Results for “Noise Figure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Noise figure of amplified dispersive Fourier transformation

Amplified dispersive Fourier transformation (ADFT) is a powerful tool for fast real-time spectroscopy as it overcomes the limitations of traditional optical spectrometers. ADFT maps the spectrum of an optical pulse into a temporal waveform using group-velocity dispersion and simultaneously amplifies it in the optical domain. It greatly simplifies spectroscopy by replacing the diffraction grating and detector array in the conventional spectrometer with a dispersive fiber and single-pixel photodetector, enabling ultrafast real-time spectroscopic measurements. Following our earlier work on the theory of ADFT, here we study the effect of noise on ADFT. We derive the noise figure of ADFT and discuss its dependence on various parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Noise and Noise Figure for Radar Receivers

An important characteristic of a radar receiver is the noise level within the receiver chain. The common parameter that specifies this is the System Noise Factor, which depends on system design and may vary with gain settings, temperature, and other factors. A modified Y-factor technique is detailed to calculate System Noise Factor for a radar receiver. Error sources are also detailed.

47 OTHER INSTRUMENTATION↗

Extraction and Analysis of Noise Parameters of On Wafer HEMTs up to 26.5 GHz

This paper presents a procedure for extracting the four noise parameters of on wafer scaled HEMTs based on AlGaAs/GaAs heterostructure. This procedure relies on 50-{omega} noise figure measurements up to 26.5 GHz by determining the equivalent temperatures associated to the intrinsic resistances of the small signal equivalent circuit. The non-quasi-static effect associated to the gate-drain resistance R{sub gd} is accounted for by the noise model. A good agreement between measured and simulated noise figure is obtained and scaling of the noise parameters is reported.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Designing high power targets with computational fluid dynamics (CFD)

High power liquid hydrogen (LH2) targets, up to 850 W, have been widely used at Jefferson Lab for the 6 GeV physics program. The typical luminosity loss of a 20 cm long LH2 target was 20% for a beam current of 100 μA rastered on a square of side 2 mm on the target. The 35 cm long, 2500 W LH2 target for the Qweak experiment had a luminosity loss of 0.8% at 180 μA beam rastered on a square of side 4 mm at the target. The Qweak target was the highest power liquid hydrogen target in the world and with the lowest noise figure. The Qweak target was the first one designed with CFD at Jefferson Lab. A CFD facility is being established at Jefferson Lab to design, build and test a new generation of low noise high power targets.

43 PARTICLE ACCELERATORS↗

A multi-slot surface coil for MRI of dual-rat imaging at 4T

A slotted surface coil inspired by the hole-and-slot cavity magnetron was developed for magnetic resonance imaging of obese rats at 4 T. Full-wave analysis of the magnetic field was carried out at 170 MHz for both the slotted and circular-shaped coils. The noise figure values of two coils were investigated via the numerical calculation of the quality factors. Fat simulated phantoms to mimic overweight rats were included in the analysis with weights ranging from 300 to 900 g. The noise figures were 1.2 dB for the slotted coil and 2.4 dB for the circular coil when loaded with 600 g of simulated phantom. A slotted surface coil with eight circular slots and a circular coil with similar dimensions were built and operated in the transceiver mode, and their performances were experimentally compared. The imaging tests in phantoms demonstrated that the slotted surface coil has a deeper RF-sensitivity and better field uniformity than the single-loop RF-coil. High quality images of two overweight Zucker rats were acquired simultaneously with the slotted surface coil using standard spin-echo pulse sequences. Experimental results showed that the slotted surface coil outperformed the circular coil for imaging considerably overweight rats. Thus, the slotted surface coil can be a good tool for MRI experiments in rats on a human whole-body 4 T scanner.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A High-Order L-Band HTS Filter for Sensitive Detecting

In this paper, a new high-temperature superconducting (HTS)-based microwave radiometer with an improved sensitivity is presented. The cryogenic receiver front end consists of an HTS filter and a cryogenic low noise amplifier (LNA). The cryogenic receiver front end shows an ultra-low noise figure and can suppress radio frequency interference (RFI) effectively. The proposed HTS filter works at a center frequency of 1.4135 GHz with a bandwidth of 25 MHz. The measured mid-band insertion loss, side band steepness, and out-of-band attenuation of the HTS filter are 0.14 dB, 35 dB/MHz, and 80 dB, respectively. The noise figure of the cryogenic LNA is about 0.27 dB at a temperature of 77 K. Compared with other total power radiometers, the proposed radiometer has a lower receiver noise temperature, which can improve the sensitivity with a short integration time of the satellite-based salinity meter. In addition, since the bandwidth of the salinity meter is fixed and the integration time of satellite-based equipment is limited, such a low receiver noise temperature can increase the flexibility of future satellite payload configuration program.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Performance of a High-Concentration Erbium-Doped Fiber Amplifier with 100 nm Amplification Bandwidth

