Search NASA⌕ Search

SEARCH · Search NASA

Results for “OMPS nadir ozone mapper”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Trend Quality Ozone from NPP OMPS: The Version 2 Processing

A version 2 processing of data from two ozone monitoring instruments on Suomi NPP, the OMPS nadir ozone mapper and the OMPS nadir ozone profiler, has now been completed. The previously released data were useful for many purposes but were not suitable for use in ozone trend analysis. In this processing, instrument artifacts have been identified and corrected, an improved scattered light correction and wavelength registration have been applied, and soft calibration techniques were implemented to produce a calibration consistent with data from the series of SBUV/2 instruments. The result is a high-quality ozone time series suitable for trend analysis. Total column ozone data from the OMPS nadir mapper now agree with data from the SBUV/2 instrument on NOAA 19 with a zonal average bias of −0.2 % over the 60° S to 60° N latitude zone. Differences are somewhat larger between OMPS nadir profiler and N19 total column ozone, with an average difference of −1.1 % over the 60° S to 60° N latitude zone and a residual seasonal variation of about 2 % at latitudes higher than about 50°. For the profile retrieval, zonal average ozone in the upper stratosphere (between 2.5 and 4 hPa) agrees with that from NOAA 19 within ±3 % and an average bias of −1.1 %. In the lower stratosphere (between 25 and 40 hPa) agreement is within ±3 % with an average bias of +1.1 %. Tropospheric ozone produced by subtracting stratospheric ozone measured by the OMPS limb profiler from total column ozone measured by the nadir mapper is consistent with tropospheric ozone produced by subtracting stratospheric ozone from MLS from total ozone from the OMI instrument on Aura. The agreement of tropospheric ozone is within 10 % in most locations.

OMPS nadir ozone mapper↗

Highlights from the 11-Year Record of Tropospheric Ozone from OMI/MLS and Continuation of that Long Record Using OMPS Measurements

Since October 2004 the Ozone Monitoring Instrument (OMI) and Microwave Limb Sounder (MLS) onboard the Aura satellite have provided over 11 years of continuous tropospheric ozone measurements. These OMI/MLS measurements have been used in many studies to evaluate dynamical and photochemical effects caused by ENSO, the Madden-Julian Oscillation (MJO) and shorter timescales, as well as long-term trends and the effects of deep convection on tropospheric ozone. Given that the OMI and MLS instruments have now extended well beyond their expected lifetimes, our goal is to continue their long record of tropospheric ozone using recent Ozone Mapping Profiler Suite (OMPS) measurements. The OMPS onboard the Suomi National Polar-orbiting Partnership NPP satellite was launched on October 28, 2011 and is comprised of three instruments: the nadir mapper, the nadir profiler, and the limb profiler. Our study combines total column ozone from the OMPS nadir mapper with stratospheric column ozone from the OMPS limb profiler to measure tropospheric ozone residual. The time period for the OMPS measurements is March 2012 present. For the OMPS limb profiler retrievals, the OMPS v2 algorithm from Goddard is tested against the University of Saskatchewan (USask) Algorithm. The retrieved ozone profiles from each of these algorithms are evaluated with ozone profiles from both ozonesondes and the Aura Microwave Limb Sounder (MLS). Effects on derived OMPS tropospheric ozone caused by the 2015-2016 El Nino event are highlighted. This recent El Nino produced anomalies in tropospheric ozone throughout the tropical Pacific involving increases of approximately 10 DU over Indonesia and decreases approximately 5-10 DU in the eastern Pacific. These changes in ozone due to El Nino were predominantly dynamically-induced, caused by the eastward shift in sea-surface temperature and convection from the western to the eastern Pacific.

