Search NASA⌕ Search

SEARCH · Search NASA

Results for “OCCS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

SAFE-OCC: A novelty detection framework for Convolutional Neural Network sensors and its application in process control

Herein we present a novelty detection framework for Convolutional Neural Network (CNN) sensors that we call Sensor-Activated Feature Extraction One-Class Classification (SAFE-OCC). We show that this framework enables the safe use of computer vision sensors in process control architectures. Emergent control applications use CNN models to map visual data to a state signal that can be interpreted by the controller. Incorporating such sensors introduces a significant system operation vulnerability because CNN sensors can exhibit high prediction errors when exposed to novel (abnormal) visual data. Unfortunately, identifying such novelties in real-time is nontrivial. To address this issue, the SAFE-OCC framework leverages the convolutional blocks of the CNN to create an effective feature space to conduct novelty detection using a desired one-class classification technique. This approach engenders a feature space that directly corresponds to that used by the CNN sensor and avoids the need to derive an independent latent space. We demonstrate the effectiveness of SAFE-OCC via simulated control environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding the Impact of User Frustration Intensities on Task Performance Using the OCC Theory of Emotions

Have you heard the saying "frustration is written all over your falce"? Well this saying is true, but that is not the only place. Frustration is written all over your face and your body. The human body has various means to communicate an emotion without the utterance of a single word. The Media Equation says that people interact with computers as if they are human: this includes experiencing frustration. This research measures frustration by monitoring human body-based measures such as heart rate, posture, skin temperature. and respiration. The OCC Theory of Emotions is used to separate frustration into different levels or intensities. The results of this study showed that individual intensities of frustration exist, so that task performance is not degraded. Results from this study can be used by usability testers to model how much frustration is needed before task performance measures start to decrease.

Washington, Gloria↗

Earth Resources Technology Satellite Operations Control Center (OCC). ERTS-B flight activation plan

Included in this plan are general objectives through Day 7, operational guidelines and restraints. Following the activation of all subsystems (through Day 3), special series of payload operations were performed to obtain data samples for the different combinations of exposure/gain settings. This took place from Day 4 through Day 7. The Orbit Adjust was employed to perform vernier corrections after the orbit had been defined. The orbit data was collected through Day 3, with the corrections being made from Day 4 through Day 7. ERTS command auxiliary memory (ECAM) was turned on in Day 3 and the memory dumped to a narrow band tape recorder. A verification of memory was done in the off line mode. ECAM was not used in a payload support mode until Day 7.

Source record↗

Energy-saving potential evaluation for primary schools with occupant-centric controls

Recent studies demonstrated that there is significant energy-saving potential for primary schools, which heating, ventilation, and air-conditioning (HVAC) systems with occupant-centric control (OCC) is an excellent candidate to save energy. However, such an energy impact has yet to be evaluated for different climate zones as well as different energy code versions, but is critical for technology transfer and deployment. Therefore, this paper conducts comprehensive evaluation on the energy-saving potentials for the primary schools with two advanced OCC strategies: presence-based and counting-based. In this work, ninety-six building energy models with stochastic behavior of occupants are developed and simulated, which consist of two building energy code versions, 16 climate zones, and baseline case (without OCC) and two advanced cases (with OCC). To evaluate the energy saving potentials for OCC, primary schools in the U.S. are used as an example. The results show that there is significant energy-saving potential for primary schools by considering OCC strategies, especially the counting-based case. The energy-saving potential is up to 10.2% for presence-based OCC and 12.41% for counting-based OCC. Furthermore, both climate and code version have a significant impact on energy savings from OCC strategies. The energy-saving potentials vary from 1.79% to 12.41% for different climates and code versions. This evaluation can also contribute to quantify the nationwide energy saving potential for other countries.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

[2 + 2] Cycloaddition Produces Divalent Organic Color-Centers with Reduced Heterogeneity in Single-Walled Carbon Nanotubes

