Development of Inexpensive, Automatic, Real-Time Measurement System for On-Line Methane Content and Biogas Flowrate
Not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
In the subcritical systems, the subcriticality level must be monitored continuously to ensure the safe operation of the systems. Techniques such as the neutron source-modulation method and the flux-to-current ratio method have been proposed for on-line reactivity measurements of the subcritical systems. However, the accuracy of these methods is unknown in the actual applications. In this report, the fundamental concepts of these techniques are visited, with numerical simulation techniques developed to validate these on-line reactivity monitoring methodologies. Specifically, the Monte Carlo numerical simulation results show that the neutron source-modulation method is not accurate in determining the reactivity of the subcritical systems. The flux-to-current ratio method can provide on-line reactivity measurements, and its spatial effects have been studied and well understood through the numerical simulations of the fuel loading of the neutron source facility of Ukraine. In addition, a modified version of the area-ratio method is proposed for the on-line measurements of the absolute reactivity of the subcritical systems. Monte Carlo numerical simulations showed that this method can provide the absolute reactivity of the subcritical systems within ~5% error, if the neutron detectors are placed close to the fuel assembly interface with the reflector zone or in the reflector zones away from the neutron source.
Advanced reprocessing schemes such as the Zircex process are important for continued development of the nuclear fuel cycle. The hydrochlorination reaction of the Zircex process flow sheet for metallic fuels has a known off-gas stream of H 2 (g) and HCl. The flow sheet can be simplified through HCl recycling, which requires detection and quantification of any residual H 2 (g) for safety and purity. In this work, commercially available Raman spectroscopy was applied for low-level, on-line detection of H 2 (g) in process gas streams, and parameters were adjusted to optimize the H 2 (g) Raman signal. Increasing the number of scans and exposure time in the spectrometer increased the signal-to-noise ratio of the H 2 (g) Raman signal, while the gas flow rate was optimized at 2.3 L/min. The limit of detection for H 2 (g) was estimated to be 2,100 ppm H 2 (g) in an N 2 (g) background. This scoping study for the application of Raman spectroscopy for on-line measurements of H 2 (g) shows that H 2 (g) can be detected at low levels (approximately 5% of the lower explosive limit (LEL)) in flowing gas streams.
A key application of Phasor Measurement Units (PMUs) is power system oscillation detection. An energy detector is a straightforward detection method, but setting thresholds requires extensive and time consuming baselining of data. This paper proposes a novel on-line method of whitening PMU measurements supporting a framework for detecting forced oscillations without requiring extensive baselining. An example of 24 hours of actual PMU data illustrates how a forced oscillation is very visible in the energy signal of the whitened data, while being hard to detect in the colored ambient noise. With this framework, the statistical theory for setting thresholds without baselining is much more straightforward and is the focus of future work.
This report describes the salt chemistry and sedimentation studies that were completed in FY23 as part of the Pyrochemical Fuel Cycles – ANL project. The primary objective of these activities was to employ electrochemical methods in order to quantify and gain insights into the reaction mechanisms associated with the interaction of O2 and moisture impurities with the molten chloride salts used for the pyrochemical processing of nuclear materials. If not monitored and controlled, the ingression of these atmospheric impurities can lead to changes in the salt redox conditions and initiate the formation of oxide particles, potentially resulting in operational and safeguards challenges. By elucidating the mechanisms underlying the formation of oxide particles, we can effectively monitor the conditions of the salt and design systems to mitigate the influence of atmospheric O2 and H2O. To achieve these goals, we designed a test system that allowed for precisely controlled gas ingressions into the molten salt vessel. This system included on-line monitoring provided by electrochemical probes that enable near real-time measurements of the salt conditions throughout the course of the experiment. Using this system, we systematically varied experimental conditions, including O2/Ar flow rates and O2 concentrations, to comprehensively understand their impact on solid particle formation. We also used a particle size and shape analyzer to characterize the particles that were generated. Tests in FY23 concentrated on the formation of CeO2 particles, but we also prepared a separate apparatus targeting UO2 particles for use in FY24. We additionally conducted extensive modeling activities in support of this work. This included multiphysics simulations of the gas ingressions along with the development of a machine learning workflow to enable accelerated molecular dynamics modeling of the molten salt chemistry of LiCl-KCl-UCl3. The combination of experimental and modeling tools has allowed us to begin to get a more complete understanding of the reactions that occur when atmospheric ingressions occur in pyroprocessing systems.