Increasing demand for higher bandwidth has driven the need for higher Wavelength Division Multiplexing (WDM) channels. One of the requirements to achieve this is a broadband amplifier. This paper reports the performance of a broadband, compact, high-concentration and silica-based erbium-doped fiber amplifier. The amplifier optimized to a 2.15 m long erbium-doped fiber with erbium ion concentration of 2000 ppm. The gain spectrum of the amplifier has a measured amplification bandwidth of 100 nm using a 980 nm laser diode with power of 150 mW. This silica-based EDFA shows lower noise figure, higher gain and wider bandwidth in shorter wavelengths compared to Bismuth-based EDFA with higher erbium ion concentration of 3250 ppm at equivalent EDF length. The silica-based EDF shows peak gain at 22 dB and amplification bandwidth between 1520 nm and 1620 nm. The lowest noise figure is 5 dB. The gain is further improved with the implementation of enhanced EDFA configurations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

32 Channel × 40 Gb/s WDM optical communication system utilizing different configurations of hybrid fiber amplifier

In this paper, a simulation analysis of 40 Gb/s wavelength division multiplexing system of 32 channels is implemented through RZ modulation format by using a different hybrid fiber amplifier (HFA) configurations, namely, serial HFA, parallel HFA, and combined serial–parallel hybrid fiber amplifier (CSP-HFA). The performance of the proposed amplifiers is compared in terms of average gain level, average noise figure, flat gain bandwidth. In addition, quality factor, bit error rate, and eye diagram for the demonstrated 32 channel × 40 Gb/s wavelength division multiplexing optical communication system utilizing different configurations of the hybrid fiber amplifier is compared. The CSP-HFA shows better performance than serial and parallel hybrid amplifiers in terms of wider flat gain bandwidth, higher quality factor, lower bit error rate, and wider and clearer eye opening. Furthermore, CSP-HFA exhibits a flat gain bandwidth of 65 nm with an acceptable average gain of 16 dB and average noise figure of 7 dB.

42 ENGINEERING↗

E-band Nd 3+ amplifier based on wavelength selection in an all-solid micro-structured fiber

Here, a Nd 3+ fiber amplifier with gain from 1376 nm to 1466 nm is demonstrated. This is enabled by a wavelength selective waveguide that suppresses amplified spontaneous emission between 850 nm and 1150 nm. It is shown that while excited state absorption (ESA) precludes net gain below 1375 nm with the exception of a small band from 1333 nm to 1350 nm, ESA diminishes steadily beyond 1375 nm allowing for the construction of an efficient fiber amplifier with a gain peak at 1400 nm and the potential for gain from 1375 nm to 1500 nm. A peak small signal gain of 13.3 dB is measured at 1402 nm with a noise figure of 7.6 dB. Detailed measurements of the Nd 3+ emission and excited state absorption cross sections suggest the potential for better performance in improved fibers. Specifically, reduction of the fiber mode field diameter from 10.5 µm to 5.25 µm and reduction of the fiber background loss to <10 dB/km at 1400 nm should enable construction of an E-band fiber amplifier with a noise figure < 5 dB and a small signal gain > 20 dB over 30 nm of bandwidth. Such an amplifier would have a form factor and optical properties similar to current erbium fiber amplifiers, enabling modern fiber optic communication systems to operate in the E-band with amplifier technology similar to that employed in the C and L bands.

42 ENGINEERING↗

Non-reciprocal acoustoelectric microwave amplifiers with net gain and low noise in continuous operation

Abstract Piezoelectric acoustic devices that are integrated with semiconductors can leverage the acoustoelectric effect, allowing functionalities such as gain and isolation to be achieved in the acoustic domain. This could lead to performance improvements and miniaturization of radio-frequency electronic systems. However, acoustoelectric amplifiers that offer a large acoustic gain with low power consumption and noise figure at microwave frequencies in continuous operation have not yet been developed. Here we report non-reciprocal acoustoelectric amplifiers that are based on a three-layer heterostructure consisting of an indium gallium arsenide (In 0.53 Ga 0.47 As) semiconducting film, a lithium niobate (LiNbO 3 ) piezoelectric film, and a silicon substrate. The heterostructure can continuously generate 28.0 dB of acoustic gain (4.0 dB net radio-frequency gain) for 1 GHz phonons with an acoustic noise figure of 2.8 dB, while dissipating 40.5 mW of d.c. power. We also create a device with an acoustic gain of 37.0 dB (11.3 dB net gain) at 1 GHz with 19.6 mW of d.c. power dissipation and a non-reciprocal transmission of over 55 dB.