Organic color centers (OCCs), generated by the covalent functionalization of single-walled carbon nanotubes, have been exploited for chemical sensing, bioimaging, and quantum technologies. However, monovalent OCCs can assume at least 6 different bonding configurations on the sp 2 carbon lattice of a chiral nanotube, resulting in heterogeneous OCC photoluminescence emissions. Herein, we show that a heat-activated [2 + 2] cycloaddition reaction enables the synthesis of divalent OCCs with a reduced number of atomic bonding configurations. The chemistry occurs by simply mixing enophile molecules (e.g., methylmaleimide, maleic anhydride, and 4-cyclopentene-1,3-dione) with an ethylene glycol suspension of SWCNTs at elevated temperature (70–140 °C). Unlike monovalent OCC chemistries, we observe just three OCC emission peaks that can be assigned to the three possible bonding configurations of the divalent OCCs based on density functional theory calculations. Notably, these OCC photoluminescence peaks can be controlled by temperature to decrease the emission heterogeneity even further. Furthermore, this divalent chemistry provides a scalable way to synthesize OCCs with tightly controlled emissions for emerging applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Human Supervision of Autonomous Vehicle Fleet Operations and Associated Passenger Communications: Preprint

Advances in automated vehicle (AV) technology and expanded operations are rapidly emerging with Automated Mobility District (AMD) deployments in global cities. NLR's AMD research addresses critical elements of human supervision of AV fleet operations and associated passenger communications for vehicles in which no driver or safety attendant is present. Although sufficiently advanced AVs no longer have direct oversight by a driver, fleet management remains staffed with operations personnel at the operations command and control (OCC) facility. This paper examines the functionality of the OCC, drawing comparisons of how automated train control and automated people mover OCCs operate. Within an AMD, the OCC manages various vehicle types, sizes, and operational modes, including on-demand and fixed route service, to facilitate a 'network of networks' for transport within a metropolitan area. The OCC serves as oversight for multiple AV fleets assisting AVs via remote operation of vehicles, communication, and dispatching personnel to resolve problems. The OCC also coordinates system operation, geographically staging vehicles, and managing weather, police, and emergency events. Informed by traffic management center (TMC) strategies using highly integrated software and communications, OCCs facilitate seamless information flows. OCC personnel remotely assist passengers and oversee multi-party operation to ensure safety and security. Although social norms mitigate large-capacity unattended vehicle operations, social interaction in multi-party automated small vehicles has little precedent. This poses a new frontier for society and requires research to effectively understand and manage. Future research will monitor OCC implementations, passenger interfaces, and deployment scaling of initial AMD systems.

33 ADVANCED PROPULSION SYSTEMS↗

Ten questions concerning occupant-centric control and operations

Occupant-Centric Control and Operation (OCC) represents a transformative approach to building management, integrating sensing of indoor environmental quality, occupant presence, and occupant-building interactions. These data are then utilized to optimize both operational efficiency and occupant comfort. This paper summarizes the findings from the IEA-EBC Annex 79 research program's subtask on real world implementations of OCC during the past 5 years. First, in Q1 and Q2, we provide a definition and categorization of OCC. Q3 addresses the role of building operators for OCC, while Q4 describes the implications for designers. Then, Q5 and Q6 discuss the role and possibilities of OCC for load flexibility, and for pandemic induced paradigm shifts in the built environment, respectively. In Q7, we provide a taxonomy and selection process of OCC, while Q8 details real world implementation case studies. Finally, Q9 explains the limits of OCC, and Q10 provides a vision for future research opportunities. Furthermore, our findings offer valuable insights for researchers, practitioners, and policy makers, contributing to the ongoing discourse on the future of building operations management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long-Term field testing of the accuracy and HVAC energy savings potential of occupancy presence sensors in A Single-Family home

