Search NASA⌕ Search

SEARCH · Search NASA

Results for “OMEGA Mission”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Sandia National Laboratories FY20 Progress Report

The Energetic Neutrons campaign led by Sandia National Laboratories (SNL) had a successful year testing electronic devices and printed circuit boards (PCBs) under 14 MeV neutron irradiation at OMEGA. During FY20 the Energetic Neutrons campaign increased the number and complexity of experiments, continued collaborations with external organizations, and generated knowledge that supports SNL’s National Security mission. In FY20 the Energetic Neutrons campaign was executed by an early career team led by a new PI. The SNL team members were trained to take over new responsibilities during the shot day to increase the number and complexity of experiments in the campaigns. Also, in FY20 for the first time the Energetic Neutrons campaign had a graduate student contributing with pre and post-irradiation characterizations at SNL of the semiconductor devices irradiated at OMEGA. In FY20 SNL collaborated with the Air Force Nuclear Weapons Center (AFNWC) and supported experiments related to radiation effects in semiconductor devices. SNL also gave the opportunity to ride along to Los Alamos National Laboratory and multiple scientists from MIT and LLE. SNL continued using the last two generations of the Neutron Effects Diagnostics (NEDs) to field active and passive experiments but also redesigned the latest generation of the NEDs to accommodate larger components and improve the vacuum sealing as shown in figure 1a. The redesigned NEDs allowed SNL to perform active tests of a high voltage (HV) PCB for the first time at OMEGA; where signals before, during and after the irradiation were recorded. The HV PCB installed in one of the SNL NEDs is shown in figure 1b where a 3D-printed nosecone was used to check for mechanical and electrical interference. Passive irradiations of multiple components were followed up with leakage current, gain measurements and radiation-induced defect characterization.

42 ENGINEERING↗

Happy Fall today, from 1959

Pumpkin spice everything, college football and changing leaves. The signs are everywhere and today (Wednesday, Sept. 22) marks the first official day of fall. This throwback photo of the Omega Bridge is from the fall of 1959. The bridge was completed in 1951, among many other infrastructure projects needed to continue the Lab’s shifting national security mission after the end of World War II.

99 GENERAL AND MISCELLANEOUS↗

BeyondPlanck I. Global Bayesian analysis of the Planck Low Frequency Instrument data

We describe the BeyondPlanck project in terms of motivation, methodology and main products, and provide a guide to a set of companion papers that describe each result in fuller detail. Building directly on experience from ESA's Planck mission, we implement a complete end-to-end Bayesian analysis framework for the Planck Low Frequency Instrument (LFI) observations. The primary product is a joint posterior distribution P(omega|d), where omega represents the set of all free instrumental (gain, correlated noise, bandpass etc.), astrophysical (synchrotron, free-free, thermal dust emission etc.), and cosmological (CMB map, power spectrum etc.) parameters. Some notable advantages of this approach are seamless end-to-end propagation of uncertainties; accurate modeling of both astrophysical and instrumental effects in the most natural basis for each uncertain quantity; optimized computational costs with little or no need for intermediate human interaction between various analysis steps; and a complete overview of the entire analysis process within one single framework. As a practical demonstration of this framework, we focus in particular on low-l CMB polarization reconstruction, paying special attention to the LFI 44 GHz channel. We find evidence of significant residual systematic effects that are still not accounted for in the current processing, but must be addressed in future work. These include a break-down of the 1/f correlated noise model at 30 and 44 GHz, and scan-aligned stripes in the Southern Galactic hemisphere at 44 GHz. On the Northern hemisphere, however, we find that all results are consistent with the LCDM model, and we constrain the reionization optical depth to tau = 0.067 +/- 0.016, with a low-resolution chi-squared probability-to-exceed of 16%. The marginal CMB dipole amplitude is 3359.5 +/- 1.9 uK. (Abridged.)

Andersen, KJ↗

Sandia National Laboratories FY21 Progress Report

The Energetic Neutrons campaign led by Sandia National Laboratories (SNL) had a successful year testing electronic devices and printed circuit boards (PCBs) under 14 MeV neutron irradiation at OMEGA. During FY21 Sandia’s Neutron Effects Diagnostics (NEDs) and data acquisition systems were upgraded to test novel commercial off-the-shelf and Sandia-fabricated electronic components that support SNL’s National Security mission. The upgrades to the Sandia platform consisted of new cable chains, sample mount fixtures and a new fiber optics platform for testing optoelectronic devices.