MJO↗

Assessment of Long-term Trends in the Collection 4 Total Ozone Record from the Ozone Monitoring Instrument

Long-term changes in total ozone affect the amount of harmful UV radiation reaching Earth’s surface and reflect progress made towards recovery of stratospheric ozone. Satellite total ozone data are also used to estimate long-term trends in tropospheric ozone, a reactive and potent greenhouse gas, by subtracting the stratospheric column timeseries from that of total ozone. For these scientific applications, the long-term stability should be better than 1%. Left unchecked, instrument calibration drift can produce a trend of this magnitude or greater. NASA has produced nearly twenty years of total ozone data from the Ozone Monitoring Instrument (OMI) using the Total Ozone Mapping Spectrometer (TOMS) algorithm. The drift in the OMI instrument as monitored by ice radiance calibration has been relatively slow, but it has reached a level of ~3% over the mission lifetime. This drift was corrected in the recently released Collection 4 OMI calibrated radiances, updating the Collection 3 calibration released in 2006. We have reprocessed the OMI total ozone record using the Collection 4 calibration and updates to the TOMS algorithm. We summarize these changes and evaluate their impact by comparing to the previous Collection 3 OMI dataset, the Suomi NPP Ozone Mapping and Profiler Suite Nadir Mapper (OMPS-NM) and Solar Backscatter UV (SBUV) Merged Ozone Dataset (MOD) total ozone records and other independent satellite total ozone datasets. Climatological radiance residuals from OMI and OMPS-NM are calculated and compared to investigate differences in spectral calibration that can cause drifts in long-term total ozone trends. We also analyze the tropospheric ozone record produced using the Collection 4 OMI total ozone and stratospheric column ozone from MLS. Collection 3 OMI data processed with the TOMS algorithm show a positive drift relative to other satellite and ground-based data of 1-2 DU per decade. Initial results show that this drift is reduced in Collection 4 OMI, due to the updated OMI calibration. In this work we will quantify the improvements in Collection 4 OMI relative to independent data sources at both the ozone and radiance level

Collection 4 OMI Total Ozone↗

Monitoring Volcanic Eruptions by OMI/OMPS, ASTER, and MERRA-2

Volcanic lava flows and/or the gas eruptions are the most common characteristics that can be remotely monitored with satellite technology in the global perspective and on different timescales. Atmospheric Sulfur Dioxide (SO2), one of the most abundant gases from volcanic eruptions apart from atmospheric common gases Carbon Dioxide and water vapor, can be directly detected by space-based sensors on satellites. The NASA Goddard Earth Sciences Data and Information Services Center (GES DISC) is one of the 12 Distributed Active Archive Centers (DAACs) within NASA's Earth Observing System Data and Information System (EOSDIS), which archives SO2 data sets from the Nimbus-7 Total Ozone Mapping Spectrometer (TOMS) in 1978, till the ongoing Ozone Monitoring Instrument (OMI) on NASA's EOS-Aura satellite, the Ozone Mapping Profiler Suite (OMPS) Nadir Mapper (NM) on both the Suomi National Polar-Orbiting Partnership (Suomi-NPP or SNPP) and the Joint Polar-orbiting Satellite System-1 (JPSS-1) satellites, into the future JPSS missions. In addition to the standard OMI/Aura and OMPS/S-NPP SO2 products, SO2 products created under the charter of the Making Earth System Data Records for Use in Research Environments (MEaSUREs) project, are also archived at GES DISC, through which NASA enacts to expand understanding the Earth system using consistent data records. The Land Processes Distributed Active Archive Center (LP DAAC) is another EOSDIS's DAAC that provides land data products and operates as a partnership with the U.S. Geological Survey (USGS). The LP DAAC has been archiving the satellite imagery from the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) aboard NASA's EOS-Terra satellite, a high spatial resolution (15 meters) and 14 band multispectral instrument. The ASTER imagery is one of the land products contributing to the application for monitoring hot spots and land terrain changes caused by volcanic eruption events. The data potential in GES DISC and LP DAAC to monitor volcanic sources of SO2 and the influence of wind fields on the gas plume spread will be demonstrated with the most recent 2018 May-July Kilauea Volcano eruption.