The energy-saving potential of occupancy-centric smart thermostats has been extensively explored in simulations but lacked field testing for energy savings quantification and sensor performance assessment in real buildings. This paper presents a long-term field study conducted in a single-family home in Texas, U.S. to evaluate the performance of occupancy-centric controls (OCC) of HVAC (heating, ventilation, and air-conditioning) system in terms of energy savings, sensor accuracy, and impact on electric peak demand. The test site was equipped with a commercial off-the-shelf (COTS) smart thermostat and multiple occupancy presence sensors for OCC implementation. Additionally, a sub-metering system was installed to monitor electricity consumption of various end-use equipment, including the HVAC system. A supplementary device was installed to track the ground-truth occupancy for the accuracy evaluation of the occupancy presence sensor. Scenarios of baseline and OCC controls were alternated weekly over the 20-month testing period. The results indicated an effective OCC execution, as evidenced by indoor temperature profiles. During the 2023 cooling season, OCC achieved total energy savings of 1,958 kWh, corresponding to a 17.6% energy savings ratio. Under certain conditions, daily HVAC energy savings reached as high as 17 kWh, with a savings ratio of 35%. Sensor performance showed an overall accuracy of 83.8%, a False Positive Rate (FPR) of 12.8%, and a False Negative Rate (FNR) of 47.4%. A key limitation was the sensor’s inability to detect stationary occupants during sleep, leading to a midnight FNR of nearly 100% and significantly compromising thermal comfort. Additionally, the implementation of OCC resulted in extended periods of high electricity demand on summer afternoons, affecting occupant’s thermal comfort and posing potential challenges to community-level grid operations if OCC were widely adopted. Furthermore, this study addresses a critical research gap by empirically investigating energy-saving potential and occupancy sensor performance in residential buildings. Through a comprehensive field-testing study, the research examines the interrelationship between sensor accuracy, energy savings, and thermal comfort, an area that has received limited attention in the current literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

From occupants to occupants: A review of the occupant information understanding for building HVAC occupant-centric control

Occupants are the core of the built environment. Traditional Heating, Ventilation, and Air-Conditioning (HVAC) systems operate with predefined schedules and maximum occupancy assumptions with no consideration of specific occupant information. These generalized assumptions usually do not align with the actual demand and result in over-conditioning and occupant discomfort. In recent years, with the aid of Information & Communication Technology (ICT) and Computer Science (CS), it is possible to acquire real-time and accurate occupant information to satisfy the exact thermal requirement through specific HVAC control in one particular built environment. This mechanism is called HVAC “Occupant-centric Control (OCC).” HVAC OCC strategy starts with collecting the occupant’s information (e.g., presence/absence) and then applies it to meet the occupant’s requirement (e.g., thermal comfort). However, even though some research studies and field pilot demonstrations have been devoted to the field of OCC, there is a lack of systematic knowledge about occupant data, which is the principal component of OCC for HVAC researchers and practitioners. To fill this gap, this review paper discusses OCC with a particular emphasis on occupant information and investigates how this information can assist HVAC operation in providing an acceptable built environment in required spaces during the required time. Finally, we provide a fine-grained, comprehensive picture of occupant information, discuss its features, the modalities of information feed-in into the HVAC control, and the application of commonly utilized occupant information for OCC.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Earth Observatory Satellite system definition study. Report 5: System design and specifications. Volume 5: Specification for EROS operations control center

The functional, performance, and design requirements for the Operations Control Center (OCC) of the Earth Observatory Satellite (EOS) system are presented. The OCC controls the operations of the EOS satellite to acquire mission data consisting of: (1) thematic mapper data, (2) multispectral scanner data on EOS-A, or High Resolution Pointable Imager data on EOS-B, and (3) data collection system (DCS) data. The various inputs to the OCC are identified. The functional requirements of the OCC are defined. The specific systems and subsystems of the OCC are described and block diagrams are provided.