42 ENGINEERING↗

Low noise, low heat dissipation, high gain AC-DC front end amplification for scanning probe microscopy.

We report here on the design, construction and testing of a vacuum compatible AC-DC amplification system for low signal measurements with scanning probes. The most important feature of this new amplification system is incorporated within the head of a scanning tunneling microscope (STM). This is achieved with a very low thermal dissipation radio frequency amplifier at the STM head. The amplifier gain is higher than 40 dB and has a 50 dB maximum. Further, the AC noise figure is 0.7 dB between 100 and 1000 MHz. The noise induced in the DC amplifier is less than 2 pA RMS (root mean square), which enables the microscope to scan over soft insulating molecular layers. Thermal drift at the STM tip-sample interface is below 0.1 nm min{sup -1} both in air and in vacuum operation. Atomic resolution on highly oriented pyrolytic graphite surfaces is reliably achieved. Spin noise measurements are provided as an example of an application.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Broadband mag-noise of patterned permalloy thin films.

A Y-factor noise figure (NF) measurement method is developed to characterize high-frequency mag-noise of a 550 nm wide Permalloy strip array under different dc bias currents. The noise voltage density is obtained. The proposed lumped element transmission line model describes noise properties of the patterned Py array well. Measurement data show that rapid ferromagnetic resonance frequencies (FMR) shift induced by dc bias current is related to the excess magnetization fluctuation thermally created by the combined dc current Joule heating effects and orthogonal Oersted fields.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fully depleted CMOS pixel sensor development and potential applications

CMOS pixel sensors are often opposed to hybrid pixel sensors due to their very different sensitive layer. In standard CMOS imaging processes, a thin (about 20 μm) low resistivity epitaxial layer acts as the sensitive volume and charge collection is mostly driven by thermal agitation. In contrast, the so-called hybrid pixel technology exploits a thick (typically 300 μm) silicon sensor with high resistivity allowing for the depletion of this volume, hence charges drift toward collecting electrodes. But this difference is fading away with the recent availability of some CMOS imaging processes based on a relatively thick (about 50 μm) high resistivity epitaxial layer which allows for full depletion. This evolution extents the range of applications for CMOS pixel sensors where their known assets, high sensitivity and granularity combined with embedded signal treatment, could potentially foster breakthrough in detection performances for specific scientific instruments. One such domain is the Xray detection for soft energies, typically below 10 keV, where the thin sensitive layer was previously severely impeding CMOS sensor usage. Another application becoming realistic for CMOS sensors, is the detection in environment with a high fluence of non-ionizing radiation, such as hadron colliders. However, when considering highly demanding applications, it is still to be proven that micro-circuits required to uniformly deplete the sensor at the pixel level, do not mitigate the sensitivity and efficiency required. Prototype sensors in two different technologies with resistivity higher than 1 kΩ, sensitive layer between 40 and 50 μm and featuring pixel pitch in the range 25 to 50 μm, have been designed and fabricated. Various biasing architectures were adopted to reach full depletion with only a few volts. Laboratory investigations with three types of sources (X-rays, β-rays and infrared light) demonstrated the validity of the approach with respect to depletion, keeping a low noise figure. Especially, an energy resolution of about 400 eV for 5 keV X-rays was obtained for single pixels. The prototypes have then been exposed to gradually increased fluences of neutrons, from 10{sup 13} to 5x10{sup 14} neq/cm{sup 2}. Again laboratory tests allowed to evaluate the signal over noise persistence on the different pixels implemented. Currently our development mostly targets the detection of soft X-rays, with the ambition to develop a pixel sensor matching counting rates as affordable with hybrid pixel sensors, but with an extended sensitivity to low energy and finer pixel about 25 x 25 μm{sup 2}. The original readout architecture proposed relies on a two tiers chip. The first tier consists of a sensor with a modest dynamic in order to insure low noise performances required by sensitivity. The interconnected second tier chip enhances the read-out speed by introducing massive parallelization. Performances reachable with this strategy combining counting and integration will be detailed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 0.2–2 GHz Time-Interleaved Multistage Switched-Capacitor Delay Element Achieving 2.55–448.6 ns Programmable Delay Range and 330 ns/mm 2 Area Efficiency