Zeng, Jian↗

First Observations of SO2 from the Satellite Suomi NPP OMPS: Widespread Air Pollution Events Over China

Severe smog episodes over China in January 2013 received worldwide attention. This air pollution was distinguished by heavy loadings of fine particulate matter and SO2. To characterize these episodes, we employed the Ozone Mapping and Profiler Suite, Nadir Mapper (OMPS NM), an ultraviolet (UV) spectrometer flying on the Suomi National Polar-orbiting Partnership (SNPP) spacecraft since October 2011. We developed an advanced algorithm to quantify SO2 in the lower troposphere and achieved high-quality retrievals from OMPS NM, which are characterized by high precision, approx. 0.2 Dobson Units (DU; 1 DU = 2.69 x 10(exp 16) molecules/sq cm) for instantaneous field of view SO2 data and low biases (within +/-0.2 DU). Here we report SO2 retrievals and UV aerosol index data for these pollution events. The SO2 columns and the areas covered by high pollutant concentrations are quantified; the results reveal for the first time the full extent (an area of approx. 10(exp 6) sq km containing up to 60 kt of SO2) of these episodes.

Sulfur Dioxide↗

Aerosol Layer Height With Enhanced Spectral Coverage Achieved by Synergy Between VIIRS and OMPS-NM Measurements

This study presents a near production-ready algorithm to retrieve the height of biomass burning smoke and mineral dust aerosols as part of NASA’s Deep Blue aerosol data product suite. It utilizes the enhanced spectral coverage achieved by using co-located data from the Visible Infrared Imaging Radiometer Suite (VIIRS) and the Ozone Mapping and Profiler Suite Nadir Mapper (OMPS-NM), both aboard the Suomi National Polar-orbiting Partnership (S-NPP) satellite. Specifically, the 412 nm top-of-atmosphere reflectance from VIIRS and the ultraviolet aerosol index from OMPS-NM are used to determine the height and single-scattering albedo of the absorbing aerosols simultaneously. Constraints on aerosol optical depth at 550 nm and surface reflectance for the 412 nm band are provided by the operational VIIRS Deep Blue aerosol product. Wildfire smoke layer heights obtained from the algorithm over North America, where smoke plumes often stretched thousands of kilometers, are shown to agree with those from Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) measurements, with an uncertainty generally within 1-1.5 km. This new height data set will be included in the upcoming Version 2 VIIRS Deep Blue aerosol product.

Aerosol↗

Aerosol Layer Height with Enhanced Spectral Coverage Achieved by Synergy between VIIRS and OMPS-NM Measurements

This letter presents a near production-ready algorithm to retrieve the height of biomass burning smoke and mineral dust aerosols as part of National Aeronautics and Space Administration (NASA)’s Deep Blue aerosol data product suite. It utilizes the enhanced spectral coverage achieved by using colocated data from the Visible Infrared Imaging Radiometer Suite (VIIRS) and the Ozone Mapping and Profiler Suite Nadir Mapper (OMPS-NM), both aboard the Suomi National Polar-orbiting Partnership (S-NPP) satellite. In particular, the 412-nm top-of-atmosphere (TOA) reflectance from VIIRS and the ultraviolet aerosol index from OMPS-NM are used to determine the height and single-scattering albedo of the absorbing aerosols simultaneously. Constraints on aerosol optical depth at 550 nm and surface reflectance for the 412-nm band are provided by the operational VIIRS Deep Blue aerosol product. Wildfire smoke layer heights obtained from the algorithm over North America, where smoke plumes often stretched thousands of kilometers, are shown to agree with those from Cloud–Aerosol Lidar with Orthogonal Polarization (CALIOP) measurements, with an uncertainty generally within 1–1.5 km. This new height data set will be included in the upcoming Version 2 VIIRS Deep Blue aerosol product.

aerosol↗

Multi-Decadal Nitrogen Dioxide and Derived Products from Satellites (MINDS) Datasets Released by NASA GES DISC and Their Applications for Air Quality

