Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Criticality Safety Applications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Resonance Region Cross-Section Data Advancements for Nuclear Criticality Safety Applications and ENDF/B-VII.1

ORNL has completed new resonance region cross-section evaluations with covariance data to support nuclear criticality safety applications. This paper summarizes some of the most recent cross-section evaluations that have been completed and will be made available to process into nuclear data libraries for use with radiation transport codes. Specifically, the paper summarizes the work that has been completed for 35 Cl, 37 Cl, 50 Cr, 52 Cr, 53 Cr, 54 Cr, 39 K, 41 K, 19 F, 55 Mn, 58 Ni, 60 Ni, 235 U, 238 U, and 239 Pu. Many of the new cross-section evaluations are based on new differential data measurements in the resonance region. Furthermore, corresponding covariance data analyses have been performed in conjunction with the resonance evaluation effort thereby providing a consistent set of covariance data to complement the resonance region cross-section evaluations. As a result, the new cross-section evaluations with covariance data can be used to support sensitivity/uncertainty analyses for criticality safety applications.

19-F↗

Verification of MCNP6.2 for Nuclear Criticality Safety Applications

Several suites of verification/validation benchmark problems were run in early 2017 to verify that the new production release of MCNP6.2 performs correctly for nuclear criticality safety applications (NCS). MCNP6.2 results for several NCS validation suites were compared to the results from MCNP6.1 [1] and MCNP6.1.1 [2]. MCNP6.1 is the production version of MCNP® released in 2013, and MCNP6.1.1 is the update released in 2014. MCNP6.2 includes all of the standard features for NCS calculations that have been available for the past 15 years, along with new features for sensitivity-uncertainty based methods for NCS validation [3]. Results from the benchmark suites were compared with results from previous verification testing [4-8]. Criticality safety analysts should consider testing MCNP6.2 on their particular problems and validation suites. No further development of MCNP5 is planned. MCNP6.1 is now 4 years old, and MCNP6.1.1 is now 3 years old. In general, released versions of MCNP are supported only for about 5 years, due to resource limitations. All future MCNP improvements, bug fixes, user support, and new capabilities are targeted only to MCNP6.2 and beyond.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Validation of Continuous-Energy ENDF/B-VIII.0 16 O, 56 Fe, and 63,65 Cu Cross Sections for Nuclear Criticality Safety Applications

Recently completed cross-section evaluations sponsored in part by the Nuclear Criticality Safety Program were incorporated into the 2018 release of the ENDF/B-VIII.0 cross-section library. Evaluated isotopes of interest to the nuclear data and criticality safety community include 16 O, 56 Fe, and 63,65 Cu. For performance validation, benchmark models defined in the International Criticality Safety Benchmark Evaluation Project Handbook were selected based on energy-integrated k eff sensitivities to total cross sections of interest and compared with experimental values. Of the 102 benchmark configurations that were utilized, 63 are sensitive to 16 O, 32 sensitive to 63,65 Cu, and 25 sensitive to 56 Fe. Selected benchmarks were modeled in SCALE 6.2.3 Criticality Safety Analysis Sequence (CSAS) continuous-energy Monte Carlo k eff calculations with ENDF/B-VII.1, with a hybrid ENDF/B-VII.1 with ENDF/B-VIII.0 data substituted for individual isotopes of interest, and with ENDF/B-VIII.0. ENDF/B-VIII.0 showed improved agreement with experimental k eff for 56 Fe, 63 Cu, elemental copper, and full library substitution while producing lessened agreement for 16 O and 65 Cu. Furthermore, with full library and isotope-specific ENDF/B-VIII.0 performance, a best-case ENDF library was formed by excluding underperforming isotopes’ ENDF/B-VIII.0 data, reverting 16 O and 65 Cu cross sections to ENDF/B-VII.1. This resulted in the average relative deviation between calculated and experimental data improving from 1.45σ for the ENDF/B-VIII.0 library to 1.32σ for the best-case library, relative to benchmark uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved Verification and Validation Testing and Tools including Nuclear Criticality Safety Applications with the MCNP6.3® Code [Abstract]

A new Python-based framework has been developed to enable a more consistent layout with automatable setup, execution, and documentation of all verification and validation (V&V) test suites previously established for use with the MCNP code. In this paper, the new general framework for the V&V test suites is discussed, including information on all of the current capabilities and plans for future capabilities. For nuclear criticality safety applications, the existing V&V benchmark problems within the criticality, extended criticality, and analytic k-effective test suites have been ported into this new framework. In addition, the status and updates to the Rossi-alpha and subcritical multiplicationtest suites will be discussed. Some V&V results exercising new MCNP6.3 capabilities will be demonstrated.

