Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear speckles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Myths of nuclear graphite in World War II, with original translations

We re-examine a common narrative that experimental errors by Walther Bothe in 1941 led Germany to abandon graphite as a reactor moderator during World War II. Using document-based nuclear archaeology, we first show that both American and German scientists used an incorrect carbon scattering cross section, thereby undermining the accuracy of all wartime data, including their conclusions on carbon’s absorption. Moreover, we argue that the availability of exceptionally pure petroleum coke in the United States, rather than any academic breakthrough, decisively enabled their production of nuclear-grade graphite. In contrast, Bothe’s Siemens electrographite had more boron contamination than any graphites considered in Fermi’s experiments, rendering it genuinely impractical as a moderator. By reframing the decision to eschew graphite as a deliberate decision rather than a mere experimental oversight, we believe the German decision was a rational consequence of material constraints and wartime priorities.

42 ENGINEERING↗

Incoherent diffractive dijet production and gluon Bose enhancement in the nuclear wave function

We investigate the effect of gluon Bose enhancement in the nuclear wave function on the dijet production in incoherent diffractive processes in DIS and ultraperipheral collisions. We demonstrate that Bose enhancement leads to an enhancement of diffractive dijet production cross section when the transverse momenta of the two jets are aligned at zero relative angle. This enhancement is maximal when the magnitude of the transverse momenta of the two jets are equal, and disappears rather quickly as a function of the ratio of the two momenta. We study both the dilute limit and fully nonlinear dense regime where the nuclear wave function is evolved with the leading order JIMWLK equation. In both cases we observe a visible effect, with it being enhanced by the evolution due to the dynamical generation of the color neutralization scale.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Coherent γ *-nucleus scattering and coherent nuclear states

In the context of a McLerran-Venugopalan (MV) model for a large nucleus, coherent scattering of a virtual photon on that nucleus is evaluated in the A − = 0 gauge, the gauge appropriate for the target nucleus. The evaluation of the scattering in A − = 0 gauge is very intricate compared to the usual A + = 0 gauge evaluation natural for the scattering process, but has the advantage of directly giving the scattering in terms of a partonic description of the nucleus. In the limit where a tagged forward jet puts the dipole-nucleus scattering in the saturation regime the coherent reactions are equal to the inelastic reactions. In terms of the nuclear wave function the coherent reactions come from color singlet and zero total transverse momentum quark-antiquark pairs in the wave function and in the saturation regime the nuclear wave function is a coherent state for these pairs. In the saturation region half of all quarks (or antiquarks) come from zero momentum and color charge pairs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis strategy for ultrafast X-ray photon correlation spectroscopy

We explain an analysis strategy for ultrafast X-ray photon correlation spectroscopy, a technique enabled by X-ray free electron lasers to probe nano- and atomic-scale dynamics in complex systems on nanosecond timescales or faster. Central to the technique is the methodology for extracting contrast in coherent X-ray diffraction patterns, known as speckle patterns. Guided by simulations, we analyze common challenges and examine errors encountered in contrast extraction. A method for accurately determining contrast amid shot noise across a wide range of count rates is presented.

36 MATERIALS SCIENCE↗

Broad sterile neutrinos & the reactor/gallium tension

Significant evidence exists for the apparent disappearance of electron-type neutrinos in radioactive source experiments. Yet, interpreted within the standard ‘3+1 sterile neutrino scenario’, precision short-baseline measurements of electron antineutrinos from nuclear reactors strongly disagree with these results. Recently, it has been demonstrated that allowing for a finite wavepacket size for the reactor neutrinos can ameliorate such a tension, however the smallness of the required wavepackets is a subject of intense debate. In this work, we demonstrate that a ‘broad’ sterile neutrino may relax this tension in much the same way. Such a phenomenological possibility can arise in plausible hidden sector scenarios, such as a clockwork-style sector, for which we provide a concrete microscopic model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Accurate contrast determination for X-ray speckle visibility spectroscopy