Nitrogen dioxide (NO2), a pervasive air pollutant, comes from vehicles, power plants, industrial emissions, and off-road sources such as construction or lawn and gardening equipment. The NASA Goddard Earth Sciences Data and Information Services Center (GES DISC) curates many remote sensing datasets with NO2 retrievals, which have been utilized for air quality research and applications. The remotely-sensed datasets include those generated by the Ozone Monitoring Instrument (OMI) on the Aura satellite, the TROPOspheric Monitoring Instrument (TROPOMI) onboard the Copernicus Sentinel-5 Precursor (S5P), and the Ozone Mapping and Profiling Suite (OMPS) Nadir-Mapper (NM) instrument on the Suomi National Polar-orbiting Partnership (S- NPP). In collaboration with the NASA Making Earth System Data Records for Use in Research Environments (MEaSUREs) Multi-Decadal Nitrogen Dioxide and Derived Products from Satellites (MINDS) project, the GES DISC recently released MINDS datasets. The NASA MEaSUREs MINDS project aims to develop long-term NO2 global data records by adapting a consistent retrieval algorithm to multiple instrument measurements. Long-term data records will be achieved by applying consistent retrieval approaches to multiple satellite instruments, including OMI (2004 - ); the Global Ozone Monitoring Experiment (GOME, 1995-2011) onboard the second European Remote Sensing satellite (ERS-2); the Scanning Imaging Spectrometer for Atmospheric Cartography (SCIAMACHY, 2002-2012) onboard the ENVIronmental SATellite (ENVISAT); GOME-2 on the Meteorological Operational satellites (MetOp-A and MetOp-B, 2006 - ); and TROPOMI onboard the Copernicus S5P (2017 - ). The long-term record (1995 to present) of MINDS datasets makes them very useful for air quality trend studies. Some MINDS datasets with high spatial resolution of only a few kilometers can be used for air quality research and applications at regional scales. In this presentation, we will introduce all of the MINDS products and services, and demonstrate use cases of MINDS data for studying air quality. We will also present a few other NO2 datasets acquired from NASA’s Health and Air Quality Applied Sciences Team (HAQAST), to be archived and distributed by the GES DISC, and highlight some of their applications for air quality and health.

Feng Ding↗

Improved Assessment of Recent Trends in NOx and VOC Emissions and Ozone Production Sensitivity Regimes Using Satellite Data

This presentation highlights results from a NASA Aura Science Team and Atmospheric Composition Modeling and Analysis Program (ACMAP) project which study the capability to observe and model trends in ozone (O3) production regimes using spaceborne sensors. Ultraviolet– visible (UV–Vis) tropospheric column satellite retrievals of formaldehyde (HCHO) (a proxy for volatile organic compound [VOC] reactivity) and nitrogen dioxide (NO2) (a proxy for nitrogen oxides [NOx]) are frequently used to investigate the sensitivity of O3 production to emissions of NOx and VOCs. There are challenges that come from using satellite-derived ratios of HCHO and NO2 (FNR) to study O3 production sensitivity with the largest uncertainties associated with specific spaceborne sensor’s retrieval biases and errors. This study quantifies the differences and improvements in satellite retrievals of O3 production sensitivity regimes using FNRs when moving from legacy polar orbiting satellites such as the Ozone Monitoring Instrument (OMI) onboard NASA’s Aura satellite and Ozone Mapping and Profiler Suite Nadir Mapper (OMPS-NM) onboard the NASA/NOAA Suomi-NPP platform to newer, higher spatiotemporal resolution satellite sensors TROPOspheric Monitoring Instrument (TROPOMI) and eventually the recently launched NASA geostationary sensor Tropospheric Emissions: Monitoring of Pollution (TEMPO). Furthermore, we investigate how using retrievals of NO2 and HCHO from these different satellites to constrain model predictions impacts the ability to accurately simulate O3 chemistry including chemical production regimes. To this end, we have conducted inverse model simulations, using the WRF-CMAQ-DDM data assimilation system at 12 km × 12 km, to constrain emissions of NOx and VOCs over the contiguous United States (CONUS) when assimilating OMI and TROPOMI retrievals of NO2 and HCHO. Two advantages of this are that we a) account for each satellite’s errors/biases in the emission estimation and b) update the prior profile to ensure that only radiance information is used for optimizing the emissions. This presentation will demonstrate: a) the varying accuracy of different satellite retrieved FNRs and ability to capture known sub-annual emission trends (e.g., seasonal, weekend/weekday) and emission anomalies during the COVID-19 lockdown of 2020, b) the differences and improvements in top-down emission estimates of NOx and VOCs when constrained by newer satellite sensors compared to legacy systems, and c) multi-sensor optimized emission estimates of summer-time NOx and VOCs between 2019-2021.