97 MATHEMATICS AND COMPUTING↗

Verification of MCNP6.2 with ENDF/B-VIII.0 Nuclear Data for Nuclear Criticality Safety Applications

MCNP6.2 was released in 2018 and is the latest production release of MCNP ® available from RSICC. MCNP6.2 includes all of the standard features for nuclear criticality safety (NCS) calculations that have been available for the past 15 years, along with new features for sensitivity-uncertainty based methods using Whisper for NCS validation. MCNP6.2 verification using ENDF/B-VII.1 nuclear data was previously reported in. This report focuses on the initial testing and verification of MCNP6.2 using the ENDF/B-VIII.0 nuclear data that were released in 2018. The sections that follow provide guidance for NCS users on modifying existing MCNP input files to use the new ENDF/B-VIII.0 ACE nuclear data, discussion of results for several ICSBEP-based benchmark suites using MCNP6.2 with ENDF/B-VII.1 and ENDF/B-VIII.0 nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Continuous-Energy ENDF/B-VIII.0 Cross Section and SCALE 6.2.4 Performance for Nuclear Criticality Safety Applications: 1 H, C, 58,60 Ni, 182,183,184,186 W, 235,238 U, 239 Pu

As part of the nuclear data evaluation and validation cycle, the ENDF/B-VIII.0 cross-section library released in 2018 requires testing to determine areas of improvement and deterioration. Previous work by the authors investigated the performance of 16 O, 56 Fe, and 63,65 Cu cross sections, with this study acting as an extension of the prior work. In addition to the isotopes and nuclear criticality safety benchmarks of interest to the prior work, benchmarks from the International Criticality Safety Benchmark Evaluation Project Handbook were selected for their k eff sensitivity to 1 H, C, 58,60 Ni, 182,183,184,186 W, 235,238U, or 239 Pu cross sections and were modeled in the SCALE code system maintained by Oak Ridge National Laboratory. In total, 253 benchmark configurations were selected for their sensitivities and modeled using SCALE 6.2.4 Criticality Safety Analysis Sequences (CSAS) continuous-energy Monte Carlo k eff calculations. This collection includes and expands upon the 99 benchmarks in the prior work. The AMPX-processed ENDF/B-VIII.0 library was decomposed into individual ENDF/B-VIII.0 datum libraries for each isotope of interest. Doing so allowed for the individual substitution of an ENDF/B-VIII.0 cross section in the place of ENDF/B-VII.1, determining isotope-specific effects of ENDF/B-VIII.0 relative to ENDF/B-VII.1. Full library calculations with entirely ENDF/B-VII.1 data or entirely ENDF/B-VIII.0 data were also executed. As a measure of performance, the average relative deviation was determined as the ratio of the deviation between calculated and experimental keff to the propagated calculational and experimental uncertainty. With calculated full library and isotope-specific ENDF/B-VIII.0 k eff ’s, an optimized combination of data libraries was estimated and confirmed with SCALE calculations. This showed that reverting 239 Pu, 58 Ni, 16 O, and 65 Cu cross sections to ENDF/B-VII.1 resulted in improved performance relative to the full ENDF/B-VIII.0 library. Across all 253 benchmarks, the average relative deviation was 1.29σ for the full ENDF/B-VII.1 library, 1.17σ for the full ENDF/B-VIII.0 library, and 0.97σ for the optimized combination. The reversion of 239 Pu, 58 Ni, 16 O, and 65 Cu cross sections to ENDF/B-VII.1 in the 99 benchmarks of the prior work resulted in further improved experimental agreement compared to the previously reported improvement from 16 O and 65 Cu alone. Therefore, it is suggested that applications with significant sensitivities to 239 Pu, 58 Ni, 16 O, and 65 Cu consider their choice of nuclear data library.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Status of a New Resonance Evaluation for Cerium to Support Nuclear Criticality Safety Applications

