Search NASA⌕ Search

SEARCH · Search NASA

Results for “O-ring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Reinforcement core facilitates O-ring installation

Reinforcement core holds O-ring in place within a structure while adjacent parts are being assembled. The core in the O-ring adds circumferential rigidity to the O-ring material. This inner core does not appreciably affect the sectional elasticity or gland-sealing characteristics of the O-ring.

Source record↗

SAVY O-ring characterization for lifetime extension

Los Alamos National Laboratory and Nuclear Filter Technology, Inc. developed the SAVY-4000 nuclear material storage container, named after the designers Stone, Anderson, Viers, and Yarbro. The SAVY 4000 meets the requirements of Department of Energy (DOE) M 441.1-1,2 Nuclear Material Packaging Manual, to protect workers who handle nuclear materials against radiation exposures resulting from the leakage of stored materials. The SAVY-4000 is an innovative and creative design: it can be opened and closed in a few seconds without using torque wrenches and instead only a tire iron or equivalent prying tool; has a built-in, fire-rated filter that prevents the build-up of hydrogen gas yet retains 99.97% of plutonium particulates at 200 ACCM rated flow; and prevents the release of stored materials upon a 12- foot drop.

42 ENGINEERING↗

FY2025 Status Report: Model 9975 O Ring Fixture Long-Term Leak Performance

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package have been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The mock-up PCV fixtures are leak tested periodically, and all GLT O-ring fixtures aged at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aged at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years of aging without failure. Two of these retired fixtures were returned to testing and heated to 350 °F to evaluate the impact of additional heating at higher temperature for aged O-rings. Fixture #20 failed after 3 months while fixture #18 failed after 9 months at 350 °F. These O-rings demonstrated that aged and in-service O-rings can continue to be used, even at higher temperatures, after being in storage, and their leak performance are consistent with other samples at 350 °F. There has been one GLT O-ring fixture which failed after 13.4 years of aging at 200 °F. However, 20 other GLT O-rings aging at 200 °F have remained leak-tight for over 16.9 years and remain in test. There are two GLT O-ring fixtures at 270 °F; one fixture has failed after 12.9 years while the other fixture remains in test after 12.5 years. All GLT-S O-ring fixtures aged at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 250 °F for 14.9 years, while one GLT-S O-ring fixture failed after 12.4 years at 200 °F. The leak testing data to date suggest the GLT and GLT-S O-rings aging in the K-Area Complex (KAC) storage at temperatures of 158 °F might maintain a leak-tight seal for up to 59 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in KAC. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 24 mock-up PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SAVY-4000 Finite-Element Drop Test Analysis

PFE Auxiliary Systems conducted drop testing on SAVY-4000 containers to evaluate structural response under 12-foot drop conditions. In support of that effort, a finite-element modeling capability was developed to simulate drop response across multiple container sizes and impact orientations. The purpose of this work was to provide a consistent analysis framework that could support interpretation of testing, compare response trends across multiple configurations, and generate quantities of interest for later comparison with experimental data. More broadly, the analysis and testing were intended to assess whether the containers continued to perform their primary function after a 12-foot drop, namely maintaining structural integrity and containment of the contents. The modeling approach combined an implicit preload analysis with an explicit drop simulation so that each drop event began from a mechanically realistic assembled condition, including compression of the silicone O-ring. Separate models were developed for 2-quart, 5-quart, 12-quart, and 10-gallon containers. The results were evaluated in terms of strain-gauge response, collar-lid gap behavior, and accumulated plastic strain. In addition, parametric studies were performed on the 2-quart container to assess sensitivity to O-ring stiffness, friction, canister thickness, geometry tolerance, and mesh density. The simulations showed that predicted drop responses depended strongly on both container size and drop orientation. Gap metrics identified cases in which the predicted collar-lid opening exceeded the nominal O-ring cross-section threshold, while plastic strain metrics identified localized regions of elevated permanent deformation. Parametric studies showed that the predicted response was especially sensitive to the assumed O-ring stiffness and contact friction, while the geometry tolerance study produced smaller changes in the cases examined. The main value of this work was that it established a repeatable modeling and simulation workflow to support drop-test implementation, evaluate effects of future configuration changes, and understand modeling assumptions that most influenced predicted response. At the current stage, the results were viewed as preliminary model predictions rather than validated predictions. The next step would be to compare drop-test data to the model so that predictive values of the workflow could be refined and used with greater confidence to assess whether the containers maintained structural integrity and containment of the contents after a 12-foot drop.

42 ENGINEERING↗

Effects of high-pressure hydrogen exposure on filler-elastomer adhesion

Elastomers are known to gain enhanced mechanical properties through compounding with nanosized filler particles such as silica or carbon black. Filler dispersion and filler-polymer interfacial strength are key contributing factors to this improvement. The interfacial strength is critical to part lifetime in pressurized gas sealing applications such as O-rings, where weak binding between the filler particle and polymer matrix can lead to internal void structures. With the aim to build a fundamental understanding of precursors to pressurized hydrogen-induced failure in elastomers, we use all-atom molecular dynamics simulations to study the impact of hydrogen oversaturation on filler-polymer interaction strength. We systematically study the interface between a commonly used elastomer, ethylene-propylene-diene monomer (EPDM) and silica by varying gas concentration, crosslink density, and surface chemistry. Our simulations predict that decompression leads to a localization of excess gas near the interface. In conclusion, we demonstrate that this localized gas can weaken interfacial adhesion and quantify the interaction using thermodynamic approaches.