Data↗

The OMPS Limb Profiler Instrument: An Alternative Data Analysis and Retrieval Algorithm

The upcoming Ozone Mapper and Profiler Suite (OMPS), which will be launched on the NPOESS Preparatory Project (NPP) platform in early 2011, will continue monitoring the global distribution of the Earth's middle atmosphere ozone and aerosol. OMPS is composed of three instruments, namely the Total Column Mapper (heritage: TOMS, OMI), the Nadir Profiler (heritage: SBUV) and the Limb Profiler (heritage: SOLSE/LORE, OSIRIS, SCIAMACHY, SAGE III). The ultimate goal of the mission is to better understand and quantify the rate of stratospheric ozone recovery. The focus of the paper will be on the Limb Profiler (LP) instrument. The LP instrument will measure the Earth fs limb radiance (which is due to the scattering of solar photons by air molecules, aerosol and Earth surface) in the ultra-violet (UV), visible and near infrared, from 285 to 1000 nm. The LP simultaneously images the whole vertical extent of the Earth's limb through three vertical slits, each covering a vertical tangent height range of 100 km and each horizontally spaced by 250 km in the cross-track direction. The focal plane of the LP spectrometer is a two ]dimensional CCD array comprised of 340 x 740 pixels. Several data analysis tools are presently being constructed and tested to retrieve ozone and aerosol vertical distribution from limb radiance measurements. The primary NASA algorithm is based on earlier algorithms developed for the SOLSE/LORE and SAGE III limb scatter missions. The paper will describe an alternative algorithm which will retrieve ozone density and aerosol extinction directly from radiance data collected on individual CCD pixels. This alternative method uses an optimal estimation approach to retrieve ozone and aerosol in the 10-60 km range from the information contained within an ensemble of about 50000 down-linked pixels. Tangent height registration is performed using the Rayleigh Scattering Attitude Sensor (RSAS) technique applied to columns of pixels in the 340-360 nm range. Cloud height is determined by analyzing the radiance first derivative along pixel columns at longer wavelengths. Wavelength registration is performed using rows of pixels and identifying Fraunhofer solar lines within the measured spectra. Special attention is given to stray-light decontamination and modeling of the measured finite spectral/spatial line shape functions.

Rault, Didier F.↗

The OMPS Limb Profiler Instrument: Two-Dimensional Retrieval Algorithm

The upcoming Ozone Mapper and Profiler Suite (OMPS), which will be launched on the NPOESS Preparatory Project (NPP) platform in early 2011, will continue monitoring the global distribution of the Earth's middle atmosphere ozone and aerosol. OMPS is composed of three instruments, namely the Total Column Mapper (heritage: TOMS, OMI), the Nadir Profiler (heritage: SBUV) and the Limb Profiler (heritage: SOLSE/LORE, OSIRIS, SCIAMACHY, SAGE III). The ultimate goal of the mission is to better understand and quantify the rate of stratospheric ozone recovery. The focus of the paper will be on the Limb Profiler (LP) instrument. The LP instrument will measure the Earth's limb radiance (which is due to the scattering of solar photons by air molecules, aerosol and Earth surface) in the ultra-violet (UV), visible and near infrared, from 285 to 1000 nm. The LP simultaneously images the whole vertical extent of the Earth's limb through three vertical slits, each covering a vertical tangent height range of 100 km and each horizontally spaced by 250 km in the cross-track direction. Measurements are made every 19 seconds along the orbit track, which corresponds to a distance of about 150km. Several data analysis tools are presently being constructed and tested to retrieve ozone and aerosol vertical distribution from limb radiance measurements. The primary NASA algorithm is based on earlier algorithms developed for the SOLSE/LORE and SAGE III limb scatter missions. All the existing retrieval algorithms rely on a spherical symmetry assumption for the atmosphere structure. While this assumption is reasonable in most of the stratosphere, it is no longer valid in regions of prime scientific interest, such as polar vortex and UTLS regions. The paper will describe a two-dimensional retrieval algorithm whereby the ozone distribution is simultaneously retrieved vertically and horizontally for a whole orbit. The retrieval code relies on (1) a forward 2D Radiative Transfer code (to model limb radiances within a non-uniform atmosphere and evaluate 2D analytical partial derivatives) and (2) an optimal estimator inversion routine. The algorithm uses the typically sparse nature of the kernel matrices as well as fast matrix inversion techniques to allow for fast inversion of limb data with efficient memory management (as was done for MIPAS data processing). While the method has so far only been developed in the context of Single Scatter, the paper will show how the CPU intensive Multiple Scatter modeling can be implemented using parallel CPU processing. Initial results will be presented in terms of retrieved ozone profiles and code performance.

