Search NASASearch

SEARCH · Search NASA

Results for “OCI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

PACE OCI Lunar Calibration: Initial Results

Launched in February 2024, the Ocean Color Instrument (OCI) onboard NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission has started performing its monthly lunar calibrations at ±7degreeslunar phase angle in March 2024. In this paper, we will describe the OCI lunar calibration methodology and show the results of lunar calibration events during the initial months of PACE/OCI operation. A key difference of OCI lunar calibration from heritage sensors is that the lunar disk integrated irradiance is computed from lunar pixel radiance and sampling distance instead of the instrument’s IFOV. PACE provided a near constant sweep rate during lunar calibration allowing accurate determination of OCI pixel sampling extent. OCI performs lunar calibration in baseline science mode with 282 hyperspectral bands from 315 –895 nm and 7 shortwave infrared bands(940 -2260 nm). For each OCI band, we compute the integrated lunar disk irradiance, and compare the result with a lunar irradiance model (ROLO)prediction. The early results presented here clearly show that OCI’s lunar image acquisition is working as intended and will provide accurate data for OCI’s on-orbit radiometric characterization. The hyperspectral lunar irradiances provided by OCI are expected to become a valuable data set for the evaluation of lunar irradiance models.

calibration

New Global Ocean Color Sensor: OCI on PACE

- OCI will provide TOA radiances at ~1km spatial resolution, from 340nm (315nm?) to 2260nm, hyperspectral from 340nm to 890nm, 2 day global coverage - OCI will continue and enhance NASA’s earth system data records for ocean color (heritage sensors: SeaWiFS, MODIS, VIIRS) - OCI flight unit is close to being ready for testing (planned for March 2022 to September 2022) - OCI ETU (Engineering Test Unit) completed testing summer 2021, results look promising (see next presentation) - On-orbit calibration will combine successful trending approaches from previous sensors (2 solar diffusers, QVD, lunar gain trending, spectral trending) - New calibration approaches for OCI: large QVD, dim diffuser for linearity trending, lunar hysteresis trending - OCI will be characterized prelaunch with an ambitious goal of 0.5% relative uncertainty; absolute uncertainty will be about 2% (before vicarious calibration); expected on-orbit gain trending accuracy is 0.2% or better - More info on PACE and OCI can be found at https://pace.oceansciences.org/

radiometer

Spatial Characterization of PACE OCI ETU Using Time-Delay Mode

The OCI (Ocean Color Instrument) is the main sensor on the upcoming PACE (Plankton Aerosol Cloud ocean Ecosystem) mission. OCI has two hyperspectral CCD sensors covering 340nm to 885nm and 9 SWIR (Short Wave IR) bands from 940nm to 2260nm. SWIR bands have nominal 1km ground pixel size and CCD bands have native 1/8 km ground pixel size in diagnostic mode that will be aggregated into 1km pixels to improve SNR and meet the data rate constraints. OCI has a rotating telescope that is synchronized to the readout of the CCD and SWIR detectors. Full pre-launch system level testing for the OCI ETU (Engineering Test Unit) was completed in June 2021.With time-delayed scan mode, a sub-pixel level time-delay step is applied to the detector readout. This sub-pixel level time-delay step causes a sub-pixel level shift in the start of the data collection. After collecting time-delay step scans with different step sizes, a scan profile with sub-pixel resolution can be constructed. 1/8 and 1/4 of CCD pixel resolutions were achieved using this mode. In this paper, the OCI time-delayed scan mode will be described as well as how it was used to calculate OCI’s high spatial resolution PSF (Point Spread Function), IFOV (instantaneous Field of View), MTF (Modulation Transfer Function), and BBR (Band to Band Registration).