A new resonance evaluation is currently being carried out at Oak Ridge National Laboratory (ORNL) for isotopes of cerium. This new evaluation will provide a much-needed update of the resolved and unresolved resonance parameters for {sup 140}Ce and {sup 142}Ce based on new and existing experimental cross section data. The physics of the resolved resonance region will be greatly improved, and new resonance parameter covariance data will be generated. Cerium exists predominately as {sup 140}Ce and {sup 142}Ce and can be found in chemical processing streams because it is used commercially as a catalyst or additive in chemical applications (e.g., glass polishing powder). Cerium has neutron-absorbing properties that can influence the reactivity of systems with fissionable material. The need for improved cerium cross section data has been identified specifically for the Hanford Plutonium Finishing Plant as part of the Nuclear Criticality Safety Program (NCSP) nuclear data request. Furthermore, cerium is a high-yield fission product, making it relevant for reactor calculations. Currently, ENDF/B-VII.1 evaluations for cerium isotopes (described in Section II) do not include the covariance data needed to support sensitivity/uncertainty analyses of systems involving cerium. In addition, the available cerium resonance parameters in ENDF/B-VII.1 are based on parameters provided in the Atlas of Neutron Resonances: Resonance Parameters and Thermal Cross- Sections. Z = 1-100 by S. Mughabghab; hence, the 'evaluated' resonance parameters are not based on a detailed R-matrix analysis. Furthermore, differential measurements are needed in the resonance region to accurately predict the neutron resonances. ORNL has completed new differential measurements on natural samples of cerium, and measurements of an enriched {sup 142}Ce sample are planned. A corresponding resonance evaluation for {sup 140}Ce and {sup 142}Ce being conducted by ORNL will provide detailed cross section resonance parameters and corresponding evaluated covariance data in the resonance region in support of the NCSP. The target uncertainty requested by the NCSP is on the order of 1-2% for the total cross section and less than 6% for the capture cross section in the resolved resonance region. New cerium resonance evaluations will significantly improve radiation transport calculations for systems involving cerium in processes in the DOE Complex. Also, the new evaluations will provide much-needed evaluated covariance data to support sensitivity/ uncertainty analyses.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Verification of the MCNP6.2 Release for Nuclear Criticality Safety Applications

MCNP6.2 was released in 2018 and is the latest production release of MCNP ® available from RSICC. Previous releases were MCNP6.1 [3] in 2013 and MCNP6.1.1 in 2014. MCNP6.2 includes all of the standard features for NCS calculations that have been available for the past 15 years, along with new features for sensitivity-uncertainty based methods using Whisper for NCS validation

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low-fidelity covariances for neutron cross sections on 57 structural and 31 heavy nuclei in the fast region

We produced a large set of neutron cross section covariances in the energy range of 5 keV-20 MeV. The present set of data on 57 structural materials and 31 heavy nuclei follows our earlier work on 219 fission product materials and completes our extensive contribution to the low-fidelity covariance project (307 materials). This project aims to provide initial, low-fidelity yet consistent estimates of covariance data for nuclear criticality safety applications. The evaluation methodology combines the nuclear reaction model code EMPIRE which calculates sensitivity to nuclear reaction model parameters, and the Bayesian code KALMAN that propagates uncertainties of the model parameters to cross sections. Taking into account the large scale of the project, only marginal reference to experimental data was made. The covariances were derived from the perturbation of several key model parameters selected by the sensitivity analysis. These parameters refer to the optical model potential, the level densities and the strength of the pre-equilibrium emission. This work represents the first attempt ever to generate nuclear data covariances on such a large scale.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nuclear Criticality Safety Program @ ORNL [Slides]