X-ray speckle visibility spectroscopy using X-ray free-electron lasers has long been proposed as a probe of fast dynamics in noncrystalline materials. In this paper, numerical modeling is presented to show how the data interpretation of visibility spectroscopy can be impacted by the nonidealities of real-life X-ray detectors. Using simulated detector data, this work provides a detailed analysis of the systematic errors of several contrast extraction algorithms in the context of low-count-rate X-ray speckle visibility spectroscopy and their origins are discussed. Here, it was found that the finite detector charge cloud and pixel size lead to an unavoidable `degeneracy' in photon position determination, and that the contrasts extracted using different algorithms can all be corrected by a simple linear model. The results suggest that experimental calibration of the correction coefficient at the count rate of interest is possible and essential. This allows computationally lightweight algorithms to be implemented for on-the-fly analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Real-time X-ray phase-contrast imaging using SPINNet—a speckle-based phase-contrast imaging neural network

X-ray phase-contrast imaging has become indispensable for visualizing samples with low absorption contrast. In this regard, speckle-based techniques have shown significant advantages in spatial resolution, phase sensitivity, and implementation flexibility compared with traditional methods. However, the computational cost associated with data inversion has hindered their wider adoption. By exploiting the power of deep learning, we developed a speckle-based phase-contrast imaging neural network (SPINNet) that significantly improves the imaging quality and boosts the phase retrieval speed by at least 2 orders of magnitude compared to existing methods. To achieve this performance, we combined SPINNet with a coded-mask-based technique, an enhanced version of the speckle-based method. Using this scheme, we demonstrate the simultaneous reconstruction of absorption and phase images on the order of 100 ms, where a traditional correlation-based analysis would take several minutes even with a cluster. In addition to significant improvement in speed, our experimental results show that the imaging and phase retrieval quality of SPINNet outperform existing single-shot speckle-based methods. Furthermore, we successfully demonstrate SPINNet application in x-ray optics metrology and 3D x-ray phase-contrast tomography. Our result shows that SPINNet could enable many applications requiring high-resolution and fast data acquisition and processing, such as in situ and in operando 2D and 3D phase-contrast imaging and real-time at-wavelength metrology and wavefront sensing.

36 MATERIALS SCIENCE↗

Speckle contrast of interfering fluorescence X-rays

With the development of X-ray free-electron lasers (XFELs), producing pulses of femtosecond durations comparable with the coherence times of X-ray fluorescence, it has become possible to observe intensity–intensity correlations due to the interference of emission from independent atoms. This has been used to compare durations of X-ray pulses and to measure the size of a focused X-ray beam, for example. Here it is shown that it is also possible to observe the interference of fluorescence photons through the measurement of the speckle contrast of angle-resolved fluorescence patterns. Speckle contrast is often used as a measure of the degree of coherence of the incident beam or the fluctuations of the illuminated sample as determined from X-ray diffraction patterns formed by elastic scattering, rather than from fluorescence patterns as addressed here. Commonly used approaches to estimate speckle contrast were found to suffer when applied to XFEL-generated fluorescence patterns due to low photon counts and a significant variation of the excitation pulse energy from shot to shot. A new method to reliably estimate speckle contrast under such conditions, using a weighting scheme, is introduced. The method is demonstrated by comparing the speckle contrast of fluorescence observed with pulses of 3 fs to 15 fs duration.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Focusing a round coherent beam by spatial filtering the horizontal source

This paper illustrates the use of spatial filtering with a horizontal slit near the source to enlarge the horizontal coherence in an experimental station and produce a diffraction-limited round focus at an insertion device beamline for X-ray photon correlation spectroscopy experiments. Simple expressions are provided to guide the optical layout, and wave propagation simulations confirm their applicability. The two-dimensional focusing performance of Be compound refractive lenses to produce a round diffraction-limited focus at 11 keV capable of generating a high-contrast speckle pattern of an aerogel sample is demonstrated. The coherent scattering patterns have comparable speckle sizes in both horizontal and vertical directions. The focal spot sizes are consistent with hybrid ray-tracing calculations. Producing a two-dimensional focus on the sample can be helpful to resolve speckle patterns with modern pixel array detectors with high visibility. This scheme has now been in use since 2019 for the 8-ID beamline at the Advanced Photon Source, sharing the undulator beam with two separate beamlines, 8-ID-E and 8-ID-I at 7.35 keV, with increased partially coherent flux, reduced horizontal spot sizes on samples, and good speckle contrast.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mechanical failure of fresh nuclear grade iron–chromium–aluminum (FeCrAl) cladding under simulated hot zero power reactivity initiated accident conditions