PACE

PACE OCI Pre-launch ETU Spectral Characterization and Performance

The Ocean Color Instrument (OCI) is the primary sensor on the upcoming Plankton, Aerosol, Cloud ocean Ecosystem (PACE) mission. OCI is a new type of sensor compared to NASA’s ocean color heritage sensors VIIRS, MODIS, and SeaWiFs. Unlike its heritage sensors, OCI has two slit grating hyperspectral spectrographs in addition to a fiber-coupled multiband filter spectrograph. The two hyperspectral spectrographs provide continuous coverage from 340nm to 885nm in the UV to NIR range. These spectrographs use programmable CCD detectors that aggregate multiple CCD pixels that can effectively provide various spectral resolutions. The fiber-coupled multiband filter spectrograph provides seven discrete spectral bands from 940nm to 2260nm. OCI completed system level testing of the Engineering Test Unit (ETU) in June 2021 at the Goddard Space Flight Center (GSFC). The ETU contains one of the slit grating spectrographs (600nm to 885nm) and the fiber-coupled spectrograph. The ETU was tested in thermal vacuum (TVAC) in February 2020 and January 2021 to assess characterization and performance compliance to design requirements. This paper presents an overview of the spectral performance of the OCI ETU for relative spectral response (RSR), integrated Out-of-Band response (IOOB), system gain, band centers, and bandwidths.

PACE

PACE OCI Flight Unit Pre-launch Spectral Characterization

The Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission [1] will extend and improve the data record of NASA’s satellite observations of global ocean biology, aerosols, and clouds. The Ocean Color Instrument (OCI) is the primary sensor on-board the PACE platform [2]. The OCI is a scanning radiometer with hyperspectral coverage from the ultraviolet (UV) to the near infrared (NIR) wavelength range and a fiber-coupled multiband filter spectrograph in the short-wave infrared (SWIR) spectral region. The OCI Flight Unit completed system level testing in November 2022 at the Goddard Space Flight Center (GSFC). This paper presents the spectral characterization and performance of the OCI Flight Unit. The OCI Flight spectral performance was determined to be within design specifications and the characterization was measured within specified uncertainties.

PACE

Pace Oci Flight Unit Pre-Launch Spectral Characterization

The Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission [1] will extend and improve the data record of NASA’s satellite observations of global ocean biology, aerosols, and clouds. The Ocean Color Instrument (OCI) is the primary sensor on-board the PACE platform [2]. The OCI is a scanning radiometer with hyperspectral coverage from the ultraviolet (UV) to the near infrared (NIR) wavelength range and a fiber-coupled multiband filter spectrograph in the short-wave infrared (SWIR) spectral region. The OCI Flight Unit completed system level testing in November 2022 at the Goddard Space Flight Center (GSFC). This paper presents the spectral characterization and performance of the OCI Flight Unit. The OCI Flight spectral performance was determined to be within design specifications and the characterization was measured within specified uncertainties.

PACE

Measurement Techniques for the High-Contrast and in-Field Stray-Light Performance of Oci

Scheduled for launch in January 2024, the PACE mission represents NASA’s next investment in ocean biology, clouds, and aerosol data records [1]. A key feature of PACE is the inclusion of an advanced satellite radiometer known as the Ocean Color Instrument (OCI), a global mapping radiometer that combines multispectral and hyperspectral remote sensing. A critical requirement for OCI is the high-contrast or spatial cross-talk specification (also referred to as in-field stray-light response). The requirement states that for global top-of-atmosphere radiances based on measured MODIS radiances, the global average residual contamination shall be less than 0.15% for any multispectral band. Accurate resolution of high contrast in TOA radiance images is important to estimate stray light contamination due to clouds, for studying small scale features like ocean fronts and for working in coastal and estuarine areas where the scales are 1km. This occurs in all wavelengths in the spatial direction. Knowledge of high contrast resolution makes up part of the artifact budget. Accurate measurement of the high-contrast performance of OCI requires laboratory Ground Support Equipment (GSE) that projects a scene of sufficient quality that the unwanted stray light of the GSE itself is not confused with the stray light response of the telescope. This paper concerns the development, analyses and test of the GSE to ensure the quality of the projected image is sufficient to verify the OCI requirements. Optical models were developed for both the instrument as well as the GSE and laboratory environment. Simulation of various non-ideal parameters were critical to accurately predict performance. Measurements using COTS cameras and lenses were also made of the projected GSE image to reasonably verify the optical model predictions. Measured and modelled results from OCI are discussed.