Optical flow cells are critical measurement interfaces, yet sampling under harsh conditions — high pressure, high temperature, particles, moisture, or corrosive gases — makes it difficult to maintain optical quality without perturbing the measurement. To address this challenge, a new flow cell was developed using a laminar coaxial flow field that separates the purge and sample flows. A dedicated test system was built to evaluate particle size distribution (PSD) measurements using a Malvern Panalytical Insitec analyzer. Results demonstrated that the sample flow alone defines the measurement zone, while the purge flow effectively shields the optical windows from deposition, eliminating sampling bias. The flow cell enables reliable PSD measurement under high pressure and temperature in moist, corrosive environments. As a key demonstration, the instrument was successfully deployed for on-line PSD measurement of flue gas from a 100 kWth pressurized oxy-coal combustor at 15 bara.
A flow cell is a critical measurement interface for many optical instruments. However, the flows are often sampled under harsh conditions, such as under high pressure and/or high temperature, in the presence of particles, moisture, vapors with high dew points or corrosive gases. Therefore, obtaining a high-optical-quality flow cell that does not perturb the measurement is a significant challenge. To address this challenge, we proposed a new flow cell that employs a unique laminar coaxial flow field (for the purge and sample flows). A test system was built to conduct particle size distribution (PSD) measurements with no sampling bias using a state-of-the-art analyzer (Malvern Panalytical Insitec). The results revealed that the measurement zone is well defined solely by the sample flow, and the optical windows are well protected by the purge flow, with minimal risk of any depositions from the sample flow. Using this flow cell, the Insitec can successfully measure PSD under high pressure and temperature under moist, corrosive conditions without generating any sampling bias. Importantly, we successfully applied this flow cell for on-line PSD measurement for the flue gas of a 100 kWth pressurized oxy-coal combustor operating at 15 bara.
The past decades have witnessed the development of new X-ray beam sources with brightness growing at a rate surpassing Moore’s law. Current and upcoming diffraction limited and fully coherent X-ray beam sources, including multi-bend achromat based synchrotron sources and high repetition rate X-ray free electron lasers, puts increasingly stringent requirements on stability and accuracy of X-ray optics systems. Parasitic motion errors at sub-micro radian scale in beam transport and beam conditioning optics can lead to significant loss of coherence and brightness delivered from source to experiment. To address this challenge, we incorporated optical metrology based on interferometric length and angle sensing and real-time correction as part of the X-ray optics motion control system. A prototype X-ray optics system was constructed following the optical layout of a tunable X-ray cavity. On-line interferometric metrology enabled dynamical feedback to a motion control system to track and compensate for motion errors. The system achieved sub-microradian scale performance, as multiple optical elements are synchronously and continuously adjusted. This first proof of principle measurement demonstrated both the potential and necessity of incorporating optical metrology as part of the motion control architecture for large scale X-ray optical systems such as monochromators, delay lines, and in particular, X-ray cavity systems to enable the next generation cavity-based X-ray free electron lasers.
Diagnosing battery states such as health, state-of-charge, or temperature is crucial for ensuring the safety and reliability of electrochemical energy storage systems. While some states, such as temperature, may be measured using cheap sensors, accurate diagnosis of battery health metrics usually requires time-consuming performance measurements, making them infeasible for use in real-world operation. These health metrics can be measured during lab-testing and then estimated on-line using predictive life models or via state observer algorithms such as Kalman filters, but these predictive methods should be supplemented by actual measurement of battery health whenever possible to ensure reliability. Rapid measurement of battery health may be done by various types of fast diagnostic techniques such as electrochemical impedance spectroscopy (EIS), which can be performed in only a few minutes and require only a fraction of the energy and power needed for a full charge and discharge measurement. But there is a substantial challenge for estimating battery health using EIS data, as EIS is sensitive to cell temperature, state-of-charge, current, and resting time in addition to health. Thus, utilizing EIS data to predict battery capacity requires correcting for all these additional variables, a task that is extremely difficult to handle analytically. This talk utilizes machine-learning methods to estimate the effectiveness of battery capacity prediction from EIS data, leveraging a data set of hundreds of EIS measurements recorded at varying temperature and state-of-charge throughout a 500-day aging study of 32 commercial, large-format NMC-Graphite lithium-ion batteries. Using EIS as input to machine-learning models is complicated by the nonlinear response of impedance to battery health, temperature, and state-of-charge, as well as the collinearity between the impedance response at neighboring frequencies, which can easily lead to overfit models. To train