This presentation provides an overview of the Nuclear Criticality Safety Program (NCSP) and its activities at Oak Ridge National Lab, including the program's history, mission and vision, accomplishments, challenges, initiatives, and tasks, as well as information regarding ORNL's NCSP budget.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Use of InSpector{sup TM} 1 1000 Instrument with LaBr{sub 3} for Nuclear Criticality Safety (NCS) Applications at the Westinghouse Hematite Decommissioning Project (HDP) - 13132

The Westinghouse Hematite Decommissioning Project (HDP) is a former nuclear fuel cycle facility that is currently undergoing decommissioning. One aspect of the decommissioning scope is remediation of buried nuclear waste in unlined burial pits. The current Nuclear Criticality Safety program relies on application of criticality controls based on radiological setpoints from a 2 x 2 Sodium Iodide (NaI) detector. Because of the nature of the material buried (Low Enriched Uranium (LEU), depleted uranium, thorium, and radium) and the stringent threshold for application of criticality controls based on waste management (0.1 g {sup 235}U/L), a better method for {sup 235}U identification and quantification has been developed. This paper outlines the early stages of a quick, in-field nuclear material assay and {sup 235}U mass estimation process currently being deployed at HDP. Nuclear material initially classified such that NCS controls are necessary can be demonstrated not to require such controls and dispositioned as desired by project operations. Using Monte Carlo techniques and a high resolution Lanthanum Bromide (LaBr) detector with portable Multi-Channel Analyzer (MCA), a bounding {sup 235}U mass is assigned to basic geometries of nuclear material as it is excavated. The deployment of these methods and techniques has saved large amounts of time and money in the nuclear material remediation process. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Considerations for a New Solution Reactor for Nuclear Criticality Safety Applications-a White Paper

This document presents considerations for a new solution reactor as noted in the United States (US) Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP) Five Year Plan. The solution reactor tasking is noted in collaboration with the French Institut de Radioprotection et de Sûreté Nucléaire (IRSN). This document presents General Considerations (GC) and Specific Considerations (SC) that support the GCs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Verification of MCNP5-1.60 and MCNP6-Beta-2 for Criticality Safety Applications

To verify that both MCNP5-1.60 and MCNP6-Beta-2 are performing correctly for criticality safety applications, several suites of verification/validation benchmark problems were run in early 2012. Results from these benchmark suites were compared with results from previously verified versions of MCNP5. The goals of this verification testing were: (1) Verify that MCNP5-1.60 works correctly for nuclear criticality safety applications, producing the same results as for the previous verification performed in 2010; (2) Determine the sensitivity to computer roundoff using different Fortran-90 compilers for building MCNP5 and MCNP6, to support moving to current versions of the compilers; and (3) Verify that MCNP6-Beta-2 works correctly for nuclear criticality safety applications, producing the same results as for MCNP5-1.60. This provides support for eventual migration of users and applications to MCNP6. The current production version of MCNP5 included in the RSICC release package is MCNP5-1.60. This version was first distributed by RSICC in October 2010. While there were subsequent RSICC distributions of the MCNP package in July 2011 and February 2012, no changes were made to MCNP5-1.60. The RSICC release package in February 2012 included both MCNP5-1.60 and the current beta version of MCNP6, MCNP6-Beta-2. MCNP6 is the merger of MCNP5 and MCNPX capabilities. The current release of MCNP6 available from RSICC as of February 2012 is MCNP6-Beta-2. This version includes all of the features for criticality safety calculations that are available in MCNP5-1.60, and many new features largely unrelated to nuclear criticality safety calculations. This release is a 'beta' release to allow intermediate and advanced users to begin testing the merged code in their field of expertise. It should not be used for production calculations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Nuclear Data Adjustment with Whisper for Criticality Safety Applications [Slides]

Nuclear data adjustment is used by Whisper to compute residual nuclear data uncertainties within a full suite of benchmarks; in order to do so, a complete set of nuclear data covariances, benchmarks and k-effective sensitivity profiles (for both benchmarks and applications) is required. For applications that are similar to the full benchmark suite, the residual uncertainties add a small margin to the overall USL calculation. For applications that are dissimilar to the full benchmark suite, the residual uncertainties add a reasonable margin to the overall USL calculation (more conservative). This methodology helps to overcome any issues in the released covariance libraries where nuclear data uncertainties appear to be too large.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