Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear physics instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Feasibility study of a compact neutron resonance transmission analysis instrument

Neutron Resonance Transmission Analysis (NRTA) uses resonant absorption of neutrons to infer the absolute isotopic composition of a target object, enabling applications in a broad range of fields such as archaeology, enrichment analysis of nuclear fuel, and arms control treaty verification. In the past, NRTA involved large user facilities and complex detector systems. However, recent advances in the intensity of compact neutron sources have made compact neutron imaging designs increasingly feasible. This work describes the Monte Carlo (MC) based design of a compact epithermal NRTA radiographic instrument which uses a moderated, compact deuterium-tritium (DT) neutron source and an epithermal neutron detector. Such an instrument would have a wide range of applications, and would be especially impactful for such scenarios as nuclear inspection and arms control verification exercises, where system complexity and mobility may be of critical importance. The MC simulations presented in this work demonstrate accurate time-of-flight (TOF) reconstructions for transmitted neutron energies, capable of differentiating isotopic compositions of nuclear material with high levels of accuracy. A new generation of miniaturized and increasingly more intense neutron sources will allow this technique to achieve measurements with greater precision and speed, with significant impact on a variety of engineering and societal problems.

47 OTHER INSTRUMENTATION↗

CsI calorimeter for the J-PARC KOTO experiment

An electromagnetic calorimeter made of undoped CsI crystals is used in the J-PARC KOTO experiment to search for new physics beyond the standard model with the KL → π 0 νν¯ decay. The calorimeter is designed to operate in vacuum of 0.1 Pa and in a high-rate environment where the counting rate due to KL decays is O(100) kHz. A special method to calibrate the calorimeter during the data taking without using a tracking system for charged particles is reported. The energy, position, and timing resolutions of the calorimeter were evaluated in several beam tests, and the resolutions satisfy the required performance. Finally, the energy resolution with the total energy E is 0.66 ⊕ 1.81/ √ E[GeV]% in the inner region of the calorimeter.

47 OTHER INSTRUMENTATION↗

New segmented target for studies of neutron unbound systems

The study of neutron-unbound systems using invariant mass spectroscopy is often performed using low-intensity radioactive ion beams. Low reaction yields can be countered by using thick targets but at the expense of larger uncertainties in the reconstructed invariant mass. In this work, we present a new segmented target designed to address this trade-off. It is composed of three mm thick passive beryllium targets interleaved between four thick position sensitive silicon detectors. In the first experiment to use this new system the half-life of two-neutron unbound was measured to be (stat) (syst) ps, which agrees with a previous measurement made by the MoNA Collaboration.

47 OTHER INSTRUMENTATION↗

Strip sensor performance in prototype modules built for ATLAS ITk

ATLAS experiment is preparing an upgrade of its detector for High-Luminosity LHC (HL-LHC) operation. The upgrade involves installation of the new all-silicon Inner Tracker (ITk). In the context of the ITk preparations, more than 80 strip modules were built with prototype barrel sensors. They were tested with electrical readout on a per-channel basis. In general, an excellent performance was observed, consistent with previous ASIC-level and sensor-level tests. However, the lessons learned included two phenomena important for the future phases of the project. First was the need to store and test the modules in a dry environment due to humidity sensitivity of the sensors. The second was an observation of high noise regions for 2 modules. The high noise regions were tested further in several ways, including monitoring the performance as a function of time and bias voltage. Additionally, direct sensor-level tests were performed on the affected channels. The inter-strip resistance and bias resistance tests showed low values, indicating a temporary loss of the inter-strip isolation. A subsequent recovery of the noise performance was observed. Here we present the test details, an analysis of how the inter-strip isolation affects the module noise, and the relationship with sensor-level quality control tests.

47 OTHER INSTRUMENTATION↗

High-Density Implosions on OMEGA and the National Ignition Facility (NIF) (Final FY23 report for the subcontract B656484 (formerly B640112))

This final FY23 report for the subcontract B656484 (formerly B640112) “High-Density Implosions on Omega and the National Ignition Facility (NIF)” summarizes MIT’s support of LLNL experiments at OMEGA and the NIF with nuclear diagnostics, platforms and analysis, and of training PhD students. Overall, the tasks identified as Statement-Of-Work (SOW) items for FY23 were accomplished.

