Search NASA⌕ Search

SEARCH · Search NASA

Results for “Noise deconvolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Qubit noise deconvolution

We present a noise deconvolution technique to remove a wide class of noises when performing arbitrary measurements on qubit systems. In particular, we derive the inverse map of the most common single qubit noisy channels, and exploit it at the data processing step to obtain noise-free estimates of observables evaluated on a qubit system subject to known noise. We illustrate a self-consistency check to ensure that the noise characterization is accurate providing simulation results for the deconvolution of a generic Pauli channel, as well as experimental evidence of the deconvolution of decoherence noise occurring on Rigetti quantum hardware.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multiqubit noise deconvolution and characterization

We present a noise deconvolution technique for obtaining noiseless expectation values of noisy observables at the output of multiqubit quantum channels. For any number of qubits or in the presence of correlations, our protocol applies to any mathematically invertible noise model, even when its inverse map is not physically implementable, i.e., when it is neither completely positive nor trace preserving. For a generic observable affected by Pauli noise it provides a quadratic speedup, always producing a rescaling of its Pauli basis components. We show that it is still possible to achieve the deconvolution while experimentally estimating the noise parameters, whenever these are unknown (bypassing resource-heavy techniques such as quantum process tomography). We provide a simulation, with examples for both Pauli and non-Pauli channels.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A digital algorithm for spectral deconvolution with noise filtering and peak picking: NOFIPP-DECON

Noise-filtering, peak-picking deconvolution software incorporates multiple convoluted convolute integers and multiparameter optimization pattern search. The two theories are described and three aspects of the software package are discussed in detail. Noise-filtering deconvolution was applied to a number of experimental cases ranging from noisy, nondispersive X-ray analyzer data to very noisy photoelectric polarimeter data. Comparisons were made with published infrared data, and a man-machine interactive language has evolved for assisting in very difficult cases. A modified version of the program is being used for routine preprocessing of mass spectral and gas chromatographic data.

Edwards, T. R.↗

Optimal application of Morrison's iterative noise removal for deconvolution

Morrison's iterative method of noise removal can be applied for both noise removal alone and noise removal prior to deconvolution. This method is applied to noise of various noise levels added to determine the optimum use of the method. The phase shift method of migration and modeling is evaluated and the results are compared to Stolt's approach. A method is introduced by which the optimum iterative number for deconvolution can be found. Statistical computer simulation is used to describe the optimum use of two convergent iterative techniques for seismic data. The Always-Convergent deconvolution technique was applied to data recorded during the quantitative analysis of materials through NonDestructive Evaluation (NDE) in which ultrasonic signals were used to detect flaws in substances such as composites.

Ioup, George E.↗

Optimal application of Morrison's iterative noise removal for deconvolution. Appendices

Morrison's iterative method of noise removal, or Morrison's smoothing, is applied in a simulation to noise-added data sets of various noise levels to determine its optimum use. Morrison's smoothing is applied for noise removal alone, and for noise removal prior to deconvolution. For the latter, an accurate method is analyzed to provide confidence in the optimization. The method consists of convolving the data with an inverse filter calculated by taking the inverse discrete Fourier transform of the reciprocal of the transform of the response of the system. Various length filters are calculated for the narrow and wide Gaussian response functions used. Deconvolution of non-noisy data is performed, and the error in each deconvolution calculated. Plots are produced of error versus filter length; and from these plots the most accurate length filters determined. The statistical methodologies employed in the optimizations of Morrison's method are similar. A typical peak-type input is selected and convolved with the two response functions to produce the data sets to be analyzed. Both constant and ordinate-dependent Gaussian distributed noise is added to the data, where the noise levels of the data are characterized by their signal-to-noise ratios. The error measures employed in the optimizations are the L1 and L2 norms. Results of the optimizations for both Gaussians, both noise types, and both norms include figures of optimum iteration number and error improvement versus signal-to-noise ratio, and tables of results. The statistical variation of all quantities considered is also given.