robust models, features from EIS data need to be extracted from the data or some subset of critical frequencies selected. Many approaches for extracting and selecting features from EIS data from electrochemical analysis and machine-learning fields were identified for analysis: using the entire raw spectra; selection of one, two, or many frequencies from the entire spectra; selecting interesting points from the EIS measurement using domain knowledge; fitting EIS with an equivalent-circuit model; calculating statistics on the raw impedance values; and reducing the dimensionality of the data using unsupervised linear (principal component analysis) and non-linear (uniform manifold approximation and projection) methods. These approaches were rigorously compared using a machine-learning pipeline approach, training linear, Gaussian process, and random forest regression models and quantifying performance using cross-validation as well as a held-out test set. An artificial neural network model trained on the raw spectra was also tested. Promising pipelines were fine-tuned via Bayesian hyperparameter optimization using cross-validation loss and training with class-specific weights to counter data set imbalance. The most reliable method for utilizing impedance in this work was the selection of two optimal frequencies through an exhaustive search, resulting in about 2% mean absolute error on test data for both Gaussian process and random forest model architectures. Interrogation of a variety of models reveals critical frequencies of 100 Hz and 103 Hz for this data set, though the optimal set of frequencies is not necessarily intuitive, i.e., the best performing models are not simply those that use impedance at frequencies that have the highest correlation to the relative discharge capacity. The best performing model is an ensemble model, which is able to predict battery capacity with 1.9% mean absolute error for unseen cells using impedance recorded at a variety of temperatures and states-of-charge.
Knowledge of real-time solution properties and composition is a necessity for any spent nuclear fuel reprocessing method. Metal-ligand speciation in aqueous solutions derived from the dissolved commercial spent fuel is highly dependent upon the acid concentration/pH, which influences extraction efficiency and the resulting speciation in the organic phase. Spectroscopic process monitoring capabilities, incorporated in a counter current centrifugal contactor bank, provide a pathway for on-line real-time measurement of solution pH. The spectroscopic techniques are process-friendly and can be easily configured for on-line applications, while classic potentiometric pH measurements require frequent calibration/maintenance and have poor long-term stability in aggressive chemical and radiation environments. Our research is focused on developing a general method for on-line determination of pH of aqueous solutions through chemometric analysis of Raman spectra. Interpretive quantitative models have been developed and validated under the range of chemical composition and pH using a lactic acid/lactate buffer system. The developed model was applied to spectra obtained on-line during solvent extractions performed in a centrifugal contactor bank. The model predicted the pH within 11% for pH > 2, thus demonstrating that this technique could provide the capability of monitoring pH on-line in applications such as nuclear fuel reprocessing.
Purpose: External beam radiotherapy currently represents an important therapeutic strategy for the treatment of intraocular tumors. Accurate target localization and efficient compensation of involuntary eye movements are crucial to avoid deviations in dose distribution with respect to the treatment plan. This paper describes an eye tracking system (ETS) based on noninvasive infrared video imaging. The system was designed for capturing the tridimensional (3D) ocular motion and provides an on-line estimation of intraocular lesions position based on a priori knowledge coming from volumetric imaging. Methods: Eye tracking is performed by localizing cornea and pupil centers on stereo images captured by two calibrated video cameras, exploiting eye reflections produced by infrared illumination. Additionally, torsional eye movements are detected by template matching in the iris region of eye images. This information allows estimating the 3D position and orientation of the eye by means of an eye local reference system. By combining ETS measurements with volumetric imaging for treatment planning [computed tomography (CT) and magnetic resonance (MR)], one is able to map the position of the lesion to be treated in local eye coordinates, thus enabling real-time tumor referencing during treatment setup and irradiation. Experimental tests on an eye phantom and seven healthy subjects were performed to assess ETS tracking accuracy. Results: Measurements on phantom showed an overall median accuracy within 0.16 mm and 0.40° for translations and rotations, respectively. Torsional movements were affected by 0.28° median uncertainty. On healthy subjects, the gaze direction error ranged between 0.19° and 0.82° at a median working distance of 29 cm. The median processing time of the eye tracking algorithm was 18.60 ms, thus allowing eye monitoring up to 50 Hz. Conclusions: A noninvasive ETS prototype was designed to perform real-time target localization and eye movement monitoring during ocular radiotherapy treatments. The device aims at improving state-of-the-art invasive procedures based on surgical implantation of radiopaque clips and repeated acquisition of X-ray images, with expected positive effects on treatment quality and patient outcome.