42 ENGINEERING↗

A large angle beamstrahlung monitor for EIC

This work presents a feasibility study for a Large Angle Beamstrahlung Monitor (LABM) at EIC. We show the results of a simulation used to calculate the beamstrahlung rates and how these rates are related to mismatches of the beams. Finally, we present the design of the LABM, discuss the results, and how to successfully employ the LABM at EIC.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Steady-State Irradiation of Characterized Instruments for Nuclear Thermal Rockets Using In-Pile Experiment Apparatus

The development of nuclear rocket technology is critical for further exploration of extra-terrestrial bodies. Nuclear rockets can provide various advantages over current chemical rockets. However, the harsh environment provides several challenges regarding instrument performance. Temperature extremes, radiation (reactor and space), and the inability to conduct traditional maintenance activities can lead to severe degradation in instrument performance. To better understand the effects of radiation on instrumentation, an irradiation campaign has been designed to test a set of instruments provided by a collaborator in the aerospace industry. Details concerning instrument performance before and after irradiation are provided to allow for an analysis of the tested instruments. Additionally, the design of the irradiation test is described in detail.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton damage in (Y,Lu,Gd) 3 (Al,Ga) 5 O 12 :Ce mixed garnet scintillators

Scintillators are vital components for nuclear instrumentation and its applications, including plasma diagnostics and imaging. As yields in controlled fusion experiments increase, the radiation tolerance of scintillator candidates for use in instrumentation is of particular importance. High radiation exposure can damage scintillating materials and alter the optical properties. The effects of radiation damage in Ce-doped mixed garnet ceramics over the compositional range (Y,Gd,Lu) 3 (Al,Ga) 5 O 12 are investigated using optical techniques. The samples were exposed to 200 keV protons to an accumulated fluence of 10 16 protons per square centimeter, then characterized using diffuse reflectance spectroscopy (DRS). DRS with visible light can assess the radiation tolerance of opaque poly-crystalline samples, which can be easily sintered from powders and thus offer distinct advantages in characterization compared to single crystals. Qualitative trends in induced absorption are presented as a function of composition, and the ideal cerium dopant concentration for Y 2 LuAl 5 O 12 is determined to be 0.60–0.75 mol.%.

47 OTHER INSTRUMENTATION↗

Automated Bayesian high-throughput estimation of plasma temperature and density from emission spectroscopy

Here, this paper introduces a novel approach for automated high-throughput estimation of plasma temperature and density using atomic emission spectroscopy, integrating Bayesian inference with sophisticated physical models. We provide an in-depth examination of Bayesian methods applied to the complexities of plasma diagnostics, supported by a robust framework of physical and measurement models. Our methodology is demonstrated using experimental observations in the field of magneto-inertial fusion, focusing on individual and sequential shot analyses of the Plasma Liner Experiment at LANL. The results demonstrate the effectiveness of our approach in enhancing the accuracy and reliability of plasma parameter estimation and in using the analysis to reveal the deep hidden structure in the data. This study not only offers a new perspective of plasma analysis but also paves the way for further research and applications in nuclear instrumentation and related domains.

Bayesian inference↗

Radiation campaign of HPK prototype LGAD sensors for the High-Granularity Timing Detector (HGTD)

In this work, we report on the results of a radiation campaign with neutrons and protons of Low Gain Avalanche Detectors (LGAD) produced by Hamamatsu (HPK) as prototypes for the High-Granularity Timing Detector (HGTD) in ATLAS. Sensors with an active thickness of were irradiated in steps of roughly 2 up to a fluence of 3. As a function of the fluence, the collected charge and time resolution of the irradiated sensors will be reported for operation at °C.