Ioup, George E.↗

Always-Convergent Iterative Noise Removal and Deconvolution for Image Data

Linear filtering techniques currently used for the restoration of noisy, blurred or otherwise degraded image data are discussed and new techniques related to the iterative techniques of Morrison and van Cittert are developed and implemented. Programs written for the implementation are discussed in the appendices. It is shown that the new techniques are convergent for any system response function, and they are applied to the task of restoring a severely blurred image.

Ioup, G. E.↗

Determination of design and operation parameters for upper atmospheric research instrumentation to yield optimum resolution with deconvolution, appendix 3

The Always-Convergent Iterative Noise Removal and Deconvolution Method of Ioup is applied as a single-filter in the transform domain to deconvolution with both narrow and wide Gaussian impulse response functions. The wraparound error for both cases is also studied. A method is developed by which one can find the optimum iteration number for single-filter iterative deconvolution of sampled data. The method employs the mean square error (MSE), the square of the difference between the deconvolved result and the input, for optimization. The MSE decreases as the deconvolution iterations proceed, but at the optimum iteration number, the MSE starts to increase. This procedure is repeated for signal-to-noise ratio of 10 to 150. The optimum iteration number and the MSE are plotted vs SNR. By knowing the SNR for a particular experiment, one can find the optimum iteration number and MSE.

Ioup, George E.↗

Iterative and function-continuation Fourier deconvolution methods for enhancing mass spectrometer resolution

Mass spectrometer data in the form of ion current versus mass-to-charge ratio often include overlapping mass peaks, especially in low- and medium-resolution instruments. Numerical deconvolution of such data effectively enhances the resolution by decreasing the overlap of mass peaks. In this paper two approaches to deconvolution are presented: a function-domain iterative technique and a Fourier transform method which uses transform-domain function-continuation. Both techniques include data smoothing to reduce the sensitivity of the deconvolution to noise. The efficacy of these methods is demonstrated through application to representative mass spectrometer data and the deconvolved results are discussed and compared to data obtained from a spectrometer with sufficient resolution to achieve separation of the mass peaks studied. A case for which the deconvolution is seriously affected by Gibbs oscillations is analyzed.

Ioup, J. W.↗

Multi-images deconvolution improves signal-to-noise ratio on gated stimulated emission depletion microscopy

Time-gated detection, namely, only collecting the fluorescence photons after a time-delay from the excitation events, reduces complexity, cost, and illumination intensity of a stimulated emission depletion (STED) microscope. In the gated continuous-wave- (CW-) STED implementation, the spatial resolution improves with increased time-delay, but the signal-to-noise ratio (SNR) reduces. Thus, in sub-optimal conditions, such as a low photon-budget regime, the SNR reduction can cancel-out the expected gain in resolution. Here, we propose a method which does not discard photons, but instead collects all the photons in different time-gates and recombines them through a multi-image deconvolution. Our results, obtained on simulated and experimental data, show that the SNR of the restored image improves relative to the gated image, thereby improving the effective resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Convolution-based frequency domain multiplexing of SiPM readouts using the $\mathrm{DRS4}$ digitizer

Here we present 4:1 multiplexing of organic scintillators, each coupled to a silicon photomultiplier (SiPM), to reduce the need for a large number of digitizer input channels to readout highly pixelated radiation detection systems. Frequency domain multiplexing (FDM) encodes a detector pulse by assigning it a unique frequency via convolution before combining the encoded signal into a single channel. The combined signal is then read through a digitizer input channel. We have designed an FDM system to multiplex four SiPMs using DRS4 digitizer evaluation board from Paul Scherrer Institute (PSI). We demonstrate 4:1 multiplexing of the SiPM fast output signals and pulse recovery from the digitized multiplexed signal using deconvolution. The noise in the recovered pulse introduces a bias and uncertainty in the estimate of energy and timing that changes with pulse height. The relative uncertainty in the estimated energy from the recovered pulse decreases with pulse height with a maximum uncertainty of 3.1% for the low energy pulses (corresponding to 100 keV); the uncertainty in the estimated time pick-off also decreases with pulse height with a maximum uncertainty of 110 ps for the low energy pulses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DeconTools

DeconTools is a software package used for detecting features in MS data by using the isotopic signatures of expected components. The tool uses different algorithms for different parts of the deconvolution process: noise reduction, peak detection, prediction of theoretical isotopic envelope and scoring functions that quantitate the quality of signature observed in the data.