Optical spectroscopy is a valuable tool for on-line monitoring of a variety of processes. Ultraviolet-visible (UV-vis) spectroscopy in particular, can monitor the concentration of analytes as well as identify speciation and oxidation state. However, it can be difficult to impossible to employ UV-vis based sensors on chemical systems that are very dark (i.e., high optical density) as exceedingly short pathlengths are required (for transmission approaches) or effective means of backscattering are needed (for reflectance approaches). Examples of processes that would benefit significantly from the use of optical sensors and encounter these challenges include used nuclear fuel recycling and molten salts with high concentrations of dissolved uranium. Utilizing an attenuated total reflectance (ATR) UV-vis approach can overcome these challenges and allow for the measurement of solutions orders of magnitude more concentrated than transmission UV-vis. However, determining ideal sensor specifications for varied processes can be time consuming and expensive. Here, in this study, we evaluate the ability for a novel ATR-UV-vis probe to measure very concentrated solutions of Co(II) and Ni(II) nitrate as well as organic dyes (methylene blue, acid red 1, and crystal violet). This sensor design provides a modular method for exploring possible “pathlengths” by altering the exposed ATR fiber length. Also studied were approaches to loading and measuring the sensor cell. These results are compared to a traditional 1 cm cuvette measured by transmission UV-vis. It was found that the ATR-UV-vis probe was capable of measuring solutions 600 times more concentrated than the 1 cm cuvette. Advanced data analysis in the form of multivariate curve resolution (MCR) was used to analyze the speciation of methylene blue over a large concentration range. The application of this novel ATR-UV-vis probe to the interrogation of dark solutions is a promising avenue for use in on-line monitoring of nuclear processes.
Fluorescence spectroscopy is a widely used sensor methodology that analyzes light emitted from a compound or element as it decays from an excited state. This technique is very sensitive and selective, which is ideal to characterize analytes at lower limits of detection. Key example targets of significant industry and research interest include rare earth elements (REEs) such as dysprosium (Dy) and europium (Eu). These are widely used in advanced technologies including semiconductors, electric vehicle motors, lasers, and permanent magnets. Identifying new sources and responsible reutilization of REEs is essential, and new approaches to extract and recycle REEs could be notably enhanced through the integration of on-line sensors. The sensors can support faster process design, informed scale-up, and cost-effective deployment. This study covers the initial exploration of applying fluorescence-based on-line monitoring to REEs within a precipitation process. This study demonstrates the successful scale-up of a fluorescence -based sensing approach, from stationary cuvettes and small-volume microfluidic devices to continuous flow systems operating at the bench scale (10-25mL). This work also provides initial insight into the challenges of signal’s effects and utility within a turbid environment. Using a modular design for monitoring flowing solutions in a flow tube, fluorescence can be characterized for a variety of analytical targets. In this study, detection performance parameters between the cuvette and flow tube system were compared. Additionally, the response of Dy during precipitation by sodium bicarbonate in the two measurement designs was explored. This letter represents a starting point to bridge the gap between traditional fluorescence sensor measurements in a cuvette to future developments that explore the ability to integrate fluorescence sensors into extraction and separation processes at industrially relevant scales.
A fast neutron tomography imaging instrument has been designed, built, and tested at The Ohio State University 500 kW Research Reactor on a fast neutron beamline with a peak neutron flux ≈5.4 × 107 n·cm−2·s−1 at 1.6 MeV median neutron energy. The instrument and beamline are also configurable for thermal neutron imaging. The imaging apparatus is composed of a lens coupled, water-cooled Electron Multiplying Charge Coupled Device camera, a front-surface mirror, and a high light yield plastic Polyvinyl toluene scintillator. The instrument sits on a mobile cart. A total of 5 motion-control stages are built into the system for XYZ and rotational degrees of freedom for sample positioning; the fifth stage fine tunes the focal distance between the camera and the scintillator to achieve on-line focusing. A Python code with a user-friendly graphical user interface controls the fully automated image acquisition, not requiring user interaction, yet facilitating tracking of the image acquisition. A complete fast neutron computed tomography dataset with 360 projections requires less than 3 h, with 30 s per projection. On-line focusing is accomplished with a commercial, off-the-shelf, dielectrically actuated liquid lens. Finally, tomographic reconstructions are visualized using the Livermore Tomography Tools software package. The effective pixel size (width and height) is ≈0.1058 mm, yielding a minimum voxel size of 0.1058 × 0.1058 × 0.1058 mm3, and produces a spatial resolution of 231 μm when calculated from knife-edge measurements.