47 OTHER INSTRUMENTATION↗

The new Batch Mode Ion Source for stand-alone operation at the Facility for Rare Isotope Beams (FRIB)

Gas stoppers have been used for a long-standing successful science program at Michigan State University with stopped and rare-isotope beams produced by projectile fragmentation. The National Superconducting Cyclotron Laboratory’s Coupled Cyclotron Facility has recently transitioned into the Facility for Rare Isotope Beams (FRIB) laboratory to provide rare isotopes using a high-power superconducting linear accelerator and new production facilities. To allow the science program with stopped and reaccelerated beams to continue during the transition period, a stand-alone capability was added. The Batch Mode Ion Source (BMIS) was built and has been providing beams of long-lived and stable isotopes of a variety of elements for successful user experiments. Finally, the BMIS system is described and results from the production of various beams are presented.

47 OTHER INSTRUMENTATION↗

Layout and performance of HPK prototype LGAD sensors for the High-Granularity Timing Detector

The High-Granularity Timing Detector is a detector proposed for the ATLAS Phase II upgrade. The detector, based on the Low-Gain Avalanche Detector (LGAD) technology, will cover the pseudo-rapidity region of 2.4 < |n| < 4.0 with two end caps on each side and a total area of 6.4 m 2 . The timing performance can be improved by implanting an internal gain layer that can produce signals with a fast rising edge. It significantly improves the signal-to-noise ratio. The required average timing resolution per track for a minimum ionizing particle is 30 ps at the start and 50 ps at the end of the HL-LHC operation. This is achieved with several layers of LGAD. The innermost region of the detector would accumulate a 1MeV neutron-equivalent fluence up to 2.5 10 15 n eq /cm 2 including a safety factor of 1.5 before being replaced during the scheduled shutdowns. The addition of this new detector is expected to play an important role in the mitigation of high pile-ups at the HL-LHC. The layout and performance of the various versions of LGAD prototypes produced by Hamamatsu (HPK) have been studied by the ATLAS Collaboration. The breakdown voltages, depletion voltages, inter-pad gaps, collected charge as well as the time resolution have been measured and the production yield of large size sensors has been evaluated.

47 OTHER INSTRUMENTATION↗

Effects of trapped charge on the signal formation and detection efficiency for subsequent pulses in irradiated silicon sensors

Envisaged high energy physics experiments like the Future Circular Collider require unprecedented radiation hardness of the detectors, as well as short readout time due to high luminosity and occupancy. Silicon has proven to be extremely radiation hard. Sufficient signals can be recorded even at fluences close to 1 ∙ 1 0 16 n e q / cm 2 . Here, the signal formation was studied in silicon strip sensors, irradiated and annealed until the phenomenon of charge multiplication occurred. ATLAS12EC R0 mini sensors were tested by means of edge TCT measurements at temperatures around –20 °C. It was observed that the detection of subsequent signals separated up to several microseconds is altered by the charge trapped during the preceding pulses. The effects of trapped charge on the electrical configuration of a sensor are well known as a polarization or pumping effect in larger band-gap materials like diamond, but is often neglected for silicon at this relatively high temperature. The investigation of the effect created by trapped charges in silicon sensors using subsequent pulses allows to gain information on important parameters such as de-trapping times. Furthermore, it shows a severe impact on the sensor performance in a pile-up scenario. The irradiation fluence and hence the effective doping concentration, the temperature and the amount of initially created charge have a large impact on this phenomenon. The measurements presented help to characterize this phenomenon; particular attention was paid to the application point of view.

47 OTHER INSTRUMENTATION↗

Enhanced tensor polarization in solid-state targets

In this work, we report measurements of enhanced tensor polarization on solid-state targets. The results here represent an increase in tensor polarization over that previously achieved in high energy and nuclear scattering experiments that focused on the measurement of tensor polarized observables. Enhancement techniques are used which require RF produced close to the Larmor frequency of the target spins and use selective semi-saturation resulting from two sources of irradiation, microwave for the DNP process and the additional RF used to manipulate the population of the energy levels in the target material. The spin dynamics of the solid target are used to align the spins enhancing the ensemble average to improve the figure of merit of the scattering experiment. Target rotation at an optimized rate can lead to additional enhancement by applying selective semi-saturation in polycrystalline materials that possess a Pake doublet in their NMR signal.

47 OTHER INSTRUMENTATION↗