Crowell, Kevin↗

SU-E-I-08: Investigation of Deconvolution Methods for Blocker-Based CBCT Scatter Estimation

Purpose: To investigate whether deconvolution methods can improve the scatter estimation under different blurring and noise conditions for blocker-based scatter correction methods for cone-beam X-ray computed tomography (CBCT). Methods: An “ideal” projection image with scatter was first simulated for blocker-based CBCT data acquisition by assuming no blurring effect and no noise. The ideal image was then convolved with long-tail point spread functions (PSF) with different widths to mimic the blurring effect from the finite focal spot and detector response. Different levels of noise were also added. Three deconvolution Methods: 1) inverse filtering; 2) Wiener; and 3) Richardson-Lucy, were used to recover the scatter signal in the blocked region. The root mean square error (RMSE) of estimated scatter serves as a quantitative measure for the performance of different methods under different blurring and noise conditions. Results: Due to the blurring effect, the scatter signal in the blocked region is contaminated by the primary signal in the unblocked region. The direct use of the signal in the blocked region to estimate scatter (“direct method”) leads to large RMSE values, which increase with the increased width of PSF and increased noise. The inverse filtering is very sensitive to noise and practically useless. The Wiener and Richardson-Lucy deconvolution methods significantly improve scatter estimation compared to the direct method. For a typical medium PSF and medium noise condition, both methods (∼20 RMSE) can achieve 4-fold improvement over the direct method (∼80 RMSE). The Wiener method deals better with large noise and Richardson-Lucy works better on wide PSF. Conclusion: We investigated several deconvolution methods to recover the scatter signal in the blocked region for blocker-based scatter correction for CBCT. Our simulation results demonstrate that Wiener and Richardson-Lucy deconvolution can significantly improve the scatter estimation compared to the direct method.

60 APPLIED LIFE SCIENCES↗

Inner coma imaging of Comet Levy (1990c) with the Hubble Space Telescope

Observations of comet Levy were carried out with the Hubble Space Telescope (HST) on UT 27 Sep. 1990. The comet was imaged with the Wide Field Camera (WFC) through both red and blue filters, which were selected to isolate continuum emission peaking sharply at the nucleus. The longest exposures (4 sec) through the red filter had sufficient signal to noise that image deconvolution could be used to recover virtually the full spatial resolution of HST. These images reveal a fan-shaped inner coma in which the sunward-facing hemisphere is significantly brighter than the tailward hemisphere, consistent with volatile sublimation occurring primarily on the dayside of the nucleus.

Weaver, Harold A.↗

Aeroacoustic Study of a Subscale Large Civil Transport (STAR) Model – Part 2: Validation of Simulated Results

Aeroacoustic measurements of the 26%-scale, semispan Boeing 777-200 Subsonic Transport Aeroacoustic Research (STAR) model tested in the NASA Ames Research Center 40- by 80-foot wind tunnel were used to ascertain the efficacy of high-fidelity simulations to accurately predict noise from the landing gear of large commercial transports. The simulations, conducted with the lattice Boltzmann solver PowerFLOW®, used a digital replica of the STAR model with or without main landing gear deployed and slats and flaps set to their highest deflection angles to represent aircraft during landing. The computations were performed at a Mach number of 0.21, Reynolds number of 8.2 million based on the model mean aerodynamic chord, and other conditions prevalent during the STAR model test. Measured and computed surface pressures were in very good agreement at most port locations on the model, as were global force coefficients, indicating that the simulations captured the impact of main gear deployment on inboard flap loading. Noise sources produced by the main landing gear and high-lift devices were determined via source localization maps generated with CLEAN from synthetic and experimental data. In general, very good agreement between predicted and measured acoustic source location and relative strength was observed in the maps. Comparisons of far-field noise spectra obtained from the CLEAN deconvolution maps showed remarkable agreement between synthetic and experimental broadband noise at low and medium frequencies. Main landing gear sources for model-scale frequencies above 7,000 Hz could not be resolved with the spatial resolution used during the simulations.