This research discusses development of a software-controlled laboratory instrument based spread spectrum time domain reflectometry system (SSTDR). This constitutes one task within PNNL’s Light Water Sustainability Program (LWRS) whose mission includes advancing nondestructive examination (NDE) techniques for off-line and on-line in-situ cable condition monitoring. In 2022, PNNL evaluated SSTDR for detection and characterization of a number of cable anomalies (Glass et al. 2022). The review included comparison of SSTDR to Frequency Domain Reflectometry (FDR) techniques which have enjoyed encouraging feedback and are starting to be used in nuclear power plants for periodic cable condition monitoring of cable systems as part of the plant’s overall cable aging management program. The FDR test introduces a broad-band chirp onto the cable at the cable end then listens for any reflection from a change of impedance along the cable caused by a damaged conductor or insulation, splices, contact with moisture, or other cable anomalies. The signal is captured in the frequency domain then transformed back to the time domain using an inverse Fourier transform (IFT). Based on the velocity of propagation, the impedance response signal is plotted against distance along the cable. Peak locations along the X-axis indicate the distance along the cable where a portion of the signal has been reflected back to the instrument as a result of a cable anomaly. The FDR test is considered the gold standard of reflectometry however it does require the cable to be de-energized to perform the test. The LIVEWIRE commercial SSTDR produces a similar plot to the FDR however all processing is in the time domain. A pseudo-random noise code (PN code) is input onto the cable conductor and the instrument listens for any reflected response from cable anomalies. The SSTDR processes the signal as an autocorrelation comparing the input PN code to any reflected signal detected. The autocorrelation analysis for thermal aging, water and water ingress detection, ground fault and phase-to-phase fault detection at various locations along the cable and with the cable attached and detached from a motor load, and on both energized and un-energized conditions were performed. These results were contrasted to Frequency Domain Reflectometry (FDR) measurements of the un-energized cable. Results were encouraging but indicated more work was warranted – particularly with the SSTDR, it seemed that the insulation damage would likely be better evaluated with multiple bandwidth cable tests particularly including larger bandwidths than were possible with the current commercial instrument. The commercial instrument’s bandwidth was set at 6, 12, 24, and 48MHz but note that SSTDR and FDR definitions of bandwidth trend similarly but are not the same. The FDR response could be more broadly adjusted, and the bandwidth of 100 to 500 MHz produced the best responses. FDR responses to anomalies were clearer than SSTDR responses and indications were that a broader bandwidth SSTDR may lead to improved SSTDR detection capability. This project used a laboratory instrument based SSTDR (primarily using an Arbitrary Waveform Generator (AWG) and a digital oscilloscope plus Python in-house software) that allowed software adjustment of the SSTDR bandwidth, window functions applied to the exciting Pseudo-random Noise (PN) code plus and other aspects of the SSTDR signal processing. Hereafter, this will be referred to as the PNNL SSTDR. Evaluating specific performance of the PNNL SSTDR is left to a separate report. This report documents hardware and software development to produce the SSTDR cable test system.
We report on the masses and hyperfine structure of ground and isomeric states in 114,116,118,120 Ag isotopes, measured with the phase-imaging ion-cyclotron-resonance technique (PI-ICR) with the JYFLTRAP mass spectrometer and the collinear laser spectroscopy beamline at the Ion Guide Isotope Separator On-Line facility, Jyväskylä, Finland. We measured the masses and excitation energies, electromagnetic moments, and charge radii, and firmly established the nuclear spins of the long-lived states. A new isomer was discovered in 118 Ag and the half-lives of 118 Ag long-lived states were reevaluated. We unambiguously pinned down the level ordering of all long-lived states, placing the inversion of the 𝐼 = 0 − and 𝐼 = 4 + states at 𝐴 = 118 (𝑁 = 71). As a result, we compared the electromagnetic moments of each state to empirical single-particle moments to identify the dominant configuration where possible.