Rault, Didier F.↗

Ozone Vertical Profile Satellite Measurements by S-NPP OMPS, Aura MLS, and Sentinel-5P TROPOMI

NASA has been monitoring ozone variations from space since 1970 with the launch of the Backscatter Ultraviolet instrument (BUV) on Nimbus- 4. Ozone in the Earth’s stratosphere and troposphere plays a crucial role in protecting life from harmful solar UV radiation, and it also influences Earth’s climate. The vertical distribution of ozone is used in modeling forecasts, verifying model analysis and simulations, and improving the measurement of tropospheric ozone that is a toxic constituent of air pollution. The Microwave Limb Sounder (MLS) on the EOS Aura spacecraft has been monitoring long-term continuous stratosphere ozone vertical behaviors since 2004. The Ozone Mapper Profile Suite (OMPS) on the Suomi National Polar-orbiting Partnership (S-NPP) was launched in 2011. Two of its three instruments, the Limb Profiler (LP) and the Nadir Profiler (NP), are designed to map ozone profiles with full global coverage (~6 days for NP) and a high level of vertical accuracy (1-km reporting record for LP) in the stratosphere and upper troposphere. The TROPOspheric Monitoring Instrument (TROPOMI) on the Copernicus Sentinel-5 Precursor (S5P), launched in 2017, aims to retrieve ozone profiles in both the troposphere and up to top-of-atmosphere (TOA) by using UV radiation measurements in a spectral range of 270-320 nm. S5P/TROPOMI ozone profile products are planned to become available in April 2020. This presentation will concentrate on satellite ozone vertical profile data collections from OMPS and MLS which are archived at the NASA Goddard Earth Sciences Data and Information Services Center (GES DISC). TROPOMI ozone vertical profiles for the troposphere and to top-of-atmosphere will become available at NASA GES DISC in 2020. The presentation briefly explores their potential complementary usability in determining three-dimensional ozone global distributions with high temporal and spatial resolutions.

Zeng, Jian↗

Postlaunch Performance of the Suomi National Polar-Orbiting Partnership Ozone Mapping and Profiler Suite (OMPS) Nadir Sensors

The prelaunch specifications for nadir sensors of the Ozone Mapping and Profiler Suite (OMPS) were designed to ensure that measurements from them could be used to retrieve total column ozone and nadir ozone profile information both for operational use and for use in long-term ozone data records. In this paper, we will show results from our extensive analysis of the performance of the nadir mapper (NM) and nadir profiler (NP) sensors during the first year and a half of OMPS nadir operations. In most cases, we determined that both sensors meet or exceed their prelaunch specifications. Normalized radiance (radiance divided by irradiance) measurements have been determined to be well within their 2% specification for both sensors. In the case of stray light, the NM sensor is within its 2% specification for all but the shortest wavelengths, while the NP sensor is within its 2% specification for all but the longest wavelengths. Artifacts that negatively impacted the sensor calibration due to diffuser features were reduced to less than 1% through changes made in the solar calibration sequence. Preliminary analysis of the disagreement between measurements made by the NM and NP sensors in the region where their wavelengths overlap indicates that it is due to shifts in the shared dichroic filter after launch and that it can be corrected. In general, our analysis indicates that both the NM and NP sensors are performing well, that they are stable, and that any deviations from nominal performance can be well characterized and corrected.

ozone↗