The reactivity initiated accident (RIA) is a postulated accident in light water reactors initiated by a rapid increase in reactivity which causes an increase in fission rate and fuel temperature. One potential mode of fuel system failure during RIA is pellet cladding mechanical interaction (PCMI) due to the rapid thermal expansion of the fuel pellet. Simulated PCMI experiments were performed by rapidly pressurizing iron-chromium-aluminum (FeCrAl) cladding tube samples using a hydraulic modified burst test system, causing the specimens to burst under a biaxial loading path. Deformation and rupture of the specimens were tracked with a telecentric lens and high-speed camera system. Outer surface strains were calculated using digital image correlation (DIC) on speckle patterns painted on the specimens’ outer surfaces. Experiments were conducted at approximately 275 °C, representative of hot zero power RIA conditions. The failure hoop strain was DIC-calculated between approximately 1.8–3.4%, corresponding to quasi-static energy depositions of approximately 110–260 calories per gram UO 2 assuming initial pellet-cladding contact. These conditions are very similar to the proposed energy deposition limit of 150 calories per gram UO 2 for unirradiated zirconium-based cladding in US Nuclear Regulatory Commission (NRC) Draft Regulatory Guide 1327. A very small strain rate dependence was observed in the data, with the magnitude of the failure hoop strain decreasing slightly with increasing strain rate. This observed dependence may be relevant because the FeCrAl cladding strain rate will be approximately 20% higher than in zirconium-based cladding due to the harder neutron spectrum and resultant shorter neutron generation time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Extraction of Vibration Data with Imaging

To date, the primary sensing technology used to measure the vibration response has been accelerometers and strain gages mounted directly to the structure and using either wired or, more recently, wireless telemetry. Cost issues with these sensors and the associated data acquisition systems typically limit the numbers that are deployed on in situ structures. Although there are a few structures with larger sensing counts that in some cases exceed over 1000 sensors, more typical numbers range from ten to one hundred sensors resulting in low spatial resolution when they are applied to physically large systems. When one considers that nuclear power plant structures usually have complex geometries, material properties, connectivity and boundary conditions, it is clear these current approaches to vibration measurements can only provide limited information about a system’s dynamics response characteristics. As an alternative, many non-contact measurement technologies have emerged, including point wise measurement methods such as Global Positioning System (GPS), microwave interferometry, and laser Doppler vibrometry (LDV), as well as simultaneous full-field measurement methods such as electronic speckle pattern interferometry, holography interferometry, and muon tomography, some of which can provide high spatial resolution measurements. Among these methods, digital video imaging techniques have emerged as a feasible solution for full-field vibration measurements that provide significantly more detailed dynamic response information because every pixel becomes a measurement point. Furthermore, recent advances in image processing and computer vision algorithms have been successfully used to process video data for experimental and operational modal analysis. Such full-field measurements have the potential to significantly improve many current structural assessment procedures including system identification (modal parameter estimation), structural health monitoring, load reconstruction, model validation, and model updating. Furthermore, more recent full-field imaging techniques can be accomplished with relatively low-cost, commercially-available off-the-shelf cameras. However, these measurement procedures have other limitations that must be considered such as the ability to only measure visibly accessible points on a structure and a more limited dynamic range and bandwidth than can be achieved with accelerometers or strain gages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Speckle correlation as a monitor of X-ray free-electron laser induced crystal lattice deformation

X-ray free-electron lasers (X-FELs) present new opportunities to study ultrafast lattice dynamics in complex materials. While the unprecedented source brilliance enables high fidelity measurement of structural dynamics, it also raises experimental challenges related to the understanding and control of beam-induced irreversible structural changes in samples that can ultimately impact the interpretation of experimental results. This is also important for designing reliable high performance X-ray optical components. In this work, X-FEL beam-induced lattice alterations are investigated by measuring the shot-to-shot evolution of near-Bragg coherent scattering from a single crystalline germanium sample. It is shown that X-ray photon correlation analysis of sequential speckle patterns measurements can be used to monitor the nature and extent of lattice rearrangements. Additionally, abrupt, irreversible changes are observed following intermittent high-fluence monochromatic X-ray pulses, thus revealing the existence of a threshold response to X-FEL pulse intensity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SCExAO/MEC and CHARIS Discovery of a Low-mass, 6 au Separation Companion to HIP 109427 Using Stochastic Speckle Discrimination and High-contrast Spectroscopy