2,3-butanediol (2,3-BDO) is an economically important platform chemical that can be produced by the fermentation of sugars using an engineered strain of Zymomonas mobilis . These fermentations require continuous monitoring and modification of fermentation conditions to maximize 2,3-BDO yields and minimize the production of the undesired coproducts glycerol and acetoin. Because of the time required for sampling and off-line chromatographic measurement of fermentation samples, the ability of fermentation scientists to modify fermentation conditions in a timely manner is limited. The goal of this study was to test if near-infrared spectroscopy (NIRS) along with multivariate statistics could reduce the time needed for this analysis and enable real-time monitoring and control of the fermentation. In this work we developed partial least squares (PLS) calibration models to predict the concentrations of glucose, xylose, 2,3-BDO, acetoin, and glycerol in fermentations via NIRS using two different spectrometers and two different spectroscopy modalities. We first evaluated the feasibility of rapid NIRS monitoring through experiments where we measured the signals from each analyte of interest and built NIRS-based PLS models using spectra from synthetic samples containing uncorrelated concentrations of these analytes. All analytes showed unique spectral signatures, and this initial modeling showed that all analytes could be detected simultaneously. We then began work with samples from laboratory fermentation experiments and tested the feasibility of regression model development across two spectral collection modalities (at-line and on-line) and two instruments: a laboratory-grade instrument and a low-cost instrument with a more limited spectral range. All modalities showed promise in the ability to monitor Z. mobilis fermentations of glucose and xylose to 2,3-BDO. The low-cost instrument displayed a lower signal-to-noise ratio than the laboratory-grade instrument, which led to comparatively lower performance overall, but still provided sufficient accuracy to monitor fermentation trends. While the ease of use of on-line monitoring systems was favored as compared to at-line systems due to the lack of sampling required and potential for automated process control, we observed some decrease in performance due to the additional complexity of the sample matrix. We have demonstrated that NIRS combined with multivariate analysis can be used for at-line and on-line monitoring of the concentrations of glucose, xylose, 2,3-BDO, acetoin, and glycerol during Z. mobilis fermentations. The decrease in signal-to-noise ratio when using a low-cost spectrometer led to greater prediction error than the laboratory-grade spectrometer for at-line monitoring. The on-line monitoring modality showed great promise for real time process control via NIRS.
This data package includes processed and undiluted measurements for metal, total carbon, total nitrogen, and anion concentrations from pore water (groundwater) and surface water samples from the Slate River and East River floodplains of Crested Butte, CO, focus field sites for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between May and October of 2022. These measurements were all recorded at the Arizona Laboratory for Emerging Contaminants (ALEC) at the University of Arizona located in Tucson, AZ. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 4C until measured at ALEC.Analysis by ICP-MS (metals):Measurements for total metals were made on the Agilent 7700x ICP-MS (for total metals) – Agilent Technologies, Santa Clara, CA. The analytical QA/QC protocol was adapted from US EPA Method 200.8 for analysis by ICP-MS. Calibration standards were prepared from multi-element stock solutions (SPEX Certiprep, Metuchen, NJ). Calibration curves include at least 7 points with correlation coefficients > 0.995. The QC protocol includes a continuing calibration blank (CCB), a continuing calibration verification (CCV) solution and at least one quality control sample (QCS) to be analyzed just after calibration and again after every 12 samples and at the completion of the run. The QCS solutions are from an independent source, such as NIST SRM 1643e - Trace elements in water, or QCS solutions from High Purity Standards (Charleston, SC). Acceptable QC responses must be between 90 and 110% of the certified value. Lastly, a suitable internal standard (usually Rh, In, Ga or Ge) is added using on-line addition into the sample line and mixing tee.Analysis by Shimadzu TOC-L (TOC/TN):The TOC-L system is a combustion technique where liquid samples are injected and combusted into CO2 for carbon detection by non-dispersive infrared (NDIR) and NO for detection by chemiluminescence. A calibration curve using five standard solutions between 0.1 and 7 ppm for carbon and 0.05 and 3.5 ppm for nitrogen is made for each type of measurement with a linearity >0.99. All samples, standards, and QC’s are prepared in 24mL scintillation vials that have been baked for 4hrs at 475 Cº and made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.Analysis by Ion Chromatography (Anions):The instrument used is the Thermo Scientific Dionex ICS-6000 using AS+AG22 column set for anion analysis with sodium carbonate eluent. A calibration curve using five standard solutions between 5 and 250 umol/L is made with a linearity >0.99. Standards and QC’s are prepared in 15mL polypropylene conical tubes, pipetted along with the samples into 1.5mL polypropylene vials. Dilutions are made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.All files are in csv format.