OCI

Measurement Techniques for the High-Contrast and in-Field Stray-Light Performance of OCI

Scheduled for launch in January 2024, the PACE mission represents NASA’s next investment in ocean biology, clouds, and aerosol data records [1]. A key feature of PACE is the inclusion of an advanced satellite radiometer known as the Ocean Color Instrument (OCI), a global mapping radiometer that combines multispectral and hyperspectral remote sensing. A critical requirement for OCI is the high-contrast or spatial cross-talk specification (also referred to as in-field stray-light response). The requirement states that for global top-of-atmosphere radiances based on measured MODIS radiances, the global average residual contamination shall be less than 0.15% for any multispectral band. Accurate resolution of high contrast in TOA radiance images is important to estimate stray light contamination due to clouds, for studying small scale features like ocean fronts and for working in coastal and estuarine areas where the scales are 1km. This occurs in all wavelengths in the spatial direction. Knowledge of high contrast resolution makes up part of the artifact budget. Accurate measurement of the high-contrast performance of OCI requires laboratory Ground Support Equipment (GSE) that projects a scene of sufficient quality that the unwanted stray light of the GSE itself is not confused with the stray light response of the telescope. This paper concerns the development, analyses and test of the GSE to ensure the quality of the projected image is sufficient to verify the OCI requirements. Optical models were developed for both the instrument as well as the GSE and laboratory environment. Simulation of various non-ideal parameters were critical to accurately predict performance. Measurements using COTS cameras and lenses were also made of the projected GSE image to reasonably verify the optical model predictions. Measured and modelled results from OCI are discussed.

OCI, PACE, LSF, PSF, Stray-light, Contrast, Cross-

OCI Geolocation Evaluation and Refinement Using Landsat Control Points

The Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission is NASA’s next investment in ocean biology, clouds, and aerosol data records. A key feature of PACE is the inclusion of an advanced satellite radiometer, Ocean Color Instrument (OCI), a global mapping radiometer that combines multispectral and hyperspectral remote sensing. The geolocation processing is performed for OCI using spacecraft navigation data and an instrument geometry model. To evaluate the geolocation accuracy for OCI and develop refinements to the processing methods, control point matching using Landsat data has been implemented as a step in the operational processing of OCI data at the Science Data Segment. This processing provides between 200 and 300 high-quality matchups per day with good global and geometric distribution, allowing rapid evaluation of the OCI geolocation accuracy. The results provided an early indication of the overall quality of the geolocation processing and of specific aspects needing improvement. A standard set of granules was identified to support rapid implementation and testing of geolocation refinements, and this approach has been highly successful in improving the geolocation processing accuracy to meet the science requirements. The evaluation will continue throughout the mission to ensure the ongoing accuracy of geolocation. This paper describes the control point matching methodology, the approach to development of the geolocation processing refinements, and the recent results.

PACE

OCI Geolocation Evaluation and Refinement Using Landsat Control Points

The Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission is NASA’s next investment in ocean biology, clouds, and aerosol data records. A key feature of PACE is the inclusion of an advanced satellite radiometer, Ocean Color Instrument (OCI), a global mapping radiometer that combines multispectral and hyperspectral remote sensing. The geolocation processing is performed for OCI using spacecraft navigation data and an instrument geometry model. To evaluate the geolocation accuracy for OCI and develop refinements to the processing methods, control point matching using Landsat data has been implemented as a step in the operational processing of OCI data at the Science Data Segment. This processing provides between 200 and 300 high-quality matchups per day with good global and geometric distribution, allowing rapid evaluation of the OCI geolocation accuracy. The results provided an early indication of the overall quality of the geolocation processing and of specific aspects needing improvement. A standard set of granules was identified to support rapid implementation and testing of geolocation refinements, and this approach has been highly successful in improving the geolocation processing accuracy to meet the science requirements. The evaluation will continue throughout the mission to ensure the ongoing accuracy of geolocation. This paper describes the control point matching methodology, the approach to development of the geolocation processing refinements, and the recent results.