airframe noise↗

X-ray atomic absorption of cesium and xenon in the L-edge region

X-ray absorption of atomic cesium is measured in the L-edge region, using a beryllium-window cell for cesium vapor. For comparison, absorption in Xe gas in the same energy region is remeasured with improved signal-to-noise ratio. By combining deconvolution and modeling, the edge profiles are studied to determine the threshold energies and the shape of the edge apex with exponential slope of the high-energy flank. In both elements, multielectron excitations show the same basic ordering in compact groups, largely independent of the core-hole subshell, following the energy sequence of coexcited valence and subvalence orbitals. The main effect of 6s electron in Cs, apart from 2(s,p)6s excitation, is the enhancement of single- as well as some multielectron resonant channels. The spectra of both elements show the ''polarization effect'': a convex basic curvature of the L{sub 2} and L{sub 3} segments, a concave L{sub 1} segment. Previously, Kutzner demonstrated a convincing theoretical explanation of the effect on Xe in a relativistic random-phase approximation with relaxation involving overlap integrals with continuum [Rad. Phys. Chem. 70, 95 (2004)].

74 ATOMIC AND MOLECULAR PHYSICS↗

Input-output characterization of an ultrasonic testing system by digital signal analysis

Ultrasonic test system input-output characteristics were investigated by directly coupling the transmitting and receiving transducers face to face without a test specimen. Some of the fundamentals of digital signal processing were summarized. Input and output signals were digitized by using a digital oscilloscope, and the digitized data were processed in a microcomputer by using digital signal-processing techniques. The continuous-time test system was modeled as a discrete-time, linear, shift-invariant system. In estimating the unit-sample response and frequency response of the discrete-time system, it was necessary to use digital filtering to remove low-amplitude noise, which interfered with deconvolution calculations. A digital bandpass filter constructed with the assistance of a Blackman window and a rectangular time window were used. Approximations of the impulse response and the frequency response of the continuous-time test system were obtained by linearly interpolating the defining points of the unit-sample response and the frequency response of the discrete-time system. The test system behaved as a linear-phase bandpass filter in the frequency range 0.6 to 2.3 MHz. These frequencies were selected in accordance with the criterion that they were 6 dB below the maximum peak of the amplitude of the frequency response. The output of the system to various inputs was predicted and the results were compared with the corresponding measurements on the system.

Williams, J. H., Jr.↗

The Calculation of Fractal Dimension in the Presence of Non-Fractal Clutter

The area of information processing has grown dramatically over the last 50 years. In the areas of image processing and information storage the technology requirements have far outpaced the ability of the community to meet demands. The need for faster recognition algorithms and more efficient storage of large quantities of data has forced the user to accept less than lossless retrieval of that data for analysis. In addition to clutter that is not the object of interest in the data set, often the throughput requirements forces the user to accept "noisy" data and to tolerate the clutter inherent in that data. It has been shown that some of this clutter, both the intentional clutter (clouds, trees, etc) as well as the noise introduced on the data by processing requirements can be modeled as fractal or fractal-like. Traditional methods using Fourier deconvolution on these sources of noise in frequency space leads to loss of signal and can, in many cases, completely eliminate the target of interest. The parameters that characterize fractal-like noise (predominately the fractal dimension) have been investigated and a technique to reduce or eliminate noise from real scenes has been developed. Examples of clutter reduced images are presented.

Herren, Kenneth A.↗