We report the direct imaging discovery of a low-mass companion to the nearby accelerating A star, HIP 109427, with the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument coupled with the Microwave Kinetic Inductance Detector Exoplanet Camera (MEC) and CHARIS integral field spectrograph. CHARIS data reduced with reference star point spread function (PSF) subtraction yield 1.1–2.4 μm spectra. MEC reveals the companion in Y and J band at a comparable signal-to-noise ratio using stochastic speckle discrimination, with no PSF subtraction techniques. Combined with complementary follow-up L {sub p} photometry from Keck/NIRC2, the SCExAO data favors a spectral type, effective temperature, and luminosity of M4–M5.5, 3000–3200 K, and log{sub 10}(L/L{sub ⊙})=−2.28{sub −0.04}{sup +0.04}, respectively. Relative astrometry of HIP 109427 B from SCExAO/CHARIS and Keck/NIRC2, and complementary Gaia–Hipparcos absolute astrometry of the primary favor a semimajor axis of 6.55{sup +3.0} {sub −0.48} au, an eccentricity of 0.54{sub −0.15}{sup +0.28}, an inclination of 66.7{sub −14}{sup +8.5} degrees, and a dynamical mass of 0.280{sub −0.059}{sup +0.18} M {sub ⊙}. This work shows the potential for extreme AO systems to utilize speckle statistics in addition to widely used postprocessing methods to directly image faint companions to nearby stars near the telescope diffraction limit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase-shift speckle-shearing interferometry

We have numerically simulated the process of measuring stress – strain states by the method of speckle-shearing interferometry using the phase-shift technique. A computer model with the possibility of setting its strain and roughness is developed, which includes a model of a diffusely reflecting test object corresponding to the characteristics of a real membrane, as well as a speckle interferometer model that allows speckle interferograms to be obtained for different speckle sizes and angles between interfering beams. The process of reconstructing the object surface topogram from model speckle interferograms by the phase-shift technique is implemented. Using the developed models, a two-dimensional shearogram are obtained, which is a derivative of the strain field of a circular membrane. Comparison of the results of numerical simulation with experimental data shows that the differences (rms deviations) do not exceed 0.02 μm. It is also shown that the error of interferogram reconstruction by the phase-shift technique increases significantly when the test object strains exceed 12 μm. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TIC 168789840: A Sextuply Eclipsing Sextuple Star System

We report the discovery of a sextuply eclipsing sextuple star system from TESS data, TIC 168789840, also known as TYC 7037-89-1, the first known sextuple system consisting of three eclipsing binaries. The target was observed in Sectors 4 and 5 during Cycle 1, with lightcurves extracted from TESS Full Frame Image data. It was also previously observed by the WASP survey and ASAS-SN. The system consists of three gravitationally bound eclipsing binaries in a hierarchical structure of an inner quadruple system with an outer binary subsystem. Follow-up observations from several different observatories were conducted as a means of determining additional parameters. The system was resolved by speckle interferometry with a 0.″42 separation between the inner quadruple and outer binary, inferring an estimated outer period of ∼2 kyr. It was determined that the fainter of the two resolved components is an 8.217 day eclipsing binary, which orbits the inner quadruple that contains two eclipsing binaries with periods of 1.570 days and 1.306 days. Markov Chain Monte Carlo (MCMC) analysis of the stellar parameters has shown that the three binaries of TIC 168789840 are “triplets,” as each binary is quite similar to the others in terms of mass, radius, and T {sub eff}. As a consequence of its rare composition, structure, and orientation, this object can provide important new insight into the formation, dynamics, and evolution of multiple star systems. Future observations could reveal if the intermediate and outer orbital planes are all aligned with the planes of the three inner eclipsing binaries.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Speckle Imaging Characterization of Radial Velocity Exoplanet Systems