PACE

Calibration Plan for the Ocean Color Instrument (OCI) Engineering Test Unit

The Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission will launch no earlier than summer 2022. The primary payload is the Ocean Color Instrument (OCI). OCI is a hyperspectral imaging radiometer that will measure top-of-atmosphere radiances from 340nm to 2260nm at approximately 1km spatial resolution. The spectral resolution will be 5nm from 340nm to 890nm to enable the production of innovative ocean color products on a global scale (OCI will provide global coverage every 2 days). There are 7 different multispectral bands in the shortwave infrared to support atmospheric correction for ocean color and aerosol and cloud studies. Ocean color applications require state of the art radiometric accuracy (approximately 0.5%, excluding the absolute calibration uncertainty). Considerable effort has been invested in the planning of the prelaunch calibration campaign and the on-orbit calibration capabilities. This paper describes the current plans for the prelaunch calibration and characterization campaign of the OCI Engineering Test Unit (ETU), which is scheduled to begin towards the end of 2019, and expected to conclude April 2020. The prelaunch calibration campaign will characterize all sensor characteristics that are expected to influence radiometric sensitivity: absolute calibration (i.e. radiometric gains), signal to noise ratio, nonlinearity, response versus scan angle, dynamic range, straylight, crosstalk, and sensitivities to polarization and temperature. In addition to these characterization tests (which will only be performed once for the ETU), two types of tests have been developed that monitor the evolution of several OCI radiometric characteristics: a Limited Performance Test (LPT, expected duration about 8 hours), and a Comprehensive Performance Test (CPT, expected duration about 2 days).

Meister, Gerhard

Progressive TDI Measurements with the PACE OCI ETU

The Plankton Aerosol Cloud ocean Ecosystem (PACE) Ocean Color Instrument (OCI) has completed the ground test program for its engineering unit (ETU) and testing of the flight unit will begin in the near future. OCIis a grating spectrometer with hyperspectral coverage from about 340 nm to 885 nm with 9 additional filtered channels in the SWIR. Two CCDs are used as detectors for the hyperspectral channels. One important operating mode of the CCDs on OCI is progressive time delay integration (or PTDI). In this mode, the charge in the CCD can be held for multiples of the nominal integration times. A series of these measurements can be made with progressively increasing multiples of the nominal integration time as the instrument scans across a uniform source. Ground testing with this operating mode on OCI ETU has shown promising results. This work will present measurements taken with the PTDI mode and the analysis of OCI ETU linearity and dynamic range

PACE

Initial Look at the Results From the Prelaunch Characterization Campaign of OCI on the Pace Mission

Scheduled for launch in January 2024, the Phytoplankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission represents NASA’s next investment in ocean biology, clouds, and aerosol data records [1]. A key feature of PACE is the inclusion of an advanced satellite radiometer known as the Ocean Color Instrument (OCI), a global mapping radiometer that combines multispectral and hyperspectral remote sensing. This paper describes the results of the prelaunch test campaign of the OCI Flight Unit. The measured OCI flight unit performance exceeded requirement thresholds in all critical areas. Overall, the performance of the OCI is excellent, and will allow the PACE science team to meet its science objectives.

Calibration

Simulating response versus scan angle characterization on OCI for the upcoming PACE mission

The Plankton, Aerosol, Cloud ocean Ecosystem (PACE) mission Ocean Color Instrument (OCI) is the next generation ocean color sensor following on from the SeaWiFS and VIIRS designs, to be launched into low Earth orbit in 2022. Like those heritage sensors, OCI has cross track scanning fore-optics, the reflectivity of which (referred to here as the response versus scan angle or RVS) must be characterized prior to launch. The expected test setup, component reflectivity measurements, instrument model, and heritage sensor testing were used to generate simulated RVS data. This simulated data set was then used to verify the functionality of the analysis software in preparation for the upcoming ground test campaign. The analysis software is designed to characterize the RVS for all OCI bands over the full range of scan angles to be measured on orbit as well as verify compliance with the sensor design requirements in near real-time.