EPDM↗

Production of a Sustainable Aviation Fuel Additive from Waste Polystyrene

Sustainable aviation fuels (SAFs) are an important lever to achieving net zero CO 2 emissions in aviation. Fuel quality standards limit the blend volume of nonpetroleum-based jet fuel such as synthetic paraffinic kerosene (SPK) in Jet A to 50 vol %. One reason for this limit is the limited seal-swelling ability of SPK. Ethylbenzene (EB) as an additive can improve the swelling propensity of SPK. In this study, EB was produced through polystyrene pyrolysis, hydrogenation, and separation. The thermal pyrolysis of polystyrene produced a styrene-rich pyrolyzate. The pyrolyzate was hydrogenated by using Pd/C to produce an EB-rich mixture that yielded a crude EB of ∼90% purity on distillation. The O-ring swelling ability of crude EB of ∼90% purity was tested as a 12 and 16 vol % blend with SPK. Results reveal that EB addition enhanced seal swelling, but a more refined EB grade would be preferable. The results provide a pathway to address the twin issues of plastic pollution and SPK property improvement.

99 GENERAL AND MISCELLANEOUS↗

Measuring 3D Profilometry of SAVY-4000 Nuclear Material Storage Containers: Novacam TubeInspect Capabilities Report

The SAVY-4000 container series is a general-purpose interim storage container for nuclear materials, developed and maintained by Los Alamos National Laboratory (LANL). It is the first vented, general-use nuclear material container to be demonstrated as meeting the requirements outlined in DOE M 441.1-1, the Nuclear Material Packaging Manual. Due to the challenging radiation, thermal, and corrosive storage conditions that the SAVY containers must endure, continuous surveillance techniques are employed to ensure the containers meet all safety standards and specifications. These inspections are typically performed by human operators, who check for issues such as corrosion, O-ring deterioration, corrosion, filter integrity, and potential manufacturing defects. However, human inspections alone are not sufficient, and automated inspection technologies, such as the ATIS system, as well as other automated systems are also utilized. The MicroCam TubeInspect, developed by Novacam Technologies Inc., is designed to address the challenges of understanding how manufacturing variations in the SAVY-4000 container series may affect performance. It is a 3D profilometry measurement system that enables detailed analysis of surface features, including defects, surface roughness, and manufacturing variations. This advanced tool significantly enhances rapid surveillance techniques for both pristine and used containers. In this study, container properties such as surface roughness, thickness, and geometric attributes like circularity are measured for SAVY-4000 containers. Artificially corroded or dented containers are examined to demonstrate the MicroCam's ability to quantify defects. A sensitivity analysis is also conducted, comparing the MicroCam results to those obtained using more precise instruments such as confocal microscopy. This comparison aims to provide valuable insights into container quality, durability, and potential improvements in manufacturing processes.

42 ENGINEERING↗

Polymers used in 4 mm PV Connectors [Slides]

Polymer cracks are not a new problem in the PV industry. However, the suddenness and severity of the cracking connector model is new and concerning. Some sites are experiencing wide-spread cracking of a specific connector model. The preliminary investigation results are (1) there are potential clearance issues with the O-ring, leading to high mechanical stress; (2) potential use of lubrication yields polymer embrittlement; and (3) clear mechanical or chemical differences between the affected model and other PPE-based models using FTIR and tensile testing could not be demonstrated.

36 MATERIALS SCIENCE↗

Vented piston seal prevents fluid leakage between two chambers

To prevent fluid leakage around piston seals separating two fluids under differential pressure, a venting system has been devised. Two methods may be used for venting seals through internal passages to an external low-pressure area, O-ring or split-ring seals.

Mac Glashan, W. F.↗

Self sealing disconnect for tubing forms metal seal after breakaway

Disconnect fittings form a positive metal seal when the fill tube pulls against a metal sleeve when disconnected by force. A specially designed sleeve surrounds the fill tube. O-rings in the shoulder of the sleeve and near the outer end of the fill tube seal against leakage.

Gernandt, H. H.↗

Feasibility of liquid-metal vacuum seals

A basic component of any ultrahigh-vacuum system is a seal capable of isolating a test chamber from its higher pressure surroundings. Two of the most common vacuum seals now in use are the elastomer O-ring seal and the metallic shear seal. The former has the problem of outgassing and gas permeation; the latter requires a large force per unit seal-length to maintain the sealing action. The search for a seal which would provide minimal virtual and real leak rates in a chamber, without requiring a large force to consummate the seal, led to investigation of a liquid-metal seal.

SEALANT↗