42 ENGINEERING↗

LaserNetUS Collaboration Network—University of Rochester (Final Report)

LaserNetUS Collaborative Network established in 2018 is a network of high-power laser facilities supported by the Department of Energy (DOE) Office of Fusion Energy Sciences (FES) and operating effectively as a user facility. Its mission is to advance and promote intense laser science and applications by providing scientists and students with broad access to unique facilities and enabling technologies, advancing the frontiers of laser-science research, and fostering collaboration among researchers and networks from around the world. Users who submit proposals through an annual call are selected by an external and independent proposal review panel (PRP) not involving personnel from any of the facilities. Besides the Omega Laser Facility at the University of Rochester’s Laboratory for Laser Energetics (UR/LLE), the network during this project period includes high-intensity laser facilities from six other universities and three national laboratories, namely, the Colorado State University (CSU), the University of Michigan (UM), the University of Nebraska at Lincoln (UNL), The Ohio State University (OSU), Université du Québec, the University of Texas at Austin (UT Austin), Lawrence Berkeley National Laboratory (LBNL), SLAC National Accelerator Laboratory (SLAC) and Lawrence Livermore National Laboratory (LLNL), respectively. The network facilities span a wide range in laser pulse energy, pulse duration, repetition rate, and experimental diagnostic equipment enabling innovative research in a variety of exciting areas. Details of the LaserNetUS facilities, organization and committees, events, and accomplishments can be found at the network website (https://lasernetus.org/). A very important role that the LaserNetUS fulfills is the training of students and young scientists who will be key for the future development of laser-plasma science and high-power laser technology itself. The network provides these students not only with access to the most advanced instrumentation and laser facilities, but also the opportunities to interact and collaborate with students from other institutions and with a large group of experienced scientists. As the largest university-based laser users’ facility in the world, the Omega Laser Facility at the UR/LLE has served the high-energy-density physics (HEDP) and inertial fusion science community for nearly 40 years. The multi-beam multi-kJ OMEGA EP Laser System brings unique capabilities to the LaserNetUS network. The combination of high intensity and high energy in short- and long-pulse operation together with solid or gas-jet targets and externally applied magnetic fields provides users a wide domain of experimental conditions. This award provides a total of eight shot days on OMEGA EP for LaserNetUS users. During the award period of performance (June 2019–November 2021), seven teams have fully utilized the eight shot days for their unique science experiments on OMEGA EP with a total of 83 target shots. These experiments involve 13 graduate students, two undergraduate students and six postdoctoral researchers. Results have been widely disseminated at international conferences including LaserNetUS annual meeting (~20 presentations including three invited), and in peer-reviewed journal publications (three published with several manuscripts in preparation).

36 MATERIALS SCIENCE↗

In-orbit performance of the soft X-ray imaging telescope Xtend aboard XRISM

Here, we present a summary of the in-orbit performance of the soft X-ray imaging telescope Xtend onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), based on in-flight observation data, including first-light celestial objects, calibration sources, and results from the cross-calibration campaign with other currently operating X-ray observatories. XRISM/Xtend has a large field of view of ${38{^{\prime }_{.}}5}$ $\times$ ${38{^{\prime }_{.}}5}$, covering an energy range of 0.4–13 keV, as demonstrated by the first-light observation of the galaxy cluster Abell 2319. It also features an energy resolution of 170–180 eV at 6 keV, which meets the mission requirement and enables us to resolve He-like and H-like Fe K$\alpha$ lines. Throughout the observation during the performance verification phase, we confirm that two issues identified in the Soft X-ray Imager (SXI) onboard the previous Hitomi mission—light leakage and crosstalk events—are addressed and suppressed in the case of Xtend. A joint cross-calibration observation of the bright quasar 3C 273 results in an effective area measured to be $\sim$420 cm$^{2}$ at1.5 keV and $\sim$310 cm$^{2}$ at 6.0 keV, which matches values obtained in ground tests. We also continuously monitor the health of Xtend by analyzing overclocking data, calibration source spectra, and day-Earth observations; the readout noise is stable and low, and contamination is negligible even one year after launch. A low background level compared with other major X-ray instruments onboard satellites, combined with the largest grasp ($\Omega _{\rm eff}\sim 60$ cm$^2$ deg$^2$) of Xtend, will not only support Resolve analysis, but also enable significant scientific results on its own. This includes near-future follow-up observations and transient searches in the context of time-domain and multi-messenger astrophysics.

instrumentation: detectors: Xtend↗