PACE

Aerosol Absorption Retrievals from the PACE Broad Spectrum Ocean Color Instrument (OCI)

The PACE (Pre-­Aerosol, Clouds and ocean Ecosystem) mission, anticipated for launch in the early 2020s, is designed to characterize oceanic and atmospheric properties. The primary instrument on-­‐board will be a moderate resolution (approximately 1 km nadir) radiometer, called the Ocean Color Instrument (OCI). OCI will provide high spectral resolution (5 nm) from the UV to NIR (350 - 800 nm), with additional spectral bands in the NIR and SWIR. The OCI itself is an excellent instrument for atmospheric objectives, providing measurements across a broad spectral range that in essence combines the capabilities of MODIS and OMI, but with the UV channels from OMI to be available at moderate resolution. (Image credit: PACE Science Definition Team Report). Objective: Can we make use of the UV-­SWIR measurements to derive information about aerosol absorption when aerosol loading is high?

aerosols

Instrument Level TVAC Testing of the PACE OCI Loop Heat Pipes

The Thermal Control System (TCS) of the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) Ocean Color Instrument (OCI) incorporates two propylene Loop Heat Pipes (LHP). A Thermal Vacuum (TVAC) test was conducted at NASA Goddard Space Flight Center to characterize the fully integrated OCI in the test-as-you-fly configuration. Within the constraints of movement of the OCI in the TVAC chamber, an elaborate series of trending and calibration tests have been accomplished. This paper presents the measured LHP performance along with lessons learned.

loop heat pipe

PACE OCI Short-Wave Infrared Detection Assembly Optical System Design, Alignment, and Environmental Test

The Ocean Color Instrument (OCI), which will be integrated with the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) satellite, will collect science data that will be used to monitor the health of Earth’s oceans and atmosphere. The Short-Wave Infrared (SWIR) Detection Assembly (SDA), built and characterized by Utah State University Space Dynamics Laboratory (SDL), is a subsystem of OCI consisting of 32 channels covering seven discrete optical bands of interest. A total of 16 SWIR Detection Subassemblies (SDSs) compose the SDA and house the cold optical system. The science data optical input for each SDS is supplied by a 0.22 NA multimode fiber interfacing with a fiber adapter. The diverging light from the fiber is collimated, split by a dichroic beamsplitter to two separate channels, filtered by the science filter, and then reimaged onto the single-element detectors with a final 0.76 NA. Aspheric, diamond-turned powered elements are used throughout the optical design. Fabrication and alignment tolerance analysis/budgets are balanced to ensure the optical system meets throughput requirements. All systems are aligned at ambient temperature using an InSb camera and an in-line illumination microscope system to directly image the active detector area through the science filters. Compensators used during alignment are detector focus and decenter, which are adjusted via photoetched shims in increments of 25 µm. Average focus and centering errors were less than 8 µm among all 32 flight and 10 flight spare detectors. Each SDS spectral response and conversion gain was verified at operational temperature of -65°C in vacuum.

OCI

PACE OCI Short-Wave Infrared Detection Assembly frequency-dependent linearity characterization and uncertainty analysis

The Ocean Color Instrument (OCI), the primary payload of the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE)observatory, will collect data to monitor the health of Earth’s oceans and atmosphere. The Short-Wave Infrared(SWIR) Detection Assembly (SDA) was built and characterized by the Utah State University Space DynamicsLaboratory (SDL) and is a subsystem of OCI. The SDA measures seven bands centered at 940, 1038, 1250, 1378,1615, 2130, and 2260 nm, with standard- and high-gain varieties for the 1250 and 1615 nm bands, resulting in nine total detection configurations in the SWIR. The delivery of high-quality science data is critically dependent upon accurately characterizing the linearity of the SDA. Two metrology techniques were employed to measure the linearity and characterize the frequency-dependent linearity uncertainty of the system. The first technique used superposition linearity measurements to determine the DC linearity, and the second technique involved an oscillating small-signal response at seven frequencies to determine the frequency-dependent linearity. Discrepancies between the DC and frequency-dependent linearities constrain the uncertainty between the two. Examining the difference between these two methods for all SDA channels, we find most channels experience an uncertainty below0.2% with a worst-case measurement uncertainty of 0.31%. Averaging SDA channels with similar detectors, optical filters, and electronics to simulate the flight-like data products yields a worst-case frequency-dependence linearity uncertainty of 0.12%, demonstrating minimal frequency dependence, implying an excellent linearity knowledge.Detailed performance knowledge, including linearity performance, verifies data quality and builds confidence in the success of the PACE mission.

PACE