order to maximise the accuracy of the unfolding procedure. Using Kullback–Leibler Divergence to quantify the accuracy, the spectrum unfolded by the procedurally selected set of foils is found to be more accurate than the spectrum unfolded by a set of foils used in the literature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detector Characterization for Accurate Monte Carlo Simulation and Neutron Energy-spectrum Unfolding

This report details the characterization of a deuterated scintillation detector for use in neutron spectroscopy via the spectrum unfolding technique. The active volume of the detector consists of a 3-in. diameter by 3 in. depth right circular cylinder that contains 337 cm3 of liquid scintillator EJ-315, deuterated benzene with a D:H ratio of 141:1. A deuterated scintillator is desirable for unfolding fast neutron energy spectra because the backscattering of neutrons from deuterium produces peaks in the pulse height response corresponding to the incident neutron energy. Spectrum unfolding requires the detector’s response to be accurately known for any input neutron energy. The characterization in this report supports using a simulated response matrix calibrated by the measured light output and convolved with the measured resolution to produce a response matrix without bringing the detector to a neutron beam facility for characterization. In particular, characterization measurements were performed that included calibration of the detector’s light output to recoil electrons from gamma sources, calibration of the detector’s resolution to recoil electrons, and calibration of the detector’s light output to recoil protons from a time-tagged neutron source and a monoenergetic 14.1 MeV neutron source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Neutron Spectroscopy with Organic Scintillation Detectors in a High-Radiation Environment

Organic scintillators with pulse shape discrimination capability are widely used in both research and practical applications of neutron detection. The neutron and gamma-ray identification performance of the detector depends on the classification algorithms, noise filters and pileup rejection criteria in a high-flux bremsstrahlung radiation environment. In this paper, a technique has been developed and implemented for the neutron detection with multiple filter and discrimination steps, which to a high confidence level eliminates counting of gamma-ray pulses. Such a technique is merited when making measurements in a high flux bremsstrahlung and secondary fluorescence environment. The EJ-309 and stilbene detectors coupled to the digital data acquisition system were used for the calibration assessments with standard gamma-ray and neutron sources such as 137Cs, 60Co, 252Cf, and Am-Be. The MCNPX-PoliMi and GEANT4 toolkits were used to simulate the light output and the optical photon transport in the scintillators and create detector response functions for each type of detector. The neutron spectrum unfolding algorithm, GRAVELW, was used to recreate and calibrate with the Am-Be as final step before applying the neutron detection system to extract fusion neutron spectra generated in an intense bremsstrahlung radiation environment. This new technique described offers the user the ability to measure neutron spectra in a high-flux gamma-ray field and tune the parameters to meet required filtering needs.

Neutron Detector, Organic Scintillator, PulseShape↗

Neutron Fluence and Kerma Responses to Bare, Steel-Reflected, and Lucite-Reflected Steady-State Operations of the ORNL Health Physics Research Reactor

The experiments evaluated in this report were conducted at the Health Physics Research Reactor (HPRR), also known as the Fast Burst Reactor. The reactor was designed and built at Oak Ridge National Laboratory (ORNL) in 1961. In this evaluation, a total of 12 experiments were evaluated (6 shield configurations and two responses). Six of them are considered acceptable as benchmark experiments and are thoroughly described: the measurands are bare, steel-shielded and Lucite-shielded neutron fluences and neutron KERMA responses to steady-state operations of the HPRR. It is important to mention that there is a general lack of information in the experimental methodology and neutron spectrum unfolding, and in some cases, unexpected and unexplained discrepancies between calculation and experiment. The HPRR’s unique characteristics were that it is a fast reactor, the use of a Lucite shield as the shielding material, and the use of the neutron fluence as the main benchmark measurand. There are no known, significant correlations between benchmarks in this evaluation and benchmarks in other evaluations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Passive Confirmation of the Presence Of High-Explosive Material Via Neutron Transmission Spectroscopy

The goal of this project was to explore a novel approach for identifying presence and potential types of high explosives (HE) in treaty-controlled items with passive neutron sources by using passive neutron transmission spectroscopy. We predominantly look to measure relative elemental abundance of Carbon, Hydrogen, Oxygen, and Nitrogen (CHON) since most relevant materials are certain mix of these elements, as shown in Table 1. Previously, most studies exploring potential identification of CHON elemental content of targets in the vicinity of passive neutron source were focused solely on gamma spectroscopy using high resolution gamma detectors. Using neutron transmission spectroscopy with pulse-shape discrimination (PSD) capable organic scintillators is not only a novel idea in of itself, but arguably necessary for accurate identification of the CHON elemental content of an interrogated target. While high resolution gamma spectroscopy in principle can determine a presence of hydrogen and nitrogen, it is effectively blind to a quantitatively measuring areal densities of C, O. The initially proposed approach, described in detail in the project proposal, was to leverage previous Monte Carlo study on neutron transmission spectroscopy using slab shaped target interrogated with well-collimated (“pencil”) neutron beam. In this study, a simulated test CO 2 target was interrogated by a pencil neutron beam and transmitted neutron spectra were measured using PSD capable organic scintillator using MLEM based unfolding technique. To establish relative elemental content of carbon and oxygen, the unfolded neutron spectrum was fit with a parametrized combination of their respective elemental spectral templates. The individual spectral template was calculated by convoluting ENDF neutron crosssection with the known resolution of the PSD detector used in the study. This approach in the studied configuration successfully quantitatively established relative elemental composition of carbon and oxygen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