We conducted speckle imaging observations of 53 stellar systems that were members of long-term radial velocity (RV) monitoring campaigns and exhibited substantial accelerations indicative of planetary or stellar companions in wide orbits. Our observations were made with blue and red filters using the Differential Speckle Survey Instrument at Gemini-South and the NN-Explore Exoplanet Stellar Speckle Imager at the WIYN telescope. The speckle imaging identifies eight luminous companions within 2″ of the primary stars. In three of these systems—HD 1388, HD 87359, and HD 104304—the properties of the imaged companion are consistent with the RV measurements, suggesting that these companions may be associated with the primary and the cause of the RV variation. For all 53 stellar systems, we derive differential magnitude limits (i.e., contrast curves) from the imaging. We extend this analysis to include upper limits on companion mass in systems without imaging detections. In 25 systems, we rule out companions with masses greater than 0.2 M {sub ⊙}, suggesting that the observed RV signals are caused by late-M dwarfs or substellar (potentially planetary) objects. On the other hand, the joint RV and imaging analysis almost entirely rules out planetary explanations of the RV signal for HD 19522 and suggests that the companion must have an angular separation below a few tenths of an arcsecond. This work highlights the importance of combined RV and imaging observations for characterizing the outer regions of nearby planetary systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Orbits and Masses of Binaries from Speckle Interferometry at SOAR

We present results from Speckle inteferometric observations of 15 visual binaries and one double-line spectroscopic binary, carried out with the HRCam Speckle camera of the SOAR 4.1 m telescope. These systems were observed as a part of an on-going survey to characterize the binary population in the solar vicinity, out to a distance of 250 pc. We obtained orbital elements and mass sums for our sample of visual binaries. The orbits were computed using a Markov Chain Monte Carlo algorithm that delivers maximum likelihood estimates of the parameters, as well as posterior probability density functions that allow us to evaluate their uncertainty. Their periods cover a range from 5 yr to more than 500 yr; and their spectral types go from early A to mid M, implying total system masses from slightly more than 4M{sub ⊙} down to 0.2M {sub ⊙}. They are located at distances between approximately 12 and 200 pc, mostly at low Galactic latitude. For the double-line spectroscopic binary YSC8, we present the first combined astrometric/radial-velocity orbit resulting from a self-consistent fit, leading to individual component masses of 0.897 ± 0.027 M {sub ⊙} and 0.857 ± 0.026 M {sub ⊙}; and an orbital parallax of 26.61 ± 0.29 mas, which compares very well with the Gaia DR2 trigonometric parallax (26.55 ± 0.27 mas). In combination with published photometry and trigonometric parallaxes, we place our objects on an H-R diagram and discuss their evolutionary status. We also present a thorough analysis of the precision and consistency of the photometry available for them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The SparkPix-S ASIC for the sparsified readout of 1 MHz frame-rate X-ray cameras at LCLS-II: pixel design and simulation results

Exploiting the “sparse” nature of the information in XPCS (X-ray Photon Correlation Spectroscopy) and XSVS (Speckle Visibility Spectroscopy) experiments, we present the SparkPix-S, a 3-sides buttable Application Specific Integrated Circuit (ASIC) based on a sparsified readout strategy for large-format hybrid detectors. The SparkPix-S architecture, based on the successful ePix family, will be composed as follows: a front-end 2-D matrix of 384×352 square pixels with 50 µm pitch is arranged to match the dimensions of a PIN Si-sensor matrix; charge readout, signal shaping and amplitude discrimination is performed at pixel-level, by means of a low-power (<18 µW) analog processor, which, in case of an event, negotiates access to an analog bus placed every other column; on the chip periphery (balcony), the information on each bus is digitized by an array of successive approximation analog-to-digital converters (SAR-ADCs) running at 10 Msps; on the digital back-end the global logic will generate the output data stream using low-voltage differential signalling (LVDS). A first prototype of the SparkPix-S, with a reduced matrix size of 96×96 pixels, is currently under production on a 130 nm CMOS technology. Simulated performance results show an equivalent noise charge <60 el. r.m.s. at 1 MHz repetition rate, with a maximum input energy of 60 keV and capability to discriminate charge signals with equivalent energy as low as 900 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