Simulation of radar returns, full-duplex systems, and signal repeaters require hundreds of ns of programmable broadband radio frequency (RF) delay in the signal path to simulate large distances in the case of radar returns, for signal cancellation in full-duplex, and for isolation from reflections in signal repeaters. However, programmable broadband RF delay has been limited to ones of ns due to challenges in miniaturization with low loss and low power consumption. In this work, we present a 0.2–2 GHz digitally programmable RF delay element based on a time-interleaved multistage switched-capacitor (TIMS-SC) approach. The proposed approach enables hundreds of ns of broadband RF delay by employing sample time expansion in multiple stages of switched-capacitor storage elements. Further, the delay element was implemented in a 45 nm SOI CMOS process and achieves a 2.55–448.6 ns programmable delay range with < 0.12% delay variation across 1.8 GHz of bandwidth at maximum delay, 2.42 ns programmable delay steps, and 330 ns/mm 2 area efficiency. Through the proposed approach, the device shows minimal delay change across a -40 °C to 85 °C temperature range and < 0.25 dB gain variation across delay settings. The device achieves 26 dB gain, 7.4 dB noise figure, and consumes 74 mW from a 1 V supply with an active area of 1.36 mm 2 .

42 ENGINEERING↗

Research of 100 MHz ultra-low-jitter clock generating circuit

Jitter which quantifies the quality of a clock is an important specification. It is of great significance for an electronic system. To obtain a good signal-to-noise ratio for sampling systems, there must be clocks with low jitter performances. By using the relationship between jitter and phase noise, the 100 MHz clock generating circuit with ultra-low jitter and phase noise characteristics are studied in this paper. Bipolar junction transistor with low noise figure and low corner frequency should be selected. Inductance and capacitance in the feedback circuit are obviously the main contributions to the jitter. Impacts of the loaded quality factor (Q{sub L}) of the circuit on the jitter are analyzed, and the explicit expression for the jitter based on circuit components is derived as well. The simulation and experiment results are proved to show that the jitter and phase noise characteristics can be improved by increasing Q{sub L} of the circuit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wideband and flat-gain amplifier based on high concentration erbium-doped fibres in parallel double-pass configuration

A wideband and flat gain erbium-doped fibre amplifier (EDFA) is demonstrated using a hybrid gain medium of a zirconiabased erbium-doped fibre (Zr-EDF) and a high concentration erbium-doped fibre (EDF). The amplifier has two stages comprising a 2-m-long ZEDF and 9-m-long EDF optimised for C- and L-band operations, respectively, in a double-pass parallel configuration. A chirp fibre Bragg grating (CFBG) is used in both stages to ensure double propagation of the signal and thus to increase the attainable gain in both C- and L-band regions. At an input signal power of 0 dBm, a flat gain of 15 dB is achieved with a gain variation of less than 0.5 dB within a wide wavelength range from 1530 to 1605 nm. The corresponding noise figure varies from 6.2 to 10.8 dB within this wavelength region.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bismuth-doped fibre amplifier for the range 1300 - 1340 nm

We demonstrate the first bismuth-doped fibre amplifier operating in the second transmission window of silica-based fibres. At a pump power of 460 mW and pump wavelength of 1230 nm, its gain reaches 24.5 dB at 1320 nm, with a gain bandwidth of 37 nm, saturation power near 10 mW, and noise figure of 5 dB. (letters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Noise performance of magneto-inductive cables

Magneto-inductive (MI) waveguides are metamaterial structures based on periodic arrangements of inductively coupled resonant magnetic elements. They are of interest for power transfer, communications and sensing, and can be realised in a flexible cable format. Signal-to-noise ratio is extremely important in applications involving signals. Here, we present the first experimental measurements of the noise performance of metamaterial cables. We focus on an application involving radiofrequency signal transmission in internal magnetic resonance imaging (MRI), where the subdivision of the metamaterial cable provides intrinsic patient safety. We consider MI cables suitable for use at 300 MHz during {sup 1}H MRI at 7 T, and find noise figures of 2.3–2.8 dB/m, together with losses of 3.0–3.9 dB/m, in good agreement with model calculations. These values are high compared to conventional cables, but become acceptable when (as here) the environment precludes the use of continuous conductors. To understand this behaviour, we present arguments for the fundamental performance limitations of these cables.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