Source record↗

Dynamics of Dust Particles Released from Oort Cloud Comets and Their Contribution to Radar Meteors

The Oort Cloud Comets (OCCs), exemplified by the Great Comet of 1997 (Hale-Bopp), are occasional visitors from the heatless periphery of the solar system. Previous works hypothesized that a great majority of OCCs must physically disrupt after one or two passages through the inner solar system, where strong thermal gradients can cause phase transitions or volatile pressure buildup. Here we study the fate of small debris particles produced by OCC disruptions to determine whether the imprints of a hypothetical population of OCC meteoroids can be found in the existing meteor radar data. We find that OCC particles with diameters D < or approx. 10 microns are blown out from the solar system by radiation pressure, while those with D > or approx. 1 mm have a very low Earth-impact probability. The intermediate particle sizes, D approx. 100 microns represent a sweet spot. About 1% of these particles orbitally evolve by Poynting-Robertson drag to reach orbits with semimajor axis a approx. 1 AU. They are expected to produce meteors with radiants near the apex of the Earth s orbital motion. We find that the model distributions of their impact speeds and orbits provide a good match to radar observations of apex meteors, except for the eccentricity distribution, which is more skewed toward e approx. 1 in our model. Finally, we propose an explanation for the long-standing problem in meteor science related to the relative strength of apex and helion/antihelion sources. As we show in detail, the observed trend, with the apex meteors being more prominent in observations of highly sensitive radars, can be related to orbital dynamics of particles released on the long-period orbits.

Nesvorny, David↗

Recycled Cardboard Containers as a Low Energy Source for Cellulose Nanofibrils and Their Use in Poly(l-lactide) Nanocomposites

Cellulose nanomaterials have attracted a great deal of interest as sustainable alternatives to nonrenewable or fossil fuel-derived materials, particularly in composite applications. Cellulose nanofibrils (CNF) are most often derived from wood sources through energy-intensive and costly mechanical fibrillation processes. Here, recycled cardboard, referred to as old corrugated cardboard (OCC), was investigated as an alternate CNF source. OCC is a recycled material that can be obtained at one-tenth the cost of the commonly used bleached softwood Kraft pulp and can be refined to similar levels with nearly one-half of the energy consumption. Additionally, the distinct composition and morphology of OCC-derived CNF provides a more favorable fiber–matrix interface and better reinforcement capabilities of the cellulose nanofibrils in polymer matrices, displaying an over 70% increase in tensile modulus at a loading of 40 wt % with no decrease in tensile strength. When paired with biobased poly(l-lactide) (PLLA), OCC-derived CNF is proven to be an attractive low-cost and low-energy reinforcing agent for sustainable, high performance nanocomposites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Techno-economic analysis of advanced small modular nuclear reactors

Here, small modular nuclear reactors (SMRs) represent a robust opportunity to develop low-carbon and reliable power with the potential to meet cost parity with conventional power systems. This study presents a detailed, bottom-up economic evaluation of a 12 × 77 MW e (924 MW e total) light-water SMR (LW-SMR) plant, a 4 × 262 MW e (1,048 MW e ) gas-cooled SMR (GC-SMR) plant, and a 5 × 200 MW e (1,000 MW e total) molten salt SMR (MS-SMR) plant. Cost estimates are derived from equipment costs, labor hours, material inputs, and process-engineering models. The advanced SMRs are compared to natural gas combined cycle plants with and without post-combustion carbon capture and a conventional large nuclear reactor. Overnight capital cost (OCC) and levelized cost of energy (LCOE) estimates are developed. The OCC of the LW-SMR, GC-SMR, and MS-SMR are found to be $\$4,844$/kW, $\$4,355$/kW, and $\$3,985$/kW respectively. The LCOE of the LW-SMR, GC-SMR, and MS-SMR are found to be $\$89.6$/MWh, $\$81.5$/MWh, and $\$80.6$/MWh respectively. A Monte Carlo analysis is performed, for which the OCC and construction time of the LW-SMR is found to have a lower mean and standard deviation than a conventional large reactor. The LW-SMR OCC is found to have a mean of $\$5,233$/kW with a standard deviation of $\$658$/kW and a 90 % probability of remaining between $\$4,254$/kW and $\$6,399$/kW, while the construction duration is found to have a mean of 4.5 years with a standard deviation of 0.8 years and a 90 % probability of remaining between 3.4 and 6.0 years. The economic impact of economies of scale, simplification, modularization, and construction time for SMRs are discussed. Additionally, policy implications for direct SMR capital subsidies and the impact of a carbon tax on natural gas emissions are explored.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Communication breakdown: Energy efficiency recommendations to address the disconnect between building operators and occupants

As technology advances, progressive building performance goals are met with ease and occupant behavior plays an increasingly significant role in preventing building operators from achieving those goals. However, removing occupants from participating in building control and operation is counterintuitive to the purpose of building operation. Occupant-centric control (OCC) has been suggested as a means of incorporating the occupant while simultaneously reducing the negative impact their behavior can have on building performance. As a result, operators are now tasked with incorporating OCC into their daily operation. The relationship between building occupants and operators is a critical component to OCC, and balancing occupant comfort and building performance. In this paper, we present findings from an international qualitative study of building operators with a focus on the operator and occupant relationship. This paper identifies the role operators play in OCC, how these relationships develop, and how these relationships impact building operation through two key research questions: What factors influence the quality of relationships between occupants and operators? How can the relationships between operators and occupants be improved? Subsequently, these questions revealed this relationship becomes strained when building performance is prioritized over comfort, occupants are ignored or uneducated, and feedback is negative or sparse. In short: there is a disconnection between operators and occupants. Here we propose several solutions including modifying job requirements to prioritize occupant comfort, educating occupants to make autonomous decisions that are not detrimental to operation, and creating effective communication channels for instances where operator intervention is required.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spatially Adaptive Tunable Lighting Control System with Expanded Wellness and Energy Saving Benefits

Lighting design is becoming increasingly complex, including active dimming for energy savings and spectral tuning for human wellbeing. Modern commercial lighting control systems are already difficult to use, and maintain, and even with so-called Smart Lighting, optimizing light settings is rapidly exceeding the capabilities of direct human control, limiting the adoption of lighting control systems. The growing importance of Occupancy Centric Controls (OCC) for advanced building management systems can be applied to the development of autonomous lighting system controls needed to drive the adoption of advanced lighting controls for improved adaptive “sculpted illumination” for both greater energy savings and broader human wellbeing perspectives. This project, led by Rensselaer Polytechnic Institute, entitled “Spatially adaptive tunable lighting control system with expanded wellness and energy saving benefits” will develop and test an entirely new platform for automated optimized lighting design and control that requires little or no human engagement, yet contours lighting profiles automatically to minimize lighting energy use. We call this approach to lighting control “dynamic light sculpting” since the right amount of illumination is automatically delivered to occupants in real time. Since the system uses new, privacy-preserving occupant position and pose detection technologies developed by Rensselaer for broad OCC building applications, the control system will analyze how to deliver the right amount of the right type of illumination only where and when it is needed based these OCC platforms. To create these powerful autonomous lighting control platforms, the project will integrate evolving augmented reality (AR) and virtual reality (VR) tools with sophisticated lighting and interior design toolkits to create interactive lighting design and control simulators. Using the quickly growing paradigm of digital twins, these tools will integrate light fixture properties, occupancy sensor data, interior design data, and lighting specifications to accurately visualize how various design concepts interact with simulated yet realistic human activities that occur in commercial office buildings of various types. These advanced digital twin design and simulation tools will be combined with a new class of digitally-programmable LED lighting fixtures that can dynamically change the spectral content and direction of light emission. When fully integrated, the new autonomous lighting control system will take all of the guesswork out of optimizing light quality while minimizing energy consumption. Digital twin tools will simplify the design, installation, commissioning, operation, and maintenance of future energy-efficient lighting systems. It should be possible to reduce lighting energy costs from 40% to 70% with OCC based dynamic light sculpting systems. The work will be led by the Center for Lighting Enabled Systems and Applications (LESA) and the Center for Architectural Science and Ecology (CASE), both at Renssealer Polytechnic Institute; Lumileds, a global leader in the development of advanced LED systems; and HKS, a leading global architecture design firm. This interdisciplinary project team’s experience includes all of the design simulation tools, VR/AR digital twin visualization technology, advanced occupancy sensing technology, and complex control system design capabilities that will revolutionize lighting design and control technology to autonomously deliver high-quality lighting that improves human health and wellbeing while simultaneously maximizing lighting energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and Validation of a Non-Invasive, Chairside Oral Cavity Cancer Risk Assessment Prototype Using Machine Learning Approach

Oral cavity cancer (OCC) is associated with high morbidity and mortality rates when diagnosed at late stages. Early detection of increased risk provides an opportunity for implementing prevention strategies surrounding modifiable risk factors and screening to promote early detection and intervention. Historical evidence identified a gap in the training of primary care providers (PCPs) surrounding the examination of the oral cavity. The absence of clinically applicable analytical tools to identify patients with high-risk OCC phenotypes at point-of-care (POC) causes missed opportunities for implementing patient-specific interventional strategies. This study developed an OCC risk assessment tool prototype by applying machine learning (ML) approaches to a rich retrospectively collected data set abstracted from a clinical enterprise data warehouse. We compared the performance of six ML classifiers by applying the 10-fold cross-validation approach. Accuracy, recall, precision, specificity, area under the receiver operating characteristic curve, and recall–precision curves for the derived voting algorithm were: 78%, 64%, 88%, 92%, 0.83, and 0.81, respectively. The performance of two classifiers, multilayer perceptron and AdaBoost, closely mirrored the voting algorithm. Integration of the OCC risk assessment tool developed by clinical informatics application into an electronic health record as a clinical decision support tool can assist PCPs in targeting at-risk patients for personalized interventional care.

60 APPLIED LIFE SCIENCES↗

Body Weight Gain during Altered Gravity: Spaceflight, Centrifugation and Transitions

Gravity is a force that influences all living systems, and is often disregarded in the study of environment on growth and development. To assess the effect of gravity exposure on growth, immature rats (130-200 g) were evaluated during chronic altered gravity exposure and during transition between gravity fields. The effects of 14 days of spaceflight on body weight gain were evaluated (n=12) and compared to controls. Spaceflight did not affect weight gain. In 6 rats, the transition from spaceflight to 1 G showed a significant (p less than 0.05) post flight weight loss over 48 hr of 13 g compared to controls. Over subsequent days this loss was compensated for with no difference noted after 5 days. Exposure to hypergravity, 2 G for 16 days, was evaluated in groups of n=6 (Control; On Center Control (OCC); Centrifuged). With centrifugation or OCC there was a reduction in body weight within 24 hr. The OCC regained control weights within 13 days. The weight difference, 26 +/- 1 g, persisted with 2 G with no subsequent difference in weight gain over days 3-16 compared to controls; 3.7 +/- 0.1 versus 3.9 +/- 0.1 g/day respectively. Transition from centrifugation to 1 G resulted in a weight increase within 48 hours. Over 16 days the rate of gain was increased 3.1 +/- 0.1 g/day for centrifuge compared to 2.1 +/- 0.1 g/day for controls between Day 3 to 16. However, differences from control were still noted on Day 16. Transition from one gravity field to another causes acute changes in body weight. Transition to microgravity or 1 G, following the acute changes, results in adjustments to attain a normal weight. In hypergravity the acute reduction in body weight persist, but weight gain is normal. Transitioning from hypergravity to 1G results in an increased weight gain to compensate for the persistent reduction during exposure.

Wade, Charles E.↗